• Title/Summary/Keyword: 가압 시스템

Search Result 313, Processing Time 0.028 seconds

An Experimental Study of Laser-induced Ignition of Solid Propellant with Strand Burner (레이저 점화에 의한 고체추진제 Strand Burner 실험)

  • Lee, Sanghyup;Ko, Taeho;Yang, Heesung;Yoon, Woongsup
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.2
    • /
    • pp.39-45
    • /
    • 2013
  • Basically, in order to apply solid propellant as ignition source to high energy metal particle combustion system, we analyzed combustion characteristics of the HTPB/AP/Al, HTPE/AP/Al propellants by using a strand burner. The propellants were tested in a high-pressure windowed strand burner, which was pressurized up to 300 psia with pure argon gas. Strand burner was visualized with two quartz windows and ignition was accomplished by a 10 W $CO_2$ laser. The burning rate of propellant was measured with high-speed camera method for frame analysis and photodiode method for combustion time analysis. Emission spectrum was measured with spectrometer at 300 nm ~ 800 nm and 1500 nm ~ 5000 nm and then we analyzed species during propellant combustion.

Hybrid Rocket Thrust Control in an Environment With Decreasing Oxidizer Supply Pressure (산화제 공급압력이 감소하는 환경에서 하이브리드 로켓 추력제어)

  • Chae, Donghoon;Chae, Heesang;Lee, Changjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.5
    • /
    • pp.325-332
    • /
    • 2022
  • The vertical take-off and vertical landing (VTVL) function is essential to carry out exploration missions on the moon or Mars. For this, the engine of the exploration vehicle must have appropriate thrust control accuracy and response time. The hybrid rocket engine (HRE) is known to have a high level of thrust control capability that can satisfy these conditions. This study aims to first verify whether the thrust control performance of the developed HRE is suitable for VTVL. To this end, an oxidizer supply system that does not use a pressurization device was adopted, aiming for a mission time of about 10 seconds. In this study, the thrust control characteristics appearing under various supply pressure decreasing conditions were identified through experiments. Appropriate tank and charging conditions were set from the experimental results. In addition, the results of previous studies and current study's test were compared to confirm whether the developed HRE had adequate control performance for VTVL, and finally, the thrust control performance was verified through altitude control simulation.

Influence of Taper Angle on Axial Behavior of Tapered Piles in Sand (모래지반에서 테이퍼 각도가 테이퍼말뚝의 연직거동에 미치는 영향)

  • Paik, Kyu-Ho;Lee, Jun-Hwan;Kim, Dae-Hong
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.8
    • /
    • pp.69-76
    • /
    • 2007
  • Axial behavior of tapered piles is affected by taper angle, stress state of soils, soil frictional angle and pile-soil interface friction angle. In this paper, a series of model pile load tests were performed using a calibration chamber in order to investigate the effect of taper angle on the axial response of cast-in-place tapered piles in sand. According to results of the tests, as taper angle of piles increased, the shaft load capacity of piles increased but its base load capacity decreased. The unit base load capacity of piles increased with increasing taper angle for medium sand but decreased for dense sand. The ratio of shaft to total load capacity increased with increasing taper angle and with decreasing relative density of soils. The test results also showed that total load capacity per unit pile volume increased with increasing taper angle for medium sand, but it decreased for dense sand. Therefore, it can be stated that tapered piles are economically more beneficial for medium sand than for dense sand.

Compression Test of a TBM Thrust Jack for Validating Buckling Stability (TBM 추진잭의 좌굴 안정성 검토를 위한 압축시험)

  • Mun-Gyu Kim;Min-Gi Cho;Jung-Woo Cho;Han-Young Jeong
    • Tunnel and Underground Space
    • /
    • v.33 no.5
    • /
    • pp.339-347
    • /
    • 2023
  • As the jacks provide a thrust force on the inclined surface, bending deformations by a side force occur in the pedestal and rod parts. This can induce disorder or degradation of the thrust module, buckling stability on the inclined compression condition should be clarified to secure the reliability of shield TBM. For analyzing the stability, a buckling testing method for hydraulic cylinder was investigated and compression testing system was installed. Before the test, a numerical analysis was conducted to check the stress concentration parts. The maximum allowable force was loaded on the cylinder specimen at 0 degree surface condition as a preliminary test. After the test, plastic deformations or hydraulic leakage was not observed. The static stability of it was verified at 0 degree condition.

Development of Integrated Type Main Frame and Downhole Sonde Apparatus for Hydraulic Packer Testing in Seabed Rock under High Water Pressure (고수압 해저지반 수리특성 조사용 일체형 메인 프레임과 공내 측정장치 개발)

  • Bae, SeongHo;Kim, Jangsoon;Jeon, Seokwon;Kim, Hagsoo
    • Tunnel and Underground Space
    • /
    • v.28 no.3
    • /
    • pp.258-276
    • /
    • 2018
  • The accurate and quantitative ground information on the hydraulic conductivity characteristics of rock mass is one of the key factors for evaluation of the hydro-geological behaviour of rock mass around an excavated opening under high water pressure. For tunnel and rock structures in seabed, where the sea acts as an infinite source of water, its importance become greater with increasing construction depth below sea level. In this study, to improve the problems related with poor system configuration and incorrect data acquisition of previous hydraulic packer testing equipment, we newly developed an integrated main frame and 30 bar level waterproof downhole sonde apparatus, which were optimized for deep hydraulic packer test in seabed rock mass. Integration of individual test equipment into one frame allows safe and efficient field testing work on a narrow offshore drilling platform. For the integrated type main frame, it is possible to make precise stepwise control of downhole net injection pressure at intervals of $2.0kg_f/cm^2$ or less with dual hydraulic oil volume controller. To ensure the system performance and the operational stability of the prototype mainframe and downhole sonde apparatus, the field feasibility tests were completed in two research boreholes, and using the developed apparatus, the REV(Representative Elementary Volume) scale deep hydraulic packer tests were successfully carried out at a borehole located in the basalt region, Jeju. In this paper, the characteristics of the new testing apparatus are briefly introduced and also some results from the laboratory and in-situ performance tests are shown.

Evaluation of Lateral Load Capacity of Drilled Shafts with Pile Shape and Soil Conditions (말뚝형태 및 지반조건에 따른 현장타설말뚝의 수평지지력 평가)

  • Lee, Jun-Hwan;Paik, Kyu-Ho;Kim, Dae-Hong;Hwang, Sung-Wuk;Kim, Min-Kee
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.2
    • /
    • pp.61-69
    • /
    • 2007
  • In this study, experimental analysis was performed about lateral load capacity and behavior of laterally loaded-bored piles for soil conditions and pile shape, i.e. cylindrical and taper piles. Also, Calibration chamber load tests were performed for cylindrical and taper piles considering the variations of relative densities and restraint stresses. According to the results of chamber tests, it was found that, while both vertical and horizontal stresses affect load-responses and ultimate lateral load capacity of laterally loaded piles, effect of the horizontal stress was larger than that of the vertical stress. Effect of lateral load capacity and behavior was relatively small compared to relative density and stress state of soils surrounding piles, but showed a little difference for soil conditions. From comparison between predicted and measured lateral load capacity, it was observed that predicted results differ significantly from measured results. This is mainly due to the fact that the effect of horizontal stress is not considered in the conventional prediction methods.

Development of harmful algae collecting system for agricultural material recycling (농업재료 자원화를 위한 유해조류 포집 시스템 개발)

  • Kim, J.H.;Kim, J.M.;Jeong, Y. W.;Kwack, Y.K.;Sim, S.K.
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.50-50
    • /
    • 2022
  • 한국농어촌공사 산하의 농업용저수지 중 3786개소에 대한 수질조사를 '19년도에 실시한 결과, TOC 기준 4등급 초과 저수지 비율은 약 20%로써, 도심 근교 저수지에서 녹조현상 빈발로 인해 수질, 악취, 미관 등의 환경문제 개선 민원이 다수 발생하고 있다. 현재 녹조 발생 사후관리를 위해 주로 사용되고 있는 대형 조류제거선은 저수심 수변부에서의 적용성에 한계가 있고, Al 기반의 응집제를 사용하여 조류를 수거해서 폐기하고 있는 실정이다. (주)이엔이티는 농어촌연구원, (주)코레드, (주)삼호인넷과 함께 호소나 정체하천의 수변지역에 적용될 수 있는 저에너지형 유해조류 포집시스템 개발과, 수거된 조류부산물을 무독화하여 농업재료로 재활용하는 방안을 연구하고 있다. 저수지나 정체수역의 녹조는 바람, 수면유동 등에 의해 수변에 집적되는 특성이 있어, 인공지능 기술로 녹조현상을 감시하여 조류 밀집구간에 접근할 수 있는 자율이동식 수상이동장치를 개발 중이다. 수상이동장치는 조류포집장치를 탑재하기 위한 부력체, 원격 운전이 가능한 무인항법장치, 수변식생대 및 저수심지역 이동을 고려한 수차방식 추진체, 전체 장치의 전원 공급을 위한 고성능 배터리 등으로 구성하여 상세 도면 설계를 진행하고 있다. 조류포집장치에는 표층에 주로 분포하는 남조류를 선택 흡입하는 포집 부표를 적용하였고, Al계 응집제 사용을 배제한 분리막 실험을 통해 침지형 막분리조 및 가압형 농축조를 설계하였다. 유해조류 포집 및 농축은 수상에서 이동체에 탑재하여 이뤄지고, 육상에서는 자원 회수가 가능하도록 회분식 응집공정으로 구분하였다. 조류 밀집지역에서 수거된 조류의 무독화 및 농업재료 자원화 타당성 평가를 위해 특용 버섯균주를 활용한 시료별 분석항목을 선정하고 실험 매트릭스에 따라 실증실험을 수행하였다. 수거조류를 전처리하여 성분 및 발열량을 분석하고 버섯재배 전후의 마이크로시스틴 독소(LR, RR, LR)를 포함한 성분 분석을 수행하여, 고체연료, 비료 및 사료로 활용방안을 검토하였다. 무인자율이동 조류포집장치는 실증화 규모로 제작하여 기선정된 테스트베드에서 현장적용성 평가를 수행할 예정이다. 본 연구를 통해 개발된 유해조류 포집 시스템은 기존의 녹조제거 방안을 보완하여 정체수역의 생태계 복원 및 친수공간의 환경개선 등에 적용되며, 무독화가 입증된 유해조류의 농업재료 자원화 기술은 고부가 상품 개발 및 환경폐기물 감축에 활용될 것이다.

  • PDF

A Study on Reducing Method for Stack Effect in High-rise Building (고층 건축물 연돌효과 저감 방법에 대한 연구)

  • Kim, Jin Soo
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.66-66
    • /
    • 2011
  • 중위도 이북의 건물에서 고층건물의 혹한기 연돌효과는 건물의 여러 가지 기능에 큰 영향을 미치며, 승강기 승강로는 화재시 차압 때문에 연기의 주된 전파통로가 된다. 외피의 밀폐성능을 높여 건물 내부의 연도효과를 줄일 수 있으나, 외피의 밀폐기능은 비상시 피난을 위해 피난경로를 개방하는 순간 일시에 무력화된다. 또한 건물 외피의 밀폐성능이 우수할수록 연돌효과 그 자체로써 건물외피에 미치는 구조적 영향이 커진다. 고층부의 연돌효과는 외피를 밖으로 밀어내는 작용이므로 풍하측에서는 마이너스 풍압에 더하여 건물 외피에 부담을 증가시킨다. 그러므로 고층건물에 발생하는 혹한기 연돌효과의 영향을 정리하자면 다음과 같다. ${\bullet}$ 건물 외벽 및 창문에 미치는 구조적 영향 ${\bullet}$ 제연 시스템의 기능 저해 ${\bullet}$ 승강기 문 개폐 장애와 소음 등 설비 기능의 부정적 영향 ${\bullet}$ 공조기능 장애 ${\bullet}$ 화재시 승강기 승강로 등 수직 샤프트를 통한 연기 전파 혹한기 건물 안팎의 온도차가 40K일 때 높이 600m인 초고층 건물 최상층에 발생하는 연돌효과에 의한 차압은 풍속으로 환산할 때 32m/s에 달한다. 그러므로 초고층 건물 설계시에는 최상층의 풍하측에 설계상의 예상 최대풍속에다 이러한 환산풍속을 더한 고속 풍력이 창문을 밖으로 밀어내는 것으로 보아야 한다. 또한 공조 및 환기시스템에서는 이러한 차압을 고려하지 않으면 고층부에서 환기 성능이 무력화될 수 있다. 다음과 같은 방법들을 이용하여 고층건물의 연돌효과를 효과적으로 줄일 수 있다. 1) 계단실의 연돌효과 저감 방법 계단실에 발생하는 연돌효과에 의한 차압은 계단실에 상승기류를 발생시킨다. 이러한 차압과 상승기류는 계단실 상하부를 개방하면 자연적으로 평형을 이루게 되므로 별도의 제어가 필요 없게 된다. 또한 화재감지기와 연동하여 상하부 외벽의 개구부를 열어두게 되면 피난상황에 따라 문이 여닫힘으로써 발생하는 압력상태의 변화를 고려할 필요가 없게 된다. 2) 승강기 승강로의 연돌효과 승강로의 상하부에 대규모 개구를 두면 대규모의 외기가 도입되어 상승 유동 후 배출되므로 승강로 내부 온도 저하로 연돌효과가 저감되고, 승강로로 유입된 연기는 대규모의 외기에 희석되어 농도가 낮아지고 대부분 외부로 배출된다. 3) 샤프트 복합효과를 이용하는 방법 거실 평면적에 비해 승강기나 계단이 아주 많고 누설틈새 등 개구의 면적 합계가 크면 샤프트들이 서로 복합효과를 이루어 연돌효과에 의한 차압이 줄어든다. 연돌효과 제어용 샤프트를 하나 더 보조적으로 설치함으로써, 보조샤프트에 의해 발생하는 차압으로 거실을 가압 혹은 감압하여 문제가 되는 차압을 어느 정도 상쇄할 수 있다.

  • PDF

Structural Analysis of the Canister for PWR Spent Fuels under the Korean Reference Disposal Conditions (한국형 기준 처분 환경에서의 PWR 사용후핵연료 처분용기의 구조적 안전성 해석)

  • Choi Heui-Joo;Lee Yang;Choi Jong-Won;Kwon Young-Joo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.3
    • /
    • pp.301-309
    • /
    • 2006
  • KDC-1 canister for PWR spent fuels which will be used for the Korean Reference Disposal System was developed. The structural analysis of the canister was carried out as a part of the safety analysis. Two conditions, disposal condition and handling condition, were considered for the structural analysis. Three kinds of load cases, normal, abnormal and rock movement, were considered for the disposal condition. The results of the calculation showed that the safety factors from the structural analysis were greater than the design requirements. Two accident scenarios, gripper failure accident and canister drop accident, were analyzed for the handling condition. According to the gripper failure scenario analysis, the handling machine with grippers could be used even in the cases that one or two grippers failed. The maximum von Mises stress from the canister drop accident scenario was 0.762 MPa, which was negligible compared with the yield stress of nodular cast iron. The proposed KDC-1 canister for PWR spent fuels proves to be safe under the repository condition that is based upon the Korean reference disposal system according to the structural analysis for disposal condition and handling condition.

  • PDF

The Study on the Effect of Elevator Movement on the Pressure Difference between Vestibule and Living room in High-rise Buildings (초고층 건축물에서 엘리베이터 구동이 부속실과 화재실 간 차압형성에 미치는 영향연구)

  • Park, Younggi;Hong, Kibea;Ryou, Hong Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.85-91
    • /
    • 2018
  • Recently, there have been a lot of casualties due to fires in high-rise buildings. The toxic gases and smokes generated by fires in high-rise buildings spread rapidly through the elevator shaft and stairwell, due to the stack effect, and can cause critical casualties. To reduce the number of casualties, smoke control systems have been introduced. Smoke control systems play an essential role in preventing the spread of smoke in high-rise buildings and securing the evacuation route. Also, in high-rise buildings, evacuation by an elevator is considered to be indispensable. However, the pressure field in the shaft is strongly disturbed when the elevator is moving and this can affect the performance of the smoke control system. Therefore, in this study, we experimentally and numerically analyzed the effect of elevator movement on the pressure difference between the vestibule and living room by building a model using the sandwich pressurization method based on the performance based design. To consider the leakage areas in high-rise buildings, e.g. the windows, fire door and elevator, the National Fire Safety Codes and area ratio were used. The elevator speed in the model building was varied between 20 m/s and 100 m/s corresponding to a real elevator speed of 7 m/s~17 m/s. As a result, the relationship between the pressure difference and elevator speed was found to be ${\Delta}P=40{\cdot}{\exp}$(-Ves /-104.7)-23.735. This result can be used to take into consideration the effect of elevator movement when designing smoke control systems.