• Title/Summary/Keyword: '-고'

Search Result 45,380, Processing Time 0.075 seconds

A Consideration of Apron's Shielding in Nuclear Medicine Working Environment (PET검사 작업환경에 있어서 APRON의 방어에 대한 고찰)

  • Lee, Seong-wook;Kim, Seung-hyun;Ji, Bong-geun;Lee, Dong-wook;Kim, Jeong-soo;Kim, Gyeong-mok;Jang, Young-do;Bang, Chan-seok;Baek, Jong-hoon;Lee, In-soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.110-114
    • /
    • 2014
  • Purpose: The advancement in PET/CT test devices has decreased the test time and popularized the test, and PET/CT tests have continuously increased. However, this increases the exposure dose of radiation workers, too. This study aims to measure the radiation shielding rate of $^{18}F-FDG$ with a strong energy and the shielding effect when worker wore an apron during the PET/CT test. Also, this study compared the shielding rate with $^{99m}TC$ to minimize the exposure dose of radiation workers. Materials and Methods: This study targeted 10 patients who visited in this hospital for the PET/CT test for 8 days from May 2nd to 10th 2013, and the $^{18}F-FDG$ distribution room, patient relaxing room (stand by room after $^{18}F-FDG$ injection) and PET/CT test room were chosen as measuring spots. Then, the changes in the dose rate were measured before and after the application of the APRON. For an accurate measurement, the distance from patients or sources was fixed at 1M. Also, the same method applied to $^{99m}TC's$ Source in order to compare the reduction in the dose by the Apron. Results: 1) When there was only L-block in the $^{18}F-FDG$ distribution room, the average dose rate was $0.32{\mu}Sv$, and in the case of L-blockK+ apron, it was $0.23{\mu}Sv$. The differences in the dose and dose rate between the two cases were respectively, $0.09{\mu}Sv$ and 26%. 2) When there was no apron in the relaxing room, the average dose rate was $33.1{\mu}Sv$, and when there was an apron, it was $22.3{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $10.8{\mu}Sv$ and 33%. 3) When there was no APRON in the PET/CT room, the average dose rate was $6.9{\mu}Sv$, and there was an APRON, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $1.4{\mu}Sv$ and 25%. 4) When there was no apron, the average dose rate of $^{99m}TC$ was $23.7{\mu}Sv$, and when there was an apron, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $18.2{\mu}Sv$ and 77%. Conclusion: According to the result of the experiment, $^{99m}TC$ injected into patients showed an average shielding rate of 77%, and $^{18F}FDG$ showed a relatively low shielding rate of 27%. When comparing the sources only, $^{18F}FDG$ showed a shielding rate of 17%, and $^{99m}TC$'s was 77%. Though it had a lower shielding effect than $^{99m}TC$, $^{18}F-FDG$ also had a shielding effect on the apron. Therefore, it is considered that wearing an apron appropriate for high energy like $^{18}F-FDG$ would minimize the exposure dose of radiation workers.

  • PDF

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF

Summer-Time Behaviour and Flux of Suspended Sediments at the Entrance to Semi-Closed Hampyung Bay, Southwestern Coast of Korea (만 입구에서 부유퇴적물 거동과 플럭스: 한반도 서해 남부 함평만의 여름철 특성)

  • Lee, Hee-Jun;Park, Eun-Sun;Lee, Yeon-Gyu;Jeong, Kap-Sik;Chu, Yong-Shik
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.5 no.2
    • /
    • pp.105-118
    • /
    • 2000
  • Anchored measurements (12.5 hr) of suspended sediment concentration and other hydrodynamic parameters were carried out at two stations located at the entrance to Hampyung Bay in summer (August 1999). Tidal variations in water temperature and salinity were in the range of 26.0-27.9$^{\circ}C$ and 30.9-31.5, respectively, indicating exchange offshore and offshore water mass. Active tidal mixing processes at the entrance appear to destroy the otherwise vertical stratification in temperature and salinity in spite of strong solar heating in summer. On the contrary, suspended sediment concentrations show a marked stratification with increasing concentrations toward bottom layer. Clastic particles in suspended sediments consist mostly of very fine to fine silt (4-16 ${\mu}$m) with a poorly-sorted value of 14.7-25.9 ${\mu}$m. However, at slack time with less turbulent energy, flocs larger than 40 ${\mu}$m are formed by cohesion and inter-collision of particles, resulting in a higher settling velocity. Strong ebb-dominated and weak flood dominated tidal currents, in the southwestern and the northeastern part, respectively, result in a seaward residual flow of -10${\sim}$-20 cm $s^{-1}$ at station H1 and a bayward residual flow less than 5.0 cm $s^{-1}$ at station H2. However, mean concentration of suspended sediments at station H1 is higher at flood (95.0-144.1 mg $1^{-1}$) than in ebb (75.8-120.9 mg $1^{-1}$). On the contrary, at the station H2, the trend is reversed with higher concentration at the ebb (84.7-158.4 mg $1^{-1}$) than that at the flood (53.0-107.9 mg $1^{-1}$). As a result, seaward net suspended sediment fluxes ($f_{s}$) are calculated to be -1.7 ${\sim}$-$15.610^{3}$ kg $m^{-2}$ $s^{-1}$ through the whole water column. However, the stations H1 and H2 show definitely different values of the flux with higher ones in the former than in the latter. Alternatively, depth-integrated net suspended sediment loads ($\c{Q}_{s}$) for one tidal cycle are also toward the offshore with ranges of 0.37${\times}$$10^{3}$ kg $m^{-1}$ and 0.21${\times}$$10^{3}$ kg $m^{-1}$, at station H1 and H2, respectively. This seaward transport of suspended sediment in summer suggests that summer-time erosion in the Hampyung muddy tidal flats is a rather exceptional phenomenon compared to the general deposition reported for many other tidal flats on the west coast of Korea.

  • PDF

The Clinical Application and Results of Palliative Damus-Kaye-Stansel Procedure (고식적 Damus-Kaye-Stansel 술식의 임상적 적용 및 결과)

  • Lim, Hong-Gook;Kim, Soo-Jin;Kim, Woong-Han;Hwang, Seong-Wook;Lee, Cheul;Shinn, Sung-Ho;Yie, Kil-Soo;Lee, Jae-Woong;Lee, Chang-Ha
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • Background: The Damus-Kaye-Stansel (DKS) procedure is a proximal MPA-ascending aorta anastomosis used to relieve systemic ventricular outflow tract obstructions (SVOTO) and pulmonary hypertension. The purpose of this study was to review the indications and outcomes of the DKS procedure, including the DKS pathway and semilunar valve function. Material and Method: A retrospective review of 28 patients who underwent a DKS procedure between May 1994 and April 2006 was performed. The median age at operation was 5.3 months ($13\;days{\sim}38.1\;months$) and body weight was 5.0 kg ($2.9{\sim}13.5\;kg$). Preoperative pressure gradients were $25.3{\pm}15.7\;mmHg$ ($10{\sim}60\;mmHg$). Eighteen patients underwent a preliminary pulmonary artery banding as an initial palliation. Preoperative main diagnoses were double outlet right ventricle in 9 patients, double inlet left ventricle with ventriculoarterial discordance in 6,. another functional univentricular heart in 5, Criss-cross heart in 4, complete atrioventricular septal defect in 3, and hypoplastic left heart variant in 1. DKS techniques included end-to-side anastomosis with patch augmentation in 14 patients, classical end-to-side anastomosis in 6, Lamberti method (double-barrel) in 3, and others in 5. The bidirectional cavopulmonary shunt and Fontan procedure were concomitantly performed in 6 and 2 patients, respectively. Result: There were 4 hospital deaths (14.3%), and 3 late deaths (12.5%) with a follow-up duration of $62.7{\pm}38.9$ months ($3.3{\sim}128.1$ months). Kaplan-Meier estimated actuarial survival was $71.9%{\pm}9.3%$ at 10 years. Multivariate analysis showed right ventricle type single ventricle (hazard ratio=13.960, p=0.004) and the DKS procedure as initial operation (hazard ratio=6.767, p=0.042) as significant mortality risk factors. Four patients underwent staged biventricular repair and 13 received Fontan completion. No SVOTO was detected after the procedure by either cardiac catheterization or echocardiography except in one patient. There was no semiulnar valve regurgitation (>Gr II) or semilunar valve-related reoperation, but one patient (3.6%) who underwent classical end-to-side anastomosis needed reoperation for pulmonary artery stenosis caused by compression of the enlarged DKS pathway. The freedom from reoperation for the DKS pathway and semilunar valve was 87.5% at 10 years after operation. Conclusion: The DKS procedure can improve the management of SVOTO, and facilitate the selected patients who are high risk for biventricular repair just after birth to undergo successful staged biventricular repair. Preliminary pulmonary artery banding is a safe and effective procedure that improves the likelihood of successful DKS by decreasing pulmonary vascular resistance. The long-term outcome of the DKS procedure for semilunar valve function, DKS pathway, and relief of SVOTO is satisfactory.

Clinical Outcomes of Off-pump Coronary Artery Bypass Grafting (심폐바이패스 없는 관상동맥우회술의 임상성적)

  • Shin, Je-Kyoun;Kim, Jeong-Won;Jung, Jong-Pil;Park, Chang-Ryul;Park, Soon-Eun
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.34-40
    • /
    • 2008
  • Background: Off-pump coronary artery bypass grafting (OPCAB) shows fewer side effects than cardiopulmonary by. pass, and other benefits include myocardial protection, pulmonary and renal protection, coagulation, inflammation, and cognitive function. We analyzed the clinical results of our cases of OPCAB. Material and Method: From May 1999 to August 2007, OPCAB was performed in 100 patients out of a total of 310 coronary artery bypass surgeries. There were 63 males and 37 females, from 29 to 82 years old, with a mean age of $62{\pm}10$ years. The preoperative diagnoses were unstable angina in 77 cases, stable angina in 16, and acute myocardial infarction in 7. The associated diseases were hypertension in 48 cases, diabetes in 42, chronic renal failure in 10, carotid artery disease in 6, and chronic obstructive pulmonary disease in 5. The preoperative cardiac ejection fraction ranged from 26% to 74% (mean $56.7{\pm}11.6%$). Preoperative angiograms showed three-vessel disease in 47 cases, two-vessel disease in 25, one-vessel disease in 24, and left main disease in 23. The internal thoracic artery was harvested by the pedicled technique through a median sternotomy in 97 cases. The radial artery and greater saphenous vein were harvested in 70 and 45 cases, respectively (endoscopic harvest in 53 and 41 cases, respectively). Result: The mean number of grafts was $2.7{\pm}1.2$ per patient, with grafts sourced from the unilateral internal thoracic artery in 95 (95%) cases, the radial artery in 62, the greater saphenous vein in 39, and the bilateral internal thoracic artery in 2. Sequential anastomoses were performed in 46 cases. The anastomosed vessels were the left anterior descending artery in 97 cases, the obtuse marginal branch in 63, the diagonal branch in 53, the right coronary artery in 30, the intermediate branch in 11, the posterior descending artery in 9 and the posterior lateral branch in 3. The conversion to cardiopulmonary bypass occurred in 4 cases. Graft patency was checked before discharge by coronary angiography or multi-slice coronary CT angiography in 72 cases, with a patency rate of 92.9% (184/198). There was one case of mortality due to sepsis. Postoperative arrhythmias or myocardial in-farctions were not observed. Postoperative complications were a cerebral stroke in 1 case and wound infection in 1. The mean time of respirator care was $20{\pm}35$ hours and the mean duration of stay in the intensive care unit was $68{\pm}47$ hours. The mean amounts of blood transfusion were $4.0{\pm}2.6$ packs/patient. Conclusion: We found good clinical outcomes after OPCAB, and suggest that OPCAB could be used to expand the use of coronary artery bypass grafting.

Hydrochemical and Isotopic Characteristics, and Origin of Noble Gas for Low-temperature Hot Spring Waters in the Honam Area (호남지역 저온형 온천수의 수리지화학적 및 안정동위원소 특성과 영족기체의 기원에 관한 연구)

  • Jeong, Chan-Ho;Hur, Hyun-Sung;Nagao, Keisuke;Kim, Kyu-Han
    • Economic and Environmental Geology
    • /
    • v.40 no.5
    • /
    • pp.635-649
    • /
    • 2007
  • Geochemical composition, stable isotopes $({\delta}^{18}O,\;{\delta}D,\;{\delta}^{34}S)$ and noble gases(He, Ne and Ar) of nine hot spring water and three groundwater for five hot springs(Jukam, Hwasun, Dokog, Jirisan, Beunsan) from the Honam area were analyzed to investigate the hydrogeochemical characteristics and the hydrogeochemical evolution of the hot spring waters, and to interpret the source of sulfur, helium and argon dissolved in the hot spring waters. The hot spring waters show low water temperature ranging from 23.0 to $30.5^{\circ}C$ and alkaline characteristics of pH 7.67 to 9.98. Electrical conductivity of hot spring waters is $153{\sim}746{\mu}S/cm$. Groundwaters in this area were characterized by the acidic to neutral pH range$(5.85{\sim}7.21)$, the wide electrical conductivity range $(44{\sim}165{\mu}S/cm)$. The geochemical compositions of hot spring and groundwaters can be divided into three water types: (1) $Na-HCO_3$ water type, (2) Na-Cl water type and (3) $Ca-HCO_3$ water type. The hot spring water of $Ca-HCO_3$ water type in early stage have been evolved through $Ca(Na)-HCO_3$ water type into $Na-HCO_3$ type in final stage. In particular, Jurim alkaline(pH 9.98) hot spring water plotted at the end point of $Na-HCO_3$ type in the Piper diagram is likely to arrive into the final stage in geochemical evolution process. Hydrogen and oxygen isotopic data of the hot spring water samples indicate that the hot spring waters originated from the local meteoric water showing latitude and altitude effects. The ${\delta}^{34}S$ value for sulfate of the hot spring waters varies widely from 0.5 to $25.9%o$. The sulfur source of most hot spring waters in this area is igneous origin. However, The ${\delta}^{34}S$ also indicates the sulfur of JR1 hot water is originated from marine sulfur which might be derived ken ancient seawater sulfates. The $^3He/^4He\;and\;^4He/^{20}Ne$ ratios of the hot spring waters range from $0.0143{\times}10^{-6}\;to\;0.407{\times}10^{-6}\;and\;6.49{\sim}584{\times}10^{-6}$, respectively. The hot spring waters are plotted on the mixing line between air and crustal components. It means that the He gas in the hot spring waters was mainly originated from crustal sources. However, the JR1 hot spring water show a little mixing ratio of the helium gas of mantle source. The $^{40}Ar/^{36}Ar$ ratios of hot spring water are in the range from $292.3{\times}10^{-6}\;to\;304.1{\times}10^{-6}$, implying the atmospheric argon source.

Jang(Fermented Soybean) in Official and Royal Documents in Chosun Dynasty Period (조선조의 공문서 및 왕실자료에 나타난 장류)

  • Ann, Yong-Geun
    • The Korean Journal of Food And Nutrition
    • /
    • v.25 no.2
    • /
    • pp.368-382
    • /
    • 2012
  • This paper investigated the system that is relevant to Jang(fermented soybean paste or solution), the relief of hunger-stricken people by Jang, 33 kinds of Jang, and its consumption in the documents, such as the annals of the Chosun Dynasty, Ihlseong-document, Seungjeongwon daily, Uigwe(record of national ceremony), official documents on the basis of Kyujanggak institute for the Korean studies and data base of Korean classics. There are lots of Jang named after the place of particular soybean's production from the ancient times. Jang, soybean, salt and Meju(source of Jang), during the Dynasty, were collected as taxation or tribute. In the 5th year of Hyeonjong(1664), the storage amount of soybean in Hojo(ministry of finance) was 16,200 $k{\ell}$, and its consumption was 7,694 $k{\ell}$ a year. In the 32nd year of Yongjo(1756), the 1,800 $k{\ell}$ of soybean was distributed to the people at the time of disaster, and in his 36th year(1756), the 15,426 $k{\ell}$ of soybean was reduced from the soybean taxation nationwide. The offices managing Jang are Naejashi, Saseonseo, Sadoshi, Yebinshi and Bongsangshi. Chongyoongcheong(Gyeonggi military headquarters) stored the 175.14 $k{\ell}$ of Jang, and the 198 $k{\ell}$ of Jang in Yebinshi. There are such posts managing Jang as Jangsaek, Jangdoo, and Saseonsikjang. In the year of Jeongjong(1777~1800), the royal family distributed the 3.6 $k{\ell}$ of Meju to Gasoon-court, Hygyeong-court, queen's mother-court, queen's court, royal palace. The 13.41 $k{\ell}$ of Gamjang(fermented soybean solution) was distributed to the Gasoon-court, 17.23 $k{\ell}$ to Hegyeong-court, 17.09 $k{\ell}$ to the queen's mother-court, and the 17.17 $k{\ell}$ to the queen's court each. There are 112 Jang-storing pots in the royal storages, and the 690 are in Namhan-hill, where the 2.7 $k{\ell}$ of fermented Jang was made and brought back by them each year. At the time of starvation, Jang relieved the starving people. There are 20 occasions of big reliefs, according to the annals of the Chosun Dynasty. In the 5th year of Sejong(1423), the 360 $k{\ell}$ of Jang was given to the hunger-stricken people. In his 6th year(1424), the 8,512.92 $k{\ell}$ of rice, bean, and Jang was provided and in the 28th year(1446), the 8,322.68 $k{\ell}$ of Jang was also provided to them. In the Dynasty, Jang was given as a salary. In case that when they were bereaved, they didn't eat Jang patiently for its preservation. They were awarded for their filial piety. In the annals of the Chosun Dynasty, there are 19 kinds of Jang. They are listed in the order of Jang(108), Yeomjang(90), Maljang(11), Yookjang(5), Gamjang(4), and etc.,. In Seungjeongwon daily, there are 11 kinds of Jang. Jang(6), Cheongjang (5), Maljang(5), and Tojang(3) are listed in order. In the Ihlseong-document, there are 5 kinds of Jang. They are listed in Jang(15), Maljang(2), Gamjang(2), and etc.,. There are 13 kinds of Jang in Uigwe, and the official documents, in the order of Gamjang(59), Ganjang(37), Jang(28), Yeomjang(7), Maljang(6), and Cheongjang(5). In addition, shi are Jeonshi(7), and Dooshi(4). All these are made of only soybean except, for Yookjang. The most-frequently recorded Jang among anthology, cookbook, the annals of the Chosun Dynasty, Ihlseong-document, Seoungjeongwon daily, Uigwe, or official document is Jang(372), and then Yeomjang(194), Gamjang(73), Cheongjang(46), Ganjang(46), Soojang(33), and Maljang(26), which were made of soybean. Jang from China in cookbook is not in anthology and royal palace documents. Thus, traditional Jang made of soybean was used in the daily food life in the royal court, and in the public during the Chosun period.

Difference in Patient's Work of Breathing Between Pressure-Controlled Ventilation with Decelerating Flow and Volume-Controlled Ventilation with Constant Flow during Assisted Ventilation (보조환기양식으로서 감속형유량의 압력-조절환기와 일정형유량의 용적-조절환기에서 환자의 호흡일의 차이)

  • Kim, Ho-Cheol;Park, Sang-Jun;Park, Jung-Woong;Suh, Gee-Young;Chung, Man-Pyo;Kim, Ho-Joong;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.803-810
    • /
    • 1999
  • Background : The patient's work of breathing(WOBp) during assisted ventilation may vary according to many factors including ventilatory demand of the patients and applied ventilatory setting by the physician. Pressure-controlled ventilation(PCV) which delivers gas with decelerating flow may better meet patients' demand to improve patient-ventilator synchrony compared with volume-controlled ventilation(VCV) with constant flow. This study was conducted to compare the difference in WOBp in two assisted modes of ventilation, PCV and VCV with constant flow. Methods : Ten patients with respiratory failure were included in this study. Initially, the patients were placed on VCV with constant flow at low tidal volume($V_{T,\;LOW}$)(6-8 ml/kg) or high tidal volume($V_{T,\;HIGH}$)(10-12 ml/kg). After a 15 minute stabilization period, VCV with constant flow was switched to PCV and pressure was adjusted to maintain the same tidal volume($V_T$) received on VCV. Other ventilator settings were kept constant. Before changing the ventilatory mode, WOBp, $V_T$, minute ventilation($V_E$), respiratory rate(RR), peak airway pressure (Ppeak), peak inspiratory flow rate(PIFR) and pressure-time product(PTP) were measured. Results : The mean $V_E$ and RR were not different between PCV and VCV during the study period. The Ppeak was significantly lower in PCV than in VCV during $V_{T,\;HIGH}$. HIGH ventilation(p<0.05). PIFR was significantly higher in PCV than in VCV at both $V_T$ (p<0.05). During $V_{T,\;LOW}$ ventilation, WOBp and PTP in PCV($0.80{\pm}0.37\;J/min$, $164.5{\pm}74.4\;cmH_2O.S$) were significantly lower than in VCV($1.06{\pm}0.39J/mm$, $256.4{\pm}107.5\;cmH_2O.S$)(p<0.05). During $V_{T,\;HIGH}$ ventilation, WOBp and PTP in PCV($0.33{\pm}0.14\;J/min$, $65.7{\pm}26.3\;cmH_2O.S$) were also significantly lower than in VCV($0.40{\pm}0.14\;J/min$, $83.4{\pm}35.1\;cmH_2O.S$)(p<0.05). Conclusion : During assisted ventilation, PCV with decelerating flow was more effective in reducing WOBp than VCV with constant flow. But since individual variability was shown, further studies are needed to confirm these results.

  • PDF

The Effect of Deep Layer Split Application of Nitrogen Fertilizer on the Growth of Rice Plant (질소비료(窒素肥料)의 심층추비시용(深層追肥施用)이 수도생육(水稻生育)에 미치는 영향(影響))

  • Maeng, D.W.;Kim, W.C.
    • Applied Biological Chemistry
    • /
    • v.20 no.1
    • /
    • pp.147-155
    • /
    • 1977
  • In this experiment, we expected yield increase depending on the control of ineffective tiller, heightening of effective tillering ratio and continuous supply of nitrogen until later growth stage of rice plant by deep layer split application. Treats were applied at Tongil and Jinheung variety, clayey loam and sandy loam soil, and drained and non-drained condition. Nitrogenous fertilizer application wab adopted as liquefied(50%) and lumped (50% and 80%) fertilizer at 12cm depth of soil before 35 days of rice heading time against the standard soil surface application. The results are summarized as follaw. 1. a. Jinheung showed great variant width of tiller numbers per rice plant growth stage, and low effective tillering ratio at soil surface dressing. But in the case of deep layer split application, the number of tiller increased normally, and effective tillering ratio was high. b. At Tonsil, the width of increase and decrease range of effective tiller number between soil surface dressing and deep layer split application was not so high as Jinheung. Deep layer split application of 80% lumped fertilizer showed maximum effective tillering ratio ($83%{\sim}93%$). C. In the case of Jinheung, it was supposed that deep layer split application of 80% lumped fertilizer was excessive nitrogen quantity. d. Effective tillering ratio was higher than Tonsil at Jinheung. 2. The number of grains per hill was increased by the deep layer split application, but the ripening ratio was decreased inversely with the increase of total grain number. 3. Length of top leaves was elongated at Jinheung by deep layer split application. It showed significant correlation between top leaves length and grain yield. 4. Deep layer split application inclosed N content of harvested straw. Yield and N content of straw showed possitive correlation. 5. The ratio of unhulled grain yield per straw weight was increased by deep layer splication. This ratio was higher at Jinheung than Tonsil. 6. Grain yield was appeared in order of 80% lumped fertilizer>50% lumped fertilizer>50% liquefied fertilizer>surface dressing by the deep layer split application. The yield increasing factors were the increasing of effective tillering ratio, number of panicles per hill and number of ripening grains per hill. 7. Grain yield was increased at Tongil in sandy loam soil and at Jinheung in clayey loam soil by deep layer split application. 8. The grain yield was increased at drained conditions of clayey loam soil and non-drained conditions of sandy loam soil. But in the case of 80% lumped fertilizer of deep layer split application at the sandy loam soil, the yield was not increased at non-drained conditions. 9. The effect of yield increase by deep layer split application comparing with the surface dressing was higher at Tonsil than ginheung, in spite of low ripening ratio of Tonsil caused by low temperature at heading and harvesting time.

  • PDF

Actual Results on the Control of Illegal Fishing in Adjacent Sea Area of Korea (한국 연근해 불법어업의 지도 단속 실태)

  • Lee, Sang-Jo;Kim, Jin-Kun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.10 no.2
    • /
    • pp.139-161
    • /
    • 1998
  • This thesis includes a study on the legal regulation, the system and formalities on the control of illegal fishing. And the author analyzed the details of the lists of illegal fishing controlled by fishing patrol vessels of Ministry of Maritime Affairs and Fisheries from 1994 to 1996 in adjacent sea area of Korea. The results are summarized as follows ; 1. The fishing patrol vessels controlled total 826 cases in 2,726 days of 292 voyages by 17 vessels in 1994, total 1,086 cases in 3,060 days of 333 voyages by 18 vessels in 1995 and total 933 cases in 3,126 days of 330 voyages by 19 vessels in 1996. 2. The fishing period of illegal fishing was generally concentrated from April to September. But year after year, illegal fishing was scattered throughout the year. 3. The most controlled sea area of illegal fishing was the south central sea area in the sea near Port of Tongyeong. The sea area occupied about 36~51% of totality and the controlled cases were gradually increased every year. The second was the south western sea area in the sea near Port of Yosu. The sea area occupied about 18-27% and the controlled cases were a little bit increased every year. The third was the south eastern sea area in the sea near Pusan. The sea area occupied about 13~23% and the controlled cases were gradually decreased year by year. 4. The most controlled kind of illegal fishing was the small size bottom trawl. This occupied about 81-95% of totality and the controlled cases were gradually increased year by year. The second was the medium size bottom trawl. This occupied about 4-7% and the controlled cases were gradually decreased year by year. The third was the trawl of the coastal sea, this occupied about 2~4% and the controlled cases were a little bit decreased every year. 5. The most controlled address of illegal fishing manager was Pusan city which occupied about 33-51% of totality. The second was Cheonnam which occupied about 24-29%. The third was Kyungnam which occupied about 16~35%. 6. The most controlled violation of regulations was Article 57 of the Fisheries Act which occupied about 56-64% of totality. The second was Article 23 of Protectorate for Fisheries Resources which occupied about 21-36%. And the controlled cases by it were gradually increased every year.

  • PDF