• Title/Summary/Keyword: 가스측정시스템

Search Result 477, Processing Time 0.025 seconds

Measurement of Bubble Size in Flotation Column using Image Analysis System (이미지 분석시스템을 이용한 부선컬럼에서 기포크기의 측정)

  • An, Ki-Seon;Jeon, Ho-Seok;Park, Chul-Hyun
    • Resources Recycling
    • /
    • v.29 no.6
    • /
    • pp.104-113
    • /
    • 2020
  • Bubble size in froth flotation has long been recognized as a key factor which affects the bubble residence time, the bubble surface area flux (Sb) and the carrying rate (Cr). This paper presents method of bubble size measurement, relationship between operating variables and gas dispersion properties in flotation column. Using high speed camera and image analysis system, bubble size has been directly measured as a function of operating parameters (e.g., superficial gas rate (Jg), superficial wash water rate (Jw), frother concentration) in flotation column. Relationship compared to measured and estimated bubble size was obtained within error ranges of ±15~20% and mean bubble size was 0.718mm. From this system the empirical relationship to control the bubble size and distribution has been developed under operating conditions such as Jg of 0.65~1.3cm/s, Jw of 0.13~0.52cm/s and frother concentration of 60~200ppm. Surface tension and bubble size decreased as frother concentration increased. It seemed that critical coalescence concentration (CCC) of bubbles was 200ppm so that surface tension was the lowest (49.24mN/m) at frother concentration of 200ppm. Bubble size tend to increase when superficial gas rate (Jg) decreases and superficial wash water rate Jw and frother concentration increase. Gas holdup is proportional to superficial gas rate as well as frother concentration and superficial wash water rate (at the fixed superficial gas rate).

Development and Performance Test of Gas Safety Management System based on the Ubiquitous Home (u-home 가스안전관리시스템 개발 및 성능시험)

  • Park, Gyou-Tae;Lyu, Geun-Jun;Kim, Young-Gyu;Kim, Yeong-Dae;Jee, Cha-Wan;Kwon, Jong-Won;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.3
    • /
    • pp.13-20
    • /
    • 2011
  • In this paper, we proposed a system to raise gas safety management by using the wireless communication module and intelligent gas safety appliances. Our designed systems configure a micom-gas meter, an automatic extinguisher, sensors, and a wallpad. A micom-gas-meter monitors gas flow, gas pressure, and earthquake. An automatic fire extinguisher checks gas(combustible) leaks and temperature of $100^{\circ}C$ and $130^{\circ}C$. Sensors measure smoke and CO gas. In our novel system, a micom-gas meter cut off inner valve with warnings, an automatic fire extinguisher cut off middle valve and spray extinguishing materials, and sensors generate signals for smoke and CO when occurring gas risk. Gas safety appliances and sensors takes safety measures, and transmit those signal to a wallpad. The wallpad again transmit signal like events to a control server. Users can connect web pages for gas safety through B-ISDN and control and manage them. We hereby devised scenarios for gas safety and risk management, and demonstrated their effectiveness through experiments.

A Study on the Analysis of Safety Standard and Evaluation of Safety Performance for the 5 Nm3 /hr Class Alkaline Water Electrolysis System (5 Nm3 /hr급 알카라인 수전해 시스템 안전기준 분석 및 안전성능 평가에 관한 연구)

  • Kim, Ji-Hye;Lee, Eun-Kyung;Kim, Min-Woo;Oh, Gun-Woo;Lee, Jung-Woon;Kim, Woo-Seop
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.65-75
    • /
    • 2018
  • The wind energy produced at night is being discarded because of the excess power generated at night compared to daytime. To solve this problem, In this study, we analyzed the evaluation contents for evaluation of domestic and overseas water electrolysis systems and drew contents for safety performance contents test of the water electrolysis system based on the evaluation contents. The test contents produced the efficiency measurement test, the hydrogen generated pressure test, and the hydrogen purity test. And the safety performance evaluation of the alkaline water electrolysis system of $5Nm^3/hr$ was performed based on the results. As a result, the hydrogen generation was calculated as $5.10Nm^3/hr$ and the stack efficiency was $4.97kWh/Nm^3$. The purity of the hydrogen generated was 99.993% and it was confirmed that it produced high purity hydrogen. I think will help us assess and build safety performance of water electrolysis systems in the future.

Development and Field Test of a Smart-home Gas Safety Management System (스마트 홈 가스안전관리 시스템 개발 및 현장시험)

  • Park, Gyou-Tae;Kim, Eun-Jung;Kim, In-Chan;Kim, Hie-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.128-135
    • /
    • 2012
  • In this paper, we proposed a system and a scenario to raise efficiency of gas safety management by developing wireless ZigBee communication modules, smart-home gas safety appliances and the system suitable for gas safety. Our designed system consists of a micom gas meter, an automatic extinguisher, sensors, and a wall-pad. A micom-gas-meter monitors gas flow, gas pressure, and earthquake. An automatic fire extinguisher checks combustible gas leaks and temperature of $100^{\circ}C$(cut off) and $130^{\circ}C$(fire). Sensors measure smoke and CO gas. In our novel system, a micom-gas meter cut off inner valve with warnings, an automatic fire extinguisher cut off middle valve and spray extinguishing materials, and sensors generate signals when detecting smoke and CO and then take a next action. Gas safety appliances and sensors automatically takes measures, and transmit those information to a wall-pad. The wall-pad again transmits real time information to server. Users can check and manage gas safety situations by connecting BcN server through web or mobile application. We hereby devised scenarios for gas safety and risk management based on the smart, and demonstrated their efficiency through test applied to filed.

Development of System for Measuring Evaporation Rate through Porous Medium in Fuel Cells (연료전지 다공성막을 통한 수분증발량의 정량적 측정에 관한 실험적 연구)

  • Kim, Jong-Rok;Kim, Moo-Hwan;Son, Sang-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.579-582
    • /
    • 2012
  • Removing residual water in a fuel cell is a critical operational process for managing its performance and controlling its lifetime. Understanding the mechanism of water transport in fuel cells is essential for the design of the water removal process. In this study, an experimental method for measuring the water evaporation rate through a gas diffusion layer, which is a porous medium, under steady-state conditions was developed. Experimental bench tests were conducted to apply the developed method. Then, the effects of various parameters of the drying gas and the gas diffusion layer were experimentally measured. The water evaporation rate increased as the humidity of the drying gas decreased and the flow rate of the drying gas increased. In addition, a thinner gas diffusion layer yielded a higher water evaporation rate.

Development of System Dynamics Model and Integrated Tool for Safety Culture Diagnosis of a Combined-Cycle Power Plant (복합발전 플랜트 안전문화 진단을 위한 시스템 다이내믹스 모델링 및 통합도구 개발 연구)

  • Choi, Jaewoo;Um, Sungin;Hong, Inki
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.70-76
    • /
    • 2017
  • Although various methods have been tried to measure the safety culture of firms, they are limited to derive the qualitative analysis results according to the subjective criteria that are not formalized according to the evaluation method. We developed a questionnaire that can be applied to a combined power plant, quantified the evaluation results using the system dynamics model based on the results, and conducted simulation through various scenarios. And to present the criteria for safety cultural policy.

Development of Natural Gas Steam Reformier for Small Scale On-Site Production of Hydrogen (소규모 현장 생산 방식에 의한 수소 제조용 천연가스 수증기 개질기 개발)

  • Seo Dong Joo;Seo Yutaek;Seo Yong Seog;Park Sang Ho;Jeong Jin Hyeok;Yoon Wang Lai
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.264-267
    • /
    • 2005
  • 수소의 소규모 분산 생산 기술은 본격적 인 수소 인프라가 도입되기 전에 연료전지 자동차의 수소 충 전용이나 분산 발전형 연료전지의 수소 공급을 위해 필요하다. 생산 용량은 수소 기준으로 $10\~100 Nm^3/hr$ 정도로 현재로선 천연가스의 수증기 개질법이 가장 경제적인 공정으로 알려져 있다. 소규모 생산에 따른 열효율 저하를 줄이 기 위해 단위 공정들이 통합된 컴팩트 개질 시스템의 개발이 필요하다. 핵심 기술인 컴팩트 리포머의 국산화 기술 확보를 위하여 $20 Nm^3/hr$용량의 동심관형 리포머를 설계, 제작하였다. 내부구조는 제작의 단순화를 고려하여 중첩된 동심관이 배열되었고 압력 손실과 열웅력 발생을 억제하도록 유로를 배치하였다. 수증기개질 반응에 필요한 반응열은 리포머 본체에 부착된 버너를 이용하여 공급하였다. 성능 측정을 위한 부속 기기로 상온 흡착식 탈황기, 폐열 회수형 수증기 발생기, 반응물 예열을 위한 열교환기, 생성 가스 응축기를 설계 제작하여 전체 리포밍 시스템을 구성하였다. 반응 온도 $680\~720^{\circ}C$, 탄소 대 수중기 비(S/C ratio) $2.7\~3.2$ 조건에서 수증기 개질 반응을 수행하였다. 해당 반응 조건에서 메탄 전환율 $89\%$ 이상, 저위 발열량 기준 개질 열효율 $70\%$ 이상을 달성하였고 개질 생성가스 내 수소의 최대 유량은 $23.4Nm^3/h$였다. 개발된 리포밍 시스템은 고순도 수소 생산이 필요한 경우, 수소 수율 향상을 위한 고온 수성 가스 전화 반응기를 통합 가능하도록 열교환기 구성을 조정할 수 있으며 용융 탄산염 연료전지와 같이 고온형 연료전지의 경우 $550^{\circ}C$ 이상으로 개질 생성 가스를 공급하도록 구성할 수도 있다. 향후 리포머 본체의 개질 효율 향상 및 장치 소형화, 부속 기기의 최적화를 통한 전체 리포밍 시스템 개선, 스케일 업 설계를 위한 엔지니어링 설계 패키지 구성을 계획하고 있다.

  • PDF

A Study on the Development of Solid Reference Electrode and Remote Protection Potential Measuring System (고체기준전극 및 원격전위측정 시스템 개발에 관한 연구)

  • Ryou, Young-don;Kim, Jin-Jun;Kim, Dong-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.3
    • /
    • pp.38-43
    • /
    • 2015
  • For buried gas pipelines, cathodic protection system shall be installed to protect against corrosion. The surveys of pipe-to-soil potentials for the gas pipelines should be carried out at the test box more than once a year. In urban, the test box is usually located on the driveway, therefore, it is difficult to measure the potentials. That is, traffic control is needed when carrying out the measurements of the potentials on daytime, or measurements of pipe-to-soil potentials at the test box located on the driveway have to be carried out in the late night when the traffic is light. We have developed remote potential monitoring system using the solid reference electrode and the wireless communication technology for the purpose of removing above problems. We have installed the developed solid reference electrodes at a site and monitored the potentials by wireless communication. Measured potential values were transferred to the server in office and analyzed. We have found the pipe-to-soil potentials transferred to the web server make no difference to the potentials measured directly on the site.

The implementation of the health confirmation system through gas measurement (가스 측정을 통한 간편한 건강상태 확인 시스템 구현)

  • Hwang, Eun-Ji;Bae, Ki-Dong;Yim, Ho-Kyun;Yi, Gangman
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.04a
    • /
    • pp.78-80
    • /
    • 2015
  • 최근 현대인들에게 스마트 기기는 필수적인 부분이 되었고, 바쁜 일상을 보내기 때문에 시간을 절약할 수 있는 제품들이 주목받고 있다. 본 프로젝트는 아두이노와 스마트 기기의 통신을 이용하여 바쁜 현대인들이 일상생활 속에서도 생리현상을 통해 건강상태를 스스로 확인할 수 있는 디바이스를 구현하였다. 아두이노와 가스센서를 이용해 암모니아 및 여러 가스들의 농도를 측정하고, wifi 쉴드를 통해 데이터를 스마트 기기에 전달한다. 받아온 데이터를 분석하여 나온 건강정보를 사용자의 스마트 기기를 통해 출력 하도록 하여 일상생활에서 자신의 건강을 체크할 수 있게 하였다.

Simulation of Exhaust Temperature of Gas Turbine Generator using Operating Data (운전데이터에 의한 가스터빈 발전기의 배기가스온도 계통 모델링 및 시뮬레이션에 관한 연구)

  • 우주희
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.10a
    • /
    • pp.176-180
    • /
    • 1999
  • 미지 플랜트의 인식방법은 크게 두 가지로 나눌 수 있으며, 하나는 연역적 방법으로서 대상 플랜트에 대한 열적·유체 역학적 법칙을 사용하여 물리적으로 모델을 수식화하는 방식이고, 다른 하나는 귀납적 방법으로서 측정된 입출력데이터에 의해 역으로 구조를 찾아가는 방식이다. 본 논문에서는 후자의 방법으로 가스터빈 발전소의 배기가스 온도계통 모델을 구하기 위해 현장에서 운전 데이터를 취득하였다. 그리고 컴퓨터 시뮬레이션을 통해 경험적으로 구현한 모델이 실제 운전데이터와 유사한 특성을 보임을 알 수 있었다. 이렇게 구현된 모델은 향후 발전소용 가스터빈 제어시스템을 새로이 구축하거나 튜닝하고자 할 때 배기가스 온도제어계통을 설계하는데 기초자료로 활용할 수 있다.

  • PDF