Model Test of Stabilizing Measures for Ground Failure Due to Soft Ground Excavation (연약지반 굴착에 따른 지반파괴 억지대책 실내모형 실험)

  • Kim, Jae-Hong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.907-917
    • /
    • 2014
  • When conducting excavations after burying the soft ground, even if the retaining walls are installed, failure often occurs within backfill. In order to minimize the occurrences of failures, model test was performed after the installation of stabilizing piles to investigate the stabilizing effects. The model chamber is set up with clay foundation reinforced with and without stabilizing piles. During the excavation of clay foundation, the subsidence, pore water pressure, and soil pressure along the excavation were measured. As a result of the model test, the increase of excavation levels and the reduction of subsidence of back ground were observed with the stabilizing piles, compared to those without the stabilizing piles. The installation of stabilizing piles does not influence the pore water pressure change, but induces less subsidence rate. In addition, the depth of excavation has a significant effect on the back ground and it was evaluated that the maximum subsidence occurs as it is closer to the excavation point.

A Test for Characterization on Landslides Triggering and Flow Features of Debris using a Flume test Equipment (모형실험 장치를 이용한 산사태 발생 및 사태물질 거동특성 실험)

  • Chae Byung-Gon;Song Young-Suk;Seo Yong-Seok;Cho Yong-Chan;Kim Won-Young
    • The Journal of Engineering Geology
    • /
    • v.16 no.3 s.49
    • /
    • pp.275-282
    • /
    • 2006
  • This study was conducted laboratory flume tests to identify landslide features and flow characteristics of debris using a flume test equipment. Under the several test conditions dependent on rainfall intensity and slope angle, the authors measured pore water pressure, slope failure and displacement, spreading area of debris on a regular time interval. The test processes were also recorded by video cameras and digital still cameras. According to the test results, pore water pressures have trends of direct proportion to the rainfall intensity and the slope angle, resulting in high potential of landslide triggering. The spreading area of debris is also increased with the slope angle and the rainfall intensity as well as the rainfall duration.

Assessment on Consolidation Material Function and Initial Stress for Soft Ground by Hydraulic Fill the at Southern Coast of Korea (남해안 준설매립 연약지반에 대한 압밀 물질함수 및 초기응력 산정)

  • Jeon, Je Sung;Koo, Ja Kap
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.4
    • /
    • pp.136-145
    • /
    • 2011
  • For a massive project related to building national industrial complexes on a soft ground applied to PVD after dredging and hydraulic fill, laboratory tests were carried out using undisturbed sample taken from various depth. Piezocone penetration and dissipation tests were carried out to assess horizontal coefficient of consolidation and initial stress in field. The ground consists of upper dredged fill and lower original clay layer having both similar marine clays. It should be, however, considered as multi-layered soft ground having different initial void ratio, initial water content, initial effective stress, and permeability and compressibility with directions. To assess initial stress of those soft layers in which have different stress history related to consolidation, CPTu test results, especially excess pore water pressure, were analyzed. It allows to find out distribution of excess pore water pressure and initial stress inner original clay layer.

Physical Model Experiment on the Seepage Characteristics through a Dam by using FDR Sensor (FDR 센서를 활용한 제체 누수특성의 실내 모형 실험 연구)

  • Kim, Gyoo-Bum;Im, Eunsang;Ryu, Ho-Cheol;Hwang, Chan-ik;Kim, Hyeong-Jong
    • The Journal of Engineering Geology
    • /
    • v.28 no.4
    • /
    • pp.715-726
    • /
    • 2018
  • Various methods, such as geophysical exploration, temperature measurement, and fiber optics, have been developed for detecting the seepage at a dam. In this study, in order to investigate the possibility of leakage detection using dielectric constant of FDR sensor, a physical model consisting of weak and no-weak zones is fabricated and the sensors for dielectric constant, temperature and pore water pressure measurements are installed. As a leakage happens, the dielectric constant changes more rapidly through a weak zone than no-weak zone. In addition, comparing three factors (dielectric constant, temperature, and pore water pressure), the response of dielectric constant to seepage is fast and it is easily recognized even at the end measurement point. Considering these features, it is concluded that it could be possible to cope with the leakage detection quickly and efficiently if the dielectric constant is measured at the downstream slope of a dam.

Improvement of In-Situ Stress Measurements by Hydraulic Fracturing - Focusing on the New Standard by Japanese Geotechnical Society (수압파쇄를 이용한 초기응력 측정 결과의 신뢰도 제고 방안 - 일본 지반공학회 표준시험법 개정안을 중심으로)

  • Kim, Hyung-Mok;Lee, Hangbok;Park, Chan;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.32 no.1
    • /
    • pp.1-19
    • /
    • 2022
  • In this report, new standard, published by Japanese Geotechnical Society, on in-situ stress measurements by hydraulic fracturing was reviewed. In the standard, modification was made for the calculation of fracture re-opening pressure in consideration of fracture surface roughness and residual aperture. The standard also presents how much the system compliance influences the estimation of the fracture re-opening pressure and subsequent in-situ stresses. It is shown that the stiffer the rock mass is, the system compliance should be sufficiently small enough so as to obtain in-situ stress measurement with higher confidence.

Evaluation of Seismic Displacements of Quay Walls Using Newmark Sliding Block Method (Newmark 변위법을 이용한 중력식 안벽의 지진변위 산정)

  • 김성렬;장인성;정충기;김명모
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.8
    • /
    • pp.123-133
    • /
    • 2004
  • The magnitudes of wall thrust acting on quay walls can easily vary due to the development of excess pore pressure in backfill. In this research, a new displacement model was proposed to predict the displacement of the wall considering such magnitude variations of the wall thrust. This model is based on Newmark sliding block concept. The magnitude variation of the wall thrust is modelled by varying the magnitude of yield acceleration. The parametric study was performed to analyze the effects of input parameters on the seismic displacement of the wall, and the validity of this model was verified by comparing its predicted displacements with those of Is shaking table tests.

Evaluation of the Seismic Stability of Fill Dam by Shaking Table Tests (진동대 시험을 통한 Fill Dam의 내진 안정성 평가)

  • Yoon, Won-Sub;Chae, Young-Su;Park, Myeon-Gu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.4
    • /
    • pp.81-92
    • /
    • 2011
  • In order to understand evaluation of the seismic stability of a fill dam, we made chambers of 1:100, 1:70, and 1:50 (the ratio of the miniature), considering the law of similarity based on drawings of three representative cross sections. And we measured an increase in acceleration, excess pore water pressure, and vertical/horizontal displacement after applying Hachinohe wave (long period), Ofunato wave (short period), and artificial wave, complying with the domestic standards, in order to evaluate the stability and interaction between the ground, the structure, and fluids based on the measurements. As a result, we could observe that displacement of the target cross section was relatively small compared to the allowed level of 30 cm, ensuring proper stability for an earthquake. Regarding the acceleration measurements, the increase rate was 20% for Hachinohe wave and Ofunato wave but 30% for the artificial wave. With respect to the excess pore water pressure, it was lower than 1 (which is the permissible ratio for liquefaction) ensuring proper stability as well.

A Study on Piezocone Test using a Calibration Chamber (Calibration Chamber를 이용한 피에조콘 시험에 관한 실험연구)

  • Kim, Dae-Kyu;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.3
    • /
    • pp.99-106
    • /
    • 2000
  • 피에조콘 관입 및 소산 시험이 Calibration Chamber 및 미니 피에조콘을 이용하여 수행되었다. 시험은 정규압밀 및 과압밀 점토에 대하여 정지토압 상태에서 실시되었으며 UI (filter element at cone tip), U2 (filter element above cone base) 두 종류의 피에조콘이 사용되었고 0.3cm/sec, 0.6cm/sec의 관입속도가 적용되었다. 오실로스코프를 사용하여 소산시험 초기 간극수압의 급격한 변화를 측정하였다. 시험결과로부터 관입속도, filter element 위치, 과압밀비가 피에조콘 관입 및 소산시험의 결과에 미치는 영향을 고찰하였으며 입도분포시험을 실시하여 관입시험 전후의 입도분포 치이를 고찰하였다.

  • PDF

Slope Instability Due to Rainfall (강우로 인한 사면 불안정)

  • 김상규;김영묵
    • Geotechnical Engineering
    • /
    • v.7 no.1
    • /
    • pp.53-68
    • /
    • 1991
  • This paper aims at the investigation of various seepage behavior when rainfall infiltarates into unsaturated ground and understanding of the mechanism for slope instability due to rainfall. For this purpose an experimental study is carried out for model slopes using the test equipment which can simulate various rainfall intensity. In addition, a numerical study is performed for the same dimension and boundary condition as the experimental model. From both the experimental test and numerical analysis the progress of wetting front with time, critical amounts of rainfall, and pore-water pressure development with time are know in detail and their effects on slope stability are described.

  • PDF

Nonlinear Consolidation Analysis Considering Radial Drainage (수평배수를 고려한 비선형 압밀해석)

  • Lee, Song;Chae, Young-Su;Hwang, Koou-Ho;Jeon, Je-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.6
    • /
    • pp.105-115
    • /
    • 2000
  • 본 연구는 현실에 부합하는 연약지반의 압밀거동을 예측하기 위한 연구로서, 일단 3차원 배수 조건하에서 지반의 자중 및 압축성과 투수성의 비선형적 성질이 고려된 비선형 압밀모델을 구성하였다. 또한 연직 배수재의 시공과정에서 발생할수 있는 지반의 교란현상 및 다양한 이질층의 구성, 점증적인 하중재하 조건, 연직배수재의 부분관입 조건에 대한 고려가 가능하도록 비선형 압밀모델을 수정, 보완하였다. 이상의 연구결과를 바탕으로 유한차분방법에 의한 수치해석을 실시하였고 최종적으로 각종 희귀분석과정을 도입한 3차원 비선형 압밀해석 프로그램을 개발하였다. Ska-Edeby의 시험시공 사례를 통한 개발 프로그램의 검증을 실시하였는데, 시험시공 사례의 경우, 현장에서 측정한 깊이별 침하량 및 간극수압 결과를 개발 프로그램에 의한 예측결과와 비교, 분석하였다. 또한 개발 프로그램을 이용하여 다층지반 해석과 관련된 기존 해석방법의 문제점 및 지반의 교란효과와 연직배수재의 부분관입조건, 점증적인 하중재하 조건등이 지반의 압밀거동에 미치는 영향에 대해 살펴보았다.

  • PDF