• Title/Summary/Keyword: 강재 프레임

Search Result 51, Processing Time 0.024 seconds

Examination of Lateral Torsional Bucling Strength by Increasing the Warping Strength of I-Section Plate Girder with Concrete Filled Half Pipe Stiffener (콘크리트 충전 반원기둥보강재가 적용된 플레이트 거더의 뒤틀림 강도)

  • Cheon, Jinuk;Lee, Senghoo;Baek, Seungcheol;Kim, Sunhee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.577-585
    • /
    • 2023
  • Lateral torsional buckling causessafety accidentssuch as collapse accidents during erection. Therefore, anaccurate safety designshould be conducted. Lateral torsional buckling canbe prevented by reinforcing the end orreducing the unbraced length. The method ofreducing the unbraced length by installing a crossframe has high material and installation costs and low maintenance performance.In addition, structuralsafety may be deteriorated due to cracks. The end reinforcement method using Concrete Filled Half Pipe Stiffeneris a method ofreinforcing the end of a plate girder using a stiffenerin the form of a semi-circular column. This method increasesthewarping strength ofthe girder and increasesthe lateral torsional buckling strength.In thisstudy, the effect ofincreasing the warping strengthof plate girders with concrete filled half pipe stiffeners was confirmed. To verify the effect, the results ofthe designequationand the finite element analysis were compared and verified through a experiment. As a result, the plate girderwithCFHPS increased thewarping strengthand confirmed that the lateral torsional buckling strength was increased.

Evaluation of Load-Carrying Capacity Loss due to Corrosion in Thin-Walled Section Steel Members (판폭두께비가 큰 휨부재의 부식발생에 따른 구조성능평가에 관한 연구)

  • Chung, Kyung Soo;Park, Man Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.6
    • /
    • pp.619-626
    • /
    • 2009
  • The use of thin-walled flexural members has proven to be a practical way to achieve the lowest cost in the construction of prefabricated long-span, low-rise building frames in steel. On the other hand, most of these structures are subjected to corrosion due to environmental exposure, which can reduce their carrying capacity. Corrosion damage is a serious problem for these structures as it causes thickness loss. That is, the class of a section (plastic, compact, non-compact, or slender) may change from one to another due to the loss of thickness of the compression flange and web due to corrosion. In this study, the effects of corrosion on thin-walled members in long-span steel frames were evaluated with regard to the moment-rotation curve, initial stiffness, maximum load capacity, stiffness in the post-maximum capacity, and energy absorption.

Seismic Behavior and Performance Evaluation of Uckling-restrained Braced Frames (BRBFs) using Superelastic Shape Memory Alloy (SMA) Bracing Systems (초탄성 형상기억합금을 활용한 좌굴방지 가새프레임 구조물의 지진거동 및 성능평가)

  • Hu, Jong Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.875-888
    • /
    • 2013
  • The researches have recently progressed toward the use of the superelastic shape memory alloys (SMAs) to develop new smart control systems that reduce permanent deformation occurring due to severe earthquake events and that automatically recover original configuration. The superelastic SMA materials are unique metallic alloys that can return to undeformed shape without additional heat treatments only after the removal of applied loads. Once the superelastic SMA materials are thus installed at the place where large deformations are likely to intensively occur, the structural system can make the best use of recentering capabilities. Therefore, this study is intended to propose new buckling-restrained braced frames (BRBFs) with superelastic SMA bracing systems. In order to verify the performance of such bracing systems, 6-story braced frame buildings were designed in accordance with the current design specifications and then nonlinear dynamic analyses were performed at 2D frame model by using seismic hazard ground motions. Based on the analysis results, BRBFs with innovative SMA bracing systems are compared to those with conventional steel bracing systems in terms of peak and residual inter-story drifts. Finally, the analysis results show that new SMA bracing systems are very effective to reduce the residual inter-story drifts.

Evaluation of Steel Plate Reinforced Concrete Panels under In-plane Shear (SC구조 평판의 면내전단내력 평가)

  • Lee, Myung Jae;Lee, Hyun Wook;Jin, Seong Chan
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.571-581
    • /
    • 2008
  • The steel plate reinforced concrete structure(SC structure) is suggested for the reasons of the saving of construction period, the saving of manpower and the advantage of quality control. The objective of this study is to evaluate basic structural behavior of SC structure under pure shear load, and shear with axial load condition and to suggest the method of in-plane pure shear loading. From the test results, structural behaviors of SC structure under pure shear load and shear with axial load were investigated the combination of validity of pure shear loading method by using 4 hinge frames was verified.

Nonlinear Thermo-mechanical Analysis Considering Heat Flow under Fire Conditions (화재 열 유동을 고려한 구조물의 열응력해석)

  • Pak, Hongrak;Kang, Jun Won;Lee, Jinwoo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.4
    • /
    • pp.369-376
    • /
    • 2016
  • In this study, a numerical analysis framework for investigating the nonlinear behavior of structures under fire conditions is presented. In particular, analysis procedure combining fire-driven flow simulation and thermo-mechanical analysis is discussed to investigate the mechanical behavior of fire-exposed representative volume structures made of steel and concrete, respectively. First of all, fire-driven flow analysis is conducted using Fire Dynamics Simulator(FDS) in a rectangular parallelepiped domain containing the structure. The FDS simulation yields the time history of temperature on the surface of the structure under fire conditions. Second, mechanical responses of the fire-exposed structure with respect to prescribed uniformly distributed loads are calculated by a coupled thermo-mechanical analysis using the time-varying surface temperature as boundary conditions. Material nonlinearities of steel and concrete have been considered in the thermo-mechanical analysis. A series of numerical results are presented to demonstrate the feasibility of the multiphysics structural fire analysis for investigating the structural behavior under fire conditions.

An Experiment Study on Verification for the Performance of Seismic Retrofit System Using of Dual Frame With Different Eigenperiod (진동주기가 다른 듀얼프레임을 이용한 내진보강시스템의 성능검증을 위한 실험적 연구)

  • Oh, Sang-Hoon;Choi, Kwang-Yong;Ryu, Hong-Sik;Kim, Young-Ju
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.91-100
    • /
    • 2018
  • The new seismic retrofit system in study propose is the Dual system, which aims to be applied to the seismically vulnerable low-story buildings. The Dual system is composed of existing structure, external retrofit frame and hysteretic steel dampers installed between former two components. The Dual system dissipates the energy by plastic deformation of steel damper caused by relative displacement due to the differences in stiffness, weight, and eigenperiod of each components. The dynamic test with shaking table was performed to verify the seismic performance of the proposed Dual system. As a result of the dynamic test, it is expected that the Dual system will improve the seismic performance due to the reduction of strain of 56% and the damage reduction of 93%, even though the energy is 1.84 times higher than that of the dual system. And the results of the study are presented as basic data of the study for setting the design range of the dual system.

Structural Performance Analysis of New Type CFTA Girder Bridge (신형식 CFTA 거더 교량의 구조성능평가)

  • Lee, Ji-O;Jeong, Min-Chul;Park, Kyung-Hoon;Kong, Jung-Sik
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • In this research, static load test is performed to verify the arch effect and structural performance of CFTA(Concrete-Filled and Tied steel tubular Arch) girder, and FE(Finite Element) analysis is performed to investigate validity of the test result. CFTA girder is designed to maximize the benefit of each material, such as steel plate, filled concrete and PS tendon. Static load test is performed based on the frame-analysis result of 12m sample miniature model. The result of static load test is that structural performance and safety of CFTA girder are confirmed and there is different deflection mode with other structural form result from arch effect. FE analysis with ABAQUS is also performed to show the validity of the truck collision safety and static load test.

Minimum Weight Design for Web Frames of Cargo Tanks in the LPG Carrier (LPG 운반선 화물창의 웨브 프레임 최소중량설계)

  • Park, Myeong-Chul;Shin, Sang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.103-108
    • /
    • 2020
  • Generally, the cargo tank of LPG carriers corresponds to an independent tank Type A defined by the International Maritime Organization (IMO). The outside of the tank is insulated by polyurethane foam, and the tank is made of expensive low temperature steel that can withstand temperatures as low as -50℃. The cargo tank is composed of outer shell plates, bulkheads, stiffeners, web frames, and stringers. Among them, the outer shell plates, bulkheads, and stiffeners can be designed without structural analysis by the Classification Rules and are constructed easily through optimal design. On the other hand, optimal design, including numerous structural analysis, is not performed because web frames and stringers should be designed and approved through structural analysis. Only adequate design, which determines the design dimensions through several dozen structural analysis, is performed. In this study, for finite element analysis, eight loading conditions were applied, and the deformation of the entire ship for each loading condition was considered. The minimum weight design was performed for the web frames of cargo tanks in the 82,000 ㎥ LNG carrier through the gradient-based optimization technique, and the weight was reduced by approximately 108 tons per ship.

Ultimate Strength Interaction of Steel Tubular T-Joint Subjected to Concurrent Action of Compression and Bending (압축과 휨을 동시에 받는 강관 T조인트 극한강도 상호작용)

  • Kim, Kyung-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.298-303
    • /
    • 2016
  • Owing to the advantages of reduced weight and wind effect, the space-framed towers that consist of vertical and horizontal members of circular hollow tubular sections have been adopted widely for various purposes. It is critical to guarantee the strengths of tubular joints where vertical and horizontal members are connected structurally to make the entire space-framed system behave as a single tower structure. In this study, a strength evaluation was conducted for T-type tubular joints subjected to the concurrent action of compression and bending. Three of the available design codes, i.e., AISC, Eurocode 3, ISO 19902 were investigated and a design equation was suggested for an ultimate strength interaction between the axial force and bending moment based on nonlinear finite element analyses by selecting the slenderness ratios at the joints as major parameters.

Evaluation of Structural Behavior of Tapered Member with Snug-tightened Flush End-plate Connection (밀착조임 볼트체결방법에 따른 엔드플레이트 접합부의 구조성능평가)

  • Chung, Kyung-Soo;Kim, Woo-Sik;Park, Man-Woo;Do, Byung-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.2
    • /
    • pp.121-128
    • /
    • 2010
  • The current trends in steel construction involve the use of tapered sections to minimize the use of excess materials to the extent possible, by choosing cross-sections that are as economical as possible abandoning the classical approach of using prismatic members. In addition, snug-tightened connections, especially the end-plate type, have the advantage of fetching less construction costs and shorter assembly times as opposed to fully tightened joints. Although they have many merits, however, snug-tightened bolted end plates are extremely complex in their structural behavior. In this study, an experimental investigation of the snug-tightened flush end-plate connections of tapered beams were conducted. The primary test parameters were the torque for the clamping bolt, the loading pattern, the bolt type and the connection failure type. Using initial stiffness and load-carrying capacity as proposed by Silva et al. and AISC (2003), the moment-rotation curve of a linearly tapered member with a snug-tightened flush end-plate connection was predicted. Moreover, numerical and experimental data for moment-rotation curves were compared.