• Title/Summary/Keyword: 개인 방호

Search Result 136, Processing Time 0.026 seconds

A Study on the Risk Assessment of River Crossing Pipeline in Urban Area (도심지 하천매설배관의 위험성 평가에 관한 연구)

  • Park, Woo-Il;Yoo, Chul-Hee;Shin, Dong-Il;Kim, Tae-Ok;Lee, Hyo-Ryeol
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.22-28
    • /
    • 2020
  • In this study, quantitative risk assessment was carried out for city gas high-pressure pipelines crossing through urban rivers. The risk assessment was performed based on actual city gas properties, traffic volume and population and weather data in the worst case scenario conditions. The results confirmed that the social and individual risks were located in conditionally acceptable areas. This can be judged to be safer considering that the risk mitigation effect of protecting the pipes or installing them in the protective structure at the time of the construction of the river buried pipe is not reflected in the result of the risk assessment. Also, SAFETI v8.22 was used to analyze the effects of wind speed and pasquil stability on the accident damage and dispersion distances caused by radiation. As a result of the risk assessment, the safety of the pipelines has been secured to date, but suggests ways to improve safety by preventing unexpected accidents including river bed changes through periodic inspections and monitoring.

Measurement of the Spatial Dose Rate for Distribution Room in Department of Nuclear Medicine (핵의학과 분배실 내의 공간선량률 측정)

  • Park, Jeong-Kyu;Cho, Euy-Hyun
    • Journal of Digital Contents Society
    • /
    • v.13 no.2
    • /
    • pp.151-157
    • /
    • 2012
  • Even though the protective facility is well made with the development of medicine, the spatial dose within the radiation section could increase the exposure of the workers. The spatial dose is always present in distribution room within the Department of Nuclear Medicine, so the spatial dose of the interior distribution room is measured and analyzed for the prediction of the exposure dose. The spatial dose rate was $6.78{\pm}0.083{\mu}Sv/h$ in the $^{18}F$ distribution room of department of Nuclear Medicine, $9.248{\pm}0.013{\mu}Sv/h$ in $^{99m}Tc$, and $^{131}I$ distribution room. In addition, in case of $^{18}F$ distribution room, the yearly external exposure dose was $42.5{\mu}Sv$ when the nurse does IV in 1m in distance. It also showed that the spatial dose rate on the direction of right oblique showed higher than others by the standard of distribution window of distribution room. Therefore, the staying time of the workers should be short during distributing radiopharmaceuticals in the distribution room and the design of the distribution protection is necessary to reduce the exposure in the direction of right oblique of the protection. The utmost endeavors are required to reduce the worker's individual exposure dose while doing IV.

A Study on the Practice for Infection Prevention of Dental Clinic Worker (치과의료기관 종사자의 감염예방 실천에 관한 연구)

  • Kim, Seo-Yune;Lee, Jae-Ra;Han, Ok-Sung
    • Journal of dental hygiene science
    • /
    • v.14 no.3
    • /
    • pp.397-404
    • /
    • 2014
  • This survey was conducted between January 15, 2014 and February 25, 2014 to investigate the practice for infection prevention among dental hygienists. Data were obtained from 294 dental clinic worker who worked in dental hospital (clinics) of Gwangju and Chonnam. At the conclusion of this investigation, according to the conclusion of this investigation, the necessity of infection control education for dental hygienists and washing their gowns after caring infected patients affected the practice for infection prevention. They also well practiced the infection prevention working in dental hospital. To prevent infection in dental clinic, it is necessary to provide the continuing education programs for dental infection control to dental clinic worker.

Determinants of New Product Performance and Environmental Dynamics as a Moderating Effect (신제품개발성과의 결정요인과 환경동태성의 조절효과)

  • Liu, Zhen;Bang, Ho-Yeol
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.1
    • /
    • pp.845-858
    • /
    • 2019
  • The most serious problem company facing in today's business environment is the failure of new product development outcomes. Statistically, almost half of the new products released each year failed. Despite the innovative technological advances, consumers' expectation level become much higher and global competition is intensifying. In addition, the new product life cycle is becoming shorter and shorter. It is difficult for a company to survive without developing long-lived products. The most important issue in a company's success and failure is the successful development and introduction of new products. Previous research has presented many determinants to achieve a successful new product development. This study focuses on dynamic competence as an important determinant, and identifies the constituting elements. Enterprises need to acquire, absorb, integrate and reconfigure their resources to survive and develop continuously. It is necessary to hold a dynamic ability switching resource bases in order to adapt to changing environments. The results of this study are as follows: First, the effect of learning, reconfiguration, and alliance capabilities on the new product development of small and medium-sized manufacturing enterprises seems to be positive. Second, the integrative and reconfiguration capabilities positively affect a new product development under high environmental turbulence.

Study on the Shortening Effect of the Egress Travel Time Based on an Escape Scenarios by Using Shuttle Elevators for Lotte Tall Building's Evacuation Plan (초고층건물 피난계획시 피난용 엘리베이터 이용에 의한 피난소요시간의 단축효과 연구)

  • Park, Hyung-Joo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.46-54
    • /
    • 2018
  • A total of 19 elevators for evacuation were installed in the Lotte World Tower and it is planned to operate the shuttle using the manual key from five refuge floors to the 1st floor in an emergency. In the event of a fire or other disaster, it is necessary to conduct intensive analysis to determine how much RSET reduction could be achieved using the evacuation elevator compared to the existing evacuation plans. When the optimal transportation sharing ratio by the evacuation elevators was 40% at the Lotte World Tower, the RSET of the evacuation scenario in parallel with the elevators in the entire building was calculated to be 1 hour and 2 minutes. The RSET of a conventional evacuation scenario (Walking along the stairs without using the elevators) was calculated to be 1 hour 29 minutes, therefore, the former evacuation scenario were found to have a shortening effect of approximately 27 minutes compared to the latter. On the other hand, to maintain this effect, each part of the evacuation route using the elevator must have the capability to protect the evacuee from any hazards caused by fires, such as smoke, flame, and radiant heat during the evacuation. Moreover, the evacuation route should be continuous from the residence position of the elevator user to the final evacuation site, and be recognized easily.

A Study Practice of Infection Control for Dental Office and Dental Hygienist and Bacterial Contamination of Dental Office Surface (치과 의료기관 및 치과위생사의 감염관리 실천도와 진료실내의 표면 세균오염도에 대한 연구)

  • Yun, Kyoung-Ok;Bae, Sung-Suk;Choi, Young-Suk
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.5
    • /
    • pp.511-519
    • /
    • 2019
  • The purpose of this study was to investigate the status of infection control in dental office and the degree of infection control practice of dental hygienists. A self-reported questionnaire was answered by 193 dental hygienists working in dental hospitals or dental clinics in Gyeonggi and Incheon areas. The number of bacteria was measured sample of surface dental unit chair shoulder backrests and light handles from 19 dental hospitals and 28 dental clinics. It was responded that impression or occlusion bodies were routinely disinfected in 52.6% of the dental hospitals and dental prosthesis were routinely disinfected in 46.4% in dental clinics. The dental hospital and clinics disinfect the surface each 26.3%, 25% after the patient treatment. The dental hospital and clinic were detected bacteria $5.02^*10\^3CFU/mL$, $1^*10\^4CFU/mL$, from dental unit chair backrest, respectively and $8.32^*10\^3CFU/mL$, $4.26^*10\^4CFU/mL$ from light handles, respectively. At the conclusion of this investigation, it can be kept from infection source in dental office is to make the right selection and use of the personal protective equipments and to improve the practice level by regular and active education. The same infection control practice should be done by institutionalizing and mandating infection control practice.

The Relationship of Dental Hygienists' Performance of Dental Infection Control with Their Health Beliefs and Importance (치과위생사의 건강신념 및 감염관리에 대한 중요도와 치과 감염관리 수행도와의 관련요인)

  • Moon, Sang-Eun;Hong, Sun-Hwa;Lee, Bo-Ram
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.2
    • /
    • pp.227-235
    • /
    • 2021
  • The purpose of this study was to investigate the association factors of dental infection control by applying the health belief model in the dental hygienists. This study subject was 142 dental hygienists from 15 to July 5, 2020. Data were analyzed by chi-square test ANOVA, correlation analysis, and multiple regression analysis using SPSS version 23.0. The performance of dental infection control in accordance with the general characteristics of research subjects was high in case when they had educational experiences of infection control, and when they 'always' did medical examinations by interview about infectious diseases(p<0.01). The group of dental hygienists working for dental clinics with less than average 50 patients a day showed the highest rate of wearing a mask and latex gloves as personal protective gears(p<0.05),(p<0.01). When the wearing of protective goggles(face shield) and the frequency of exchanging masks after the outbreak of COVID-19 were more, the performance for infection control was increasing(p<0.05),(p<0.01),(p<0.001). In this study, it is difficult to generalize the results of the study because the research area and the subject are limited by selecting the subjects by convenience extraction, and focusing on the degree of awareness of infection control by dental hygienists, the actual status of infection control in dentistry is carefully illuminated. What you didn't do can be seen as a limitation. Considering the results of this study, the performance of infection control could be increased by removing obstacles and increasing the importance and perceived benefits of infection control of dental hygienists.

Optimization of Enzyme Treatment Condition for Clarification of Pomegranate Extract (석류추출액의 청징화를 위한 효소처리조건 최적화)

  • Kim, Seong-Ho;Kim, In-Ho;Cha, Tae-Yang;Kang, Bok-Hee;Lee, Jin-Hyung;Kim, Jong-Myung;Song, Kyung-Sik;Song, Bang-Ho;Kim, Jong-Guk;Lee, Jin-Man
    • Applied Biological Chemistry
    • /
    • v.48 no.3
    • /
    • pp.240-245
    • /
    • 2005
  • Response surface methodology was used to investigate clarification characteristics (turbidity, brown color, soluble solid, total sugar and reducing sugar) of enzyme in pomegranate extract. Enzyme was treated at 16 conditions including independent variables of temperature ($35{\sim}55^{\circ}C$), time ($30{\sim}70\;min$) and concentration ($0.02{\sim}0.10%$) based on central composition design. Turbidity was decreased with increase of enzyme concentration, and the minimum value of turbidity was 0.04 (OD) when 0.08% enzyme was treated at $37.99^{\circ}C$ for 60.90 min. Total sugar was affected by all treatment conditions and the maximum value was 8.37% when 0.03% enzyme was treated at $39.28^{\circ}C$ for 42.04 min. Reducing sugar and soluble solid were largely affected by enzyme concentration, and the maximum value of reducing sugar was 7.22% when 0.02% enzyme was treated at $42.96^{\circ}C$ for 46.21 min. The maximum value of soluble solid was 8.13% when 0.02% enzyme was treated at $46.91^{\circ}C$ for 42.13 min.

Study of Absorbed Dose and Effective Dose for Prostate Cancer Image Guided Radiation Therapy using kV Cone Beam Computed Tomography (kV Cone Beam Computed Tomography (CBCT)를 이용한 전립선암 영상유도방사선치료 시 흡수선량 및 유효선량에 관한 고찰)

  • Na, Jong-Eok;Lee, Do-Geun;Kim, Jin-Soo;Baek, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.67-74
    • /
    • 2009
  • Purpose: To evaluate the results of absorbed and effective doses using two different modes, standard mode (A-mode) and low-dose mode (B-mode) settings for prostate cancer IGRT from CBCT. Materials and Methods: This experimental study was obtained using Clinac iX integrated with On Board Imager (OBI) System and CBCT. CT images were obtained using a GE Light Speed scanner. Absorbed dose to organs from ICRP recommendations and effective doses to body was performed using A-mode and B-mode CBCT. Measurements were performed using a Anderson rando phantom with TLD-100 (Thermoluminescent dosimeters). TLD-100 were widely used to estimate absorbed dose and effective dose from CBCT with TLD System 4000 HAWSHAW. TLD-100 were calibrated to know sensitivity values using photon beam. The measurements were repeated three times for prostate center. Then, Evaluations of effective dose and absorbed dose were performed among the A-mode and B-mode CBCT. Results: The prostate absorbed dose from A-mode and B mode CBCT were 5.5 cGy 1.1 cGy per scan. Respectively Effective doses to body from A mode and B-mode CBCT were 19.1 mSv, 4.4 mSv per scan. Effective dose from A-mode CBCT were approximately 4 times lower than B-mode CBCT. Conclusion: We have shown that it is possible to reduce the effective dose considerably by low dose mode(B-mode) or lower mAs CBCT settings for prostate cancer IGRT. Therefore, we should try to select B-mode or low condition setting to decrease extra patient dose during the IGRT for prostate cancer as possible.

  • PDF

Preliminary Study for Development of Low Dose Radiation Shielding Material Using Liquid Silicon and Metalic Compound (액상 실리콘과 금속화합물을 융합한 저선량 방사선 차폐 소재 개발을 위한 사전연구)

  • Jang, Seo Goo;Han, Su Chul;Kang, Sung Jin;Lim, sung wook;Lee, Sung Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.461-468
    • /
    • 2017
  • This study measured and compared the protective clothing using Pb used for shielding in a diagnostic X-ray energy range, and the shielding rates of X-ray fusion shielding materials using Si and $TiO_2$. For the experiment, a pad type shielding with a thickness of 1 mm was prepared by mixing $Si-TiO_2$, and the X-ray shielding rate was compared with 0.5 mmPb plate of The shielding rate of shielding of 0.5 mmPb plate 95.92%, 85.26 % based on the case of no shielding under each 60 kVp, 100 kVp tube voltage condition. When the shielding of $Si-TiO_2$ pad was applied, the shielding rate equal to or greater than 0.5 mmPb plate was obtained at a thickness of 11 mm or more, and the shielding rate of 100% or more was confirmed at a thickness of 13 mm in 60 kVp condition. When the shielding of $Si-TiO_2$ pad was applied, the shielding rate equal to or greater than 0.5 mmPb plate was obtained at a thickness of 17 mm or more, and a shielding rate of 0.5 mmPb plate was observed at a thickness of 23 mm in 100 kVp condition. Through the results of this study, We could confirm the possibility of manufacturing radiation protective materials that does not contain lead hazard using various metalic compound and liquid Si. This study shows that possibility of liquid Si and other metalic compound can harmonize easily. Beside, It is flexible and strong to physical stress than Pb obtained radiation protective closthes. But additional studies are needed to increase the shielding rate and reduce the weight.