• 제목/요약/키워드: 가열 성능

검색결과 398건 처리시간 0.03초

복합형 태양열 가열기에서 열매체 단일운전에 따른 기기성능 평가 (Performance Estimation of Hybrid Solar Air-Water Heater on Single Working of Heating Medium)

  • 최휘웅;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.49-56
    • /
    • 2014
  • Research about hybrid solar air-water heater that can make heated air and hot water was conducted as a part of improving efficiency of solar thermal energy. At this experiment, ability of making heating air and hot water was investigated and compared with traditional solar air heater and flat plate solar collector for hot water when air or liquid was heated respectively. Comparing hybrid solar air-water heater that used in this experiment to other solar air heater studied already, it has a lower efficiency at same mass flow rate. Air channel structure, fin's shape and arrangement in the air channel result in these difference then the ability of air heating need to be improved with changing these thing. In case of making hot water, performance was shown as similar with traditional system although the air channels were established beneath absorbing plate. But the heat loss coefficient was shown higher value by installing of air channel. Also the performance of hot water making was shown lower value at same liquid mass flow rate with traditional flat plate solar collector for hot water. So the necessity of performance improvement at lower mass flow rate of each heating medium can be confirmed.

열복사를 적용한 드럼 건조기의 건조 메커니즘 분석 및 성능 예측에 관한 연구 (Numerical Investigation of the Effect of IR Heating on Drying Mechanism in a Tumble Dryer)

  • 최철진;장정현;김종민;김만영
    • 대한기계학회논문집B
    • /
    • 제34권3호
    • /
    • pp.219-228
    • /
    • 2010
  • 텀블형 드럼 건조기의 적외선 건조 과정동안의 온도 및 수분량의 변화를 예측할 수 있는 2 차원 수학적 모델을 개발하였다. 본 모델에서는 건조대상 물질의 액체 수분의 이동과 건조공기의 유동 및 열전달을 고려하였다. 유체의 유동과 열전달 현상, 그리고 복사열전달은 유한체적법을 이용하여 해석하였다. 텀블 건조기의 2 차원 모델을 모사하기 위한 지배방정식을 소개한 후 적외선 히터, 히터의 온도, 그리고 가열 패턴에 따른 수치해석을 수행하였고, 적외선 히터를 도입함으로써 건조시간을 감소시킬 수 있음을 제시하였다.

표준화재에 노출된 방염처리 목재의 내부온도에 관한 연구 (Study on the Internal Temperature of Flame Resistant Treated Wood Exposed to a Standard Fire)

  • 김황진
    • 한국화재소방학회논문지
    • /
    • 제32권3호
    • /
    • pp.14-18
    • /
    • 2018
  • 건축 재료로 사용되는 목재의 내화성능에 관한 기존 연구들은 목재에 난연 또는 방염 처리하였을 경우 연소특성을 확인하는 것에 집중되어 졌다. 본 논문에서는 화염에 노출된 목재의 열분해와 밀접한 관련이 있는 내부 온도 변화를 확인하기 위하여 건축용 구조재로 널리 사용되는 미송(Douglas-fir)에 방염액 및 방염도료를 처리 후 표준 가열 온도 곡선에 따라 수평가열로에서 가열실험을 실시하였다. 실험결과 방염액을 처리하였을 때 목재내부의 열확산이 현저히 감소하는 것을 확인할 수 있었으며 방염도료를 처리한 시료의 경우 고온에 노출 되었을 때 도막이 박리되어 방염효과를 기대할 수 없었다. 따라서 두꺼운 목재에 방염효과를 높이기 위해서는 목재표면에 도막을 형성시키는 방염도료보다는 목재내부로 침투하는 방염액을 사용하는 것이 방화효과가 클 것으로 판단된다.

선탄경석(選炭硬石)과 광산화물(鑛酸化物)로 제조(製造)한 담체(擔體)의 중금속(重金屬) 불용화(不溶化) 특성연구(特性硏究) (A study of Immobilizing Heavy metals by pellets manufactured from Coal tailings and Iron oxide)

  • 이계승;송영준
    • 자원리싸이클링
    • /
    • 제21권1호
    • /
    • pp.75-81
    • /
    • 2012
  • 선탄경석을 환경개선물질로 순환자원화하기 위해 철산화물과 혼합하여 중금속 불용화제를 제조하고 이의 적정제조 조건과 중금속에 대한 불용화 성능을 평가하였다 선탄경석을 분쇄한 후 철산화물의 분말을 혼합하여 구형의 펠릿을 제조하고 이를 가열하여 중금속 불용화제를 제조하였다. 온도별로 가열한 결과, $1100^{\circ}C$부터 선탄경석에 함유된 탄질분에 의해 영가철이 생성되었다. 제조된 불용화제는 구형의 다공체로서 공극률은 34.63%, 겉보기 밀도는 1.31 g/mL, 공극의 평균크기는 9.82 ${\mu}m$로 측정되었다. 불용화제를 비소(V), 구리(II), 크롬(VI), 카드뮴(II)이 함유된 각각의 중금속 용액과 반응시킨 결과, 영가철이 생성된 $1100^{\circ}C$에서 제조된 펠릿이 중금속 불용화도가 높고 pH를 더 높이는 것으로 나타났다. 중금속농도 10 ppm의 용액을 99.9%이상 불용화하기까지 비소의 경우 1시간, 크롬의 경우 2시간, 구리의 경우 4시간이 필요하였다. 그러나 카드뮴의 경우 불용화도가 낮게 나타났고 중금속농도가 높을수록 불용화도가 더 낮아지는 것으로 나타났다.

자기핵융합과 KSTAR

  • 권면
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.1-1
    • /
    • 2010
  • 핵융합에너지는 1930년대 한스 베테에 의해 태양과 별 에너지의 근원임이 밝혀진 후 소핵 폭탄실험 성공으로 그 위력적인 에너지를 인공적으로 만들 수 있음을 세상에 드러내게 된다. 그 뒤 이 에너지의 평화적인 이용 노력이 시작되었고 1958년 스위스에서 핵융합에너지의 평화적 이용에 대한 첫 국제회의가 열리게 되면서 에너지원으로서의 연구를 통해 냉전시대의 경쟁 대상의 과학기술의 하나로 부각되면서 눈부신 성능 향상을 보여주게 되었다. 아직 여러 어려운 관문이 남아있지만 기후변화와 에너지원 고갈에 의한 새로운 에너지원에 대한 강력한 필요성이 제기되면서 ITER와 같은 대형 국제공동연구시설 건설이 시작되었고 2030년대에는 최초의 핵융합발전소를 건설하려는 꿈도 그려가고 있다. 핵융합에너지를 얻는 방식에는 여러 방법이 시도되었는데 현재는 자기장을 이용해 플라즈마를 핵융합반응이 일어나기에 충분한 시간동안 가두는 자기핵융합방식과 관성으로 플라즈마를 가두는 관성핵융합방식으로 크게 구분할 수 있다. 자기핵융합방식의 경우 플라즈마를 만들고 가열하여 핵융합반응 확률이 높은 고온으로 가열하고 그 조건을 오래 지속시키는 기술들이 필요한데 이 기술들은 오늘날의 거의 모든 극한기술들이 망라되어 적용되는데 초전도, 고주파/ 초고주파, 대전력 공급, 대형 시설 실시간 제어기술, 대규모 신호처리기술, 고온 플라즈마 진단 기술, 대규모 시스템 시뮬레이션 기술 등이 그것이다. 여기에 또한 중요한 기술의 하나로 초고진공 기술이 필요하다. 이러한 기술이 집약되고 서로 통합되어 하나의 목적을 위해 쓰여지도록 고안되고 만들어진 장치가 자기핵융합 장치이며 따라서 현대의 자기핵융합장치들은 굉장히 복잡하며 대형 시설로 지어질 수밖에 없다. 우리나라는 1970년대 말부터 소형의 플라즈마 연구시설을 시작으로 자기핵융합 연구를 시작하면서 인력 양성을 시작하였으며 가속기 등 대형 연구시설이 본격적으로 지어지던 1990년대에 세계적으로 유래가 없는 초전도 자기핵융합장치인 KSTAR장치 건설 프로젝트를 시작하게 되었다. 총 11년이 넘는 건설기간 동안 여러 학교와 연구기관, 그리고 산업체가 참여하여 성공적으로 시운전을 실시하였으며 당당히 세계적인 장치를 통한 핵융합연구 대열에 동참하게 되었다. 이를 통한 기술 개발의 결과로 국제적 공동연구장치 ITER의 건설사업에 참여하게 되었고 KSTAR와 ITER를 통해 핵융합 에너지 상용화 기술 개발을 국가적인 기술개발의 목표로 결정하고 연구개발계획을 전략적으로 세워 진행하고 있다. 이번 논문에서는 자기핵융합의 특징과 연구 동향을 통해 우리나라의 기술 수준을 조망하고 특히 진공 기술 분야와의 상호 의존적 영향 분석을 통해 공동의 발전 방향을 모색해 보려고 한다.

  • PDF

구동장치 및 열교환기 변경에 따른 냉매가열식 열펌프의 성능특성 (Performance of a Refrigerant Heating Type Heat Pump by Changing of Driving Devices and Heat Exchangers)

  • 박윤철;김상혁;김지영
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.49-56
    • /
    • 2008
  • When the outdoor air temperature decreased less than the freezing temperature, frost forms at the surface of heat exchangers and it makes the performance degradation of a heat pump system. In this study, a heat pump system has been developed which has a refrigerant heating device as an auxiliarly heating equipment. To reduce power consumptions of the system, a liquid pump, rather than a compressor, was used to drive refrigerant in the heat pump cycle. Ratio of refrigerant mass flow between a refrigerant heating heat exchanger(GHX) and a outdoor plate heat exchanger(PHX) was varied and the system performance was measured and analyzed. As results, when the refrigerant flow rate to the GHX was decreased, the system performance is decreased due to heat absorption capability restriction of the GHX and small variation of the power consumption in the compressor. The effect on the evaporating and condensing pressure by the distribution ratio of the refrigerant to the each heat exchanger is small compare to the effect by the frequency change in the compressor. When the compressor was replaced by the liquid pump, the capacity of the system decreased a little, however the power consumption decrease approximately 80% compare with the power used in the compressor.

복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구 (A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater)

  • 최휘웅;파쿠르 로커만;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.

복합형 태양열 가열기 열매체 동시운전시의 열적 성능에 관한 실험적 연구 (Experimental Study for Thermal Performance of Hybrid Air-Water Heater Using Solar Energy during Heating Medium Working Simultaneously)

  • 최광환;윤정인;손창효;최휘웅;김부안
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.115-121
    • /
    • 2014
  • With increment on interesting about improving renewable energy efficiency, many research have been conducted and the research about hybrid air-water heater using solar energy that can make heating air and hot water has been conducted also. In this experiment, the temperature difference and thermal efficiency were investigated when two heating medium(air and liquid) was working simultaneously. As a result, thermal efficiency showed 44% to 88% when these heating medium was working simultaneously depending on operation condition and it is better than traditional solar collector. Also possibility of application into building equipment also was confirmed based on temperature and thermal efficiency. But necessity of additional studies about proper operation condition according to purpose of use and heat load was confirmed because change of thermal efficiency by air velocity and flux of liquid was shown a huge difference.

플라즈마 공정 모니터링용 사중극자 질량 분석기의 필라멘트 파손분석

  • 하성용;김동훈;주정훈
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.93.2-93.2
    • /
    • 2015
  • 플라즈마를 포함한 반응성 가스 공정 분석용 사중극자 질량분석기의 필라멘트의 파손양상을 조사하였다. 또한 유전체 증착층이 이온원 성능에 미치는 영향을 분석하기 위하여 이온원의 일반적인 가동 전압 조건에서 Poisson방정식을 이용하여 전위를 수치 해석으로 구하였다. 사용중 파손된 필라멘트의 파단면을 주사전자현미경으로 관찰결과, 수직으로 절단되는 양상과 직경이 점차 작아지면서 erosion되는 두가지 양상을 보였다. 또한 파단면은 표면균열과 패시팅(faceting) 현상을 보였다. 필라멘트 사용시 가장 큰 문제는 패시팅(faceting)이다. 대부분의 결정에서는 다른 결정면보다 에너지 준위가 낮은 결정면이 존재한다. W 원자는 고온에서 확산 또는 증발하여 표면에서 다시 응축할 때 표면 에너지를 최소화하기 위한 독특한 평형 형상이 만들어 지는데 이것이 패시팅의 구동력이다. 이때 국부적으로 단면적이 감소하는 곳이 생기는데, 이 지점이 집중적으로 가열되고 증발이 가속화하여 파손된다. 파단면을 EDS 분석결과, 산화물을 포함한 F, Fe 및 C이 검출되었다. 이 F과 C는 공정중 사용된 CF4의 분해에 의한 것으로 생각되며, 파손된 필라멘트를 Ar 유도결합 플라즈마로 처리한 결과 이 F, Fe 및 C의 양이 감소하였다.

  • PDF

물 직접접촉식 공기조화장치의 성능해석 (Performance Analysis of Water Direct Contact Air Conditioning System)

  • 유성연;권화길;송준;김광영;박준택
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.158-163
    • /
    • 2001
  • Performance of the water direct contact air conditioning system, in which heat and mass are transferred directly between air and water droplet, is simulated by semi-empirical method. This system improves transport efficiency compared to conventional indirect contact system and cooling, heating, dehumidification and humidification are attained with one unit. In this study, temperature and flowrate for air and water are measured in the various cooling and heating conditions, and correlations for $h_{c}A/c_{pm}$ are derived from these data. Cooling and heating characteristics of the water direct contact air conditioning system are investigated using correlations.

  • PDF