• 제목/요약/키워드: ((0,1)-행렬

검색결과 186건 처리시간 0.023초

TRMM TMI를 이용한 해상풍 추정에 관한 연구 (The Study on the Oceanic Surface Wind Retrieval using TRMM Microwave Imager)

  • 김영섭;홍기만
    • 한국지리정보학회지
    • /
    • 제5권2호
    • /
    • pp.47-53
    • /
    • 2002
  • 본 연구에서는 열대강우관측 위성(TRMM) 자료를 이용하여 해상풍을 예측하였고, TRMM TMI 휘도 온도와 북미 주변의 NDBC (National Data Buoy Centers) 부이 자료를 이용하여 해상풍을 추정하였다. 이 결과는 행렬방정식에 의한 부이와 비교하였는데 RMSE, BIAS 그리고 상관계수는 각각 2.19 $ms^{-1}$, 1.10 $ms^{-1}$, 그리고 0.81로 나타났으며, 이 결과는 앞으로 TRMM TMI를 이용한 해양 연구에 가능성을 보여주었다.

  • PDF

GI/M/1/K 대기행렬의 이탈시점 기준 잔여도착간격 분석 (On the Remaining Interarrival Time upon Reaching a Given Level in the GI/M/1/K Queue)

  • 채경철;서가이
    • 대한산업공학회지
    • /
    • 제32권4호
    • /
    • pp.369-372
    • /
    • 2006
  • Suppose that a customer arrives at the GI/M/1/K queueing system when there are customers in the system, $n,m{\geq}0,\;n+m{\leq}K$. Sooner or later, the number of customers in the system will reach . In this paper, we present the Laplace transform of the remaining interarrival time upon reaching level, for the first time, since a customer arrived when there are customers in the system.

상태궤환을 이용한 2차원 시스템의 극배치

  • 이원규;이상혁
    • 한국통신학회논문지
    • /
    • 제15권8호
    • /
    • pp.659-666
    • /
    • 1990
  • 최근에 이산치 2차원 시스템을 기술하는 여러가지 상태공간모델이 제안되어 왔다. 본 논문에서는 Roesser가 제안한 상태공간모델을 근거로 상태궤환을 이용하여 2차원 시스템의 극배치 문제를 고찰한다. 극배치 설계는 2단계로 나누어 1단계에서는 변환된 시스템의 비대각 행렬(off diagonal matrix)을 0으로 하는 조건을 유도하고 2단계에서는 2차원 시스템의 극배치 문제가 2개의 1차원 시스템의 극배치 문제도 된다는 것을 보여준다. 마지막으로 극배치 기법을 설명하기 위한 예를 들었다.

  • PDF

SNU 1.5-MV 직렬형 반데그라프 가속기의 $He^{++}$ 빔 소송계에 대한 이온광학적 고찰 (Ion Optical Study on the $He^{++}$ Beam Transport System of the SNU 1.5-MV Tandem Van do Graaff Accelerator)

  • Hyen-Cheol JO;Young-Dug BAE;Hae-iLL BAK
    • Nuclear Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.426-437
    • /
    • 1991
  • SNU 1.5-MV 직렬형 반데그라프 가속기의 $He^{++}$ 빔 수송계를 이온광학적으로 분석하였다. 각 이온광학요소의 최적운전조건을 결정하고, 이온빔 수송을 모사하기 위하여 프로그램 OPTRANS를 개발하였다. 일차행렬법을 사용하였으며, 공간전하효과는 무시하였다. 프로그램 OPTRANS를 사용하여 0.5~3.0 MeV $He^{++}$ 빔 수송을 위한 최적운전조건을 결정하였다. 초기 이온빔의 방사면량은 인출전극의 구조와 이온빔 인출실험에 의해 0.5$\times$80.0 mm.mrad으로 가정하였다. 운전조건의 변화에 따른 각 이온광학요소의 이온빔 수송 특성을 검토하였으며, 각 Slit과 Stripping Foil, 그리고 표적에서 빔 크기가 최소로 되도록 하는 운전조건을 계산하였다. 이온빔 수송 실험으로부터 얻어진 최적운전조건은 계산된 값과 오차 범위 15% 내에서 일치하였다. 이온빔 수송 모사와 실험을 통해, 계산된 최적운전조건의 타당성 및 프로그램 OPTRANS의 유용성을 입증하였다.

  • PDF

혼합모형을 이용한 체지방 반복측정자료에 대한 통계적 분석 (A statistical analysis of the fat mass repeated measures data using mixed model)

  • 조진남;장은재
    • Journal of the Korean Data and Information Science Society
    • /
    • 제24권2호
    • /
    • pp.303-310
    • /
    • 2013
  • 체지방 감량에 대한 효과를 분석하고자 실험에 참가한 체지방율이 30% 이상인 42명의 여대생을 대상으로 일반폰을 사용하는 그룹과 스마트폰을 사용하는 그룹으로 나누어서 측정자료를 2주 간격으로 정리하여 8주간에 걸친 체지방 및 관련자료를 얻었다. 이 실험자료를 바탕으로 혼합모형을 이용하여 분석한 결과 AR(1)의 공분산행렬이 가장 적합한 모형으로 선택되었으며, 시점 간의 상관계수는 0.838로 상당히 밀접한 관련을 보여주었다. AR(1)의 공분산행렬을 설정하여 분석한 결과 처리간의 차이에서 스마트폰의 사용자가 일반폰의 사용자보다 0.654kg 정도의 체지방 감량 효과를 보여주었으며, 시간이 지날수록 체지방 감소효과가 있음을 알 수 있다. 그러나 처리와 시간과의 교호작용은 존재하지 않는다. 또한 실험실시 전의 체지방값과 총콜레스테롤은 유의하게 나타났으며, 섭취하는 칼로리는 약간 관련이 있으나, 허리엉덩이비율은 유의하지 않는 것으로 판명되었다.

제조 현장의 비정상 데이터 분류를 위한 기계학습 기반 접근 방안 연구 (Machine Learning based on Approach for Classification of Abnormal Data in Shop-floor)

  • 신현준;오창헌
    • 한국정보통신학회논문지
    • /
    • 제21권11호
    • /
    • pp.2037-2042
    • /
    • 2017
  • 스마트 공장은 미리 입력된 프로그램에 의해 생산시설이 수동적으로 움직이는 공장 자동화 작업 방식과는 달리, 생산 설비 스스로 작업 방식을 결정하여야 한다. 생산 설비 스스로 작업 방식을 결정이라 함은, 이를테면 제조 현장에서 설비의 노후, 문제 발생 예측, 제품의 불량 검출 등과 같은 이상 징후가 발생할 시 이를 조기에 발견한 후 스스로 문제를 해결하는 것을 의미한다. 본 논문에서는 제조 현장의 제조 공정 이상 징후 감지를 위해 대기행렬을 이용한 제조 공정 모델링을 제시하고 해당 모델링에서 이상 징후를 기계학습 기술 중 하나인 SVM을 이용하여 이를 감지하도록 한다. 해당 대기행렬을 M/D/1을 사용하였으며, ${\mu}$, ${\lambda}$, ${\rho}$를 기반으로 컨베이어 벨트 제조 시스템을 모델링하였다. SVM을 이용하여 ${\rho}$의 변화량을 통해 이상 징후를 감지했다.

판정행렬을 기반한 일체형 PET-MRI의 폐암 진단 유용성 평가 (Evaluation of Usefulness for Diagnosis of Lung Cancer on Integrated PET-MRI Using Decision Matrix)

  • 김정수;양현진;김유미;권형진;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.635-643
    • /
    • 2021
  • The results of empirical researches on the diagnosis of lung cancer are insufficient, so it is limited to objectively judge the clinical possibility and utilization according to the accuracy of diagnosis. Thus, this study retrospectively analyzed the lung cancer diagnostic performance of PET-MRI (Positron Emission Tomography-Magnetic Resonance Imaging) by using the decision matrix. This study selected and experimented total 165 patients who received both hematological CEA (Carcinoembryonic Antigen) test and hybrid PET-MRI (18F-FDG, 5.18 MBq/kg / Body TIM coil. VIVE-Dixon). After setting up the result of CEA (positive:>4 ㎍/ℓ. negative:<2.5㎍/ℓ) as golden data, the lung cancer was found in the image of PET-MRI, and then the SUVmax (positive:>4, negative:<1.5) was measured, and then evaluated the correlation and significance of results of relative diagnostic performance of PET-MRI compared to CEA through the statistical verification (t-test, P>0.05). Through this, the PET-MRI was analyzed as 96.29% of sensitivity, 95.23% of specificity, 3.70% of false negative rate, 4.76% of false positive rate, and 95.75% of accuracy. The false negative rate was 1.06% lower than the false positive rate. The PET-MRI that significant accuracy of diagnosis through high sensitivity and specificity, and low false negative rate and false positive rate of lung cancer, could acquire the fusion image of specialized soft tissue by combining the radio-pharmaceuticals with various sequences, so its clinical value and usefulness are regarded as latently sufficient.

반복측정자료 분석을 위한 혼합모형의 적용성 검토: 강원지역 굴참나무 임분을 대상으로 (Applicability Evaluation of a Mixed Model for the Analysis of Repeated Inventory Data : A Case Study on Quercus variabilis Stands in Gangwon Region)

  • 표정기;이상태;서경원;이경재
    • 한국산림과학회지
    • /
    • 제104권1호
    • /
    • pp.111-116
    • /
    • 2015
  • 본 연구의 목적은 임의효과(random effect)를 포함하는 혼합모형(mixed model)을 이용하여 흉고직경과 수고의 변화량을 평가하는데 있다. 강원도 굴참나무 임분을 대상으로 흉고직경과 수고를 조사하고 3년 후 동일 임분을 재조사하였다. 혼합모형에서 굴참나무의 흉고직경-수고 관계는 고정효과(fixed effect)이고 초기측정과 반복측정의 흉고직경과 수고 차이를 임의효과로 설정하였다. 임의효과에 따른 모형의 적합도를 검정하기 위하여 아카이케의 정보기준(akaike information criterion, AIC)을 참고하고 반복 측정에 따른 분산-공분산 행렬과 오차항을 산정하였다. 추정된 공분산은 -0.0291이고 오차항은 0.1007을 나타내었다. 분산-공분산 행렬을 이용한 임의효과가 포함된 모형의 AIC(=-215.5)는 고정효과를 고려한 모형의 AIC(=-154.4)에 비해 낮은 수치를 나타내었다. 이러한 결과는 범주형 자료의 임의효과가 모형 개발에 반영되는 결과인 것으로 조사되었다. 그러므로, 본 연구에서 적용된 혼합모형은 반복 측정 자료를 이용한 모형 개발에 활용이 가능한 것으로 판단된다.

랜덤 치환 고속 발생기 설계 및 응용 (A pseudo Random Permutation Generator with application to random bit genefator)

  • 고승철;이대기
    • 정보보호학회지
    • /
    • 제3권1호
    • /
    • pp.26-30
    • /
    • 1993
  • 본 논문에서는Akl-Meijer가 설계한 랜덤 치환 발생기를 일반화한 알고리즘을 제안한다. Akl과 Meijer는 사이즈가 m인 치환(Permutation)과 0과 m!-1사이의 정수를 일대일 대응시키는 Knuth의 알고리즘을 이용하여, 선형 합동법 Y=X+C mod m! (C는 상수)에서 발생되는 난수와 일대일 대응되는 치환을 발생하는 치환 발생 알고리즘을 설계하였으며, 이를 응용하여, 이진 난수 발생기를 제시하였다. 본 논문에서는 선형 합동법 Y=AX+C mod m!(A, C는 상수)에서 발생되는 난수와 일대일 대응되는 치환 계산과정을 상삼각 행렬(Upper triangular matrix) 의 곱으로 변환하여 고속으로 계산하는 알고리즘을 제시한후, 이 알고리즘의 출력 치환을 n 개 결합하여 치환을 발생하는 랜덤치환 발생기를 설계한다. 또한 이의 암호적인 응용으로, 치환 발생기를 이용한 이진 난수 발생기를 제시한다.

  • PDF

소아의 경직장 영상을 위한 two-turn 표면형 코일과 안장 코일의 비교

  • 김은주;김민정;김대홍;서진석;김명준;김동익;정은기
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.146-146
    • /
    • 2001
  • 목적: 해상도가 우수한 경직장 영상을 위한 소아용 two-turn 표면형 수신 코일, 안장 수신 코일을 제작하여 이를 이용하여 얻은 고양이의 경직장 영상을 비교한다. 대상 및 방법: 지금까지 소아의 경직장 영상은 주로 초음파를 이용하여 얻었으나 해상도가 떨어지며 아직까지 소아용 탐촉자는 개발되지 않았다. 소아의 항문직장 기형의 진단을 위해서는 해상도가 우수한 영상이 필요하고, 이를 위해 소아용 직장 RF 코일로 원주형 two-turn 표면형 코일, 안장 코일을 제작하였다. 크기는 직경 7mm, 길이 6cm와, 직경 10mm, 길이 l0cm 하였고, 코일의 구리선 바깥으로는 두께 1mm의 테프론 tube로 감쌌다. 균일한 시험 시료(phantom)로 마요네즈를 이용하여 T1 강조 영상(Spin echo TR/TE= 500/11 msec, FOV=12cm, 영상행렬 256$\times$256)을 얻어서 신호 강도의 profile을 얻는다. 이를 Mathematica를 이용하여 구한 RF 자기장 세기의 분포와 비교했다. 두 종류의 코일을 각각 사용하여 얻은 고양이 항문 괄약근 영상에서 외부 괄약근, 내부 괄약근 등을 구분, 비교하였다.

  • PDF