• Title/Summary/Keyword: 가상카메라

Search Result 511, Processing Time 0.025 seconds

Pupil Data Measurement and Social Emotion Inference Technology by using Smart Glasses (스마트 글래스를 활용한 동공 데이터 수집과 사회 감성 추정 기술)

  • Lee, Dong Won;Mun, Sungchul;Park, Sangin;Kim, Hwan-jin;Whang, Mincheol
    • Journal of Broadcast Engineering
    • /
    • v.25 no.6
    • /
    • pp.973-979
    • /
    • 2020
  • This study aims to objectively and quantitatively determine the social emotion of empathy by collecting pupillary response. 52 subjects (26 men and 26 women) voluntarily participated in the experiment. After the measurement of the reference of 30 seconds, the experiment was divided into the task of imitation and spontaneously self-expression. The two subjects were interacted through facial expressions, and the pupil images were recorded. The pupil data was processed through binarization and circular edge detection algorithm, and outlier detection and removal technique was used to reject eye-blinking. The pupil size according to the empathy was confirmed for statistical significance with test of normality and independent sample t-test. Statistical analysis results, the pupil size was significantly different between empathy (M ± SD = 0.050 ± 1.817)) and non-empathy (M ± SD = 1.659 ± 1.514) condition (t(92) = -4.629, p = 0.000). The rule of empathy according to the pupil size was defined through discriminant analysis, and the rule was verified (Estimation accuracy: 75%) new 12 subjects (6 men and 6 women, mean age ± SD = 22.84 ± 1.57 years). The method proposed in this study is non-contact camera technology and is expected to be utilized in various virtual reality with smart glasses.

A Study on the Expression of Sense of Space in 3D Architectural Visualization Animation (3D 건축 시각화 애니메이션의 공간감 표현에 관한 연구)

  • Kim, Jong Kouk
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.369-376
    • /
    • 2021
  • 3D architectural visualization animation has become more important in architectural presentations due to the rapid development of digital technology. Unlike games and movies, architectural visualization animation most focuses on delivering visual information, and aims to express the sense of space that viewers feel in an architectural space, rather than simply providing an image of viewing buildings. The sense of space is affected not only by physical elements of architecture, but also by immaterial elements such as light, time, and human actions, and it is more advantageous to express it in animations that can contain temporality compared to a fixed image. Therefore, the purpose of this study is to search for elements to effectively convey a sense of space in architectural visualization animation. To this end, the works of renowned architectural visualization artists that are open to the public were selected and observed to search for elements to effectively convey a sense of space to viewers. The elements that convey the sense of space that are common to the investigated architectural animations can be classified into the movement and manipulation of the camera, the movement of surrounding objects, the change of the light environment, the change of the weather, the control of time, and the insertion of a surreal scene. It will be followed by a discussion on the immersion of architectural contents.

A Study on the Digital Holographic Image Acquisition Method using Chroma Key Composition (크로마키 합성을 이용한 디지털 홀로그래피 이미지 획득 방법 연구)

  • Kim, Ho-sik;Kwon, Soon-chul;Lee, Seung-hyun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.313-321
    • /
    • 2022
  • As 5G is getting developed, people are getting interested in immersive content. Some predicts that immersive content may be implemented in real life such as holograms, which were only possible in movies. Holograms, which has been studied for a long time since Dennis Gabor published the basic theory in 1948, are constantly developing in a new direction with digital technology. It is developing from a traditional optical hologram, which is produced by recording the interference pattern of light to a computer generated hologram (CGH) and a digital hologram printer. In order to produce a hologram using a digital hologram printer, holographic element (Hogel) image must first be created using multi-view images. There are a method of directly photographing an actual image and a method of modeling an object using 3D graphic production tool and rendering the motion of a virtual camera to acquire a series of multi-view images. In this paper, we propose a new method of getting image, which is one of the visual effect, VFX, producing multi-view images using chroma key composition. We shoot on the green screen of actual object, suggest the overall workflow of composition with 3D computer graphic(CG) and explain the role of each step. We expected that it will be helpful in researching a new method of image acquisition in the future if all or part of the proposed workflow to be applied.

A Study on the Development of an Indoor Positioning Support System for Providing Landmark Information (랜드마크 정보 제공을 위한 실내위치측위 지원 시스템 구축에 관한 연구)

  • Ock-Woo NAM;Chang-Soo SHIN;Yun-Soo CHOI
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.4
    • /
    • pp.130-144
    • /
    • 2023
  • Recently, various positioning technologies are being researched based on signal-based positioning and image-based positioning to obtain accurate indoor location information. Among these, various studies are being conducted on image positioning technology that determines the location of a mobile terminal using images acquired through cameras and sensor data collected as needed. For video-based positioning, a method of determining indoor location is used by matching mobile terminal photos with virtual landmark images, and for this purpose, it is necessary to build indoor spatial information about various landmarks such as billboards, vending machines, and ATM machines. In order to construct indoor spatial information on various landmarks, a panoramic image in the form of a road view and accurate 3D survey results were obtained through c 13 buildings of the Electronics and Telecommunications Research Institute(ETRI). When comparing the 3D total station final result and the terrestrial lidar panoramic image coordinates, the coordinates and distance performance were obtained within about 0.10m, confirming that accurate landmark construction for use in indoor positioning was possible. By utilizing these terrestrial lidar achievements to perform 3D landmark modeling necessary for image positioning, it was possible to more quickly model landmark information that could not be constructed only through 3D modeling using existing as-built drawings.

Evaluation of the combination of Bone Scan Image and Pelvic X-ray Image (뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가)

  • Lee, Choong Woon;You, Yeon Wook;Kim, Yong Keun;Weon, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.23-27
    • /
    • 2018
  • Purpose The introduction of bone scan has been reported as a useful tool in the diagnosis, treatment, and treatment response of skeletal disease. The purpose of this study is to improve the anatomical information and tolerance of the bone by combining bone scan and pelvic X-ray without additional radiation exposure. Materials and Methods From November 2015 to August 2016, 236 patients(64 men and 172 women, average age $50.96{\pm}15.39years$) take Bone scan and Pelvis AP(Anteroposterior) X-ray scan at the National Cancer Center. The scan equipment was a gamma camera, Symbia Ecam (SIEMENS, Germany), and a digital x-ray, DRS-800 (Listem, Korea). Osirix version 3.8.1 (Osirix, USA) and Stata/SE version 14.0 (StataCorp, USA) were used for image combination and analysis. The patient was intravenously injected with $^{99m}Tc-DPD$ (740 MBq), and the scan was performed 2 to 4 hours later. Gamma camera image acquisition were Matrix size $256{\times}1024$, Zoom 1.00, and scan speed 17 cm/min. The digital X-ray was made with a collimator size of $14^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$, 77 kVp (60 to 97 kVp) and an average of 30 mAs (20 to 48). ASIS and pubic symphysis Select virtual points then Combine three virtual points and pelvic contour lines. The acquired images were evaluated by three radiologists who worked for more than 5 years in the nuclear medicine department. Results Of the total 236 patients, 216 (91.53%) were matched. The median and range (min~max) of the age were 67 (46~81) years old in the unmatched group and 52 (22~87) years old in the matched group, The Wilcoxon rank-sum test was performed to determine whether age was different between the two groups. As a result, the age difference between the two groups was statistically significant at p < 0.0001. Of the 64 men, 60 (93.75%) were match and of the 172 women, 156 (93.75%) were match. There was no statistically significant difference according to gender(p = 0.4542). Of the 54 patients without pelvic lesions, 54 (100.00%) were match, and 162 (89.01%) of 182 patients with pelvic lesions were match. There was a statistically significant difference according to the presence of pelvic lesions. Conclusion There are many variables in the combination of bone scan and pelvic X-ray imaging, and the patient's age and pelvic lesion may have some effect on the image combination. This study is expected to be useful for the diagnosis of pelvic osteosarcoma of children without radiation exposure. It is expected that this combination of images will help to develop the nuclear medicine image.

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

The Correlation between the Number of Fungiform Papillae and Electrogustometric Thresholds in Adults (젊은 성인에서 심상유두개수와 전기미각역치의 상관성)

  • Han, Dong-Hoon;Park, Ji-Il;Lim, Hoi-Soon;Kim, Jae-Hyung
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2011
  • The aims of this study were to establish the effect of gender and age on number of fungiform papillae and electrogustometric thresholds of the tongue, and to determine the relation between number of fungiform papillae and electrogustometric threshold. Sixty-two healthy subjects of 20 to 39 years old were enrolled in this study. Examination areas were defined as center, anterior, left lateral, right lateral, and posterior on the dorsal surface of the tongue, which was stained with methylene blue dye and photographed with a scale bar on it. The number of fungiform papillae within $1\; cm^2$ square area of each examination site was counted twice. The counted values were averaged to produce means. Taste thresholds were measured three times on each examination area using an electrogustometer. Means of the threshold values were calculated. 1. The number of fungiform papillae was the largest at the anterior examination area, followed by right lateral, left lateral, posterior and central. Women had more fungiform papillae than men at anterior, right lateral, and center areas. Subjects in twenties showed more fungiform papillae than those in thirties at anterior, right lateral, and left lateral areas. 2. Anterior area of the tongue measured the lowest electrogustometric threshold, followed by left lateral, right lateral, posterior and center. The threshold was higher in men at anterior and right lateral areas. The subjects in thirties had higher threshold only at right lateral area than those in twenties. 3. Electrogustometric threshold was inversely correlated with the number of fungiform papillae at anterior and posterior areas. The results showed that the number of fungiform papillae and taste threshold varied according to tongue locus, and they were influenced by age and gender. The results also suggested that the number of fungiform papillae was related to electrogustometric threshold inversely.

Preliminary Study for Imaging of Therapy Region from Boron Neutron Capture Therapy (붕소 중성자 포획 치료에서 치료 영역 영상화를 위한 예비 연구)

  • Jung, Joo-Young;Yoon, Do-Kun;Han, Seong-Min;Jang, HongSeok;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.151-156
    • /
    • 2014
  • The purpose of this study was to confirm the feasibility of imaging of therapy region from the boron neutron capture therapy (BNCT) using the measurement of the prompt gamma ray depending on the neutron flux. Through the Monte Carlo simulation, we performed the verification of physical phenomena from the BNCT; (1) the effects of neutron according to the existence of boron uptake region (BUR), (2) the internal and external measurement of prompt gamma ray dose, (3) the energy spectrum by the prompt gamma ray. All simulation results were deducted using the Monte Carlo n-particle extended (MCNPX, Ver.2.6.0, Los Alamos National Laboratory, Los Alamos, NM, USA) simulation tool. The virtual water phantom, thermal neutron source, and BURs were simulated using the MCNPX. The energy of the thermal neutron source was defined as below 1 eV with 2,000,000 n/sec flux. The prompt gamma ray was measured with the direction of beam path in the water phantom. The detector material was defined as the lutetium-yttrium oxyorthosilicate (Lu0,6Y1,4Si0,5:Ce; LYSO) scintillator with lead shielding for the collimation. The BUR's height was 5 cm with the 28 frames (bin: 0.18 cm) for the dose calculation. The neutron flux was decreased dramatically at the shallow region of BUR. In addition, the dose of prompt gamma ray was confirmed at the 9 cm depth from water surface, which is the start point of the BUR. In the energy spectrum, the prompt gamma ray peak of the 478 keV was appeared clearly with full width at half maximum (FWHM) of the 41 keV (energy resolution: 8.5%). In conclusion, the therapy region can be monitored by the gamma camera and single photon emission computed tomography (SPECT) using the measurement of the prompt gamma ray during the BNCT.

Inexpensive Visual Motion Data Glove for Human-Computer Interface Via Hand Gesture Recognition (손 동작 인식을 통한 인간 - 컴퓨터 인터페이스용 저가형 비주얼 모션 데이터 글러브)

  • Han, Young-Mo
    • The KIPS Transactions:PartB
    • /
    • v.16B no.5
    • /
    • pp.341-346
    • /
    • 2009
  • The motion data glove is a representative human-computer interaction tool that inputs human hand gestures to computers by measuring their motions. The motion data glove is essential equipment used for new computer technologiesincluding home automation, virtual reality, biometrics, motion capture. For its popular usage, this paper attempts to develop an inexpensive visual.type motion data glove that can be used without any special equipment. The proposed approach has the special feature; it can be developed as a low-cost one becauseof not using high-cost motion-sensing fibers that were used in the conventional approaches. That makes its easy production and popular use possible. This approach adopts a visual method that is obtained by improving conventional optic motion capture technology, instead of mechanical method using motion-sensing fibers. Compared to conventional visual methods, the proposed method has the following advantages and originalities Firstly, conventional visual methods use many cameras and equipments to reconstruct 3D pose with eliminating occlusions But the proposed method adopts a mono vision approachthat makes simple and low cost equipments possible. Secondly, conventional mono vision methods have difficulty in reconstructing 3D pose of occluded parts in images because they have weak points about occlusions. But the proposed approach can reconstruct occluded parts in images by using originally designed thin-bar-shaped optic indicators. Thirdly, many cases of conventional methods use nonlinear numerical computation image analysis algorithm, so they have inconvenience about their initialization and computation times. But the proposed method improves these inconveniences by using a closed-form image analysis algorithm that is obtained from original formulation. Fourthly, many cases of conventional closed-form algorithms use approximations in their formulations processes, so they have disadvantages of low accuracy and confined applications due to singularities. But the proposed method improves these disadvantages by original formulation techniques where a closed-form algorithm is derived by using exponential-form twist coordinates, instead of using approximations or local parameterizations such as Euler angels.

Matching Points Filtering Applied Panorama Image Processing Using SURF and RANSAC Algorithm (SURF와 RANSAC 알고리즘을 이용한 대응점 필터링 적용 파노라마 이미지 처리)

  • Kim, Jeongho;Kim, Daewon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.144-159
    • /
    • 2014
  • Techniques for making a single panoramic image using multiple pictures are widely studied in many areas such as computer vision, computer graphics, etc. The panorama image can be applied to various fields like virtual reality, robot vision areas which require wide-angled shots as an useful way to overcome the limitations such as picture-angle, resolutions, and internal informations of an image taken from a single camera. It is so much meaningful in a point that a panoramic image usually provides better immersion feeling than a plain image. Although there are many ways to build a panoramic image, most of them are using the way of extracting feature points and matching points of each images for making a single panoramic image. In addition, those methods use the RANSAC(RANdom SAmple Consensus) algorithm with matching points and the Homography matrix to transform the image. The SURF(Speeded Up Robust Features) algorithm which is used in this paper to extract featuring points uses an image's black and white informations and local spatial informations. The SURF is widely being used since it is very much robust at detecting image's size, view-point changes, and additionally, faster than the SIFT(Scale Invariant Features Transform) algorithm. The SURF has a shortcoming of making an error which results in decreasing the RANSAC algorithm's performance speed when extracting image's feature points. As a result, this may increase the CPU usage occupation rate. The error of detecting matching points may role as a critical reason for disqualifying panoramic image's accuracy and lucidity. In this paper, in order to minimize errors of extracting matching points, we used $3{\times}3$ region's RGB pixel values around the matching points' coordinates to perform intermediate filtering process for removing wrong matching points. We have also presented analysis and evaluation results relating to enhanced working speed for producing a panorama image, CPU usage rate, extracted matching points' decreasing rate and accuracy.