• 제목/요약/키워드: $a^*/b^*$ value

검색결과 7,843건 처리시간 0.033초

한국형 육가공 제품류의 물리적 및 관능적 품질 특성 (Physical and Sensory Characteristics of Korean Style Meat Products)

  • 김일석;진상근;하경희;류현지;박기훈
    • Journal of Animal Science and Technology
    • /
    • 제47권1호
    • /
    • pp.49-56
    • /
    • 2005
  • The Korean styled meat products such as grilled and/or roasted ham(Jikhwagui: J), Bulgogi ham(B), Kimbab ham(K) and sliced roasted ham(DDukgalbi: D) were obtained from different Korean meat processing companies and investigated for their salinity, saccharinity, pH, moisture and fat content, meat color and sensory evaluation. The results obtained were as follows; Percentage of saccharinity in J, B, K and D ranged 7.5 %(13) - 12.7% (J2), 5.3 0/«B2) -7.5 o/«BI), 5.2 0/«K4) - 6.6 o/«KI, K2, KS), and 6.60/«04) - 14.4o/«Dl), respectively. Percentage of salinity in J, B, K and D ranged 2.260/«13)- 2.38 0/«J4), 1.850/«B2) - 2.45 0/«B3), 1.94o/«KI) - 2.40% (K3), and 1.830/«02) - 2.19 o/«Dl), respectively. The pH value of J, B and K were ranged 6.30 - 6.44, 6.266.37 and 6.20 - 6.42, respectively, which are slightly higher than that of D(5.86 - 6.25). Content of average moisture were higher in B(61.0 %), K(59.94%) and J(59.63%) compared to the D(55.93%). In crude fat, B and D were ranged 14-21 %, which are very lower than those of K(59.94%) and J(59.63%). In meat color, $L^*$ value were above 50.0, except D2 and D3. $a^*$ value of B were slightly higher than those of other meat products. Compared to sensory evaluation, the overall acceptability of J is excellent in the range of saccharinity 12.7%, salinity 2.3 %, moisture 61 %, crude fat II - 12%, $L^*$ value 52 - 54, and $a^*$ value 12.3- 12.7. In the case of B, the overall acceptability is excellent in the range of saccharinity 6.6 - 7.5 %, salinity 1.90- 2.45 %, moisture 60 %, crude fat 15 %, $L^*$ value 56, and $a^*$ value 15. In the case of K, the overall acceptability is excellent in the range of saccharinity 6.5 %, salinity 2.4 %, moisture 61 %, crude fat 16%, $L^*$ value 53, and $a^*$ valuce 15. In the case of D, the overall acceptability is excellent in the range of saccharinity 14.0%, salinity 2.1 %, moisture 55%, crude fat 55%, $L^*$ value 50, and $a^*$ value 13.

고해상도 천연색 LED 디스플레이 시스템을 위한 흰색 보정프로세서의 설계 (Design of White Balance Correction Processor for High Resolution Full Color LED Display System)

  • 이종하;고덕영
    • 전자공학회논문지 IE
    • /
    • 제46권3호
    • /
    • pp.12-18
    • /
    • 2009
  • 본 논문은 LED 디스플레이 시스템에서 균일하고 부드러운 영상표출을 위하여 각각의 Red, Green, Blue LED의 휘도를 조절하여 흰색보정을 유지할 수 있는 프로세서를 설계하였다. 이 프로세서는 일반적인 LED소자의 특성곡선을 근거로 "a"를 고유특성 값, "b"를 사용시간에 따른 휘도보정 값, "X"를 구동전류 값, "Y"를 휘도 값이라 할 때, "Y=aX+b"로 설정되는 휘도 특성함수에 의하여 각 픽셀의 휘도에 따른 구동 전류 값을 산출하여 휘도를 보정하고, 또한 장시간 사용 시 LED소자의 휘도 저하 문제를 해결하기 위하여 "b"값을 조절하여 LED 디스플레이 시스템의 전체 평균 휘도 값을 상향시킬 수 있도록 구현하였다.

Studies on Cocoon Filament Size Deviation in Multivoltine Breeds and Multivoltine ${\times}$ Bivoltine Hybrids of Silkworm, Bombyx mori L.

  • Rao, D.Raghavendra;Singh, Ravindra;Kariappa, B.K.;Dandin, S.B.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제9권2호
    • /
    • pp.273-277
    • /
    • 2004
  • Variation in the size of the silk filament will determine the uniformity and quality of the silk reeled. In the present study, an attempt has been made to study the filament size variation in 6 multivoltine parental breeds and 9 multivoltine ${\times}$ bivoltine hybrids in all three seasons of a year. All multivoltine breeds and multivoltine ${\times}$ bivoltine hybrids showed variation in filament size throughout its length from the outer layer to inner layer. Results of the present study indicated that the size of the filament decreased from outer to inner layer. The decrease in filament size was sudden in some breeds/hybrids whereas it was gradual in other. Relationship between filament length to that of slope, average filament size to slope, and maximum filament size to slope was determined based on regression analysis. Regression analysis revealed significant positive correlation between slope vs average filament length (r=0.92$^{**}$) in multivoltine${\times}$bivoltine hybrids. Among parental breeds, 96C showed lowest slope of the curve (b-value: -0.00428) and 96A showed highest slope of the curve (b-value: -0.00269). Among 9 hybrids, PM${\times}$N $B_4$ $D_2$ recorded lowest slope value (b-value: -0.00328) and BL24${\times}$N $B_4$ $D_2$ showed highest value for slope of the curve (b-value: -0.00234). The breed 96C, which showed lowest slope value can be utilized for future breeding programmes to breed strains with less size deviation. Three multivoltine${\times}$bivoltine hybrids viz., PM${\times}$N $B_4$ $D_2$, 96E${\times}$CSR19 and BL67${\times}$CS $R_{101}$ , which showed less slope values (b-values: -0.00328, -0.00300 and -0.00297 respectively) can be utilized for commercial exploitation to produce uniform silk.k.

호박즙의 유지에 대한 항산화 효과 (A Study on Some Antioxidative Effects of Stewed Pumpkin Juice on Lipid)

  • 오봉윤;박복희
    • 한국가정과학회지
    • /
    • 제1권2호
    • /
    • pp.89-99
    • /
    • 1998
  • This study was carried out to investigate some antioxidative effects of stewed pumpkin juice (SPJ) and the SPJs added with ginger (SPJ-G), onion (SPJ-O), jujube (SPJ-J) or boxthorn (SPJ-B), respectively, on the lipid oxidation of soybean oil (S) and mackerel pike boiled ground (MPBG). Antioxidative substances of SPJ were extracted by using the two solvent layers of n-hexane:acetone (1:1)(H) and methanol:water (7:3)M. The antioxidative effects of the extracts were observed by the peroxide value (P.O.V.) and thiobabituric acid (T.B.A.) value. The P.O.V. and T.B.A. value of two solvent extracts of S and MPBG showed significantly lower than those of S and MPBG. The SPJ showed very distingnished antioxidative effects. It was considered that melanoidine extracted by using methanol:water (7:3) solvent as well as carotenoid extracted by using n-hexane:acetone (1:1) solvent had an antioxidative effect. During storage, T.B.A. value of MPBG significantly increased, while that of MPBG-SPJ significantly decreased more than that of MPBG. T.B.A. value of MPBG-SPJs decreased much than that of MPBG-SPJ, SPJ-O, SPJ-G, SPJ-J and SPJ-B, in order of abundance, showed higher level of antioxidative effects than SPJ. (Korean J Human Ecology 1(2):89∼99, 1998)

  • PDF

착색시간에 따른 칼라렌즈 색좌표 이동 (Color lens CIE L*a*b* coordination transfer by tinted time)

  • 정병만;박광호;김용근
    • 한국안광학회지
    • /
    • 제8권1호
    • /
    • pp.53-57
    • /
    • 2003
  • 5분 간격으로 착색시간을 증가시켜 R, G, Y, B칼라렌즈를 제작하였다. 색 좌표 분석은 분광측색계와 CIE $L^*a^*b^*$ color system를 사용하였다. 착색 시간에 따른 색좌표 이동 형태는 $b^*(Y-B)={\beta}a^*+{\alpha}$이며, 거의 선형적으로 변하였다. 적색의 경우 착색시간이 길수록 $G{\rightarrow}R$, $B{\rightarrow}Y$ 형태로 이동하고, Parameter ${\alpha}$, ${\beta}$ 값은 각각 -3.49, 0.90을 얻었다. 녹색의 경우 색좌표 이동은 $R{\rightarrow}G$, $B{\rightarrow}Y$ 형태이다. 10분의 착색 시간에서 가장 순수한 녹색 칼라를 얻었다. Parameter ${\alpha}$, ${\beta}$값은 각각 -0.72, -0.55을 얻었다. 황색과 청색의 경우 모두 착색 시간이 길수록 순수한 색이 된다. 황색에서 Parameter ${\alpha}$, ${\beta}$값은 각각 14.11, 1.58이고, 청색에서 Parameter ${\alpha}$, ${\beta}$값은 각각 -11.62, 1.30을 얻었다.

  • PDF

Why Is a b-value Range of 1500-2000 s/mm2 Optimal for Evaluating Prostatic Index Lesions on Synthetic Diffusion-Weighted Imaging?

  • So Yeon Cha;EunJu Kim;Sung Yoon Park
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.922-930
    • /
    • 2021
  • Objective: It is uncertain why a b-value range of 1500-2000 s/mm2 is optimal. This study was aimed at qualitatively and quantitatively analyzing the optimal b-value range of synthetic diffusion-weighted imaging (sDWI) for evaluating prostatic index lesions. Materials and Methods: This retrospective study included 92 patients who underwent DWI and targeted biopsy for magnetic resonance imaging (MRI)-suggested index lesions. We generated sDWI at a b-value range of 1000-3000 s/mm2 using dedicated software and true DWI data at b-values of 0, 100, and 1000 s/mm2. We hypothesized that lesion conspicuity would be best when the background (i.e., MRI-suggested benign prostatic [bP] and periprostatic [pP] regions) signal intensity (SI) is suppressed and becomes homogeneous. To prove this hypothesis, we performed both qualitative and quantitative analyses. For qualitative analysis, two independent readers analyzed the b-value showing the best visual conspicuity of an MRI-suggested index lesion. For quantitative analysis, the readers assessed the b-value showing the same bP and pP region SI. The 95% confidence interval (CI) or interquartile range of qualitatively and quantitatively selected optimal b-values was assessed, and the mean difference between qualitatively and quantitatively selected b-values was investigated. Results: The 95% CIs of optimal b-values from qualitative and quantitative analyses were 1761-1805 s/mm2 and 1640-1771 s/mm2 (median, 1790 s/mm2 vs. 1705 s/mm2; p = 0.003) for reader 1, and 1835-1895 s/mm2 and 1705-1841 s/mm2 (median, 1872 s/mm2 vs. 1763 s/mm2; p = 0.022) for reader 2, respectively. Interquartile ranges of qualitatively and quantitatively selected optimal b-values were 1735-1873 s/mm2 and 1573-1867 s/mm2 for reader 1, and 1775-1945 s/mm2 and 1591-1955 s/mm2 for reader 2, respectively. Bland-Altman plots consistently demonstrated a mean difference of less than 100 s/mm2 between qualitatively and quantitatively selected optimal b-values. Conclusion: b-value range showing a homogeneous background signal may be optimal for evaluating prostatic index lesions on sDWI. Our qualitative and quantitative data consistently recommend b-values of 1500-2000 s/mm2.

단초점 근용 안경의 수평방향 설계점 결정에 대한 이해 (The Understanding of Determination of Horizontal Centration Point of Single-vision Reading Glasses)

  • 김민호;김현일
    • 한국안광학회지
    • /
    • 제14권2호
    • /
    • pp.1-8
    • /
    • 2009
  • 목적: 본 연구는 서로 다른 기준에 따른 P.D로 제작된 근용 안경을 각각 착용시킨 후에 상대적인 피로 정도를 비교하는 것이 목적이다. 방법: 근용 안경의 굴절력[원용 안경의 굴절력(-)]이 (-)인 사람에게는 원용 P.D와 근용 P.D-B로 제작된 안경을 장용시켜 안정피로 정도를 비교하였고, 근용 안경 굴절력이 (+)[원용 안경 굴절력(+)]인 사람에게는 근용 P.D-B, 원용 P.D, 근용 P.D-A로 조제된 안경을 장용시켜 안정피로 정도를 비교하였다. 근용 P.D-A란 원용 안경의 근거리 시점에서 발생한 기저외방의 프리즘 값과 근용 안경의 시점에서 발생한 프리즘 값이 같도록 감소된 단초점 근용 안경의 중심점간 거리를 의미한다. 결과: 근용 안경의 굴절력[원용 안경 굴절력(-)]이 (-)인 경우에는 원용 P.D로 조제 가공한 경우에 안정피로가 상대적으로 적었다. 근용 안경의 굴절력이 (+)인 경우에는 단정적으로 어떤 설계점 결정방식이 옳다고 확신 할 수는 없지만 데이터 결과에 의할 경우는 근용 P.D-A로 조제 가공한 경우에 상대적으로 더 적은 안정피로를 유발 하였다. 결론: 근용 안경의 굴절력[원용 안경 굴절력(-)]이 (-)인 경우에는 이전의 원용 안경을 착용하고 근거리를 주시한 경우에 근용 주시점에서의 기저내방(Base In)의 효과를 통해 폭주요구량은 감소된다. 따라서 근용 안경(-)은 근거리에서 폭주를 도와준다. 왜냐하면 기저내방의 효과가 원용 안경에 비해 상대적으로 작아졌기 때문이다. 근용 안경의 굴절력[원용 안경 굴절력(+)]이 (+)인 경우에는 상황에 따라 근용 P.D-B, 근용 P.D-A, 원용 P.D를 통해 설계점을 결정 할 수 있다.

  • PDF

안색(顔色)에 대한 현대적 조명 : 상고천진론(上古天眞論)의 여자칠세(女子七歲)이론을 근거로 (The complexion of Korean female changed by 7 years.)

  • 김은주;노호식;김덕희;김한곤;조가영
    • 한방안이비인후피부과학회지
    • /
    • 제23권1호
    • /
    • pp.253-259
    • /
    • 2010
  • Objectives: We investigated $L^*a^*b^*$ and $ITA^{\circ}$ value on the face to correlate the complexion of Korean female with aging theory of Neijing(內經) in Suwen-Shanggutianzhenlun(素問,上古天眞論). Methods: Three hundreds and thirty one Korean females, aged 22-64 years($39.36{\pm}9.71$ years) were participated in this study. We measured the skin properties of the face with Spectrophotometer CM2600d(Minolta, Japan). Trisimulus $L^*a^*b^*$ color and $ITA^{\circ}$ value divided on 7 years were and analyzed by regression analysis method. Results: $L^*$, ITA value decreased and $a^*$, $b^*$ increased as the age increases. Among these, we found out that ITA value is most related to aging. $L^*$ value decreased among the group of 28 to 35 years old. ITA value decreased among the group of 35 to 42 years old. $a^*$ value decreased among the group of 42 to 49 years old. Conclusions: Unique aging pattern by 7 years of female in Oriental medicine is reflected to complexion.

근적외 분광분석법을 이용한 녹차의 색도 분석 (Determination of Color Value (L, a, b) in Green Tea Using Near-Infrared Reflectance Spectroscopy)

  • 이민석;정명근
    • 한국작물학회지
    • /
    • 제53권spc호
    • /
    • pp.108-114
    • /
    • 2008
  • 녹차 품질평가의 한 요인이 되는 색도 평가 시 기존 평가 방법인 육안평가 혹은 색차 분석에 의존하고 있는 현행 분석방법을 신속, 간편하며 재현성이 높고, 녹차 품질관련 기타 성분과 동시분석이 가능한 녹차 색차 분석용 NIRS 검량식을 작성한 결과를 요약하면 다음과 같다. 1. 공시된 녹차 시료를 대상으로 색차계를 이용하여 색도 값(L, a, b)을 조사한 결과 검량식 작성용 시료는 L값이 평균 53.37($48.52{\sim}57.72$), a값이 평균 -7.55($-10.02{\sim}-4.63$), b 값이 평균 18.07($14.00{\sim}22.02$)을 나타내었고, 작성 검량식의 평가용으로 이용된 예견치 분석용 시료와 거의 동일한 범위를 나타내었다. 2. 녹차의 색차 분석용 NIRS 검량식을 검토한 결과 색차 중 명도에 해당하는 L 값은 원시 스펙트럼에 2차 미분(2nd derivative, 8 nm gap, 6 points smoothing, 1 point second smoothing)을 수행한 조건에서 $R^2$ = 0.936으로 가장 우수한 양상을 나타내었고, 적색에 해당되는 색차 a값과 황색에 해당하는 b값은 1차 미분(1st derivative, 4 nm gap, 4 points smoothing, 1 point second smoothing)조건에서 $R^2$가 각각 0.991 및 0.958로 가장 우수한 결과를 나타내었다. 3. 최적의 녹차 색차 분석용으로 작성된 각각의 NIRS 검량식을 미지시료에 적용하여 정확성을 평가한 결과 색도값 L, a 및 b의 결정계수는 각각 0.905, 0.986 및 0.931로 매우 높은 상관을 보였으며, 이들 검량식은 향후 NIRS를 이용한 녹차 관련 연구 및 녹차 산업현장에서 품질관리를 위한 효율적 분석방법으로 활용이 가능할 것으로 판단된다.

Study of Apparent Diffusion Coefficient Changes According to Spinal Disease in MR Diffusion-weighted Image

  • Heo, Yeong-Cheol;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.146-149
    • /
    • 2017
  • In this study, we compared the standardized value of each signal intensity, the apparent diffusion coefficient (ADC) that digitizes the diffusion of water molecules, and the signal to noise ratio (SNR) using b value 0 400, 1400 ($s/mm^2$). From March 2013 to December 2013, patients with suspicion of simple compound fracture and metastatic spine cancer were included in the MR readout. We used a 1.5 Tesla Achieva MRI system and a Syn-Spine Coil. Sequence is a DWI SE-EPI sagittal (diffusion weighted imaging spin echo-echo planar imaging sagittal) image with b-factor ($s/mm^2$) 0, 400, 1400 were used. Data analysis showed ROI (Region of Interest) in diseased area with high SI (signal intensity) in diffusion-weighted image b value 0 ($s/mm^2$) Using the MRIcro program, each SI was calculated with images of b-value 0, 400, and 1400 ($s/mm^2$), ADC map was obtained using Metlab Software with each image of b-value, The ADC is obtained by applying the ROI to the same position. The standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of simple compression fractures were $0.47{\pm}0.04$ and $0.23{\pm}0.03$ and the standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of the metastatic spine were $0.57{\pm}0.07$ and $0.32{\pm}0.08$ And the standardized values of the two diseases were statistically significant (p < 0.05). The ADC ($mm^2/s$) for b value 400 ($s/mm^2$) and 1400 ($s/mm^2$) of the simple compression fracture disease site were $1.70{\pm}0.16$ and $0.93{\pm}0.28$ and $1.24{\pm}0.21$ and $0.80{\pm}0.15$ for the metastatic spine. The ADC ($mm^2/s$) for b value 400($s/mm^2$) was statistically significant (p < 0.05) but the ADC ($mm^2/s$) for b value 1400 (p > 0.05). In conclusion, multi - b value recognition of signal changes in diffusion - weighted imaging is very important for the diagnosis of various spinal diseases.