A Study on the Secondary Carcinogenesis Rate of Vestibular Schwannoma Disease using Glass Dosimeter (유리선량계를 이용한 청신경초종 질환의 2차 발암률에 관한 연구)

  • Joo-Ah Lee;Gi-Hong Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.243-248
    • /
    • 2023
  • This study aims to analyze the secondary carcinogenesis rate caused by exposure of organs at risk of damage using a glass dosimeter during radiosurgery in vestibular schwannoma disease. Using a pediatric phantom of human tissue equivalent material, the volume of the tumor was set to a total of three volumes: 0.506 cm3, 1.008 cm3, and 2.032 cm3, and a radiosurgery plan was established with an average dose of 18.4 ± 3.4 Gy. After mounting the human body phantom on the table of surgical equipment, glass dosimeters were placed on the right eye, left eye, thyroid gland, thymus, right lung, and left lung to measure the exposure dose, respectively. In this study, the incidence of secondary cancer due to exposure to damaged organs during gamma knife radiosurgery in vestibular schwannoma disease with the largest tumor volume of 2.032 cm3 was measured with a glass dosimeter. This study studies the risk of secondary radiation exposure dose that can occur during stereotactic radiosurgery, and it is considered that it will be used as basic data in the field of radiation damage related to the stochastic effect of radiation in the future.

Physical Aspect of The Gamma Knife and Its Clinical Application (감마나이프의 물리적 특성 및 그의 임상적 적용)

  • Yi Byong Yong;Chang Hyesook;Choi Eunkyung;Whang C. Jin;Kwon Y.
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.153-158
    • /
    • 1991
  • The first Leksell Gamma Knife unit (LGU-type B) for radiosurgery in Asia was installed in Asan Medical Center. Mechanical accuracy, output, dose profiles for each collimators were measure during acceptance test. Sixty eight patients (sixty nine cases) had undergone radiosugery from May 1990 to September 1990. AVM cases were 24 cases $(35\%)$, acoustic tumor 10 $(14\%)$, pituitary adenoma 4 $(6\%)$, metastatic tumor 18 $(26\%)$, meningioma 6$(9\%)$ and others 18 $(25\%)$. Dose of $25\;Gy\sim100\;Gy$ was delivered at one time according to disease, location and sizes.

  • PDF

A Case of Rapid Cycling Secondary Mania after Gamma-knife Radiosurgery (감마나이프 방사선수술 후 발생한 급속 순환성 이차성 조증 1예)

  • Chung, Chan-Ho;Chae, Jeong-Ho;Kim, Im-Ryol;Lee, Chung-Kyoon;Lee, Kyu-Hang
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.2
    • /
    • pp.302-308
    • /
    • 1996
  • A case of rapid cycling mania secondary to gamma-knife radiosurgery for the treatment of refractory epilepsy was reported. A 21-year old woman who had a gamma-knife radiosurgical operation for the treatment of refractory seizure two years ago was admitted because of manic episodes. Although seizure was relieved, manic symptoms like decreased need for sleep, elated mood, unprovoked laughing, grandiose delusion and bizarre behaviors were developed 11 months after the operation. These symptoms recurred lour rimes for eight months. There were no past personal and family history of mood disorders. Laboratory examinations including electroencephalogram ana endocrinological study did not show any abnormal findings. The rapid cycling secondary manic was relieved by lithium. She was then discharged after 5 months. Mood change was not significant during follow-up while hypomania emerged by dose reduction. The secondary mania seemed to be caused or triggered by the right temporal lobe damage induced by gamma-knife radiosurgery.

  • PDF

Determination of Output Factors for the Gamma Knife using a Radiophotoluminescent Glass Rod Detector (유리선량계를 이용한 감마나이프의 출력인자 결정)

  • Rah, Jeong-Eun;Suh, Won-Seop;Shin, Dong-Oh;Kim, Hee-Sun;Suh, Tea-Suk
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.13-19
    • /
    • 2007
  • The purpose of study Is to Investigate whether glass rod detector (GRD) would be suitable for dosimeter of radiotherapy units. A GRD Is used for the measurement of the ou4put factors and x-axis beam profiles from Gamma Knife. The output factors measured with GRD from the 14, 8 and 4mm collimators relative to the 18mm collimator are $0.980{\pm}0.013,\;0.949{\pm}0.013\;and\;0.872{\pm}0.012$, respectively. The output factors obtained with a GRD are within 1.0% In good agreement with the values recommended by the manufacture. The full width at half maximum (FWHM) of x-axis beam profiles measured with GRD are 5.9mm at a 4mm collimator.

  • PDF

Clinical Analysis of Inverse Planning for Radiosurgery ; Gamma Knife Treatment Plan Study (방사선 수술 역방향 치료계획 유용성 평가)

  • Jin, Seong Jin;Je, Jae Yong;Park, Cheol Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.343-348
    • /
    • 2015
  • The purpose of this study is a comparison of forward planning(FP) and inverse planning(IP) of a radiosurgery procedure. 10 patients of acoustic schwannoma MR image were used for treatment plan. FP-1,2 and IP were established under the same condition. FP and IP were compared by number of shot, conformity index(CI), paddic conformity index(PCI), gradiant index(GI) and treatment time. On average the treatment plan produced by IP tool provided an improved or similar CI, PCI, GI and reduced treatment time as compared to the FP (CI;FP-1:0.85, FP-2:0.86, IP:0.94, PCI;FP-1:0.79, FP-2:0.81, IP:0.78, GI;FP-1:2.94, FP-2:2.94, IP:3.01). The inverse planning system provides a clinically useful plan while reducing the planning time and treatment time.

Analysis of Fractional Anisotropy Measurements of Diffusion Tensor Images in the Gyrus of the Brain by AUDIT-K Scale (AUDIT-K 척도에 따른 뇌 이랑 부위의 확산텐서 비등방도 측정값 분석)

  • Kwak, Jong-Hyeok;Kim, Gyeong-Rip;Cho, Hee-Jung;Lee, Eun-Sook;Sung, Soon-Ki
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.7
    • /
    • pp.176-185
    • /
    • 2019
  • Diffusion tensor images were obtained for middle-aged men according to the AUDIT-K scale. As a result of the fractional anisotropy (FA) value of the gyrus nerve fibers in the brain region measured and analyzed by the Tract-Based Spatial Statics, FA values of general drinkers were measured lower than those of estimated alcohol use disabled people. This was statistically significant. In other words, the use of alcohol significantly affects the anatomic microstructural changes measured in the Gyrus of the brain region, and it may damage the nerve fiber tract and affect the functional abnormalities associated with it.

The Alignment Evaluation for Patient Positioning System(PPS) of Gamma Knife PerfexionTM (감마나이프 퍼펙션의 자동환자이송장치에 대한 정렬됨 평가)

  • Jin, Seong Jin;Kim, Gyeong Rip;Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.203-209
    • /
    • 2020
  • The purpose of this study is to assess the mechanical stability and alignment of the patient positioning system (PPS) of Leksell Gamma Knife Perfexion(LGK PFX). The alignment of the PPS of the LGK PFX was evaluated through measurements of the deviation of the coincidence of the Radiological Focus Point(RFP) and the PPS Calibration Center Point(CCP) applying different weights on the couch(0, 50, 60, 70, 80, and 90 kg). In measurements, a service diode test tool with three diode detectors being used biannually at the time of the routine preventive maintenance was used. The test conducted with varying weights on the PPS using the service diode test tool measured the radial deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. In order to evaluate the alignment of the PPS, the radial deviations of the correspondence of the radiation focus and the LGK calibration center point of multiple beams were averaged using the calibrated service diode test tool at three university hospitals in Busan and Gyeongnam. Looking at the center diode for all collimators 4, 8, and 16 mm without weight on the PPS, and examining the short and long diodes for the 4 mm collimator, the means of the validation difference, i.e., the radial deviation for the setting of 4, 8, and 16 mm collimators for the center diode were respectively measured to 0.058 ± 0.023, 0.079 ± 0.023, and 0.097 ± 0.049 mm, and when the 4 mm collimator was applied to the center diode, the short diode, and the long diode, the average of the radial deviation was respectively 0.058 ± 0.023, 0.078 ± 0.01 and 0.070 ± 0.023 mm. The average of the radial deviations when irradiating 8 and 16 mm collimators on short and long diodes without weight are measured to 0.07 ± 0.003(8 mm sd), 0.153 ± 0.002 mm(16 mm sd) and 0.031 ± 0.014(8 mm ld), 0.175 ± 0.01 mm(16 mm ld) respectively. When various weights of 50 to 90 kg are placed on the PPS, the average of radial deviation when irradiated to the center diode for 4, 8, and 16 mm is 0.061 ± 0.041 to 0.075 ± 0.015, 0.023 ± 0.004 to 0.034 ± 0.003, and 0.158 ± 0.08 to 0.17 ± 0.043 mm, respectively. In addition, in the same situation, when the short diode for 4, 8, and 16 mm was irradiated, the averages of radial deviations were 0.063 ± 0.024 to 0.07 ± 0.017, 0.037 ± 0.006 to 0.059 ± 0.001, and 0.154 ± 0.03 to 0.165 ± 0.07 mm, respectively. In addition, when irradiated on long diode for 4, 8, and 16 mm, the averages of radial deviations were measured to be 0.102 ± 0.029 to 0.124 ± 0.036, 0.035 ± 0.004 to 0.054 ± 0.02, and 0.183 ± 0.092 to 0.202 ± 0.012 mm, respectively. It was confirmed that all the verification results performed were in accordance with the manufacturer's allowable deviation criteria. It was found that weight dependence was negligible as a result of measuring the alignment according to various weights placed on the PPS that mimics the actual treatment environment. In particular, no further adjustment or recalibration of the PPS was required during the verification. It has been confirmed that the verification test of the PPS according to various weights is suitable for normal Quality Assurance of LGK PFX.

Failure Pattern of Pineal and Ectopic Pineal Germ Cell Tumor after Gamma Knife Radiosurgery (송과선 및 이소성 송과선 생식세포종의 감마 나이프 수술 후 재발 양상)

  • Cho, Heung-Lae;Sohn, Seung-Chang
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.92-100
    • /
    • 2000
  • Purpose :This study was performed to determine the optimal treatment velum of Patients treating with radiation therapy for intracranial germ cell tumor. Materials and Methods : From 1993 to 1998, 19 patients with intracranial germ cell tumors treated by gamma knife radiosurgery were analyzed. The location of tumor was as follows; 9 cases on pineal region, 1 case on suprasellar region, and 9 cases of multiple lesion. 7 patients were pathologically verified; 5 cases of germ cell tumor and 2 cases of non germinomatous germ cell tumor. Tumor volume was ranged from 2.4 cm$^{3}$ to 74 cm$^{3}$. Irradiation dose was 10 Gy to 20 Gy with 50% isodose curve. Follow up period was 10 months to 54 months. Results : Recurrences were observed in 14 cases among 19 (74%) patients. Complete remission and partial remission were achieved in 2 (11%) and 10 (53%) respectively. No response was observed in 7 (36%). 2 cases were recurred within original tumor bed. 6 cases were recurred beyond but contiguous with tumor bed. Ventricular relapses separated from pretreatment tumor bed were 3. Spinal recurrences were 4. Among 8 recurred cases of which tumor volume is smaller than 20 cm$^{3}$, 2 were recurred within original tumor bed, 4 were recurred beyond but contiguous with tumor bed, and 1 spinal recurrence. Meanwhile, 6 cases of which tumor volume larger than 20 cm3, 1 case was recurred beyond but contiguous with tumorbed, 2 ventricular recurrences separated with original tumor bed, and 3 spinal recurrences. 5 cases which did not show any recurrence sign showed characteristics of single lesion, tumor volume smaller than 20 cm$^{3}$ and normal tumor marker. All of 4 cases of spinal recurrences happened in the case having ventricular invasion or lesion. Among 9 cases having multiple lesion, only 3 cases recurred within original tumor bed or around tumor bed, the other 6 cases recurred separated from pretreatment tumor bed. Conclusion : Gamma knife radiosurgery is not recommended for the treatment of intracranial germ cell tumor. It is because of small treatment volume and inadequate radiation dose that are characteristics of gamma knife radiosurgery. Tumor volume, ventricular invasion or ventricular lesion in multiple lesion are important factors to be considered for the wide field radiation therapy Tumor volume smaller than 20 cm$^{3}$, single lesion, no ventricular lesion or invasion, and normal tumor marker are ideal indications for small involved field radiation therapy. Prophylactic spinal irradiation seems to be necessary when there is ventricular lesion, ventricular invasion, and multiple lesions. When the tumor volume is larger than 20 cm$^{3}$, multiple lesions, abnormal tumor marker, and whole ventricular irradiation or partial brain irradiation would be possible and neoadjuvant chemotherapy would be most beneficial in these group.

  • PDF

Analyses of the indispensible Indices in Evaluating Gamma Knife Radiosurgery Treatment Plans (감마나이프 방사선수술 치료계획의 평가에 필수불가결한 지표들의 분석)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.303-312
    • /
    • 2017
  • The central goal of Gamma Knife radiosurgery(GKRS) is to maximize the conformity of the prescription isodose surface, and to minimize the radiation effect of the normal tissue surrounding the target volume. There are the various kinds of indices related with the quality of treatment plans such as conformity index, coverage, selectivity, beam-on time, gradient index(GI), and conformity/gradient index(CGI). As the best treatment plan evaluation tool, we must check by all means conformity index, GI, and CGI among them. Specially, GI and CGI related with complication of healthy normal tissue is more indispensible than conformity index. Then author calculated and statistically analysed CGI, the newly defined conformity/gradient index as well as GI being applied widely using the treatment planning system Leksell GammaPlan(LGP) and the verification method Variable Ellipsoid Modeling Technique(VEMT). In the study 10 patients with intracranial lesion treated by GKRS were included. Author computed the indices from LGP and VEMT requiring only four parameters: the prescribed isodose volume, the volume with dose > 30%, the target volume, and the volume of half the prescription isodose. All data were analyzed by paired t-test, which is statistical method used to compare two different measurement techniques. No statistical significance in GI at 10 cases was observed between LGP and VEMT. Differences in GI ranged from -0.14 to 0.01. The newly defined gradient index calculated by two methods LGP and VEMT was not statistically significant either. Author did not find out the statistical difference for the prescribed isodose volume between LGP and VEMT. CGI as the evaluation index for determining the best treatment plan is not significant statistically also. Differences in CGI ranged from -4 to 3. Similarly newly defined Conformity/Gradient index for GKRS was also estimated as the metric for the evaluation of the treatment plans through statistical analysis. Statistical analyses demonstrated that VEMT was in excellent agreement with LGP when considering GI, new gradient index, CGI, and new CGI for evaluating the best plans of GKRS. Due to the application of the fast and easy evaluation tool through LGP and VEMT author hopes CGI and newly defined CGI as well as gradient indices will be widely used.

Methodologic Aspect of LINAC-based Stereotactic Radiosurgery (선형가속기 기반 뇌정위 방사선 수술기법)

  • Choi, Tae Jin
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.127-137
    • /
    • 2012
  • A conversing beam is firstly designed for radiosurgery by a neurosugern Lars Leksell in 1949 with orthogonal x-rays tube moving through horizontal moving arc to focusing the beam at target center. After 2 decades he composits 201 source of the Co-60 for gamma knife which beams focused at locus. Sveral linac-based stereotactic radiosurgery using the circular collimated beam which size range for 0.4~4.0 cm in a diameter by non-coplanar multiarc have been developed over the decades. The irregular lesions can be treated by superimposing with several spherical shots of radiation over the tumour volume. Linac based techniques include the use of between 4 and 11 non-co-planar arcs and a dynamic rotation technique and use photon beam energies in the range of 6~10 MV. Reviews of the characteristics of several treatment techniques can be found in the literature (Podgorsak 1989, Schell 1991). More in recent, static conformal beams defined by custom shaped collimators or a mini- or micro-multileaf collimator (mMLC) have been used in SRS. Finally, in the last few years, intensity-modulated mMLC SRS has also been introduced. Today, many commercial and in-house SRS programs have also introduced non-invasive immobilization systems include the cyberknife and tomotherapy and proton beam. This document will be compared the characteristics of dose distribution of radiosurgery as introduced gamma knife, BrainLab include photon knife in-house SRS program and cyberknife in currently wide used for a cranial SRS.