• Title/Summary/Keyword: (5/3) transform

Search Result 758, Processing Time 0.033 seconds

Corroded and loosened bolt detection of steel bolted joints based on improved you only look once network and line segment detector

  • Youhao Ni;Jianxiao Mao;Hao Wang;Yuguang Fu;Zhuo Xi
    • Smart Structures and Systems
    • /
    • v.32 no.1
    • /
    • pp.23-35
    • /
    • 2023
  • Steel bolted joint is an important part of steel structure, and its damage directly affects the bearing capacity and durability of steel structure. Currently, the existing research mainly focuses on the identification of corroded bolts and corroded bolts respectively, and there are few studies on multiple states. A detection framework of corroded and loosened bolts is proposed in this study, and the innovations can be summarized as follows: (i) Vision Transformer (ViT) is introduced to replace the third and fourth C3 module of you-only-look-once version 5s (YOLOv5s) algorithm, which increases the attention weights of feature channels and the feature extraction capability. (ii) Three states of the steel bolts are considered, including corroded bolt, bolt missing and clean bolt. (iii) Line segment detector (LSD) is introduced for bolt rotation angle calculation, which realizes bolt looseness detection. The improved YOLOv5s model was validated on the dataset, and the mean average precision (mAP) was increased from 0.902 to 0.952. In terms of a lab-scale joint, the performance of the LSD algorithm and the Hough transform was compared from different perspective angles. The error value of bolt loosening angle of the LSD algorithm is controlled within 1.09%, less than 8.91% of the Hough transform. Furthermore, the proposed framework was applied to fullscale joints of a steel bridge in China. Synthetic images of loosened bolts were successfully identified and the multiple states were well detected. Therefore, the proposed framework can be alternative of monitoring steel bolted joints for management department.

Spectral Analysis of Heart Rate Variability during Treadmill Exercise at Various Speeds and Grades

  • Kim, Hyeong-Jin;Kim, Ki-Hong;Ahn, Dong-Kuk;Park, Jae-Sik
    • The Korean Journal of Physiology
    • /
    • v.30 no.1
    • /
    • pp.43-51
    • /
    • 1996
  • This study was aimed to elucidate the changes in heart rate variability during treadmill exercise at various speeds and grades by spectral analysis. Thirty-three untrained male college students aged $20{\sim}26\;yr $were employed to exercise on a treadmill using 4 speeds (4.02, 5.47, 6.76 and 8.05 km/h) and 6 grades (0, 4, 8, 12, 16 and 20%). A fixed speed was selected for each session with the grade increased every 3 min. The electrocardiogram, respiration and the stepping activity were continuously recorded through an A/D converter system on the computer disk. Power spectra of heart rate variability (RRV) were obtained by use of a fast Fourier transform algorithm. The frequency domain was divided into 3 bands: $VLF\;(0{\sim}0.04\;Hz),\;LF\;(0.04 {\sim}0.15\;Hz)\;and\;HF\;(0.15{\sim}1.00\;Hz).$ Heart rate was $74.4{\pm}2.1\;beats/min$ at rest and showed a steady increase during treadmill exercise with increasing speed and grade up to $196.7{\pm}5.0\;beats/min.$ Total power of HRV was $35.0{\pm}6.7\;(beats/min)^{2}$ at rest and progressively decreased during exercise down to $1.9{\pm}0.3\;(beats/min)^{2}.$ The %VLF power of HRV was $34.5{\pm}3.7\; %$ at rest and showed no significant change during exercise except for a decrease observed at the highest intensity of exercise. The %LF power was $44.1{\pm}3.0\;%$ at rest and showed a progressive decrease down to $4.5{\pm}1.0\;%$ during those stages of exercise where heart rate was over 135 beats/min. The %HF power was $21.4{\pm}2.9\;%$ at rest and showed a progressive increase up to $87.1{\pm}6.7\;%$ during higher intensity exercise where heart rate was over 165 beats/min. Peak frequency of HF band was $0.200{\pm}0.018\;Hz$ at rest and was shifted to higher frequencies up to $0.909{\pm}0.048\;Hz$ at heart rates greater than 135 beats/min. Respiratory frequency was $18.0{\pm}1.5$ breaths/min at rest and significantly increased during exercise up to $53.0{\pm}3.7$ breaths/min. Stride frequency during treadmill exercise showed an increasing tendency with increasing speed from $55.6{\pm}0.9$ steps/min at 4.02 km/h to $81.2{\pm}0.6$ at 8.05 km/h. It was concluded that total power of HRV decreased progressively with increasing exercise intensity due to the withdrawal of parasympathetic activity. At higher exercise intensity, % LF power decreased and %HF power increased with its peak frequency shifted to higher values in a progressive mode with increasing speed and grade, reflecting a readjustment in the cardiovascular system and the increased respiration and its rate, respectively.

  • PDF

Detection of Iron Nanoparticles using Nuclear Magnetic Resonance Relaxometry and Inverse Laplace Transform

  • Kim, Seong Min
    • Journal of Biosystems Engineering
    • /
    • v.39 no.4
    • /
    • pp.345-351
    • /
    • 2014
  • Purpose: Rapid detection of bacteria is very important in agricultural and food industries to prevent many foodborne illnesses. The objective of this study was to develop a portable nuclear magnetic resonance (NMR)-based system to detect foodborne pathogens (E. coli). This study was focused on developing a method to detect low concentrations of magnetic nanoparticles using NMR techniques. Methods: NMR relaxometry was performed to examine the NMR properties of iron nanoparticle mixtures with different concentrations by using a 1 T permanent magnet magnetic resonance imaging system. Exponential curve fitting (ECF) and inverse Laplace transform (ILT) methods were used to estimate the NMR relaxation time constants, $T_1$ and $T_2$, of guar gum solutions with different iron nanoparticle concentrations (0, $10^{-3}$, $10^{-4}$, $10^{-5}$, $10^{-6}$, and $10^{-7}M$). Results: The ECF and ILT methods did not show much difference in these values. Analysis of the NMR relaxation data showed that the ILT method is comparable to the classical ECF method and is more sensitive to the presence of iron nanoparticles. This study also showed that the spin-spin relaxation time constants acquired by a Carr-Purcell-Meiboom-Gill (CPMG) pulse sequence are more useful for determining the concentration of iron nanoparticle solutions comparwith the spin-lattice relaxation time constants acquired by an inversion recovery pulse sequence. Conclusions: We conclude that NMR relaxometry that utilizes CPMG pulse sequence and ILT analysis is more suitable for detecting foodborne pathogens bound to magnetic nanoparticles in agricultural and food products than using inversion recovery pulse sequence and ECF analysis.

A Video Watermarking Based on Wavelet Transform Using Spread Spectrum Technique (대역확산방법을 이용한 웨이블릿 기반의 비디오 워터마킹)

  • Kim, Seung-Jin;Kim, Tae-Su;Lee, Kuhn-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.5 s.305
    • /
    • pp.11-18
    • /
    • 2005
  • In this paper, we proposed a video watermarking algerian based on wavelet transform using statistical characteristic of video according to the energy distribution and the spread spectrum technique. In the proposed method, the original video is splitted by spatial difference metric and classified into the motion region and the motionless region according to the motion degree. The motion region is decomposed into 3-levels using 3D DWT and the motionless region is decomposed into 2-levels using 2D DWT The baseband of the wavelet-decomposed image is not utilized because of the image quality. So that the standard deviation of the highest subband coefficients except for the baseband is used to determine the threshold. Binary video watermarks preprocessed by the random permutation and the spread spectrum technique are embedded into selected coefficients. In computer experiments, the proposed algorithm was found to be more invisible and robust than the conventional algorithms.

Improvement of SPIHT-based Document Encoding and Decoding System (SPIHT 기반 문서 부호화와 복호화 시스템의 성능 향상)

  • Jang, Joon;Lee, Ho-Suk
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.7_8
    • /
    • pp.687-695
    • /
    • 2003
  • In this paper, we present a document image compression system based on segmentation, Quincunx downsampling, (5/3) wavelet lifting and subband-oriented SPIHT coding. We reduced the coding time by the adaptation of subband-oriented SPIHT coding and Quincunx downsampling. And to increase compression rate further, we applied arithmetic coding to the bitstream of SPIHT coding output. Finally, we present the reconstructed images for visual comparison and also present the compression rates and PSNR values under various scalar quantization methods.

Implementation of 3D Moving Target-Tracking System based on MSE and BPEJTC Algorithms

  • Ko, Jung-Hwan;Lee, Maeng-Ho;Kim, Eun-Soo
    • Journal of Information Display
    • /
    • v.5 no.1
    • /
    • pp.41-46
    • /
    • 2004
  • In this paper, a new stereo 3D moving-target tracking system using the MSE (mean square error) and BPEJTC (binary phase extraction joint transform correlator) algorithms is proposed. A moving target is extracted from the sequential input stereo image by applying a region-based MSE algorithm following which, the location coordinates of a moving target in each frame are obtained through correlation between the extracted target image and the input stereo image by using the BPEJTC algorithm. Through several experiments performed with 20 frames of the stereo image pair with $640{\times}480$ pixels, we confirmed that the proposed system is capable of tracking a moving target at a relatively low error ratio of 1.29 % on average at real time.

Gas Transport Properties of Crosslinked Polyimide Membranes Induced by Aliphatic Diamines with Different Chain Length (사슬 길이가 다른 지방족 디아민으로 가교된 폴리이미드 분리막의 기체 투과 특성)

  • Lee, Hye Rim;Lee, Jung Moo;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.23 no.6
    • /
    • pp.450-459
    • /
    • 2013
  • 2,3,5,6-Tetramethyl-1,4-phenylenediamine (TMPD) based polyimide (PI) were crosslinked with 1,2-Diaminoethane (DAE) and 1,6-Diaminohexane (DAH) to enhance gas transport properties. Fourier transform infrared (FT-IR) studies show that imide groups were converted into amide groups during crosslinking process. Thermogravimetric analysis (TGA) results indicate that the degradation temperature of crosslinked PI membranes decreased after crosslinking. This is due to degradation of alkyl group in crosslinking agent. The d-space of crosslinked PI membranes decreased with increasing crosslinking time. The ideal permeability for $CH_4$, $N_2$, $O_2$, and $CO_2$ decreased after crosslinking and the ideal permeability of crosslinked PI membranes induced by DAH is larger than that by DAE. In contrast, the permselectivity of $CO_2/CH_4$, $CO_2/N_2$ and $O_2/N_2$ increased during crosslinking. For the gas pair of $CO_2/CH_4$, the maximum increment is about 39.5% after 6 minutes of DAE crosslinking. Also, that of $O_2/N_2$ gas pair is about 20.5% after 6 minutes of DAE crosslinking. According to these result, DAE is more suitable for enhanced permselectivity than DAH. On the contrary, DAE is not useful for $CO_2/N_2$ separation due to reduction in $CO_2/N_2$ permselectivity after 3 minutes DAE crosslinking.

Design of 3D Laser Radar Based on Laser Triangulation

  • Yang, Yang;Zhang, Yuchen;Wang, Yuehai;Liu, Danian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.5
    • /
    • pp.2414-2433
    • /
    • 2019
  • The aim of this paper is to design a 3D laser radar prototype based on laser triangulation. The mathematical model of distance sensitivity is deduced; a pixel-distance conversion formula is discussed and used to complete 3D scanning. The center position extraction algorithm of the spot is proposed, and the error of the linear laser, camera distortion and installation are corrected by using the proposed weighted average algorithm. Finally, the three-dimensional analytic computational algorithm is given to transform the measured distance into point cloud data. The experimental results show that this 3D laser radar can accomplish the 3D object scanning and the environment 3D reconstruction task. In addition, the experiment result proves that the product of the camera focal length and the baseline length is the key factor to influence measurement accuracy.

Multiscale Regularization Method for Image Restoration (다중척도 정칙화 방법을 이용한 영상복원)

  • 이남용
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.5 no.3
    • /
    • pp.173-180
    • /
    • 2004
  • In this paper we provide a new image restoration method based on the multiscale regularization in the redundant wavelet transform domain. The proposed method uses the redundant wavelet transform to decompose the single-scale image restoration problem to multiscale ones and applies scale dependent regularization to the decomposed restoration problems. The proposed method recovers sharp edges by applying rather less regularization to wavelet related restorations, while suppressing the resulting noise magnification by the wavelet shrinkage algorithm. The improved performance of the proposed method over more traditional Wiener filtering is shown through numerical experiments.

  • PDF

Construction and Measurement of Normal Spectral Emissivity Device using Fourier Transform Infrared Spectrometer (퓨리에 변환 적외선 분광기를 이용한 수직 분광 복사율 측정 장치의 제작과 측정)

  • Jeon, Sang-Ho;Yoo, Nam-Joon;Jo, Jae-Heung;Park, Chul-Woung;Park, Seung-Nam;Lee, Geun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.6
    • /
    • pp.400-407
    • /
    • 2008
  • An Instrument to measure normal spectral emissivity is built using a Fourier Transform-Infrared (FT-IR) spectrometer. The instrument is composed of four main parts, reference blackbody, sample furnace, optics system, and FT-IR spectrometer. Measurement ranges of temperature and wavelength are $200^{\circ}C{\sim}500^{\circ}C$ and $3.5{\mu}m{\sim}20{\mu}m$, respectively. Measured emissivity of the reference blackbody is greater than 0.9993 with combined relative uncertainty less than 0.69%, which can be considered an ideal blackbody. We studied the emissivity of opaque alumina, graphite, anodized aluminum, and steel (IMS 200). It is shown that emissivity increases with the roughness of the steel (IMS 200) surface.