• Title/Summary/Keyword: 가스압

Search Result 522, Processing Time 0.023 seconds

Design Point Operating Characteristics of an Oxidizer Rich Preburner (산화제 과잉 예연소기 설계점 운영 특성)

  • Moon, Ilyoon;Moon, Insang;Kang, Sang Hun;Ha, Seong-Up;Lee, Soo Young
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.4
    • /
    • pp.81-88
    • /
    • 2013
  • It was designed and tested at the design point that an oxidizer rich preburner for a staged combustion liquid rocket engine propelled by kerosene and LOx. The oxidizer rich preburner was designed as some of LOx injected from the mixing head was burned with kerosene and the rest of LOx injected from injection holes in the regenerative cooling chamber was vaporized by combustion gas. The preburner is operated at OF ratio of 60 and combustion pressure of 20 MPa. The Preburner has a honey-comb type mixing head with simplex swirl injectors, a turbulence ring improving combustion stability and uniformity of product gas temperature distribution, and a nozzle simulating the duct. With the combustion test results at the design point, the oxidizer rich preburner showed high combustion stability and uniformity of product gas temperature distribution.

Analysis of Emissions of Agricultural Tractor according to Engine Load Factor during Tillage Operation (엔진 부하율에 따른 트랙터 경운 작업 시 배기가스 분석)

  • Lee, Jun Ho;Jeon, Hyeon Ho;Baek, Seung Yun;Baek, Seung Min;Kim, Wan Soo;Siddique, Md. Abu Ayub;Kim, Yong Joo
    • Journal of Drive and Control
    • /
    • v.19 no.4
    • /
    • pp.54-61
    • /
    • 2022
  • This is a basic study analyzing emissions of an agricultural tractor during tillage operations. In this study, CO, THC, NOx, and PM considered as emission factor were analyzed during plow and rotary tillage operation by the tractor. Engine torque and rotational speed were measured through ECU. Engine power was calculated using engine torque and rotational speed. The emissions was calculated based on the number of units, rated power, load factor, and operating time. Results showed that the load factor was calculated almost twice, which was higher than 0.48. It was also observed that the emission of the tractor was variable for different agricultural operations because tractor loads were different based on operations. There was a difference in emissions due to differences in plow and rotary working hours. To estimate the emission of agricultural tractor based field operations in detail, it is necessary to consider TAF (Transient Adjustment Factor) and DFA (Deterioration factor). In the future, TAF and DFA will be considered to estimate emissions of the agricultural tractor. Finally, results of this study can contribute to the literature to estimate tractor emissions accurately.

Design of a Height Adjustable Bunker Bed Using a Gas Spring (가스 스프링을 이용한 높이조절 벙커침대 설계)

  • Jung, Gyuhong
    • Journal of Drive and Control
    • /
    • v.18 no.4
    • /
    • pp.19-27
    • /
    • 2021
  • A bunker bed is a type of furniture that efficiently utilizes a narrow indoor space by having a high bed and using the empty space below as a living and storage space. The demand for multi-purpose furniture is increasing due to the recent increase in single-person households and wide-spread shared accommodation. According to the consumer research, one of the major drawbacks of a bunker bed was to get on and off the bed through a ladder or stairs. In order to overcome these problems, it was confirmed that the height adjustment function that can easily adjust the minimum and maximum heights of the bed was necessary. In this study, a height adjustable bunker bed was designed by using a gas spring that generates a repulsive force by the compressed gas inside. The design process consisted of the following three steps: Firstly, the hysteresis characteristics due to a friction and spring constant of a commercial gas spring were confirmed by measuring the repulsive force vs. compressed displacement. Secondly, requirements of the vertical lifting force exerted on the bed against gravity force were derived. Finally, the height-adjustable bed using the four-bar link mechanism was designed with 4 parameters so that the bed weight of 60-70 kgf could be adjusted to 800 mm in height by an affordable initial operation force. The performance was verified through prototype production and the results of vertical displacement and force to move were nearly the same as designed. In addition, an electrically operated height-adjustable bed was also designed with linear actuators and the performance was proved with the prototype.

Changes of Blood Gases, Plasma Catecholamine Concentrations and Hemodynamic Data in Anesthetized Dogs during Graded Hypoxia Induced by Nitrous Oxide (아산화질소에 의한 점진적 저산소가스 흡입이 혈중 가스치와 Catecholamine치 및 혈역학에 미치는 영향)

  • Kim, Sae-Yeon;Song, Sun-Ok;Bae, Jung-In;Cheun, Jae-Kyu;Bae, Jae-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.1
    • /
    • pp.97-113
    • /
    • 1998
  • The sympathoadrenal system plays an important role in homeostasis in widely varing external environments. Conflicting findings, however, have been reported on its response to hypoxia. We investigated the effect of hypoxia on the sympathoadrenal system in dogs under halothane anesthesia by measuring levels of circulating catecholamines in response to graded hypoxia. Ten healthy mongreal dogs were mechanically ventilated with different hypoxic gas mixtures. Graded hypoxia and reoxygenation were induced by progressively decreasing the oxygen fraction in the inhalation gas mixture from 21%(control) to 15%, 10% and 5% at every 5 minutes, and then reoxygenated with 60% oxygen. Mean arterial pressure, central venous pressure and mean pulmonary arterial pressure were measured directly using pressure transducers. Cardiac output was measured by the thermodilutional method. For analysis of blood gas, saturation and content, arterial and mixed venous blood were sampled via the femoral and pulmonary artery at the end of each hypoxic condition. The concentration of plasma catecholamines was determined by radioenzymatic assay. According to the exposure of graded hypoxia, not only did arterial and mixed venous oxygen tension decreased markedly at 10% and 5% oxygen, but also arterial and mixed venous oxygen saturation decreased significantly. An increased trend of the oxygen extraction ratio was seen during graded hypoxia. Cardiac output, mean arterial pressure and systemic vascular resistance were unchanged or increased slightly. Pulmonary arterial pressure(PAP) and pulmonary vascular resistance(PVR) were increased by 55%, 76% in 10% oxygen and by 82%, 95% in 5% oxygen, respectively(p<0.01). The concentrations of plasma norepinephrine, epinephrine and dopamine increased by 75%, 29%, 24% in 15% oxygen and by 382%, 350%, 49% in 5% oxygen. These data suggest that the sympathetic nervous system was activated to maintain homeostasis by modifying blood flow distribution to improve oxygen delivery to tissues by hypoxia, but hemodynamic changes might be blunted by high concentration of nitrous oxide except PAP and PVR. It would be suggested that hemodynamic changes might not be sensitive index during hypoxia induced by high concentration of nitrous oxide exposure.

  • PDF

The Effects of Inspiratory Pause on Airway Pressure and Gas Exchange under Same I:E ratio in Volume-controlled Ventilation (Volume-Controlled Mode의 기계환기시 동일환 I:E Ratio하에서 Inspiratory Pause가 기도압 몇 가스교환에 미치는 영향)

  • Choi, Won-Jun;Jung, Sung-Han;Lee, Jeong-A;Choe, Kang-Hyeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1022-1030
    • /
    • 1998
  • Background : In volume-controlled ventilation, the use of inspiratory pause increases the inspiratory time and thus increases mean airway pressure and improves ventilation. But under the same I : E ratio, the effects of inspiratory pause on mean airway pressure and gas exchange are not certain. Moreover, the effects may be different according to the resistance of respiratory system. So we studied the effects of inspiratory pause on airway pressure and gas exchange under the same I : E ratio in volume-controlled ventilation. Methods: Airway pressure and arterial blood gases were evaluated in 12 patients under volume-controlled mechanical ventilation with and without inspiratory pause time 5%. The I : E ratio of 1 : 3, $FiO_2$, tidal volume, respiratory rate, and PEEP were kept constant. Results: $PaCO_2$ with inspiratory pause was lower than without inspiratory pause ($38.6{\pm}7.4$ mmHg vs. $41.0{\pm}7.7$ mmHg. p<0.01). P(A-a)$O_2$ was not different between ventilation with and without inspiratory pause $185.3{\pm}86.5$ mmHg vs. $184.9{\pm}84.9$ mmHg, p=0.766). Mean airway pressure with inspiratory pause was higher than without inspiratory pause ($9.7{\pm}4.0\;cmH_2O$ vs. $8.8{\pm}4.0\;cmH_2O$, p<0.01). The resistance of respiratory system inversely correlated with the pressure difference between plateau pressure with pause and peak inspiratory pressure without pause (r=-0.777, p<0.l), but positively correlated with the pressure difference between peak inspiratory pressure with pause and peak inspiratory pressure without pause (r=0.811, p<0.01). Thus the amount of increase in mean airway pressure with pause positively correlated with the resistance of respiratory system (r=0.681, p<0.05). However, the change of mean airway pressure did not correlated with the change of $PaCO_2$. Conclusion: In volume-controlled ventilation under the same I : E ratio of 1 : 3, inspiratory pause time of 5% increases mean airway pressure and improves ventilation. Although the higher resistance of respiratory system, the more increased mean airway pressure, the increase in mean airway pressure did not correlated with the change in $PaCO_2$.

  • PDF

Tracheal gas insufflation (TGI) in patients with increased deadspace fraction: the effect and its determining factors (사강호흡율이 증가된 환자에서 기관내 가스주입법(Tracheal Gas Imsufflation)이 가스교환에 미치는 효과와 그 결정인자)

  • Lim, Chae Man;Jung, Bok Hyun;Koh, Youn Suck;Lee, Sang Do;Kim, Woo Sung;Park, Pyung Hwan;Kim, Dong Soon;Kim, Won Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.136-145
    • /
    • 1997
  • Background : Tracheal Gas Insufflation (TGI) is one of the newer ancillary measures in mechanical ventilation employed to enhance carbon dioxide elimination. TGI exerts its effect through reduction of deadspace ventilation, but the factors determining its effect are not well studied yet. Method : The subjects were seven mechanically-ventilated patients ($58.8{\pm}10.6$ yrs) who showed increased physiologic deadspace greater than 60%. After 30 nun of stabilization with 100% oxygen on pressure control ventilation, continuous flow TGI was administered via the insufflation lumen of Hi-Lo Jet Tracheal Tube (Mallincrodt, USA) for 15 min at 3 L/min and 5 L/min each. Results : $PaCO_2$ was decreased ($51.4{\pm}17.6$ at baseline, $49.1{\pm}18.9$ at TGJ 3 L/min $45.0{\pm}14.9$ mm Hg at TGI 5 L/min, p=0.050), and pH was increased ($7.37{\pm}0.12$, $7.38{\pm}0.13$, $7.39{\pm}0.12$, respectively, p=0.037) while mixed expired $CO_2$ ($P_ECO_2$) was not changed significantly from baseline (p=0.336) by TGI. Physiologic deadspace(Vdphy) was decreased ($73.0{\pm}7.9$% at baseline, $69.8{\pm}10.0$% at TGI 3 L/min, and $67.1{\pm}10.1$% at TGI 5 L/min, p=0.015). $AaDO_2$(p=0.147), Vt(p=0.2140), Pmean(p=0.7788) and mean arterial pressure(p=0.4169) were not changed. The correlation between % maximal decrease of Vdphy were r=0.790 with the ratio of baseline Vdana/Vdphy(p=0.035) and r=-0.754 with baseline Vdalv(p=0.050). Conclusion: TGI was effective in reducing $PaCO_2$ and deadspace, and the deadspace-reducing effect was best correlated with baseline anatomic/physiologic deadspace ratio.

  • PDF

Development of Probabilistic Wind Load Models (국내 풍하중의 확률적 모형 개발)

  • 김상효;배규웅;박홍석
    • Computational Structural Engineering
    • /
    • v.3 no.2
    • /
    • pp.109-115
    • /
    • 1990
  • The probabilistic characteristics of wind loads have been analyzed using statistical data on wind speeds, pressure coefficient, exposure coefficient, and gust factor. The wind speed data collected at 25 nationwide weather stations have been modified to be consistent in measuring height, exposure condition as well as averaging time. Having performed Monte Carlo simulation for various heights and site conditions, the statistical models of wind loads were determined, in which Type-I extreme value distribution has been applied. The models also incorporate a reduction factor of 0.85 to account for the reduced probability that the maximum wind speed will occur in a direction most unfavorable to the response of structure.

  • PDF

A Study on the Effect of the Atmospheric Pressure in the Gas Flow Measurement (대기압이 가스유량측정에 미치는 영향에 관한 연구)

  • Chung, Jong-Tae;Ha, Young-Cheol;Lee, Cheol-Gu;Her, Jae-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.363-369
    • /
    • 2002
  • Orifice meter is the most widely used flowmeter in custody transfer between KOGAS and city gas companies. Absolute pressure value is needed to calculate the gas flow of orifice metering system, but the gauge pressure transmitters are mainly used in the field. In case that the gauge pressure transmitters are used, the fixed value as standard atmospheric pressure(101.325kPa) is applied for the absolute pressure value. The real, local atmospheric pressures of each metering station are different from the standard condition as the altitude and weather conditions. In this study the flow calculation errors were quantitatively analyzed through examining the atmospheric pressures of 50 stations of KOGAS. The data for analysis are such like the time data of supplied gas amount, the altitude of each metering station, the time data of atmospheric pressures and altitudes of each weather observatory. The results showed that the local atmospheric pressures were different from the standard value and the gas flow calculation errors were distributed between $-0.024\%{\~}0.025\%$ based on the supplied gas amount in the year 1999 and 2000.

  • PDF

A study on multi-functional welder remote control system using smart phone (스마트 폰을 이용한 다기능 용접기 원격 제어 시스템에 관한 연구)

  • Kim, Gi-Hoon;Jeong, Yang-Kwon;Choi, Jae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.3
    • /
    • pp.351-358
    • /
    • 2014
  • In this study, we are a proposed system that could control a multi-functional welder of the current, voltage of the crater, gas control, the wire feeder's driven, the constant voltage output control, high frequency control, rated current control and the ARC welding control etc., using the mobile-based smart phone. Approximately 90% of user of proposed system are very useful in multi-function welder in their task responded and rest of 10% of the answers don't need it. 30% answered in 90% of the multi-function welding machine according to age group using a smart phone utilizing this "very difficult" at investigated. However, the use of smart phones is gradually lower the user's age group can be seen that effective.

Blood Pictures and Histochemical Properties of the Gastrointestinal Mucous Cells in the Viper (까치 살모사(Agkistrodon saxutilis)의 혈액학적 성상과 위장관 점막세포의 조직화학적 연구)

  • 노영복
    • The Korean Journal of Zoology
    • /
    • v.36 no.2
    • /
    • pp.159-174
    • /
    • 1993
  • 까치 살모사(AEkistrodon snatilis)의 활동기와 동면기에서 일반적인 혈액성상과 혈액내 가스함량의 변화 또한 위장관 점액세포에 대한 형태적 및 조직화학적 변화 양상을 규명 비교하고자 한다 활동기와 동면기에 까치 살모사의 혈액내 총이산화탄소량(TCO2). 이산화탄소부분압(PCO2), 산소압(PO2)과 pH는 활동기보다 동면기에 증가하였으며, 적혈구수, 혈색소, 적혈구 용적 백분율은 활동기보다 동면기에 약간 증가하는 경향이었다. 또한 백혈구수는 활동기보다 동면기에 뚜렷한 감소를 보였다 활동기와 동면기의 위점막에서는 현저한 차이는 없으나, 소장 점막은 동면기에 그 주름수가 감소하고 높이가 낮아지며 점액세포가 위축되었으며, 위 표면 점액세포는 활동기에 중성 점액질과 약간의 Sialomucin을 포함한 산성 점액질로 구성되었으나 동면기에는 중성 점액질과 Sialomucin이 약간 감소하였다 위점액경세포는 활동기에 중성 점액질만을 포함하고 있었으나. 동면기에는Sialomucin을 포함한 산성 점액질이 소량 검출되었다 소장 점액세포는 활동기에 산성점액질과 중성 점액질로 구성되었으며. 산성 점액질에는 Sulfomucin과 Sialomucirr이 포함되어 있었으나 동면기에는 Sulfomucin과 Sialomucin이 다소 감소하는 경향이었다 주사전자현미경 관찰을 통한 까치 살모사의 위장관 표면 상피세포의 미세구조적 변화는 각동면기 별로 차이를 인정할 수가 있었다. 위장관점 막 상피세포는 활동기에 비해 동면기에 상당한 구조적 위축현상을 보이는 경향을 알 수 있다.

  • PDF