High Fidelity Calculation of Thermal Load in a Satellite Orbit (고정확도의 인공위성 궤도 열하중 계산 기법)

  • Kim, Min-Ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.10
    • /
    • pp.898-906
    • /
    • 2017
  • This paper discusses the efficient high fidelity calculation of external thermal loads of a spacecraft on its orbit. Thermal loads to a spacecraft consist of three major components, direct solar radiation, earth reflection of solar rays, and earth irradiation. With the assumption that both earth reflection and earth emission are diffuse, thermal loads from earth surface divided into pieces of segments to satellite surfaces are individually calculated and summed over. By using analytical integration of both reflected and emitted heat load by earth, high rate of numerical convergence is achieved and the results are even exactly calculated in special cases. Moreover, KD tree ray tracing is employed in the calculation of thermal load to determine whether the radiated ray is obstructed or not by satellite structure.

The Optimal Operation Pattern and Heat Pricing Scheme for District Heating CHP System (지역난방용 열병합발전시스템의 최적운전패턴과 적정 열요금구조)

  • 권영한;김창수;진병문;김진오
    • Journal of Energy Engineering
    • /
    • v.5 no.2
    • /
    • pp.183-192
    • /
    • 1996
  • This paper presents a numerical model of the optimal operation pattern of the CHP system built for duel-purpose of power generation and district heat production. The model can be differently formulated in accordance with the view of planner: society, electric utility or district-heating company. Here, the operation pattern of the system components and the effect of heat price are of major interest in the study. From the case study, it was found that the optimal use of auxiliary heating equipment is very important to achieve the minimum societal cost. And, the multi-step heat pricing scheme is desirable to induce the voluntary behavior of both companies towards the societal optimal pattern.

  • PDF

Analytical Study on the Performance of Ground Source Compound Hybrid Heat Pump System for Large Community Building (대형 Community 건물의 지열원 복합 하이브리드 히트펌프 시스템 성능에 관한 해석적 연구)

  • Byun, Jae-Ki;Jeong, Dong-Hwa;Lee, Jong-Gil;Hong, Seong-Ho;Choi, Young-Don;Cho, Sung-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.634-637
    • /
    • 2008
  • Ground source heat pumps are clean, energy-efficient and environment-friendly systems cooling and heating. Although the initial cost of ground source heat pump system is higher than that of air source heat pump, it is now widely accepted as an economical system since the installation cost can be returned within an short period of time due to its high efficiency. In the present study, performances of ground source compound hybrid heat pump system applied to a large community building are simulated. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a large community building. If among several renewable energy sources, ground, river, sea, waste water source are chosen as available alternative energies are combined, COP of the system can be increased largely and hybrid heat pump system can reduced the fuel cost.

  • PDF

Method for Measuring Weld Temperature Using an Infrared Thermal Imaging Camera (적외선 열화상 카메라를 이용한 용접부의 온도 측정 방법)

  • Ro, Chan-Seung;Kim, Kyeong-Suk;Chang, Ho-Seob
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.299-304
    • /
    • 2014
  • In this paper, a method is tested to measure temperatures in high-temperature welds. Protective glass was installed between an infrared thermal imaging camera and a heat source, and temperature compensation was applied to the measuring instruments. When the temperature of halogen lamps was taken in real-time and measured by the thermal camera, the temperature was found to be almost invariant with the distance between the camera and heat source. The temperature range could be predicted, through correlations with the thickness of the protective glass and the measured distance. This study suggests that the temperature measurement of welds obtained by using an infrared thermal imaging camera is valid, through experimental testing of heat sources.

A Study on the Application of Automobile Shredder Residue for Heat Source of Cement Manufacturing (자동차 폐차잔재(ASR)의 시멘트제조 열원활용을 위한 연구)

  • Oh, Sea-Cheon;Kwon, Woo-Teck;Kim, Soo-Ryong;Kim, Yong-Hee;Hong, John-Hee;Jin, Cheol-Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.709-712
    • /
    • 2007
  • 폐차잔재를 시멘트제조공정의 열원으로 활용하기 위해서는 연료로 사용하기 위한 경제성과 더불어 시멘트제조공정 및 품질 그리고 환경기준을 만족해야 한다. 따라서 폐차잔재의 최적투입방법과 폐차잔재의 연소시 염소물질의 거동특성에 대한 연구가 선행되어야만 한다. 본 연구에서는 이러한 폐차잔재의 시멘트 킬른 현장적용에 따른 위험요소와 시행착오를 최소화하기 위하여 최적 연료화 조건에 대한 전산모사 연구를 하였으며 전산모사의 대상공정으로는 폐차잔재가 투입될 Precalciner와 염소제어를 위하여 Bypass unit가 설치될 Precalciner의 하단부 그리고 Cyclone을 선정하여 입자 및 가스상의 거동 특성을 고찰하였다. 본 연구로부터 폐차잔재의 투입위치로는 현재의 석탄 투입위치를 활용하는 것이 효과적일 것으로 판단되었으며 Precalciner의 하단부에 대한 가스상 및 입자상의 거동특성을 활용하여 Bypass unit를 설치할 최적의 위치를 선정할 수 있었다. 또한 Cyclone의 입자 거동특성 결과로부터 염소 제어를 위한 각 Cyclone의 입자회수율에 대한 정보 및 공정의 개선 가능성을 확인할 수 있었다.

  • PDF

Natural Convection Heat Transfer in a Hemispherical Pool with Volumetric Heat Sources (체적 열원이 내재된 반구에서의 자연대류 열전달)

  • Park, Hae-Kyun;Chung, Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.24 no.3
    • /
    • pp.135-141
    • /
    • 2015
  • The core melts stratifies into lower mixture layer and upper metal layer by density in a severe accident condition. The decay heat generated from the mixture layer threatens the integrity of the reactor vessel. This study simulated the natural convection heat transfer of the mixture layer with volumetric heat source using the mass transfer system. $H_2SO_4-CuSO_4$ electroplating system was used as the mass transfer system. With the modified Rayleigh number of $3{\times}10^{14}$, the Nusselt number showed minimum at the bottom and increased along curvature to the top of the experimental apparatus.

Thermal Management on 3D Stacked IC (3차원 적층 반도체에서의 열관리)

  • Kim, Sungdong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.2
    • /
    • pp.5-9
    • /
    • 2015
  • Thermal management becomes serious in 3D stacked IC because of higher heat flux, increased power generation, extreme hot spot, etc. In this paper, we reviewed the recent developments of thermal management for 3D stacked IC which is a promising candidate to keep Moore's law continue. According to experimental and numerical simulation results, Cu TSV affected heat dissipation in a thin chip due to its high thermal conductivity and could be used as an efficient heat dissipation path. Other parameters like bumps, gap filling material also had effects on heat transfer between stacked ICs. Thermal aware circuit design was briefly discussed as well.

Cooling and Heating Operation Characteristics of Raw-water Source Heat Pump and Air Source Heat Pump in Water Treatment Facility (정수장 내 원수열원 및 공기열원 히트펌프의 냉난방 운전 특성)

  • Oh, Sun-Hee;Yun, Rin;Cho, Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.7
    • /
    • pp.386-391
    • /
    • 2013
  • The dynamic characteristics of both raw-water source and air source heat pump utilized in water treatment facilities were investigated by using TRNSYS simulator. The modeling of the raw water source heat pump was verified by the measured data at the Cheongju water treatment facility, and the modeling at the air source heat pump was verified by the data from the Siheung water treatment facility. The average heating and cooling COPs from the raw-water source heat pump were higher than those of the air source heat pump by 19% and 18%, respectively. The power consumptions of the air source heat pump for the cooling and the heating were higher than those of the raw water source heat pump by 28% and 26%, respectively.

The Effect of Heat Loss on the Radial Heat Flow in the Flash Method (반경방향 열흐름 섬광법에서 열손실의 영향)

  • 이홍주;김순규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.2
    • /
    • pp.257-264
    • /
    • 1989
  • For the extension of the flash method the heat diffusion equation with heat loss and with an arbitrary heat pulse is mathematically analyzed. In the analysis the heat loss includes the axial and radial directions on the front, rear and peripheral surfaces. The heat pulse is irradiated from the source to the front surface of the sample and the heat receiving area on the front surface is controlled by the apertures of an optical system. From this analysis the thermal diffusivity of the samples can be determined more precisely than before by the data reduction method using various percent time. The data can be obtained by the extended radial flash technique adjusted correctly the heating area on the central part of the front surface with a proper aperture or the conventional axial flash technique heated uniformly all parts of the front surface.

Operating characteristics of a heat pipe with two heat sources (두개의 열원이 부착된 히트파이프의 동작 특성)

  • Park, Jong-Heung;No, Hong-Gu;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.3
    • /
    • pp.303-315
    • /
    • 1998
  • Numerical and experimental studies on a heat pipe with two heat sources have been performed to investigate the operating characteristics. Numerical analysis was performed based on the cylindrical two-dimensional incompressible laminar flow for the vapor space and the conjugate heat transfer for the entire heat pipe. Experimental study with a 0.45 m length copper-water heat pipe was also performed to validate the numerical modeling for the heat input range from 29 W to 47 W on each heater. As results, the temperature profiles at the outer wall for the single active heat source as well as the temperature profiles for the switching operation between two heat sources are suggested. Due to the axial conduction, it is found that the temperature drop between the evaporator and the condenser appears small when the heat source closer to the condenser is turned on. For the switching operation in the present study, the transient time is about 700s and the temperatures at the locations of both heat source are same in 130s after switching.