• 제목/요약/키워드: 가스치환

검색결과 168건 처리시간 0.023초

석탄 가스화 용융 슬래그를 혼합 잔골재로 사용한 FA 치환 콘크리트의 수화열 저감 (Reduction of Hydration heat of FA concrete using Coal Gasification Slag for Mixed Fine Aggregate)

  • 한준희;이영준;최일경;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.79-80
    • /
    • 2019
  • This study was intended to examine the possibility of reducing hydration heat by FA substitution and combination of slag (CGS) from coal gasification power generation (IGCC) with mixed aggregate for concrete. The analysis results showed good results if liquidity increases as the ratio of CGS increases, air volume decreases, and compressive strength is mixed up to 25% in the residual aggregate. The results showed that the heat of hydration was reduced compared to plain due to the boron content of CGS as the CGS substitution rate increased, but it was larger due to the combination with FA substitution. It was found that the heat of hydration was reduced.

  • PDF

공기주입방식에 의한 매립지가스 안정화에 관한 현장연구 (Field Study on Stabilization of Landfill Gas by Air Injection Mode)

  • 김경;박준석
    • 한국지반환경공학회 논문집
    • /
    • 제7권4호
    • /
    • pp.63-71
    • /
    • 2006
  • 본 연구에서는 공기주입 방식과 공기주입 시간이 매립지가스 안정화에 미치는 영향을 평가하고 매립지굴착사업 진행시 굴착작업 시간을 판단하고자 실시하였다. 간헐주입의 경우 혐기성에서 호기성으로의 전환되는데 연속주입보다 8배 정도 긴 시간이 소요되어 매립지굴착사업과 같이 혐기성 가스를 빠른 시간 내에 호기성 가스로 치환하여 굴착작업을 수행해야 하는 경우에는 연속주입이 더 적합할 것으로 판단되었다. $0.2m^3/min$ 유량으로 공기를 연속주입한 후 중단하였을 때 공기주입 시간과 호기성 조건($CH_4$ < 5%)이 유지되는 시간과는 비교적 높은 상관도($r^2$ = 0.95)를 나타내고 있었다. 공기주입 시간을 1이라고 볼 때 공기주입 중단 후 호기성은 약 1.5배 정도의 긴 기간 동안 유지되고 있었다.

  • PDF

가스하이드레이트 포화율 및 감압률에 따른 해리특성 분석 (The Analysis of Dissociation Properties According to Gas Hydrate Saturation and Depressurization Rate)

  • 안승희;전보현
    • 한국가스학회지
    • /
    • 제19권3호
    • /
    • pp.54-59
    • /
    • 2015
  • 가스하이드레이트(GH: Gas Hydrate)는 전 세계적으로 약 10조 톤에 이르는 엄청난 양이 대부분 해양의 대륙사면에 부존되어 있으나(동토 지역 : 2 %, 해양 대륙사면 98 %), 현재까지 가스하이드레이트 저류층으로부터 상업화할 수 있을 만큼 가스를 회수하는 기술이 개발되어 있지 않은 실정이다. 일반적으로 회수하는 방법은 감압법, 열자극법, 억제재 주입법 및 치환법 등으로 크게 나누어 볼 수 있으며, 본 연구에서는 가스하이드레이트 포화율과 감압률에 따라서 가스하이드레이트 해리시간 및 가스생산이 어떻게 달라지는 지, 그에 대한 특성을 분석하고자 하였다. 연구분석 결과 감압률과 해리시간의 상관 관계식을 도출($Y=0.0004X^2-0.499X+176.86$)할 수 있었고, 또한 감압률이 클수록 메탄생산량이 좋다는 것을 알 수 있었지만(감압률 40% 대비 50%에서 메탄가스생산량이 46.2% 향상), 감압률이 60%에서는 오히려 생산량이 줄어드는데, 이는 가스하이드레이트 재형성에 기인한 것으로 판단된다.

메탄하이드레이트 개발동향 (The Status of Methane Hydrate Development)

  • 김영인
    • 자원환경지질
    • /
    • 제46권1호
    • /
    • pp.71-84
    • /
    • 2013
  • 대부분의 GH는 전세계 해양퇴적물에서 대부분 산출되며 매장량은 $10^{13}{\sim}20{\times}10^{15}m^3$로 현재 세계 에너지 사용량을 기준으로 근 1,000년에 해당하는 양이다. MH는 전통석유가스자원를 대체할 미래 천연가스자원으로써의 잠재력이 있기 때문에 감압법, 화학첨가제 주입법, 열자극법, $CO_2$-메탄 치환법 등 채굴기술개발이 필요하다. 우리나라의 경우 2014년까지는 시험생산이 가능할 것으로 기대되고 있다. 이를 위하여 생산방법을 비교하고 GH의 분해에 따르는 반응이 복잡하기 때문에 이러한 현상을 예측하는 기술과 효과적이고 환경 친화적인 가스를 생산할 수 있는 기술을 개발하는 것이다.

FA시멘트 및 CGS 치환율에 따른 콘크리트의 단열온도상승 특성 (Characteristics of Adiabatic Temperature Rise for Concrete according to FA Cement and CGS Replacement Rate)

  • 백성진;후윈야오;김수호;한준희;윤치환;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.117-118
    • /
    • 2022
  • In this study, adiabatic temperature rise of concrete depending on binder compositions and CGS contents is studied to provide informations for CGS low-heating aggregate and mixture designs for upper and lower placement lifts. Test nresults indicate that it is desirable to apply the combination of binders between top and bottom lift. For top lift, SESC or ESC is recommended, and for bottom lift, FAC+CGS 50 % is good for material composition.

  • PDF

저발열 결합재 및 CGS를 잔골재로 치환한 매스콘크리트의 수화열 해석 (Hydration Heat Analysis of Mass Concrete Replacement of Low Heat Binder and CGS with Fine Aggregate)

  • 한준희;임군수;최일경;윤치환;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.235-236
    • /
    • 2021
  • This study evaluated temperature distribution through adiabatic temperature rising test and hydration heat Analysis as a performance verification to utilize CGS as a hydration heat reduction material for mass concrete when replacing it with fine aggregate. According to the analysis, the temperature difference between the center and the surface was the highest at about 30℃, followed by the CGS 50% at 26℃ and the low heat combiner FA 30% at 23℃.

  • PDF

유해가스 처리를 위한 Confined Plasma Source 개발 (Development of Confined Plasma Source for Hazardous Gas Treatment)

  • 윤용호
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권3호
    • /
    • pp.135-140
    • /
    • 2020
  • 반도체 공정에서 필수적인 공정가스가 유해가스이기 때문에 이를 친환경적으로 해결하는 것이 필수과제이다. 현재 반도체 공정에서 사용되는 세정기술은 대부분이 1970년대 개발된 과산화수소를 근간으로 하는 습식 세정으로, 표면의 입자를 제거하기 위한 SC-1 세정액은 암모니아와 과산화수소 혼합액을 사용하고 있다. 따라서 환경적 문제를 유발하며, 또한 과도한 용수 사용으로 인한 경제적 문제도 심각하다. 이러한 이유로 본 연구를 통한 개발 제품은 챔버 출구에서 나오는 공정 유해가스를 진공펌프에 입력되기 전 가스를 분해하여 해가 없는 가스로 만들거나 소각과 동시에 펌프에 가스의 성분이 증착되어 반도체 공정의 환경적 문제를 해결하고자 한다. 본 논문에서는 반도제 공정에서 필수 불가결하게 사용되는 유해가스(N2, CF4, SF6⋯. 등)를 사람에게 무해한 가스로 치환하거나 플라스마로 소각하여 환경을 살리고 생산성 향상이 되도록 제안된 CPS (Confined Plasma Source)를 연구하고자 한다.

제올라이트(faujasite)를 이용한 치환탈착공정에서 에탄, 에틸렌의 흡, 탈착 동특성 (Adsorption and Desorption Dynamics of Ethane and Ethylene in Displacement Desorption Process using Faujasite Zeolite)

  • 이지인;박종호;범희태;이광복;고창현;박성열;이용택;김종남
    • Korean Chemical Engineering Research
    • /
    • 제48권6호
    • /
    • pp.768-775
    • /
    • 2010
  • 제올라이트(faujasite) 흡착제가 충진된 흡착탑에서 에탄/에틸렌 혼합가스의 흡착 동특성과 탈착제로 프로판을 이용한 치환탈착 시의 동특성을 실험 및 이론적으로 연구하였다. 물질수지와 에너지수지를 고려하고 다성분 흡착평형으로 이상흡착상 모델을 적용한 전산모사는 흡탈착 파과곡선 실험 결과를 잘 예측하였다. 흡착파과 시 에탄의 롤-엎은 흡착압력이 높고, 온도가 낮을수록 증가하였다. 에탄/에틸렌 혼합가스로 포화된 흡착탑으로 탈착제인 프로판을 주입하여 치환탈착할 때 탈착단계의 일정 시간 동안에 거의 100%에 가까운 에틸렌을 얻을 수 있었다. 탈착제의 흡착세기는 에틸렌의 탈착 및 재흡착 시에 큰 영향을 미치는 것으로 나타났다. 프로판 대신 흡착세기가 강한 이소부탄을 탈착제로 사용한 경우에 탈착단계 후 재흡착에서 에틸렌 흡착용량이 많이 감소하는 현상이 관찰되었다. 전산모사를 통하여 ${(q_s{\times}b)}_{C_2H_4}/{(q_s{\times}b)}_{C_3H_s}$의 비율이 0.83일 때, 즉 탈착제와 에틸렌이 거의 유사한 정도의 흡착세기를 가질 때 치환탈착공정의 성능이 우수하였다.

대기조성 치환 및 압력이 Jet A1 액적화염의 매연입자 생성에 미치는 영향에 관한 연구 (Effects of Atmospheric Composition Substitution and Pressure on Soot Formation of Jet-A1 Droplet Flames)

  • 남원식;류명호;이종원;박설현
    • 한국화재소방학회논문지
    • /
    • 제33권5호
    • /
    • pp.13-18
    • /
    • 2019
  • 본 연구에서는 한국형발사체와 유사한 작동환경에서 Jet A1 액체연료의 매연 입자특성에 대해 농도를 측정함으로써 그 결과를 고찰하였다. 발사체환경과 유사한 대기 조건을 모사하기 위해 연소챔버의 산소 농도를 30%로 유지하고 내부 압력을 0.06 MPa에서 0.1 MPa 까지 변화시켜가며 실험을 통해 수행하였고, 대기의 조성을 질소, 헬륨, 이산화탄소 가스로 치환하여 실험을 수행하였다. 직경이 2 mm인 Jet-A1 액적에 동일한 점화에너지를 인가하여 발생 되는 매연 입자의 농도를 전역 광소멸 기법을 이용하여 측정하였다. Jet-A1 액적 화염의 매연 입자입자의 농도는 모든 압력조건에서 대기의 조성이 질소로 치환된 경우 높았으며, 이산화탄소로 치환된 경우 가장 낮았다. 압력이 낮아질수록 매연의 입자농도가 감소하였고, 대기압력의 Pn 형태로 감소하는 경향을 확인하였다.

안트라사이트를 활용한 산화마그네슘 보드의 실내 공기질 중 라돈가스 농도 저감 평가 (Evaluation of Decreasing Concentration of Radon Gas for Indoor Air Quality with Magnesium Oxide Board using Anthracite)

  • 편수정;임현웅;이상수
    • 한국건축시공학회지
    • /
    • 제18권1호
    • /
    • pp.9-15
    • /
    • 2018
  • 지구상에 존재하는 라돈가스는 바위, 토양, 건축자재 등에서 방출되는 1급 발암물질로 유일한 기체상으로 존재하고 있다. 공기에 비해 무겁고 분자량이 커 하부에 가라앉아 있지만 이동성이 크다. 라돈가스는 특성상 실외에서 대기에 확산되지만 밀폐되고 환기가 어려운 실내공간의 농도는 수천 배까지 증가할 수 있다. 이러한 라돈가스의 위해성을 해결하기 위해 안트라사이트를 활용한 경화체의 라돈가스 저감 특성과 더불어 실내 마감재로 사용할 수 있는 기초 성능평가를 진행하였다. 기존 여과재로 사용된 안트라사이트를 사용하여 경화체를 제작하였으며, 기존 실내에서 사용된 건축자재 중 라돈을 방출하는 석고보드를 대체할 수 있는 시험을 진행하였다. 결합재로는 경소 마그네시아를 사용하였고, 경소마그네시아의 경화를 위해 염화마그네슘을 사용하였다. 흡착재로 사용된 안트라사이트의 치환율은 0, 10, 20, 30, 40, 50 (%)로 총 6수준으로 진행하였으며,W/B는 40%로 고정하였다. 시험항목은 휨파괴 하중, 열전도율, 라돈가스 농도를 진행하였으며, 양생조건은 항온항습 양생(습도 $80{\pm}5%$, 온도 $20{\pm}2^{\circ}C$)으로 진행하였다.