• Title/Summary/Keyword: 강섬유보강 숏크리트

Search Result 30, Processing Time 0.022 seconds

The Strength Characteristic of Shotcrete Reinforced with Improved Shape Steel Fiber (형상을 개선한 강섬유보강 숏크리트의 강도특성)

  • Kim, Sang-Hwan;Park, Inn-Joon;Kim, Ji-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.12
    • /
    • pp.127-136
    • /
    • 2011
  • The laboratory tests were performed to investigate the strength characteristic of shotcrete reinforced with improved shape steel fiber developed in this study. Two different type of tests, the flexural toughness test and the bending strength test, were conducted for analyzing shotcrete strengths using three types of specimens (unreinforced shotcrete, exiting steel fiber reinforced shotcrete, and new concept steel fiber reinforced shotcrete). The results of tests represented the advancement of the strength characteristic of shotcrete reinforced with improved shape steel fiber with respect to that of shotcrete reinforced with existing steel fiber.

A fundamental study on the field applicability of the improved shape steel fiber shotcrete (형상을 개선한 강섬유보강 숏크리트의 현장 적용성에 관한 기초적 연구)

  • Kim, Sang-Hwan;Heo, Chung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.1
    • /
    • pp.59-68
    • /
    • 2013
  • This paper presents the fundamental study on the field applicability of new-type steel fiber improved the existing shape. In this study, the theoretical reviews and the laboratory test programs were carried out to evaluate the mechanical characteristic of the new-type of steel fiber. The steel fiber sticking coefficient of new-type steel fiber was estimated from the test results. The laboratory scaled shotcrete rebound tests were also performed to analysis the field applicability of New-type steel fiber shotcrete and the mechanical behaviour of New-type steel fiber shotcrete were compared with that of the existing steel fiber shotcrete. It was found that the strength characteristic of New-type steel fiber shotcrete was increased.

An Experimental Study on the Silica Fume and Steel Fiber Reinforced Shotcrete (실리카흄 및 강섬유보강 숏크리트의 실험적 연구)

  • 오병환;박칠림;백신원;장성욱
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.119-124
    • /
    • 1992
  • 최근들어 고속도로, 고속철도,지하철 등의 건설이 급격히 증가함에 따라 터널의 건설이 늘어나고 있다. 이러한 터널등의 건설에서 필수적으로 따르는 것이 숏크리트의 시공이며 이러한 숏크리트의 시공은 앞으로 더욱 증가할 추세에 있다. 그러나 숏크리트의 광범위한 시공에도 불구하고 현재 여러 가지 문제점을 내포하고 있는 것이 사실이다. 따라서 본 연구에서는 우리나라 현행 숏크리트의 현황과 문제점을 도출하여 성능개선을 위한 최적 배합을 도출하고 고품질의 숏크리트 시공을 위하여 실리카퓸 숏크리트의 개발 및 적용과 인성(Toughness)과 연성(Ductility)을 대폭 증가시키고 시공속도를 빠르게 하여 안전성과 함께 경제성을 확보할 수 있는 강섬유보강 숏크리트의 개발 및 적용에 대한 연구를 집중적을 수행하였다. 본 연구로부터 숏크리트의 최적 배합을 도출하였고 강도와 내구성을 함께 증가시키고 리바운드율을 대폭 감소시킬 수 있는 실리카퓸 숏크리트를 개발하였다. 또한 wiremesh를 대체할 수 있는 강섬유보강 숏크리트를 개발하여 실내시험 및 현장 적용성 시험을 수행하였다.

  • PDF

A Study on the Reasonable Application Method of Steel Fiber Reinforced Shotcrete in NATM Tunnel (NATM 터널에서 합리적인 강섬유보강 숏크리트 적용방안에 관한 연구)

  • Seok, Chongken;Ahn, Taebong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.9
    • /
    • pp.19-28
    • /
    • 2014
  • Recently, the proportion of long tunnel has increased for efficient use of land due to limited land area, driving convenience and high speed. RMR and Q-System of empirical methods has been mainly used for tunnel support design in domestic. Although shotcrete is the key to NATM tunnel, the related studies are insufficient. So, steel fiber reinforced shotcrete is applied to II~V grade rocks on domestic and foreign applications. And same amount of shotcrete is equally applied to tunnel roof and wall regardless of the applied rock load. Shotcrete is applied excessively rather than the original proposed value of RMR and Q-System. Thus, this study is to reevaluate the application part of plain shotcrete and steel fiber reinforced shotcrete of tunnel in Daebo granite, and to propose the reasonable application method of steel fiber reinforced shotcrete. Field test and numerical back analysis using measurements were performed to verify stability. According to results, if RMR values are the upper class in the III grade, it can be designed in accordance with upper grade. In addition, if rock condition is good as a mountain tunnel in Daebo granite, it can be applied for plain shotcrete to III grade rocks because there is also no stability problems. And although steel fiber reinforced shotcrete is applied only crown of the tunnel in IV grade rocks, it is possible to secure stability for falling rock by key-block.

Experimental Construction of Polyamide Fiber Reinforced Shotcrete Technology (다발형 폴리아미드섬유 보강 숏크리트 현장 적용성 평가)

  • Yoon, Ji-Hyun;Jeon, Joong-Kyu;Jeon, Chan-Ki;Lee, Soo-Choul
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.2
    • /
    • pp.78-83
    • /
    • 2012
  • Steel fiber reinforced shotcrete in tunneling construction has some problems in terms of constructability, durability and lots of rebound wastage. In order to resolve these problems, this pater proposes polyamide fiber reinforced shotcrete technology. And this paper presents the results of experimental construction of the polyamide fiber reinforced shotcrete technology. The results of the study are as follows. 1. The polyamide fiber reinforced shotcrete suggested in this paper shows outstanding mechanical performance that meets various Korean tunnel construction design criteria. 2. In addition, the results of experimental constructions show that the polyamide fiber reinforced shotcrete creates less rebound and wasted product than the steel fiber reinforced shotcrete. Based on the above results, it is concluded that the polyamide fiber reinforced shotcrete technology can be used as economical and environmentally friendly construction of tunnel.

  • PDF

A study on the flexural toughness characteristics of the half-circle type steel fiber reinforced shotcrete (반원형 강섬유보강 숏크리트의 휨인성 특성에 관한 연구)

  • Ji, Young-Hwan;Jeong, Ji-Su;Jeong, Chun-Kyo;Lee, Seung-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.2
    • /
    • pp.83-96
    • /
    • 2011
  • Currently, the commonly used tunneling method in Korea is NATM (New Austrian Tunneling Method). This method uses the rock bolt, shotcrete, and supporting system to maintain the strength of original soil and ensures the stability of tunnel by stabilizing the soil using the original strength of the soil in maximum after the excavation. In past years, wire-mesh reinforced shotcrete was common ones but currently steel-fiber reinforced shotcrete is being widely used for the tunnel construction site in Korea to save construction time with the advanced construction technology. The results further indicate that needs for the establishment of not only the specifications for shotcrete but the strengthening methods for the under reinforced shotcrete sections. Therefore, this study deals with the development of a new steel-fiber to ensure the stability of tunnels that are under reinforced with steel-fibers and to overcome the shortcomings of conventional method.

Flexural Behavior Evaluation of Two Types Fiber Reinforced Shotcrete using Round Panel Test (원형패널 시험을 활용한 두 종류 섬유 보강 숏크리트의 휨거동 평가)

  • Jeon, Chanki;Jeon, Joongkyu
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.4
    • /
    • pp.607-614
    • /
    • 2015
  • This study evaluated the flexural performance of steel and PP fiber reinfroced shotcrete using round panel test according to ASTM that can consider the actual stress of fiber reinforced shotcrete in tunnel and under ground structures. The results of round panel test are converted to the square panel test results according to the EFNARC. The energy absorptions of each fiber reinforced shotcrete were classified according to the EFNARC toughness classification. Test results show that the PP fiber reinforced shotcrete has better flexural performance compared with the steel fiber reinforced shotcrete.

Properties of Advanced Synthetic Fiber Reinforced Concrete for Improvement of Tunnel Shotcrete Performance (터널 숏크리트 성능 향상을 위한 고기능성 합성섬유 보강 콘크리트의 물성 평가)

  • Jeon, Chanki;Jeon, Joongkyu
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.1
    • /
    • pp.43-50
    • /
    • 2011
  • The Application of Steel Fiber Shotcrete in tunneling construction has become part of tunneling practice at least since the 1970s because of its high bending and tensile properties. Over the past 3 decades, researcher from all over the world have been significantly developing the associated technologies for improved performance of SFRS. But still it has some major drawbacks in terms of durability, damage of pumping hose, wastage due to rebound concrete, corrosion and it costs high. To overcome this situation researcher has to look for some alternative material. Therefore, this part study deals with the three types of fiber in order to find good alternative for steel fiber. Polyamide and Polypropylene fiber were used in this study with 0.6, 0.5% mixing ratio. To evaluate its fresh and harden properties air content, slump, compressive, split tensile and bending strength were measured. After comparing the results of all three types of fiber reinforced concrete with its different mixing proportion this study propose that polyamide fiber with addition ratio of 0.6 % for field use.

A study on evaluation of flexural toughness of synthetic fiber reinforced shotcrete (구조용 합성섬유 보강 숏크리트 휨인성 평가에 관한 연구)

  • Moon, Kyoung-Sun;Kim, Seog-Jin;Kim, Yeon-Deok;Min, Byeong-Heon;Kim, Sang-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.3
    • /
    • pp.433-452
    • /
    • 2019
  • This study deals with shotcrete reinforcing performance according to the amount of synthetic fiber (PP fiber) and proper evaluation method. The shotcrete compressive strength, flexural strength and flexural toughness were tested by setting the mixing amounts of steel fiber ($37.0kg/m^3$) and synthetic fiber (PP fiber) as parameters ($5.0kg/m^3$, $7.0kg/m^3$ and $9.0kg/m^3$). Particularly, circular panel flexural toughness test (Road and Traffic Authority, RTA) was performed to evaluate the shotcrete energy absorption capacity. As a result, the compressive strength and the bending strength of the steel fiber reinforced shotcrete were large, but the flexural toughness of the synthetic fibe (PP fiber) reinforced shotcrete was large. Therefore, synthetic fiber (PP fiber) reinforced shotcrete is considered to have a reinforcing effect comparable to that of steel fiber reinforced shotcrete. Analysis of the relationship between the flexural toughness and the energy absorption capacity of synthetic fiber (PP fiber) reinforced shotcrete revealed that the energy absorbing ability is exhibited at a flexural toughness lower than the allowable standard (3.0 MPa). (Class A: 2.55 MPa = 202J, Class B: 2.72 MPa = 282J, Class C: 3.07 MPa = 403J). As a result of this study, it can be concluded that the actual shotcrete support performance can be evaluated by evaluating the support performance of the shotcrete measured at less than the allowable standard (3.0 MPa) at the actual tunnel site.

Application of New Type Accelerator for High Quality Shotcrete (고품질 숏크리트 개발을 위한 새로운 급결제 적용)

  • Park, Hae-Geun;Lee, Myeong-Sub;Kim, Jea-Kwon;Jung, Myung-Keun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.1
    • /
    • pp.45-55
    • /
    • 2002
  • From the early 1980's, the New Austrian Tunnelling Method (NATM) has been developed as one of the standard tunnelling methods in Korea. Approximately 10 years ago, wet-mix shotcrete with sodium silicate (waterglass) accelerator was introduced and widely used to tunnel lining and underground support. However, this accelerator had some disadvantages due to the decrease of long-term strength compared to plain concrete (without accelerator) and low quality of the hardened shotcrete. In order to compensate for these disadvantages, recently developed alkali-free accelerator has been successfully demonstrated in numerous projects and applications as a new material to make tunnels more durable and safer. An experimental investigation was carried out in order to verify the strength behavior of wet-mix Steel Fiber Reinforced Shotcrete (SFRS) with alkali-free accelerator. Compressive strength, flexural strength, and flexural toughness were measured by testing specimens extracted from the shotcrete panels. From the results, wet-mix SFRS with alkali-free accelerator exhibited excellent strength improvement compared to the conventional shotcrete accelerator.

  • PDF