• Title/Summary/Keyword: $Z_2$

Search Result 7,099, Processing Time 0.048 seconds

Effects of taxol and ionizing radiation on cytotoxicity and prostaglandin production in KB, RPMI-2650, SW-13 and L929 (수종과 암세포주와 섬유모세포주에서 taxol과 전리방사선이 세포독성과 prostaglandin생성에 미치는 영향)

  • Lee Keon-Il;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.127-143
    • /
    • 1998
  • The author evaluated the effects of taxol, a microtubular inhibitor, as a possible radiation sensitizer and the production of prostaglandins on three human cancer cell lines(KB, RPMI-2650 and SW-13) and one murine cell line(L929). Each cell line was divided into four groups (control, taxol only, radiation only and combination of taxol and radiation). The treatment consisted of a single irradiation of 10Gy and graded doses (5, 50, 100, 200, 300, 500 nM) of taxol for a 24-h period. The cytotoxicity of taxol alone was measured at 1 day after(1-day group) and 4 days after(4-day group) the treatment. The survival ratio of cell was analyzed by MTT (3-(4,5-dimethylthiazol-2-yl) -2,5-dimethyl tetrazolium bromide) test. Prostaglandins(PGE2 and PGI2) were measured in the culture medium by a radioimmunoassay. The results obtained were as follows. 1. There was a significantly increased cytotoxicity of KB cells in 4-day group than those in I-day group. There was a high correlation between doses of taxol and cell viability in both groups(l-day group R=0.82741, 4-day group R=0.84655). 2. There was a significantly increased cytotoxicity of RPMI -2650 cells treated with high concentration of taxol in 4-day group than those in I-day group. Also there was a high correlation between doses of taxol and cell viability in 4-day group(R=0.93917). 3. There was a significantly increased cytotoxicity of SW-13 cells treated with high concentration of taxol in 4-day group than those in 1-day group. However no high correlation was observed between doses of taxol and cell viability in both groups(1-day group R=0.46362, 4-day group R=0.65425). 4. There was a significantly increased cytotoxicity of L929 cells treated with low concentration of taxol in 4-day group than those in 1-day group. At the same time, there was a low correlation between doses of taxol and cell viability in both groups(1-day group R=0.34237, 4-day group R=0.23381). 5. In I-day group of L929 cells, higher cytotoxicities were observed in the groups treated with 500 nM taxol than given 10 Gy radiation alone. L929 cells in I-day group alone showed a radiosensitizing effect by taxol.. 6. In addition to L929 cells, all cancer cells treated with a combination of taxol and radiation in 4-day group appeared to have some fragmented nuclei and to float on the medium. In addition, L929 cells appeared to be more confluent. 7. The level of PGE2 production was the highest in the contol KB cells. This appeared to increase in every experimental group of all three cancer cells except L929 cells. There was a significantly increased production of PGE2 in SW -13 cells treated with a combination taxol and radiation compared to the other experimental groups. 8. The level of PGE2 production in the control group of RPMI-Z650 cells was the highest. This appeared to increase in every experimental group of all cells except in SW-13 cells. This also increased significantly in RPMI-2650 cells treated with a combination of taxol and radiation compared to the other experimental groups.

  • PDF

Principle and Recent Advances of Neuroactivation Study (신경 활성화 연구의 원리와 최근 동향)

  • Kang, Eun-Joo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.2
    • /
    • pp.172-180
    • /
    • 2007
  • Among the nuclear medicine imaging methods available today, $H_2^{15}O-PET$ is most widely used by cognitive neuroscientists to examine regional brain function via the measurement of regional cerebral blood flow (rCBF). The short half-life of the radioactively labeled probe, $^{15}O$, often allows repeated measures from the same subjects in many different task conditions. $H_2^{15}O-$ PET, however, has technical limitations relative to other methods of functional neuroimaging, e.g., fMRI, including relatively poor time and spatial resolutions, and, frequently, insufficient statistical power for analysis of individual subjects. However, recent technical developments, such as the 3-D acquisition method provide relatively good image quality with a smaller radioactive dosage, which in turn results in more PET scans from each individual, thus providing sufficient statistical power for the analysis of individual subject's data. Furthermore, the noise free scanner environment $H_2^{15}O$ PET, along with discrete acquisition of data for each task condition, are important advantages of PET over other functional imaging methods regarding studying state-dependent changes in brain activity. This review presents both the limitations and advantages of $^{15}O-PET$, and outlines the design of efficient PET protocols, using examples of recent PET studies both in the normal healthy population, and in the clinical population.

Effects of Growing Density and Cavity Volume of Containers on the Nitrogen Status of Three Deciduous Hardwood Species in the Nursery Stage (용기의 생육밀도와 용적이 활엽수 3수종의 질소 양분 특성에 미치는 영향)

  • Cho, Min Seok;Yang, A-Ram;Hwang, Jaehong;Park, Byung Bae;Park, Gwan Soo
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.2
    • /
    • pp.198-209
    • /
    • 2021
  • This study evaluated the effects of the dimensional characteristics of containers on the nitrogen status of Quercus serrata, Fraxinus rhynchophylla, and Zelkova serrata in the container nursery stage. Seedlings were grown using 16 container types [four growing densities (100, 144, 196, and 256 seedlings/m2) × four cavity volumes (220, 300, 380, and 460 cm3/cavity)]. Two-way ANOVA was performed to test the differences in nitrogen concentration and seedling content among container types. Additionally, we performed multiple regression analyses to correlate container dimensions and nitrogen content. Container types had a strong influence on nitrogen concentration and the content of the seedling species, with a significant interaction effect between growing density and cavity volume. Cavity volumes were positively correlated with the nitrogen content of the three seedling species, whereas growing density negatively affected those of F. rhynchophylla. Further, nutrient vector analysis revealed that the seedling nutrient loading capacities of the three species, such as efficiency and accumulation, were altered because of the different fertilization effects by container types. The optimal ranges of container dimension by each tree species, obtained multiple regression analysis with nitrogen content, were found to be approximately 180-210 seedlings/m2 and 410-460 cm3/cavity for Q. serrata, 100-120 seedlings/m2 and 350-420 cm3/cavity for F. rhynchophylla, and 190-220 seedlings/m2 and 380-430 cm3/cavity for Z. serrata. This study suggests that an adequate type of container will improve seedling quality with higher nutrient loading capacity production in nursery stages and increase seedling growth in plantation stages.

Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer (두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가)

  • Baek, Min Gyu;Kim, Min Woo;Ha, Se Min;Chae, Jong Pyo;Jo, Guang Sub;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: In modern radiotherapy technology, several methods of image guided radiation therapy (IGRT) are used to deliver accurate doses to tumor target locations and normal organs, including CBCT (Cone Beam Computed Tomography) and other devices, ExacTrac System, other than CBCT equipped with linear accelerators. In previous studies comparing the two systems, positional errors were analysed rearwards using Offline-view or evaluated only with a Yaw rotation with the X, Y, and Z axes. In this study, when using CBCT and ExacTrac to perform 6 Degree of the Freedom(DoF) Online IGRT in a treatment center with two equipment, the difference between the set-up calibration values seen in each system, the time taken for patient set-up, and the radiation usefulness of the imaging device is evaluated. Materials and Methods: In order to evaluate the difference between mobile calibrations and exposure radiation dose, the glass dosimetry and Rando Phantom were used for 11 cancer patients with head circumference from March to October 2017 in order to assess the difference between mobile calibrations and the time taken from Set-up to shortly before IGRT. CBCT and ExacTrac System were used for IGRT of all patients. An average of 10 CBCT and ExacTrac images were obtained per patient during the total treatment period, and the difference in 6D Online Automation values between the two systems was calculated within the ROI setting. In this case, the area of interest designation in the image obtained from CBCT was fixed to the same anatomical structure as the image obtained through ExacTrac. The difference in positional values for the six axes (SI, AP, LR; Rotation group: Pitch, Roll, Rtn) between the two systems, the total time taken from patient set-up to just before IGRT, and exposure dose were measured and compared respectively with the RandoPhantom. Results: the set-up error in the phantom and patient was less than 1mm in the translation group and less than 1.5° in the rotation group, and the RMS values of all axes except the Rtn value were less than 1mm and 1°. The time taken to correct the set-up error in each system was an average of 256±47.6sec for IGRT using CBCT and 84±3.5sec for ExacTrac, respectively. Radiation exposure dose by IGRT per treatment was measured at 37 times higher than ExacTrac in CBCT and ExacTrac at 2.468mGy and 0.066mGy at Oral Mucosa among the 7 measurement locations in the head and neck area. Conclusion: Through 6D online automatic positioning between the CBCT and ExacTrac systems, the set-up error was found to be less than 1mm, 1.02°, including the patient's movement (random error), as well as the systematic error of the two systems. This error range is considered to be reasonable when considering that the PTV Margin is 3mm during the head and neck IMRT treatment in the present study. However, considering the changes in target and risk organs due to changes in patient weight during the treatment period, it is considered to be appropriately used in combination with CBCT.

Change of Constituent Components in Selected Korean Chestnut (Castanea crenata S. et Z.) Cultivars by Different Storage Conditions (국내산 밤 일부 품종의 다른 저장 조건들에 의한 성분변화)

  • Kim, Dae-Jung;Chung, Mi-Ja;Seo, Dong-Joo;You, Jin-Kyoun;Shim, Tae-Heum;Choe, Myeon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.2
    • /
    • pp.225-234
    • /
    • 2009
  • The aim of this study was to analyze moisture, crude protein, crude lipid, vitamin C and sugar changes in selected Korean chestnut cultivars such as Danteack, Deabo, Seokchu, Okkwang and Byunggo during storage at $4^{\circ}C$ and $-10^{\circ}C$ for 10 months. The moisture contents of selected Korean chestnut cultivars ranged from 49.9 to 57.4%. The moisture content of Seokchu was the highest. The contents of moisture in white kernel were higher than that in yellow kernel. The content of moisture showed decreasing tendency after 10 months of storage. The crude protein and crude lipid contents in whole kernel of selected Korean chestnut cultivars were $3.3{\sim}4.2%$ and $0.3{\sim}1.6%$, respectively. The crude protein content of Deabo was the highest. The crude protein in Danteack, Seokchu, Okkwang and Byunggo was increased during storage at $4^{\circ}C$ for 10 months, while that in whole kernel of Deabo was decreased and no changes in crude protein in yellow kernels of Deabo were observed. The crude protein in Okkwang was increased during storage at $-10^{\circ}C$ for 10 months. The cold storage was found to have higher composition change of crude protein than the freezing storage. The content of crude lipid in Daebo and Byunggo was decreased during storage at $4^{\circ}C$ and $-10^{\circ}C$. Yellow kernels of Deabo, Okkwang and Byunggo were found to have higher crude lipid content than white kernels. The vitamin C content also decreased during storage at $4^{\circ}C$ and $-10^{\circ}C$ and the decrease in vitamin C content was higher at $4^{\circ}C$ than $-10^{\circ}C$. Vitamin C was not detected after 3 months storage at $-10^{\circ}C$. The sugar content increased at the latter period storage at $4^{\circ}C$ and $-10^{\circ}C$. The sugar content of selected Korean chestnut cultivars ranged from $36.2{\sim}44.3%$ and Dantaek had the highest sugar content.

A Microcomputer-Based Data Acquisition System (Microcomputer를 이용(利用)한 Data Acquisition System에 관(關)한 연구(硏究))

  • Kim, Ki Dae;Kim, Soung Rai
    • Journal of Biosystems Engineering
    • /
    • v.7 no.2
    • /
    • pp.18-29
    • /
    • 1983
  • A low cost and versatile data acquisition system for the field and laboratory use was developed by using a single board microcomputer. Data acquisition system based on a Z80 microprocessor was built, tested and modified to obtain the present functional system. The microcomputer developed consists of 6 kB ROM, 5 kB RAM, 6-seven segment LED display, 16-Hex. key and 8 command key board. And it interfaces with an 8 channel, 12 bits A/D converter, a microprinter, EPROM programmer for 2716, and RS232C interface to transfer data between the system and HP3000 mini-computer manufactured by Hewlett Packard Co., A software package was also developed, tested, and modified for the system. This package included drivers for the AID converter, LED display, key board, microprinter, EPROM programmer, and RS232c interface. All of these programs were written in 280 assembler language and converted to machine codes using a cross assembler by HP3000 computer to the system during modifying stage by data transferring unit of this system, then the machine language wrote to the EPROM by this EPROM programmer. The results are summarized as follows: 1. Measuring program developed was able to control the measuring intervals, No. of channels used, and No. of data, where the maximum measuring speed was 58.8 microsec. 2. Calibration of the system was performed with triangle wave generated by a function generator. The results of calibration agreed well to the test results. 3. The measured data was able to be written into EPROM, then the EPROM data was compared with original data. It took only 75 sec. for the developed program to write the data of 2 kB the EPROM. 4. For the slow speed measurements, microprinter instead of EPROM programmer proved to be useful. It took about 15 min. for microprinter to write the data of 2 kB. 5. Modified data transferring unit was very effective in communicating between the system and HP3000 computer. The required time for data transferring was only 1~2 min. 6. By using DC/DC converting devices such as 78-series, 79-series. and TL497 IC, this system was modified to convert the only one input power sources to the various powers. The available power sources of the system was DC 7~25 V and 1.8 A.

  • PDF

Growth of $LiTaO_3$ and Fe doped-LiTaO3 single crystal as holographic storage material (홀로그래피 소자재료 $LiTaO_3$단결정 성장)

  • 김병국;윤종규
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.2
    • /
    • pp.193-204
    • /
    • 1998
  • The single crystal of the $LiTaO_3$has large electro-optic effects, so it is applied to optical switch, acousto-optic deflector, and optical memory device as hologram using photorefractive effect. In this study, optic-grade undoped $LiTaO_3$and Fe:LiTaO$LiTaO_3$single crystals were grown by the Czochralski method and optical transmission and absorption spectrums were measured in the wavelength of UV-VIS range. The curie temperature was determined with DSC and by measuring capacitance for the grown undoped crystal and ceramic powder samples of various Li/Ta ratio. In case of having a 48.6 mol% $Li_2O$ as a starting Li/Ta ratio, the results of concentration variations were below 0.01 mol% $Li_2O$ all over the crystal, so it was confirmed that $LiTaO_3$single crystals were grown under congruent melting composition having optical homogeneity. The curie temperature of the Fe:$LiTaO_3$crystal was increased with increased with increased doped Fe concentrations;by the ratio of $7.5^{\circ}C$ increase per Fe 0.1 wt%. Also, the optical transmittance was about 78 %, which was sufficient for optical device.

  • PDF

EFFECT OF ULTRASONIC VIBRATION ON ENAMEL AND DENTIN BOND STRENGTH AND RESIN INFILTRATION IN ALL-IN-ONE ADHESIVE SYSTEMS (All-in-one 접착제에서 초음파진동이 법랑질과 상아질의 결합강도와 레진침투에 미치는 영향)

  • Lee, Bum-Eui;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.66-78
    • /
    • 2004
  • The objective of this study was to apply the vibration technique to reduce the viscosity of bonding adhesives and thereby compare the bond strength and resin penetration in enamel and dentin achieved with those gained using the conventional technique and vibration technique. For enamel specimens, thirty teeth were sectioned mesio-distally. Sectioned two parts were assigned to same adhesive system but different treatment(vibration vs. non-vibration). Each specimen was embedded in 1-inch inner diameter PVC pipe with a acrylic resin. The buccal and lingual surfaces were placed so that the tooth and the embedding medium were at the same level. The samples were subsequently polished silicon carbide abrasive papers. Each adhesive system was applied according to its manufacture's instruction. Vibration groups were additionally vibrated for 15 seconds before curing. For dentin specimen, except removing the coronal part and placing occlusal surface at the mold level, the remaining procedures were same as enamel specimen. Resin composite(Z250. 3M. U.S.A.) was condensed on to the prepared surface in two increments using a mold kit(Ultradent Inc., U.S.A.). Each increments was light cured for 40 seconds. After 24 hours in tap water at room temperature, the specimens were thermocycled for 1000cycles. Shear bond strengths were measured with a universal testing machine(Instron 4465, England). To investigate infiltration patterns of adhesive materials, the surface of specimens was examined with scanning electron microscope. The results were as follows: 1. In enamel the mean values of shear bond strengths in vibration groups(group 2, 4, 6) were greater than those of non-vibration group(group 1, 3, 5). The differences were statistically significant except AQ bond group. 2. In dentin, the mean values of shear bond strengths in vibration groups(group 2, 4, 6) were greater than those of non-vibration groups(group 1, 3, 5). But the differences were not statistically significant except One-Up Bond F group. 3. The vibration group showed more mineral loss in enamel and longer resin tag and greater number of lateral branches in dentin under SEM examination.

  • PDF

Behavior of amber fish, Seriola aureovittata released in the setnet (정치망내에 방류한 부시리, Seriola aureovittata 의 행동)

  • 신현옥;이주희
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.2
    • /
    • pp.161-169
    • /
    • 1999
  • This paper describes the swimming and escaping behavior of amber fish, Seriola aureovittata released in the first bag net of the setnet and observed with telemetry techniques. The setnet used in experiment is composed of a leader, a fish court with a flying net and two bag nets having ramp net. The behavior of the fish attached an ultrasonic depth pinger of 50 KHz is observed using a prototype LBL fish tracking system. The 3-D underwater position ofthe fish is calculated by hyperbolic method with three channels of receiver and the depth of pinger. The results obtained are as follows: 1. The fish released on the sea surface was escaped down to 15 m depth and rised up to near the sea surface during 5 minutes after release. The average swimming speed of the fish during this time was 0.87 m/sec. 2. The swimming speed of the fish is decreased slowly in relation to the time elapsed and the fish showed some escaping behavior forward to the fish court staying 1 to 7 m depth layer near the ramp net. The average speed of the fish during this time was 0.52 m/sec. 3. During 25 minutes after beginning of hauling net, the fish showed a faster swimming speed than before hauling and an escaping behavior repeatedly from the first ramp net to the second one in horizontal. In vertical, the fish moved up and down between the sea surface and 20 m depth. After this time, the fish showed the escaping behavior forward to fish court after come back to the first ramp net in spite of the hauling was continued. It is found that the fish was escaped from the first ramp net to the fish court while the hauling was carried out. The average speed of the fish after beginning of hauling was 0.72 m/sec which increased 38.5 % than right before the hauling and showed 0.44 to 0.82 m/see of speed till escaping the first bag net. The average swimming speed during observation was 0.67 m/sec (2.2 times of body length).

  • PDF

THE EFFECT OF OXYGEN INHIBITION ON INTERFACIAL BONDING BETWEEN COMPOSITE RESIN LAYERS (복합레진 적층계면에서 oxygen inhibition의 영향에 관한 연구)

  • Choi, Su-Mi;Park, Jae-Hong;Choi, Sung-Chul;Kim, Kwang-Chul;Choi, Young-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.3
    • /
    • pp.298-307
    • /
    • 2010
  • The purpose of this study was to assess the effect on oxygen inhibition layer(OIL) for the interfacial bonding between resin composite layers, including shear bond strength, fracture modes and degree of conversion. The first layer of specimen was filled with Z-250(shade A3) and was cured for 40s. The second layer of specimen was filled with same composite(shade A1) and was cured for 40s. The first layer of specimens for each group were prepared by methods as followings. Control(curing in atmospheric air), Group1(curing against Mylar strip), Group2(scrubbed with a acetone-soaked cotton), Group3(using Tescera light cup), Group4(using Tescera heat cup), Group5(stored in disti1led water for 30days at $37^{\circ}C$), Group6 (using bonding agent). The results were as follows: 1. There was no statistically significant different shear bond strength between control and group 1(p>0.05). 2. Group 2 showed significantly lower shear bond strength than control and group 1(p<0.05). 3. The observation of the fracture surface leads to the evidence that a major difference occurs in the case of control, group1 and group 3 samples which break mainly cohesively while the other groups break in majority adhesively. 4. The results of FTIR showed that the degree of conversion was the highest in group 2 and the lowest in control group(p<0.05). It can be concluded that an OIL is not necessary for bonding with composite resin. But if a reduced critical amount of the unreacted monomer is present, it was detrimental to bonding additional layers of composite. Further study, such as the quantitative analysis of the unreacted monomer are required.