• Title/Summary/Keyword: 감마 과정

Search Result 166, Processing Time 0.025 seconds

Analysis of 226Ra in the Groundwater Using the Gamma-ray Spectroscopy (감마선 분광법을 이용한 지하수 중의 226Ra 분석)

  • Seo, Bum-Kyoung;Lee, Kil-Yong;Yoon, Yoon-Yeol;Lee, Kune-Woo
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.39-47
    • /
    • 2003
  • The measurement of radium ($^{226}Ra$) in the groundwater was established using ${\gamma}$-ray spectroscopy without sample preparation. The background interference by air borne radon daughter nuclides was reduced by $N_2$ gas flow into the counting chamber. Leakage of radon gas produced in the radioactive equilibrium with radium and its daughter nuclides was prevented by use of the air-tighted aluminium container. We investigated the effect of air layer in the counting container. Radioactivity variation due to emanation of radon into the air layer was within the counting error range 5%. When the nitrogen gas was flowed around the detector, peak counts of ${\gamma}$-rays from the daughters of airborne radon was decreased and detection limit was decreased to 0.02 Bq/L. The detection limit of detector was lower than 0.74 Bq/L, the $^{226}Ra$ Maximum Contaminant Level (MCL) in the groundwater proposed by US Environmental Protection Agency (EPA). It was confirmed that $^{226}Ra$ radioactivity in the groundwater could be determined by the ${\gamma}$-ray spectroscopy.

Planning Accelerated Degradation Tests: the Case of Gamma Degradation Process (열화가 감마과정을 따르는 경우 가속열화시험의 최적 계획)

  • Lim, Heonsang;Lim, Dae-Eun
    • Journal of Korean Society for Quality Management
    • /
    • v.43 no.2
    • /
    • pp.169-184
    • /
    • 2015
  • Purpose: This paper is concerned with optimally designing accelerated degradation test (ADT) plans based on a gamma process for the degradation model. Methods: By minimizing the asymptotic variance of the MLE of the q-th quantile of the lifetime distribution at the use condition, the test stress levels and the proportion of test units allocated to each stress level are optimally determined. Results: The optimal plans of ADT are developed for various combination of parameters. In addition, a method for determining the sample size is developed, and sensitivity analysis procedures are illustrated with an example. Conclusion: It is important to optimally design ADT based on a gamma process under the condition that a degradation process should be always nonnegative and strictly increasing over time.

A Study on Reproduction of Color Image using Gamma Variation on Display Colorimetric Characterization (디스플레이 특성화과정에서 감마변화를 이용한 컬러이미지 재현에 관한 연구)

  • Lee, Sung-Chul;Cho, Ga-Ram;Koo, Chul-Whoi
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.23 no.1
    • /
    • pp.1-11
    • /
    • 2005
  • The propose of this study investigated the reproduction of color image on a CRT monitor, for a range of different values of monitor gamma. We have used the GOG(gain-offset-gamma) model of the behavior of CRT. Color difference have been computed in a color space, based on the CIELAB color appearance model. The 133 patch defined linearly color sample and 24 patch defined printing color target were used, and were subjected to the influence of nine different gamma value. The result shows that netural color is increasing the decrease range of luminance black color than white color. These results concern correct in the context display of color reproduction.

  • PDF

The implementation of a Gd-pMOSFET thermal neutron detector and the enhancement of its sensitivity (Gd-pMOSFET 열중성자 측정기 구현 및 감도개선)

  • Lee, Nam-Ho;Kim, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.430-432
    • /
    • 2005
  • 저에너지 중성자가 가톨리늄(Gd) 막에 입사되면 중성자 포획과정에서 전환전자가 생성된다. 이 전환전자에 의해 pMOSFET $SiO_2$ 산화층에서 발생된 전자-전공쌍이 발생되고, 이 가운데 정공은 산화층 내부에 쉽게 붙잡혀(Trap) 양전하 센터로 작용하게 된다. 이 축적된 전하는 pMOSFET의 문턱전압(Threshold voltage)을 변화시킨다. 본 연구에서는 이러한 간접측정 원리를 이용하여 열중성자를 실기간 탐지할 수 있는 반도체형 탐지소자를 개발하고 하나로(HANARO) 방사선장에서의 시험을 통해 성능을 검증하였다. 그리고 감도관련 변수의 최적화를 통하여 작업자가 사용 가능한 범위의 고감도 열중성자 선량계로 개선 제작하였다. 개발된 선량계는 소형으로 실시간 열중성자 측정이 가능하며 감마방사선으로부터 독립적으로 열중성자를 측정할 수 있는 장점도 지니고 있다.

  • PDF

DUPIC 핵연료 보장조치용 중성자측정장치 개발(II)

  • 이영길;차홍렬;김호동;강희영;홍종숙
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.356-361
    • /
    • 1997
  • DUPIC 공정의 핵연료에 대핀 핵물질 보장조치(safeguards)를 이행하여 핵투명성(nuclear transparency)을 검증하기 위한 중성자측정장치를 개발하였다. 본 장치를 사용한 보장조치 원리 및 기술적 사항, 장치 설계 개념 등에 관해서는 본 논문의 전편$^{[1]}$ 에서 기술하였고 여기서는 제작된 측정장계에 대한 성능시험 내용을 중심으로 나타내었다. 즉, 일반시설(cold lab.)내에서 실시한 성능시험 결과로부터 장치의 각 부분별 기능이 정상적으로 작동되고 있음을 확인할 수 있었으며 이것은 현재 후속과정으로 핫셀(hot cell)내에서 사용후핵연료를 이용하여 수행중인 성능시험 결과를 분석하는 기본자료로 활용될 것이다. 본 장치 개발을 통하여 확보한 중성자측정 기술은 앞으로 고준위감마선방출 핵물질을 사용하는 후행핵연료주기 시설에 대한 핵물질 통제 및 계량관리에 필요한 보장조치 기술로 활용될 수있을 것으로 기대된다..

  • PDF

Evaluation of 226Ra analysis methods using a gamma-ray spectrometer and a liquid scintillation counter (감마선분광분석기와 액체섬광계수기를 이용한 226Ra 분석법 비교 연구)

  • Ju, Byoung Kyu;Kim, Moon Su;Kim, Hyun Koo;Kim, Dong Su;Cho, Sung Jin;Yang, Jae Ha;Park, Sun Hwa;Kim, Hyoung Seop;Kwon, Oh Sang;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • The efficiency and applicability of the solid phase extraction disk method in a 226Ra analysis were examined by the gamma ray spectrometer (GRS) method using a Marinelli beaker and the liquid scintillation counter (LSC) method for groundwater. The recovered 226Ra, which was filtered by the solid phase extraction disk, was analyzed using gamma ray spectrometer The disks, which were pretreated for caulking the daughter nuclide, were sealed with polyethylene film. Distilled water was used for the blank value of the 226Ra activity. The recovery values of 214Bi and 214Pb in the solid phase extraction disk, which used 226Ra standard material, were 80% (295.21 Kev) and 104% (351.92 Kev), respectively, which were higher than 75% determined by the LSC. The injection of nitrogen gas into the measuring chamber reduced the interference values by about 10%. The detection limits of the 226Ra activity in a blank sample of 5 L were 0.17~0.40 pCi/L after 80,000 seconds of measuring time. The relationship of the 226Ra activity in the solid phase extraction disk method and in the LSC method in seven groundwater samples showed a correlation coefficient value 0.987, which implies the applicability of the solid phase extraction disk method. The results showed that 226Ra activity in groundwater using the solid phase extraction disk method has the following benefits: simple pretreatment, time saving, high recovery values, a low detection limit, and so on. Compared with the LSC method and the GRS method using the Marinelli beaker for the 226Ra analysis, the solid phase extraction disk method could be useful in groundwater samples with low levels of activities of radionuclides because the method is not restricted by the volume of the sample.

Decomposition of 2,4,6-Trinitrotoluene (TNT) by Gamma Ray Irradiation (감마선 조사에 의한 2,4,6-Trinitrotoluene (TNT)의 분해)

  • Lee, Byung-Jin;Lee, Myun-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2005
  • The purpose of this study was to evaluate the potential of a gamma irradiation to decompose 2,4,6-trinitrotoluene(TNT) in an aqueous solution. The decomposition reaction of TNT by gamma irradiation was a pseudo first-order kinetic over the applied initial concentrations($25{\sim}100mg/L$). The dose constant was strongly dependent on the initial TNT concentration. The removal of TNT was more efficient at pH below 3 and at pH above 11 than at neutral pH(pH 5-9). The required irradiation dose to remove over 99% of TNT was 40, 80 and 10 kGy, individually at pH 2, 7 and 13. The dose constant was increased by 1.6 fold and over 15.6 fold at pH 2 and 13, respectively, when compared with that at pH 7 When irradiation dose of 200 kGy was applied, the removal efficiencies of TOC were 91, 46 and 53% at pH 2, 7 and 13, respectively. Ammonia and nitrate were detected as the main nitrogen byproducts of TNT and glyoxalic acid and oxalic acid were detected as organic byproducts. The results showed that a gamma irradiation was an attractive method for the decomposition of TNT in an aqueous solution. However, regarding the application of high energy radiation for the TNT decomposition and mineralization, an application of an acidic pH below 3 to the solution before irradiation should be considered.

Combined Effects of Gamma-irradiation and Hyperthermia on the Human Cell Lines for Various Temperatures and Time Sequences (감마선과 온열치료 병용시 세포 치사 능력 증강에 관한 실험적 연구)

  • Koh Kyung Hwan;Cho Chul Koo;Park Woo Yoon;Yoo Seong Yul;Yun Hyong Geun;Shim Jae Won;Lee Mi Jung
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.51-58
    • /
    • 1993
  • We tried to establish the theoretical basis of clinical use of combined modality of hyperthermia and radiation therapy. For this purpose, we made an in vitro experiment in order to get the synergistic and/or additive effects on the cell killing of hyperthermia combined with radiation therapy by using the microwave-hyperthermia machine already installed at our department. In our experiment, we use two human cell lines: MKN-45 (adenocarcinoma of stomach) and K-562 (leukemia cell lines). In cases of combined treatments of hyperthermia and gamma-irradiation, the therapeutic effect was the highest in the simultaneous trial. Hyperthermia after gamma irradiation showed slightly higher therapeutic effect than that before irradiation without significant difference, but its effect was the same in the interval of 6 hours between hyperthermia and irradiation. The higher temperature and the longer treatment time were applied, the higher therapeutic effects were observed. We could observe the thermoresistance by time elapse at $43^{\circ}C$. When hyperthermia was done for 30 minutes at the same temperature, thermal enhancement ratio (TER) at DO. 01 (dose required surviving fraction of 0.01) were $2.5{\pm}0.08,\;3.75{\pm}0.18$, and $5.0{\pm}0.15\;at\;436{\circ}C,\;44^{\circ}C,\;and\;45^{\circ}C$ respectively in K-562 leukemia cell lines. Our experimental data showed that more cell killing effect can be obtained in the leukemia cell lines, although they usually are known to be radiosensitive, when treated with combined hyperthermia and radiation therapy. Furthermore, our data show that leukemia cell lines may have various intrinsic radiosensitivity, especially in vitro experiments. The magnitude of cell killing effect, however, will be less than that of MKN-45.

  • PDF

Microbiological Contamination of Ice Cream Commercially Available in Korea and its Irradiation Effect (시판 아이스크림의 미생물 오염도 및 감마선 조사효과)

  • Kim, Hyun-Joo;Jo, Cheor-Un;Kim, Dong-Soo;Yook, Hong-Sun;Byun, Myung-Woo
    • Journal of Animal Science and Technology
    • /
    • v.47 no.5
    • /
    • pp.867-876
    • /
    • 2005
  • The microbial contamination of ice cream product commercially available in Korea was determined using ice bar, ice cream, ice milk and non-milk fat ice cream. Irradiation effect on enhancement of microbiological safety was also investigated at doses of 1, 3, and 5 kGy. In all products, yeast and molds were not detected, however, total aerobic and coliform bacteria were detected at 1-2 and 1-1.5 Log CFU/g level, respectively. According to the different flavor used in ice cream, total aerobic bacteria were detected as 2.30, 2.90, and 3.32 Log CFU/g level in vanilla, chocolate, and strawberry ice cream, respectively. Yeast and mold was not detected in vanilla ice cream but 2.30 and 2.70 Log CFU/g in chocolate and strawberry ice cream, respectively. Coliforms were also detected 1-2 Log CFU/g in the ice cream with different flavors. Listeria inocua and Escherichia coli were detected from 3 commercial samples but Salmonella spp. was not detected using API kit. Gamma irradiation significantly reduced the level of the contaminated total aerobic bacteria, yeast and molds and coliform population in the ice creams. These results indicated that irradiation(5kGy or less) is effective to ensure safety of ice cream.

Analysis on Thermal Degradation of Poly($\gamma$-glutamic acid) Sodium Salt by means of Light Scattering and Viscometry (광산란과 점성도법에 의한 폴리감마글루탐산 나트륨 염의 열분해 분석)

  • Park, Il-Hyun;Eom, Hyo-Sang;Kwon, Hyo-Lee
    • Polymer(Korea)
    • /
    • v.33 no.5
    • /
    • pp.501-508
    • /
    • 2009
  • The thermal degradation experiment of sodium salt of poly (${\gamma}$-glutamic acid) (PGGNa) has been carried out in both its solid phase and solution phase at the range of $57{\sim}120^{\circ}C$ and their molecular weight decreasing effect was analyzed as a function of time by means of viscometry and light scattering. Based on the solid phase degradation results, it was supposed that the bond scission rate in a polymer chain kept constant and that the bond scission was occurred on a randomly located position in a polymer chain. For the degradation in solution phase, it was also found that all data at various temperatures were dropped on a single master curve when the reduced time $t/t^*$ was used in the plot of the reciprocal intrinsic viscosity (or molecular weight). This degradation curve in solution phase could be expressed as the sum of a single exponential and a linear equation and especially, the single exponential character appeared only at the beginning stage. The activation energy was measured as $107{\sim}115$ kJ/mol in this study and agreed with the literature values.