• Title/Summary/Keyword: 감응센서

Search Result 228, Processing Time 0.029 seconds

The fabrication and sensing characteristics of conducting polymer sensors for Measurement of VOCs (Volatile organic compounds) gas (휘발성 유기 화합물 가스 측정을 위한 전도성 고분자 센서의 제조(製造) 및 감응(感應) 특성(特性))

  • Paik, J.H.;Hwang, H.R.;Roh, J.G.;Huh, J.S.;Lee, D.D.;Lim, J.O.;Byun, H.G.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.125-133
    • /
    • 2001
  • Conducting polymer sensors show high sensitivity when exposed to volatile organic compounds gases at room temperature. The 8 sensor array using by polypyrrole and polyaniline has been fabricated by chemical polymerization for measuring sensing characteristics of VOCs gases. Conducting polymer was polymerized by using distilled pyrrole, aniline as a monomer and ammonium persulfate (APS) as an oxidant and dodecylbenzene sulfonic acid (DBSA) as a dopant. Dedoped film was synthesized by reverse voltage and redoped film was synthesized by using 1-octanesulfonic acid sodium salt as another dopant in electrochemical cell. The sensitivity and reversibility were influenced by doping, dedoping, redoping and thickness for the polypyrrole and polyaniline. We investigated the relation between the structure of conducting polymer and sensitivity of these sensors through the analysis of scanning electron microscope (SEM), scanning probe microscope (SPM) and $\alpha$-step.

  • PDF

The Study on development of a SAW SO$_2$ gas sensor (표면탄성파를 이용한 아황산 가스센서 개발에 관한 연구)

  • Lee, Young-Jin;Kim, Hak-Bong;Roh, Yong-Rae;Cho, Hyun-Min;Baik, Sung;,
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.89-94
    • /
    • 1997
  • A new type SO$_2$ gas sensor with a particular inorganic thin film on SAW devices was developed. The sensor consisted of twin SAW oscillators of the center frequency of 54 MHz fabricated on the LiTaO$_3$ piezoelectric single crystal. One delay line of the sensor was coated with a CdS thin film that selectively adsorbed and desorbed SO$_2$, while the other was uncoated for use as a stable reference. Deposition of the CdS thin film was carried out by the spray pyrolysis method using an ultrasonic nozzle. The sensor could measure the concentration in air less than 0.25 parts per million of SO$_2$. Stability of the sensor turned out to be as good as less than 20ppm, recovery time after each measurement was as short as 5 minutes. Repeatability of the measurement was confirmed through so many reiterated experiments. Hence, the SAW sensor developed through this work showed promising performance as a microsensing tool of SO$_2$. Further work required to improve the performance of the sensor includes enhancement of the reactivity of the CdS thin film with SO$_2$ through appropriate dopant addition, an increase of the center frequency of the SAW device.

  • PDF

Disposable Glucose Sensor Based on Platinised Carbon Paste Electrode (백금 도금된 탄소반죽 전극을 이용한 일회용 글루코오스 센서)

  • Lee Dong Joo;Yoo Jae Hyun;Cui Gang;Choi Moon Hee;Kim Moon Hwan;Ryu Joon Oh;Han Sang-Hyun;Cha Geun Sig;Nam Hakhyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.4
    • /
    • pp.227-231
    • /
    • 1999
  • Disposable, amperometric glucose sensor was constructed using platinised carbon paste electrode. The sensor response was studied by amperometry and cyclic voltammetry applying sample solutions on the strip-type electrode. Platinization of screen-printed carbon paste electrode effectively improved the electrochemical reversibility of a mediator and the analytical characteristics of the sensor. The heterogeneous rate constant for $[Fe(CN)_6]^{4-/3-}$ was $1.45\times10^{-2}cm{\cdot}s^{-1}$. An applied potential of 0.3V vs. Ag/AgCl resulted in the best selectivity for glucose. The apparent Michaelis-Menten constant for glucose on the strip sensor, $K_m^{app}$, was 24.5 mM. To evaluate the analytical performance of the glucose sensor strip, a correlation study was performed with the NOVA S.P, Ultra M analyzer for 30 serum samples containing $80\~297mg/dL$ of glucose: the correlation coefficient value was 0.983. It can be seen that the strip sensor has satisfactory precision and accuracy.

Analysis of Aroma Pattern of Gastrodiae Rhizoma by the Drying Conditions (건조 방법에 따른 천마의 향기패턴 분석)

  • Lee, Boo-Yong;Yang, Young-Min;Han, Chan-Kyu
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.13-17
    • /
    • 2002
  • The study was to analyze aroma patterns of Gastrodiae Rhizoma by the electronic nose with conducing polymer 32 sensors. Response by the electronic nose was analyzed by the principal component analysis (PCA). Sensory evaluation for the organoleptic characteristics of Gastrodiae Rhizoma was also performed. Raw Gastrodiae Rhizoma was very intensive in overall odor and taste. Hot air-dried $60^{\circ}C$ Gastrodiae Rhizoma was relatively weak in overall odor and taste. Intensity of aroma in the electronic nose was the highest in $60^{\circ}C$ hot air-dried Gastrodiae Rhizoma. As quality factor (QF) calcuated from PCA map of normalized pattern data by thirty two sensors showed less than 2, and so aroma pattern among raw, freezed-dried, and hot-air dried Gastrodiae Rhizoma had no difference. When PCA was performed for normalized pattern data by the selected sensitive ten sensors, QF value between raw and $60^{\circ}C$ hot air-dried Gastrodiae Rhizoma was 2.366. Thus aroma pattern of raw and $60^{\circ}C$ hot air-dried Gastrodiae Rhizoma was discriminated in electronic nose.

Development of a cholesterol biosensor modified with carbon nanotube (탄소나노튜브를 이용하여 개조한 콜레스테롤 바이오 센서 개발)

  • Kim, Haidong
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.425-429
    • /
    • 2015
  • A cholesterol biosensor was developed using a modified carbon electrode with carbon nanotubes. The disposable cholesterol biosensor was modified with carbon nanotubes to enhance electron transfer during the enzymatic reaction of cholesterol. Cholesterol oxidase and peroxidase, with potassium ferrocyanide as a mediator, were immobilized on a screen-printed carbon nanotube electrode. The electrochemical cholesterol biosensor developed using carbon nanotubes showed a rapid and reliable signal for measuring total cholesterol. The cholesterol sensor showed a linear response in 5 seconds with a small volume (0.5 μL) in the range of 100~400 mg/dL, with a coefficient of variation of 4.0%.

A Study on the Measurement of Spectral Response Characteristics of Color Image Sensor (칼라영상센서의 분광감도 측정에 관한 연구)

  • 박승옥;김홍석
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.266-273
    • /
    • 1995
  • Colors reproduced by color imaging system are affected by various physical factors. The spectral response of the color image sensor is one of the important factors. We developed a spectral response characteristics measurement system which is composed of optical part and color analyzing part. The data from the optical part was analyzed by the color analyzing part and spectral response characteristics of R, G, B three color sensors were obtained. Using this system, the spectral response characteristics of a CCD color camera was measured. From this result, color rendition and linearity of the camera could be analyzed. This measurement system is $.$considered to be very useful for the evaluation of color image sensor characteristics. stics.

  • PDF

Fabrication and NOx Sensing Characteristics of $WO_{3}$ Based Thick Film Devices Doped with $TiO_{2}$ and Noble Metals ($TiO_{2}$와 귀금속을 첨가한 $WO_{3}$ 후막 센서의 제조 및 NOx 감응 특성)

  • Lee, Dae-Sik;Han, Sang-Do;Son, Young-Mok;Lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.274-279
    • /
    • 1997
  • NOx sensors using tungsten oxide films as a base material were prepared and their electrical and sensing characteristics have been investigated. The $WO_{3}$ thick films doped with $SnO_{2}$ or $TiO_{2}$ showed higher sensitivity and better sorption characteristics to NOx gas than the pure $WO_{3}$ films material in air at operating temperature of $400^{\circ}C$. By addition of noble catalysts, such as Ru or Au, to the $TiO_{2}-WO_{3}$ thick films, their sensitivity, recovery and selectivity to NOx gas were found to be more enhanced.

  • PDF

The Electrochemical Studies of Non-enzymatic Glucose Sensor on the Nickel Nanoparticle-deposited ITO Electrode (ITO 전극 위에 고정된 니켈 나노 입자를 이용한 무효소 혈당센서에 관한 전기화학적인 연구)

  • Oh, In-Don;Kim, Samantha;Choi, Young-Bong
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.3
    • /
    • pp.164-171
    • /
    • 2014
  • A highly sensitive and selective non-enzymatic glucose sensor has gained great attention because of simple signal transformation, low-cost, easily handling, and confirming the blood glucose as the representative technology. Until now, glucose sensor has been developed by the immobilization of glucose oxidase (GOx) on the surface of electrodes. However although GOx is quite stable compared with other enzymes, the enzyme-based biosensors are still impacted by various environment factors such as temperature, pH value, humidity, and toxic chemicals. Non-enzymatic sensor for direct detecting glucose is an attractive alternative device to overcome the above drawbacks of enzymatic sensor. Many efforts have been tried for the development of non-enzymatic sensors using various transition metals (Pt, Au, Cu, Ni, etc.), metal alloys (Pt-Pb, Pt-Au, Ni-Pd, etc.), metal oxides, carbon nanotubes and graphene. In this paper, we show that Ni-based nano-particles (NiNPs) exhibit remarkably catalyzing capability for glucose originating from the redox couple of $Ni(OH)_2/NiOOH$ on the surface of ITO electrode in alkaline medium. But, these non-enzymatic sensors are nonselective toward oxidizable species such as ascorbic acid the physiological fluid. So, the anionic polymer was coated on NiNPs electrode preventing the interferences. The oxidation of glucose was highly catalyzed by NiNPs. The catalytically anodic currents were linearly increased in proportion to the glucose concentration over the 0~6.15 mM range at 650 mV versus Ag/AgCl.

Planar microchip-based lactate biosensor (평면 소자형 락테이트 바이오센서)

  • Ha, Jeonghan;Huh, Hwang;Kang, Tae Young;Lee, Yong Seok;Yoon, Soon Ho;Shin, Jungwon;Nam, Hakhyun;Cha, Geun Sig
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.482-489
    • /
    • 2006
  • Two electrode-based lactate biosensor was prepared by immobilizing lactate oxidase (LOD) obtained from pediococcus species in a poly(vinyl alcohol). Hydrogen peroxide ($H_2O_2$) produced by the reaction of lactate and LOD was detected on the Pt-black that was electrochemically deposited on the Au electrode. Sensors fabricated with Pt-black deposited Au electrode provided a high current of $H_2O_2$ oxidation at a substantially lowered applied potential (+300 mV vs. Ag/AgCl), resulting in reduced interferences from easily oxidizable species such as ascorbic acid, acetaminophen, and uric acid. An outer membrane is formulated by adjusting water uptake of hydrophilic polyurethane (HPU). The sensor performance was evaluated in vitro with both flow-through arrangement and static mode. The sensor showed a linear range from 0.1 mM to about 9.0 mM in 0.05 M phosphate buffer (pH 7.6) containing 0.05 M NaCl. Storing the sensors prepared in this work at $4^{\circ}C$ buffer solution while not in use, they provided same electrochemical performance for more than 25 days.

A Touch-sensitive Display with Embedded Hydrogenated Amorphous-silicon Photodetector Arrays (비정질 실리콘 광센서를 이용한 터치 감응 디스플레이 설계 및 제작)

  • Lee, Soo-Yeon;Park, Hyun-Sang;Han, Min-Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2219-2222
    • /
    • 2009
  • A new touch-sensitive hydrogenated amorphous silicon(a-Si:H) display with embedded optical sensor arrays is presented. The touch-sensitive panel operation was successfully demonstrated on a prototype of 16-in. active-matrix liquid crystal display (AMLCD). The proposed system provides the finger touched point without the real-time image processing of information of the captured images. Due to the simple architecture of the system, we expect the introduction of large-area touch-sensitive display panels.