• Title/Summary/Keyword: 개인 방호

Search Result 134, Processing Time 0.025 seconds

Induction of Micronuclei in Human and Mouse Lymphocytes Irradiated with Gamma Radiation and Effect of Panax ginseng C.A. Meyer (마우스와 사람 림프구에서 방사선에 의한 미소핵의 형성 및 고려인삼의 효과)

  • Kim, Sung-Ho;Oh, Heon;Lee, Song-Eun;Lee, Yun-Sil;Kim, Tae-Hwan;Jeong, Kyu-Sik;Ryu, Si-Yun
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.153-160
    • /
    • 1997
  • The frequencies of ${\gamma}$-ray-induced micronuclei (MN) in cytokinesis-blocked (CB) lymphocytes at several doses were measured in three donors of human and C57BL/6 mice. Measurements performed after irradiation showed a dose-related increases in MN frequency in each of the donors studied. The relative sensitivity of mouse in spleen lymphocytes (SLs) compared with human peripheral blood lymphocytes (PBLs) was estimated by best fitting linear-quadratic model based on the radiation-induced MN data over the range from 0 cGy to 400 cGy. In the case of MN frequency with 0.2 per CB cell, the relative sensitivity of mouse SLs was 1.67. Compared with the radiation-induced MN formation in the PBLs of human, the SLs of mouse were more radiosensitive. Using this MN assay with human PBLs and mouse SLs, studies were performed to determine whether the water fraction of ginseng (Panax ginseng C.A.Meyer) against radiation-induced MN in human PBLs after in vitro irradiation (3Gy) and in SLs of C57BL/6 mice after in vivo irradiation (3Gy). The frequency of MN in human PBLs was reduced by water fraction of ginseng (0.5mg/ml of medium) both pre-and post treatment (p<0.0l) in vitro. In addition, the frequency of MN in mouse SLs was also reduced by pretreatment of ginseng (2mg/ml of drinking water for 7days) in vivo. The data suggested that the ginseng may reduce cell damage caused by ${\gamma}$-rays in vitro and in vivo. Further studies are needed to characterize better the protective nature of ginseng extract, its fractions and compounds.

  • PDF

Development of the Reference Korean Female Voxel Phantom (한국인 기준여성 체적소형 모의체 개발)

  • Ham, Bo-Kyoung;Cho, Kun-Woo;Yeom, Yoen-Soo;Jeong, Jong-Hwi;Kim, Chan-Hyeong;Han, Min-Cheol
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.41-49
    • /
    • 2012
  • The objective of this study is for development of the reference Korean female phantom, HDRK-Woman. The phantom was constructed by adjusting a Korean woman voxel phantom to the Reference Korean data. The Korean woman phantom had been developed based on the high-resolution color slice images obtained from an adult Korean female cadaver. There were a total of 39 organs including the 27 organs specified in ICRP 103 for effective dose calculation. The voxel resolution of the phantom was $1.976{\times}1.976{\times}2.0619\;mm^3$ and the voxel array size is $261{\times}109{\times}825$ in the x, y and z directions. Then, the voxel resolution was changed to $2.0351{\times}2.0351{\times}2.0747\;mm^3$ for adjustment of the height and total bone mass of the phantom to the Reference Korean data. Finally, the internal organs and tissue were adjusted using in-house software program developed for 3D volume adjustment of the organs and tissue. The effective dose values of HDRK phantoms were calculated for broad parallel photon beams using MCNPX Monte Carlo code and compared with those of ICRP phantoms.

The Study on Organization, Infection Controller, Patient Infection Control of Dental Clinic in Certain Areas (일부지역 치과의 기관, 감염관리자, 환자의 감염관리에 관한 연구)

  • Choi, Du-Ri;Kim, Seol-Hee
    • Journal of dental hygiene science
    • /
    • v.15 no.4
    • /
    • pp.399-406
    • /
    • 2015
  • The purpose of this study was to investigate the performance of dental infection control. This survey was performed on 158 of the dental hygienist in certain areas. The research was performed using a self-reported questionnaire and interview method from June to July, 2014. The collected data was analyzed by PASW Statistics ver. 18.0. Guideline of infection management, infection controller, regular infection control training, Sterilization of the handpiece/per head resulted 57~74% for dental hospital. It was higher than 13~20% for dental clinics (p<0.05). Infection control guidelines and vaccination recognition of dental were more performed in dental hospital. Patient's hand hygiene performed, tooth brushing before treatment, cross infection educational experience was less than 20%, research cooperation of medical history was over 90% (p<0.05). Performing rate of the dental hospital workers were investigated higher in protective personal devices, infection control of treatment room. A correlation analysis about institutional support, infection control of dental hygienists, patients with infection control cooperation showed a positive correlation statistically significant. Infection control can be enhanced when the medical staff, the patient, the organization combined cognitive and practice. Dental hygienist is required to recognize and practice the infection control guidelines through continuing education.

한국원자력연구소 방사선방어기술 개발 및 연구 현황

  • Ha, Jeong-U
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.1
    • /
    • pp.9-13
    • /
    • 1990
  • 1959년 한국원자력연구소가 창립됨과 동시에 &Health Physics&, 즉 보건물리라고 하는 명칭과 조직이 탄생되어, 방사선안전관리의 실무와 보건물리의 연구가 시작되었다. 최초 10년간은 선진제국의 보건물리분야의 연구와 기술을 추적하여 우리나라의 방사선안전관리 기술의 기초를 다지는 시기로서 개인방사선모니터링기술, 환경방사선(능) 모니터링기술 및 방사선방어용계측기기의 교정기술 개발에 중점을 두고 연구개발이 추진되었으며, TRIGA Mark-II 연구용원자로의 가동에 따라 원자로 생체차폐체의 건전성 검증에 관한 유익한 방사선량 측정자료도 얻게 되었다. 즉 이 기간은 방사선안전관리의 체제정비 및 기초기술 확립에 노력한 기간이었다. 1970년대는 원자력 연구개발에 대한 기본방향과 정책의 변경등으로 보건물리 연구조직은 방사선안전관리, 환경연구 그리고 방사화학분야로 분산되었으며, 그로인하여 연구개발활동은 거의 정체되어 겨우 방사선안전관리 실무만이 그 명맥을 유지하였다. 그 결과 우리나라 방사선안전관리 및 그와 관련된 연구개발의 기반이 흔들리게 되었으나, 그러한 환경하에서도 방사선량측정평가기술, 방사선차폐설계기술 및 원자로사고시 피폭선량평가기술의 선진화에 필요한 지식을 얻었으며, 방사선 안전관리에 유익한 실무경험도 축적하게 되었다. 1980년대는 통합된 원자력 연구개발체제의 구축으로 방사선작업종사자 및 일반공중의 피폭저감화 기술개발에 필요한 각종 최신기술을 도입하였고, 관리업무에 있어서도 측정의 정확도와 신뢰성향상 및 새로운 관리기술의 개발에 많은 노력을 한 결과, 유익한성과를 얻게된 기간이다. 특히, 이 기간은 방사선안전관리기술의 선진화를 위한 지식이 축적되어 90년대의 방사선안전관리기술자립화를 위한 전환기로서, 이와같이 축적된 기술은 원자력의 평화적 이용에 크게 기여할 것으로 기대된다.서 dithiothreitol를 투여한 군에서는 우라늄단독투여군에 비해 cretinine의 배설이 상당히 증가하였다(P<0.05). 6. 우라늄오염에 의한 신장의 소견에 있어 우라늄단독투여군은 근위곡세뇨관상피의 공포화 및 종창, microvilli와 brush border의 손실, 세뇨관 상피의 괴사가 관찰되었으며, 간장의 충혈, 중심성 괴사 및 모세관 확장증도 관찰되었다. 그리고 sodium bicarbonate와 생리적 식염수를 병행투여한 군과 우라늄을 투여하고 30분이 지나서 dithiothreitol를 투여한 군에서는 우라늄 단독투여군에 비해 높은 방호효과가 관찰되었으나 다른 실험군에서는 큰 효과가 없는 것으로 나타났다. 결론적으로 우라늄의 체내오염시에는 sodium bicarbonate와 생리적 식염수를 가능한 빨리 병행투여하거나 dithiothreitol을 체내오염후 30분이 지나서 투여하는 방법이 우라늄오염에 대한 제염에 매우 유효할 것으로 생각되며, 특히 우라늄에 의한 인체장해를 유의하게 경감시켜줄 것으로 사료되었다.내의 어떤 부위와도 관계가 되는 것으로 간주되는데 이것이 $(^3H)$ QNB가 $(^3H)$ NMS보다 높은 최대 결합능력 $(B_{max})$을 나타낼 이유이다. (b) 두 종류의 다른 제제에서 우리는 같은 양상의 결과를 관찰하었기에 결점이 많은 homogenates 제제보다는 intact cell aggregates 제제를 수용체 연구에 대한 새로운 실험모형(experiment model)으로 사용할 수 있는 가능성을 제시하고자 한다.$가 38.8%로 가장 많고, 그 다음이 ${\ulcorner}$l9세(歲)이후${\lrcorner}$가 25.2%로서 전체

  • PDF

A Study on the shelf-life of IR screening smoke launcher grenade (적외선 차장 연막유탄 신뢰도 및 저장수명 연구)

  • Lee, Jongchan;Lee, Junhyuk;Jung, Hyunsuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.437-445
    • /
    • 2020
  • Smoke grenades are the primary means of protection used by tanks to disrupt enemy detection systems. Such smoke grenades are a critical factor that determines the survival of tanks in the engagement of ground weapon systems, but it can only be used once. Owing to its destructive property, the performance and safety of the smoke grenade cannot be confirmed prior to use. Therefore, the reliability of smoke grenades can be evaluated through various tests during the storage period. This paper presents the results of estimating the reliability and shelf life of IR screening smoke grenade launchers based on the result of the Ammunition Stockpile Reliability Program conducted in 2019. Among the smoke grenade launcher lots currently stored, 16 lots and samples were selected for each year of manufacture and tested. The reliability and shelf life were estimated by examining the number of defects and the change in quality characteristics of each test item. The results of this study can be used to assess the reliability of the smoke grenade launchers and to improve the quality of manufacturing sites.

Cytokinesis-blocked micronuclei in the human peripheral lymphocytes following low dose γ-rays irradiation (저선량의 감마선 피폭된 사람 말초 임파구의 미소핵을 이용한 방사선 생물학적 피폭선량 측정법 연구)

  • Kim, Tae-hwan
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.1
    • /
    • pp.99-104
    • /
    • 2001
  • To determine if micronucleus (MN) assay could be used to predict the absorbed dose of victims after accidental radiation exposure, we carried out to assess the absorbed dose depending on the numerical changes of MN in human peripheral blood lymphocytes after $^{60}Co\;{\gamma}-rays$ exposure in the range of 0.25 to 1 Gy, respectively. The MNs were observed at very low doses, and the numerical changes according to doses. Satisfactory dose-effect calibration curve is observed after low dose irradiation of human lymphocytes in vitro. When plotting on a linear scale against radiation dose, the line of best fit was $Y=(0.02{\pm}0.0009)+(0.033{\pm}0.010)D+(0.012{\pm}0.012)D^2$. The dose-response curve for MN induction immediately after irradiation was linear-quadratic and has a significant relationship between the frequencies of MN and dose. These data show a trend towards increase of the numbers of MN with increasing dose. The number of MN in lymphocytes that were observed in the control group is $0.1610{\pm}0.0093/cell$. Accordingly, MN assay in human peripheral lymphocytes could be a useful in viva model for studying radio-protective drug sensitivity or screening test, microdosimertic indicator and radiation-induced target organ injury. Since MN assay is simple, rapid and reproducible, it will also be a biodosimetric indicator for individual dose assessment after accidental exposure.

  • PDF

Studies on the application of bacterial sericinase -(Part II) Appling on the unwinding for mulberry cocoon- (세균성(細菌性) Sericin 분해효소(分解酵素)의 이용(利用)에 관(關)한 연구(硏究) -(제II보(第II報)) Sericinase에 의(依)한 가잠견(家蠶繭)의 해서(解舒)에 관(對)하여-)

  • Seu, Jung-Hwn;Song, Bang-Ho;Han, Yung-Gu;Kho, Yung-Hee
    • Applied Biological Chemistry
    • /
    • v.13 no.1
    • /
    • pp.87-92
    • /
    • 1970
  • Sericin hydrolyzing enzyme, produced by the selected bacteria, S4-1-1, was studied and following properties were obtained. 1. The activity of this bacterial sericinase was not decreased for 30 days of storage at $5^{\circ}C$. But at $20^{\circ}C$, for 30 hrs. was the maximum period to keep the initial activity of this enzyme. 2. This bacterial enzyme gave only sericinase activity but never indicated fibroin hydrolyzing activity. 3. The chelating reagent of EDTA and Ag or Hg ions were classified as strung inhibitors but Cu and Cd ions were indicated as moderate inhibitors to this enzyme action. 4. This enzyme was not inhibited by the surface active agent, Peretex-N, but strongly activated by this agent at low concentration. In the other hand, by the application of this enzyme to the unwinding works on the mulberry cocoon, the following results were also obtained. 1. On the weight and length, nonbreaking Length, size, colour and unwinding ratio of have, the enzyme appling method was superior to generally used cooking method. 2. The tested results of strength and elongation, bouchon, haririness loops, neatness and evenness of have were also indicated spuerior properties.

  • PDF

Comparative Analysis of Middle School Science Curriculum between Korea and Israel (우리나라와 이스라엘의 중학교 과학과 교육과정 비교연구)

  • Jang, Jin-Ju;Seo, Hae-Ae;Song, Bang-Ho
    • Journal of The Korean Association For Science Education
    • /
    • v.23 no.5
    • /
    • pp.443-457
    • /
    • 2003
  • The research aimed to compare science curriculum between Korea and Israel and find out characteristics of science curriculum in Israel at middle school level. The middle school 'science' of the 7th revised national curriculum in Korea and middle school 'science and technology' in Israel were compared. Among characteristics of the Israel curriculum of 'science and technology,' distinct ones are as follows: First, 'science and technology' was most highly emphasized with the largest number of time allotment among all subjects at middle school level in Israel. Second, the contents of 'science and technology' were classified into seven areas of 'energy and interaction', 'materials', 'organism', 'earth and the universe', 'technological systems and products' . 'information and communication',and 'ecosystems' rather than four areas of energy, materials, life and earth in Korea. Third, 'organism' was allocated with the highest number of hours among seven areas. Fourth, objectives of each content of 'science and technology' were divided into three categories: scientific aspect, technological aspect, and social value and objectives of each category were related to one another. This characteristic seems to stress STS, multidisciplinary, and interdisciplinary approaches in 'science and technology' in Israel. Such characteristics of the 'science and technology' education in Israel are likely to make significant contributions to establish human resources of highly developing science and technology including IT, BT, NT, ST in the future society. Reflecting upon the characteristics of 'science and technology' education in Israel, Korea might seek for ways to improve its national power based on science and technology through strengthening science and emphasizing science and technology contents among school curriculum.

A Study on the Risk Assessment of River Crossing Pipeline in Urban Area (도심지 하천매설배관의 위험성 평가에 관한 연구)

  • Park, Woo-Il;Yoo, Chul-Hee;Shin, Dong-Il;Kim, Tae-Ok;Lee, Hyo-Ryeol
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.22-28
    • /
    • 2020
  • In this study, quantitative risk assessment was carried out for city gas high-pressure pipelines crossing through urban rivers. The risk assessment was performed based on actual city gas properties, traffic volume and population and weather data in the worst case scenario conditions. The results confirmed that the social and individual risks were located in conditionally acceptable areas. This can be judged to be safer considering that the risk mitigation effect of protecting the pipes or installing them in the protective structure at the time of the construction of the river buried pipe is not reflected in the result of the risk assessment. Also, SAFETI v8.22 was used to analyze the effects of wind speed and pasquil stability on the accident damage and dispersion distances caused by radiation. As a result of the risk assessment, the safety of the pipelines has been secured to date, but suggests ways to improve safety by preventing unexpected accidents including river bed changes through periodic inspections and monitoring.

Measurement of the Spatial Dose Rate for Distribution Room in Department of Nuclear Medicine (핵의학과 분배실 내의 공간선량률 측정)

  • Park, Jeong-Kyu;Cho, Euy-Hyun
    • Journal of Digital Contents Society
    • /
    • v.13 no.2
    • /
    • pp.151-157
    • /
    • 2012
  • Even though the protective facility is well made with the development of medicine, the spatial dose within the radiation section could increase the exposure of the workers. The spatial dose is always present in distribution room within the Department of Nuclear Medicine, so the spatial dose of the interior distribution room is measured and analyzed for the prediction of the exposure dose. The spatial dose rate was $6.78{\pm}0.083{\mu}Sv/h$ in the $^{18}F$ distribution room of department of Nuclear Medicine, $9.248{\pm}0.013{\mu}Sv/h$ in $^{99m}Tc$, and $^{131}I$ distribution room. In addition, in case of $^{18}F$ distribution room, the yearly external exposure dose was $42.5{\mu}Sv$ when the nurse does IV in 1m in distance. It also showed that the spatial dose rate on the direction of right oblique showed higher than others by the standard of distribution window of distribution room. Therefore, the staying time of the workers should be short during distributing radiopharmaceuticals in the distribution room and the design of the distribution protection is necessary to reduce the exposure in the direction of right oblique of the protection. The utmost endeavors are required to reduce the worker's individual exposure dose while doing IV.