• Title/Summary/Keyword: '그리고'

Search Result 82,769, Processing Time 0.115 seconds

An influence of operator's posture on the shape of prepared tooth surfaces for fixed partial denture (진료자세가 고정성 국소의치의 지대치 삭제에 미치는 영향)

  • Won, In-Jae;Kwon, Kung-Rock;Pae, Ah-Ran;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.38-48
    • /
    • 2011
  • Purpose: Dentists suffer back, neck and shoulder pain during their careers due to bad operating posture. If dentists have a good operating posture ergonomically, there would be less pain and discomfort in the shoulder and back. Therefore, dentists should learn the Home position which enables dentists to approach a stable posture ergonomically. This study was to compare tooth preparation in the Home position and the Random position, and evaluate the clinical efficacy of the Home position. Materials and methods: Tooth preparation for fixed partial denture was performed on the maxillary left 2nd premolar and maxillary left 2nd molar at the two different operating positions were compared. The amount of occlusal reduction, marginal width, subgingival margin depth, and convergence angle were measured. A T-test was performed separately to compare the results of the Random position and the Home position. Results: 1. The amounts of average thickness of occlusal reduction on fossa were deficient to the ordered ones in the Random position and the Home position (P > .05). 2. The average subgingival margin depth of prepared margin on maxillary left 2nd premolar, maxillary left 2nd molar were excessive in the Random position than in the Home position. On the maxillary left 2nd premolar, there was no statistical difference in the Random position and the Home position except Distal midline, DL line angle, Lingual midline, ML line angle (P< .05). On the maxillary left 2nd molar, there was no statistical difference in the Random position and the Home position (P < .05). 3. Average convergence angle in the Random position and the Home position were excessive compared to the ordered angle. There was no statistical difference in the Random position and the Home position (P > .05). 4. Analysis of pearson correlation : In the Random position, the amounts of average thickness of occlusal reduction, the average subgingival margin depth of prepared margin, convergence angle were significantly associated with each other (P < .05). But in the Home position, they were not significantly associated with each other (P < .05). 5. The time needed for preparation in the Home position was faster or equal than that of the Random position as time went on. Conclusion: In conclusion, there were no significant differences between Home position and Random position in measures of occlusal reduction, marginal width, marginal depth, convergence angle. However, preparation time and incidence of damaging adjacent teeth were less in Home position than in Random position. Therefore, if trained properly, Home position which is more ergonomically stable can be adopted for clinical use.

COMPARISON OF POLYMERIZATION SHRINKAGE AND STRAIN STRESS OF SEVERAL COMPOSITE RESINS USING STRAIN GUAGE (스트레인 게이지를 이용한 수종의 복합레진의 중합수축 및 수축응력의 비교)

  • Kim, Young-Kwang;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.516-526
    • /
    • 2004
  • Polymerization shrinkage of photoinitiation type composite resin cause several clinical problems. The purpose of this study was to evaluate the shrinkage strain stress, linear polymerization shrinkage, compressive strength and microhardness of recently developed composite resins. The composite resins were divided into four groups according to the contents of matrix and filler type. Group I : $Denfil^{TM}$(Vericom, Korea) with conventional matrix, Group II : $Charmfil^{(R)}$(Dentkist, Korea) with microfiller and nanofller mixture, Group III : $Filtek^{TM}$ Z250(3M-ESPE, USA) TEGDMA replaced by UDMA and Bis-EMA(6) in the matrix, and Group IV : $Filtek^{TM}$ Supreme(3M-ESPE, USA) using pure nanofiller. Preparation of acrylic molds were followed by filling and curing with light gun. Strain gauges were attached to each sample and the leads were connected to a strainmeter. With strainmeter shrinkage strain stress and linear polymerization shrinkage was measured for 10 minutes. The data detected at 1 minute and 10 minutes were analysed statistically with ONE-way ANOVA test. To evaluate the mechanical properties of tested materials, compressive hardness test and microhardness test were also rendered. The results can be summarized as follows : 1. Filling materials in acrylic molds showed initial temporary expansion in the early phase of polymerization. This was followed by contraction with the rapid increase in strain stress during the first 1 minute and gradually decreased during post-gel shrinkage phase. After 1 minute, there's no statistical differences of strain stress between groups. The highest strain stress was found in group IV and followed by group III, I, II at 10 minutes-measurement(p>.05). In regression analysis of strain stress, group III showed minimal inclination and followed by group II, I, IV during 1 minute. 2. In linear polymerization shrinkage test, the composite resins in every group showed initial increase of shrinkage velocity during the first 1 minute, followed by gradually decrease of shrinkage velocity. After 1 minute, group IV and group III showed statistical difference(p<.05). After 10 minutes, there were statistical differences between group IV and group I, III(p<.05) and between group II and group III(p<.05). In regression analysis of linear polymerization shrinkage, group II showed minimal inclination and followed by group IV, III, I during 1 minute. 3. In compressive strength test, group III showed the highest strength and followed by group II, IV, I. There were statistical differences between group III and group IV, I(p<.05). 4. In microhardness test, upper surfaces showed higher value than lower surfaces in every group(p<.05).

  • PDF

The Smoking Habits among the OPD Patients and The Success Rates of the Physician's Cessation Order (내과 외래환자에 있어서 흡연 양상과 의사의 금연권고의 성공률)

  • Park, Ki-Chan;Kim, Young-Hoo;Bae, Seong;Lee, Sang-Hun;Chun, Myung-Ho;Lee, Sang-Ki;Jun, Kwang-Su;Lee, Chan-Se
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.292-300
    • /
    • 1993
  • Background: To evaluate the effect of doctor's cessation order Methods: From January 1989 to December 1990, Total 1981 patients (male 922, female 1059), who visited OPD of Daedong hospital were selected to investigate the cigarette smoking habits and the success rates of the physician's cessation orders. Results: 1) Among male patients, 64.43% and 27.00% revealed as smoke and non-smoker, respectively and and 8.57% as ex-smoker. In the 20 years old or less age group smoker were 36.11%. 2) Among female patients, the rates of smoker were only 2.83%, ex-smoker were 0.38%. No female patient smoked under 20 years old. 3) As compared with the number of daily smoked cigarettes among the male patients, patient who smoked less than 10 cigarettes were in 2.69%, 11-20 cigarettes in 39.23%, 21-40 cigarettes in 46.30%, more than 40 cigarettes in 11.78%, under 20 years old age gorup the number of smoked cigarettes were 11.54%, 61.54%, 23.08%, 3.84% respectively. Among female patients, smoker were only 37 patients and the number of daily used cigarette were 2.7%, 67.57%, 24.32%, 5.41% respectively. 4) As compared with systemic disease and the smoking habits, female excluded from statistics because of too small number of smoker. Among male patients ex-smoker associated with respiratory disease were 15.21% which was much higher than other disease group (4.35%-8.11%), and among cardiovascular diseae patients, smoker were 81.08% & among cardiovascular disease patients, smoker were 81.08% & among gastrointestinal disease patient 68.93% and among respiratory disease patient 60.84%. In respiratory disease patients group 16.25% smoked more than 40 cigarettes dialy and 13.01% in gastrointestinal disease patients group. 5) Among patients who treated more than 3 months via OPD the success rates of the physcian's cessation order were 62.03% of male patients (we excluded female patients) and there is no gross difference in each age group, but it was highest as 75% in 41-60 years old age group. As compared with difference of systeic disease, the success rate were highest in respiratory disease patients as 78.13% and lowest in gastrointestinal disease patients as 49.94% Conclusion: The smoking rates among the out patients including male and female of internal medical department of General Hospital were same as the general population. Although the sample size was small, on account of the success rates of physician's cessation orders were more than half, we think the cessation recommendation by physician's order is very effective. And we think the cessation recommendation are more effective. And we think the cessation recommendation are more effective than the ex-smoking education in the excluded patients due to fail to follow up more than 3 months.

  • PDF

Usefulness of Tuberculin Skin Test by Tuberculin PPD RT23 2 TU (Tuberculin PPD RT23 2 TU를 이용한 투베르쿨린 피부반응 검사의 의의)

  • Yang, Jong-Wuk;Jeon, Man-Jo;Kim, Sung-Jung;Lee, Hyang-Lim;Lee, Seung-Jun;Lee, Myoung-Goo;Kim, Dong-Gyu;Park, Myoung-Jae;Kang, Min-Jong;Hyoen, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.401-408
    • /
    • 2002
  • Background : Tuberculin skin test is a method to examine M. tuberculosis infection and has been used all over the world. But various factors make it difficult to understand testing results. In 2000, the American Thoracic Society recommended that skin test results should be decided by considering risk factors of the tested. In Korea, high tuberculosis infection rate and BCG vaccination rate make it difficult to differentiate current infection, past infection, and no infection by the skin test. This study was attempted to examine a negative predictive value of the skin test to understand how the skin test acts on deciding administration of anti-tuberculosis drug. Methods : From Mar. 1 to Jul. 31 in 2001, the test was performed for patients hospitalized in Department of Internal Medicine, Hallym University College of Medicine, Chunchon, Korea by administering Tuberculin PPD RT23 2 TU (0.1 ml)to them that has been currently used in Korea based on Mantoux method. They were decided to be infected with tuberculosis bacilli by following diagnostic standard: 1) tuberculosis bacilli was cultured in sputum by microbiological diagnostic standard or Acid-fast bacilli was proven on a microscopic examination or 2) tuberculosis bacilli was not proven in the aforesaid microbiological test by clinical diagnostic standard, while there was opinion or symptom suitable for tuberculosis by radiographic or histological standard so the doctor decided to apply the tuberculosis treatment. Results : In this study, total 210 patients except 20 patients (8.7%) among 230 hospitalized patients were evaluated. Their average age was 60±16.8 years, and male-female rate was 1.28 : 1 (male: 118, female: 92). Number of patient, who was diagnosed and decided as tuberculosis, was 53(25.2%). Pulmonary tuberculosis was found in 45 patients (84.9%); 22 patients were decided to be positive in the Acid-fast bacilli smear test by microbiological examination (culture positive: 13, culture negative: 9), and 23 patients were decided to be tuberculosis patients by clinical diagnosis standard. Tuberculosis pleuritis was found in 8 patients (15.1%); 4 patients were diagnosed and decided by histological standard, and 4 patients were decided and treated by clinical standard. In differentiating patients into 'Negative' and 'Positive' by the skin test standard of the American Thoracic Society, negative predictive value 92.3%, positive predictive value 47.3%, sensitivity and specificity were 83%, 68.8%, respectively. Conclusion : In hospitalized respiratory patients, there was high negative predictive vlaue 92.3% by tuberculin skin test, therefore skin test would be a important factor for deciding administration of anti-tuberculosis drug on negative skin test patient.

The Effect of Surfactant on Neutrophil Apoptosis in Lipopolysaccharide Induced Acute Lung Injury in Rat (기관내 내독소 투여로 유도한 백서의 급성 폐손상 모델에서 surfactant가 호중구의 아포토시스에 미치는 영향)

  • Yoo, Ji-Hoon;Lee, Byoung-Jun;Jeong, Do-Young;Lee, Sang-Hoon;Shin, Jong-Wook;Kim, Jae-Yeol;Park, In-Won;Choi, Byoung-Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.409-419
    • /
    • 2002
  • Background : The therapeutic effects of surfactant on acute lung injury derive not only from its recruiting action on collapsed alveoli but also from its anti-inflammatory effects. Pro-apoptotic action on alveolar neutrophils represents one of the important anti-inflammatory mechanisms of surfactant. In the present study, we evaluated the effects of sufactant on the apoptosis of human peripheral and rat alveolar neutrophils. Methods : In the (Ed- the article is not definitely needed but it helps to separate the two prepositions 'in') in vitro study, human neutrophils were collected from healthy volunteers. An equal number of neutrophils ($1{\times}10^6$) (Ed-confirm) was treated with LPS (10, 100, 1000ng/ml), surfactant (10, 100, $1000{\mu}g/ml$), or a combination of LPS (1000ng/ml) and surfactant (10, 100, $1000{\mu}g/ml$). After incubation for 24 hours, the apoptosis of neutrophils was evaluated by Annexin V method. In the in vivo study, induction of acute lung injury in SD rats by intra-tracheal instillation of LPS (5mg/kg) was followed by intra-tracheal administration of either surfactant (30mg/kg) or normal saline (5ml/kg). Tenty-four hours after LPS instillation, alveolar neutrophils were collected and the apoptotic rate was evaluated by Annexin V method. In addition, changes of the respiratory mechanics of rats (respiratory rate, tidal volume, and airway resistance) were evaluated with one chamber body plethysmography before, and 23 hours after, LPS instillation. Results : in the in vitro study, LPS treatment decreased the apoptosis of human peripheral blood neutrophils (control: $47.4{\pm}5.0%$, LPS 10ng/ml; $30.6{\pm}10.8%$, LPS 100ng/ml; $27.5{\pm}9.5%$, LPS 1000ng/ml; $24.4{\pm}7.7%$). The combination of low to moderate doses of surfactant with LPS promoted apoptosis (LPS 1000ng/ml + Surf $10{\mu}g/ml$; $36.6{\pm}11.3%$, LPS 1000ng/ml +Surf $100{\mu}g/ml$; $41.3{\pm}11.2%$). The high dose of surfactant ($1000{\mu}g/ml$) decreased apoptosis ($24.4{\pm}7.7%$) and augmented the anti-apoptotic effect of LPS (LPS 1000ng/ml + Surf $1000P{\mu}g/ml$; $19.8{\pm}5.4%$). In the in vivo study, the apoptotic rate of alveolar neutrophils of surfactant-treated rats was higher than that of normal saline-treated rats ($6.03{\pm}3.36%$ vs. $2.95{\pm}0.58%$). The airway resistance (represented by Penh) of surfactant-treated rats was lower than that of normal saline-treated rats at 23 hours after LPS injury ($2.64{\pm}0.69$ vs. $4.51{\pm}2.24$, p<0.05). Conclusion : Surfactant promotes the apoptosis of human peripheral blood and rat alveolar neutrophils. Pro-apoptotic action on neutrophils represents one of the important anti-inflammatory mechanisms of surfactant.

The Continuous Monitoring of Oxygen Saturation During Fiberoptic Bronchoscopy (기관지내시경 검사시 지속적인 동맥혈 산소포화도 감시의 필요성)

  • Kang, Hyun Jae;Kim, Yeon Jae;Chyun, Jae Hyun;Do, Yun Kyung;Lee, Byung Ki;Kim, Won Ho;Park, Jae Yong;Jung, Tae Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.4
    • /
    • pp.385-394
    • /
    • 2002
  • Background : Flexible fiberoptic bronchoscopy(FFB) has become a widely performed technique for diagnosing and managing pulmonary disease because of its low complication and mortality rate. Since the use of FFB can in patients with severely depressed cardiorespiratory function is increasing and hypoxemia during the FFB can induce significant cardiac arrhythmias, the early detection and adequate management of hypoxemia during FFB is clinically important. Method : To evaluate the necessity of the continuous monitoring of the oxygen saturation($SaO_2$) during the FFB, the $SaO_2$ was continuously monitored from the finger tip using pulse oximetry before, during and after the FFB in 379 patient. The patients were then divided into two groups, those with and without hypoxemia($SaO_2$<90%). The baseline pulmonary function data and the clinical characteristics of the two groups were compared. Results : The mean baseline $SaO_2$ was $96.9{\pm}2.85%$. An $SaO_2$ <90% was recorded at some point in 62(16.4%) out of 379 patients, with 12 out of 62 experiencing this prior to the FFB, in 37 out of 62 during the FFB, and in 13 out of 62 after the FFB. No differences were observed in the smoking and sex distribution between those with and without hypoxemia. The mean age was older in those with hypoxemia than in those without. Significant differences were observed in the mean baseline $SaO_2$ and the mean time for the procedure between the two groups. The $FEV_1$ was significantly lower in those with hypoxemia, and both the FVC and $FEV_1/FVC$ also tended to decrease in this group. Managing hypoxemia included deep breathing in 20 patients, a supplemental oxygen supply in 39 patients, and the abortion of the procedure in 3 patients. Conclusion : These results suggest that the continuous monitoring of the oxygen saturation is necessary during fiberoptic bronchoscopy, and it should be performed in patients with a depressed pulmonay function in order for the early detection and adequate management of hypoxemia.

A Clinical Study on Transpulmonary Leukostasis and Prophylactic Effects of Steroid in Cardiac Surgery (심장수술시 백혈구의 폐내정체와 스테로이드의 예방적 효과에 관한 연구)

  • 최석철
    • Biomedical Science Letters
    • /
    • v.2 no.2
    • /
    • pp.133-151
    • /
    • 1996
  • After cardiac surgery, it has been recognized that various complications were associated with injured humoral and cellular immunity by cardiopulmonary bypass(CPB). Especially, in postoperative pulmonary dysfunction, transpulmonary leukostasis followed complement activation and inflammatory responses are major pathogen. Some studies have showed that pretreated-corticosteroids before CPB protected postoperative pulmonary dysfunction. Corticosteroids may inhibit complement and leukocyte activation. On based previous studies, present investigator determined changes of leukocyte counts and transpulmonary leukostasis during cardiac surgery and postoperative periods. For the evaluation of postoperative pulmonary function and edema, $PaO_2$ and chest X-ray were compared between pre-CPB and post-CPB. Fever and other parameters were also observed postoperatively. The aim of this study was to define for the prophylactic effects of corticosteroid(Solu-Medrol: 30mg/kg) on all the researched parameters. This study was prospectively designed with randomized-blind fashion for 50 patients undergoing cardiac surgery. According to the purpose of study, all patients were divided into placebo and steroid group. : Placebo group was 25 patients received normal saline(not corticosteroid), and steroid group was 25patients received corticosteroid(Solu-Medrol: 30mg/kg) before initiation of CPB. The results of study were summarized as follows. 1. Total peripheral leukocyte counts decreased significantly at 5 minutes of CPB in all patients(P<0.01), and began to increase progressively at later periods of CPB with neutrophilia. The significant rise remained at postoperative 7th day(P<0.05). 2. During partial CPB, transpulmonary leukostasis occurred in placebo group(P<0.001), whereas it was prevented in steroid group. 3. In both groups, peripheral lymphocyte counts were stable during CPB, but began to reduce at time of intensive care unit(ICU) and the lymphocytopenia remained until postoperative 3rd day. The lymphocyte counts recovered on postoperative 7th day. 4. In both groups, peripheral counts of monocyte were relatively stable in the early peroid of CPB, and increased gradually in the later periods of CPB. This significant monocytosis remained throughout postoperlative periods(P<0.05). 5. The mean value of postoperative $paO)_2$ was lower than that of pre-CPB in placebo group(P=0.01) but didn't significant in steroid group(P=0.90). In the incidence of pulmonary edema signs and fever, placebo group was higher than steroid group(P=0.001, p=0.01, respectively). However mechanical respiratory supporting and care periods at intensive care unit were not significant difference between two groups(P>.0.05).With the above results, the investigator concluded that leukocyte activation and pulmonary sequestration were caused by cardiac surgery with CPB and demonstrated that high dose corticosteroid will provide prophylactic effect for pulmonary leukostasis and higher neutrophilia. These effects may ameliorate postoperative pulmonary dysfunction and contribute to postoperative less morbidity. However, further study should be performed because postoperative lymphocytopenia continued for 3 days in both groups, which may suspected damage or suppression of cell-mediated immunity with used corticosteroid.

  • PDF

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.

Case study of Music & Imagery for Woman with Depression (우울한 내담자를 위한 MI(Music & Imagery) 치료사례)

  • Song, In Ryeong
    • Journal of Music and Human Behavior
    • /
    • v.5 no.1
    • /
    • pp.67-90
    • /
    • 2008
  • This case used MI techniques that give an imagery experience to depressed client's mental resource, and that makes in to verbalism. Also those images are supportive level therapy examples that apply to positive variation. MI is simple word of 'Music and Imagery' with one of psychology cure called GIM(Guided Imagery and Music). It makes client can through to the inner world and search, confront, discern and solve with suitable music. Supportive Level MI is only used from safety level music. Introduction of private session can associate specification feeling, subject, word or image. And those images are guide to positive experience. The First session step of MI program is a prelude that makes concrete goal like first interview. The Second step is a transition that can concretely express about client's story. The third step is induction and music listening. And it helps to associate imagery more easily by used tension relaxation. Also it can search and associate about various imagery from the music. The last step is process that process drawing imagery, talking about personal imagery experience in common with therapist that bring the power by expansion the positive experience. Client A case targets rapport forming(empathy, understanding and support), searching positive recourse(child hood, family), client's emotion and positive support. Music must be used simple tone, repetition melody, steady rhythm and organized by harmony music of what therapist and client's preference. The client used defense mechanism and couldn't control emotion by depression in 1 & 2 sessions. But the result was client A could experience about support and understanding after 3 sessions. After session 4 the client had stable, changed to positive emotion from the negative emotion and found her spontaneous. Therefore, at the session 6, the client recognized that she will have step of positive time at the future. About client B, she established rapport forming(empathy, understanding and support) and searching issues and positive recognition(child hood, family), expression and insight(present, future). The music was comfortable, organizational at the session 1 & 2, but after session 3, its development was getting bigger and the main melody changed variation with high and low of tune. Also it used the classic and romantic music. The client avoids bad personal relations to religious relationship. But at the session 1 & 2, client had supportive experience and empathy because of her favorite, supportive music. After session 3, client B recognized and face to face the present issue. But she had avoidance and face to face of ambivalence. The client B had a experience about emotion change according depression and face to face client's issues After session 4. At the session 5 & 6, client tried to have will power of healthy life and fairly attitude, train mental power and solution attitude in the future. On this wise, MI program had actuality and clients' issues solution more than GIM program. MI can solute the issue by client's based issue without approach to unconsciousness like GIM. Especially it can use variety music and listening time is shorter than GIM and structuralize. Also can express client's emotion very well. So it can use corrective and complement MI program to children, adolescent and adult.

  • PDF

The Alignment Evaluation for Patient Positioning System(PPS) of Gamma Knife PerfexionTM (감마나이프 퍼펙션의 자동환자이송장치에 대한 정렬됨 평가)

  • Jin, Seong Jin;Kim, Gyeong Rip;Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.203-209
    • /
    • 2020
  • The purpose of this study is to assess the mechanical stability and alignment of the patient positioning system (PPS) of Leksell Gamma Knife Perfexion(LGK PFX). The alignment of the PPS of the LGK PFX was evaluated through measurements of the deviation of the coincidence of the Radiological Focus Point(RFP) and the PPS Calibration Center Point(CCP) applying different weights on the couch(0, 50, 60, 70, 80, and 90 kg). In measurements, a service diode test tool with three diode detectors being used biannually at the time of the routine preventive maintenance was used. The test conducted with varying weights on the PPS using the service diode test tool measured the radial deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. In order to evaluate the alignment of the PPS, the radial deviations of the correspondence of the radiation focus and the LGK calibration center point of multiple beams were averaged using the calibrated service diode test tool at three university hospitals in Busan and Gyeongnam. Looking at the center diode for all collimators 4, 8, and 16 mm without weight on the PPS, and examining the short and long diodes for the 4 mm collimator, the means of the validation difference, i.e., the radial deviation for the setting of 4, 8, and 16 mm collimators for the center diode were respectively measured to 0.058 ± 0.023, 0.079 ± 0.023, and 0.097 ± 0.049 mm, and when the 4 mm collimator was applied to the center diode, the short diode, and the long diode, the average of the radial deviation was respectively 0.058 ± 0.023, 0.078 ± 0.01 and 0.070 ± 0.023 mm. The average of the radial deviations when irradiating 8 and 16 mm collimators on short and long diodes without weight are measured to 0.07 ± 0.003(8 mm sd), 0.153 ± 0.002 mm(16 mm sd) and 0.031 ± 0.014(8 mm ld), 0.175 ± 0.01 mm(16 mm ld) respectively. When various weights of 50 to 90 kg are placed on the PPS, the average of radial deviation when irradiated to the center diode for 4, 8, and 16 mm is 0.061 ± 0.041 to 0.075 ± 0.015, 0.023 ± 0.004 to 0.034 ± 0.003, and 0.158 ± 0.08 to 0.17 ± 0.043 mm, respectively. In addition, in the same situation, when the short diode for 4, 8, and 16 mm was irradiated, the averages of radial deviations were 0.063 ± 0.024 to 0.07 ± 0.017, 0.037 ± 0.006 to 0.059 ± 0.001, and 0.154 ± 0.03 to 0.165 ± 0.07 mm, respectively. In addition, when irradiated on long diode for 4, 8, and 16 mm, the averages of radial deviations were measured to be 0.102 ± 0.029 to 0.124 ± 0.036, 0.035 ± 0.004 to 0.054 ± 0.02, and 0.183 ± 0.092 to 0.202 ± 0.012 mm, respectively. It was confirmed that all the verification results performed were in accordance with the manufacturer's allowable deviation criteria. It was found that weight dependence was negligible as a result of measuring the alignment according to various weights placed on the PPS that mimics the actual treatment environment. In particular, no further adjustment or recalibration of the PPS was required during the verification. It has been confirmed that the verification test of the PPS according to various weights is suitable for normal Quality Assurance of LGK PFX.