• Title/Summary/Keyword: $V_s$값

Search Result 929, Processing Time 0.025 seconds

Electrochemistry for Redox Polymer Film of N,N'-bis(3-pyrrol-1-yl-propyl)-4,4'-bipyridinium Ion (N,N'-bis(3-pyrrol-1-yl-propyl)-4,4'-bipyridinium이온의 산화-환원 고분자 피막에 대한 전기화학)

  • Cha, Seong-Keuck
    • Polymer(Korea)
    • /
    • v.25 no.1
    • /
    • pp.6-14
    • /
    • 2001
  • The monomer N,N'-bis(3-pyrrol-1-yl-propyl)-4,4'-bipyridinium$(PF_6)_2$ was electrochemically polymerized on glassy carbon electrode surface. This polymer film electrode has electroactive sites on its bipyridinium ions distributed at the polymer strands. The formal potentials of the electrodes were -0.41V and -0.81V(vs. SSCE) for each step at phosphate buffer(pH=5.70). The diffusion coefficients of the dopants ions into the polymer matrix were $1.57{\times}10^{-4}$ and $4.35{\times}10^{-5}cm^2s^{-1}$ for first and second redox couple, respectively. The rate constants of electron transfer at $V^{2+/+}$ of the first step was a $57.53s^{-1}$, which was 22 times higher than $V^{+/0}$ one having $2.63s^{-1}$ in the solution. The charge transfer resistance of the polymer film was influenced by the dopant ion of the electrolyte. Thus the resistances were 22.63, 16.81, 12.44 and $11.36k{\Omega}$ for $LiClO_4,\;NaClO_4,\;KClO_4$, and phosphate buffer, respectively. The reaction order of the electropolymerization was first order and the rate constant of the polymerization was $1.31{\times}10^{-1}s^{-1}$ as determined by EQCM method. The G.C./p-BPB type electrode doped with phosphate ions showed a stability and reproducibility in CV procedure over 20 cycles.

  • PDF

Evaluation of Required Discharge Capacity for Prefabricated Vertical Drains (연직배수재의 소요통수능 평가)

  • 김상규;김현태;공길용
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.1
    • /
    • pp.35-45
    • /
    • 2001
  • Bergado에 의해 비교 분석된 많은 연구자들의 배수재의 소요통수능에 대한 제안값을 보면 0.32~50cc/s로 그 차이가 너무 크기 때문에 실무에 적용하기가 어렵다. 본 연구에서는 배수재의 통수능변화를 고려할 수 있는 압밀해석방법을 개발하고, 흙의 압밀계수, 압축지수, 배수재 타설심도 및 타설후 시간경과에 따른 배수재의 통수능 감소 등의 현장여건을 고려한 압밀해석을 통하여 압밀지연을 일으키지 않는 배수재의 소요통수능에 대한 기준을 제시하였다. 압밀해석결과 어느값 이상의 통수능에서는 압밀지연이 없으므로 이 값 이상의 통수능을 갖는 배수재를 선택하는 것이 중요하며, 압밀지연시간 5% 이내인 배수재의 소요통수능은 압밀계수($c_{v}$ ), 배수재의 길이(L) 및 압축지수($C_{c}$)와 비례관계로서 안전율 1.5를 고려하여 $q_{wa}$ =8$\times$($c_{v}$ $\times$L$\times$$C_{c}$)(cc/s) 이상이면 되는 상관식을 얻었다. 이 값 이상의 배수재를 선택하는 경우는 연직배수공법의 압밀해석에서 배수재의 통수능을 고려하지 않아도 된다는 결론을 얻었다.

  • PDF

이온주입 에너지에 따른 Auger Si KLL Peak Shift 및 Ti 계열 화합물의 Chemical State 관찰

  • Heo, Sung;Park, Yoon-Baek;Min, Gyung-Yeol;Lee, Sun-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.83-83
    • /
    • 1999
  • 본 연구에서는 Auger Elecrtron Spectroscopy (AES) 장비를 이용하여 Silicone Wafer 표면에 BF 이온을 주입시킨 후 Dopping 농도 및 Implantation 에너지에 따른 Si KLL Peak의 변화를 관찰하였다. 또한 PVD Ti 계열 화학물의 시료에 대하여 Peak의 Shape 변화를 관찰하였다. 1)Dopping 농도 및 Implantation 에너지에 따른 Si KLL Peak의 변화 관찰 일반적으로 Silicone 기판에 Arsenic(3가)을 Dopping 하였을 경우, Si KLL Peak의 Kinetic Energy 값은 순수 Si Peak보다 더 작은 값으로 Shift 하며, Boron (5가)을 Dopping하였을 경우에는 더 큰 값으로 Shift 한다. 이론적으로 N-type Si의 에너지 차이는 약 1.0eV로 보고되어 있으며, AES를 이용하여 실험적으로 측정된 값은 약 0.6eV정도로 알려져 있다. 이러한 차이는 Dopping 농도에 따라 Valance Band의 에너지 값이 변화하기 때문이라고 알려져 있다. 본 연구에서는 BF2를 Si에 이온 주입하여 입사 에너지 및 dose 량에 따른 Si KLL Peak의 변화를 관찰하였다. 그림1과 같이 Si KLL Peak는 Implantation Energy가 작을수록 Kinetic Energy가 높은 곳으로 Shift 한다. 이는 LOw Energy로 이온 주입하면, Projected Range (Rp)가 High Energy로 이온 주입할 때보다 작기 때문이며, 이 결과를 Secondary Ion Mass Spectroscopy (SIMS) 및 TRIM simulation을 이용하여 확인하였다. 또한 표면에서의 전자 Density의 변화와 Implantation energy와의 관계를 시료의 표면에서 반사되어 나오는 전자의 에너지 손실(Reflected Electron Energy Loss Spectroscopy:REELS)을 통하여 고찰하였다. 2) PVD Ti 계열화합물의 시료에 대한 peak의 shape 가 변화하며, TiL3M23V (Ti2) 및 TiL3M23M23 (Til) Peak의 Intensity Ratio가 변화한다. 따라서 본 연구에서는 그림 2와 같이 Ti 결합 화합물에서의 Ti Auger Peak의 특성 에너지 값과 Peak Shape를 관찰하여, AES를 이용하여 Ti 계열의 화합물에 대한 Chemical state 분석의 가능성을 평가하였다.

  • PDF

Analysis of Output Constancy Checks Using Process Control Techniques in Linear Accelerators (선형가속기의 출력 특성에 대한 공정능력과 공정가능성을 이용한 통계적 분석)

  • Oh, Se An;Yea, Ji Woon;Kim, Sang Won;Lee, Rena;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.185-192
    • /
    • 2014
  • The purpose of this study is to evaluate the results for the quality assurance through a statistical analysis on the output characteristics of linear accelerators belonging to Yeungnam University Medical Center by using the Shewhart-type chart, Exponentially weighted moving average chart (EWMA) chart, and process capability indices $C_p$ and $C_{pk}$. To achieve this, we used the output values measured using respective treatment devices (21EX, 21EX-S, and Novalis Tx) by medical physicists every month from September, 2012 to April, 2014. The output characteristics of treatment devices followed the IAEA TRS-398 guidelines, and the measurements included photon beams of 6 MV, 10 MV, and 15 MV and electron beams of 4 MeV, 6 MeV, 9 MeV, 12 MeV, 16MeV, and 20 MeV. The statistical analysis was done for the output characteristics measured, and was corrected every month. The width of control limit of weighting factors and measurement values were calculated as ${\lambda}=0.10$ and L=2.703, respectively; and the process capability indices $C_p$ and $C_{pk}$ were greater than or equal to 1 for all energies of the linear accelerators (21EX, 21EX-S, and Novalis Tx). Measured values of output doses with drastic and minor changes were found through the Shewhart-type chart and EWMA chart, respectively. The process capability indices $C_p$ and $C_{pk}$ of the treatment devices in our institution were, respectively, 2.384 and 2.136 for 21EX, 1.917 and 1.682 for 21EX-S, and 2.895 and 2.473 for Novalis Tx, proving that Novalis Tx has the most stable and accurate output characteristics.

Analysis of Arsenic(III) by the Cathodic Stripping Voltammetry (음극 벗김 전류법을 이용한 비소(III) 분석에 관한 연구)

  • Yun, Young Ja;Lee, Hyung Sook;Ko, Weon Bae;Kim, Chung Hee
    • Analytical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.417-423
    • /
    • 1992
  • The effects of metal ions on the arsenic(III) stripping peak were examined by the cathodic stripping voltammetry. The reduction stripping peak potential and current of arsenic(III) value were -0.79V(vs. Ag/AgCl). $0.86{\mu}A$ by using 0.1N-hydrochloric acid solution. When 10 times of Cu(II) was added to the solution, the reduction stripping peak potential of arsenic(III) was the value of -0.84V(vs. Ag/Cl), which showed a good agreement with theoretical value -0.84V(vs. Ag/Cl) by using 0.1N hydrochloric acid solution. Lead(II) and copper(II) increased the stripping peak heigh of arsenic(III), Among them, the copper(II) extremely enhanced it.

  • PDF

A comprehensive comparison of IMRT and VMAT plan quality for orbital lymphoma (안와 림프종 환자의 방사선치료를 위한 세기조절방사선치료와 용적세기조절회전치료의 전산화 치료계획에 대한 고찰)

  • Yoo, Soon Mi;Ban, Tae Joon;Yun, In Ha;Baek, Geum Mun;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.281-287
    • /
    • 2014
  • Purpose : The purpose of this study is to compare the plan quality of volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) for the treatment of orbital lymphoma. IMRT, partial single arc(SA) and partial-double arc(DA) VMAT plans for four patients with orbital lymphoma treated at our institution were used for this study. Conformity Index(CI), Paddick's Conformity Index(PCI) and Homogeneity Index(HI) of planning target volume(PTV) were used to evaluate dosimetric quality of each plan. The Monitor Unit (MU), treatment time and dose of ipsilateral lens from each type of plan were measured for comparison. Materials and Methods : The CI of PTV for IMRT, SA and DA were measured as 0.88, 0.86, 0.92. The PCI of DA was the lowest as 1.33. Also HI of DA was the lowest in measured plans as 1.15. Mean dose of lens, lacrimal gland, optic chiasm, the opposite optic nerve and both orbit was analyzed with V30, V20, V10, V5. The result showed that the lowest dose in IMRT highest in SA in opposite lens, lacrimal gland, optic nerve, orbit. Results : Treatment time and average MU of IMRT was about three times higher than SA. Conclusion : Considering the superior plan quality as well as the delivery efficiency of VMAT compared with that of IMRT, VMAT may be the preferred modality for treating orbital lymphoma.

The Effect of Pressure on the Electrophilic Substitution Reaction of Tetramethyltin with Iodine (Tetramethyltin과 Iodine의 친전자 치환반응에 대한 압력의 영향)

  • Kwun Oh Cheun;Lee Young Hoon
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.6
    • /
    • pp.555-561
    • /
    • 1993
  • Ultraviolet spectrophotometric investigation has been carried out on the system of iododestannylation iodine and tetramethyltin in methanol. The transient CT absorption spectrum can be observed and the subsequent disappearance of CT absorption spectrum was accompained by the cleavage of tetramethyltin with iodine. From there, the rate constants for the iododestannylation were determined at 10, 25 and 35$^{\circ}C$ up to 1600 bar and the reaction rates were increased with increasing temperature and pressure. From these rate constants, the values of the activation parameters (${\Delta}V^\neq,\;{\Delta}{\beta}^{\neq},\;{\Delta}H^{\neq},\;{\Delta}S^{\neq}\;and\;{\Delta}G^{\neq}$) were obtained. The activation volumes and activation compressibility coefficients were both negativity. The activation enthalpies were positive and activation entropies had large negative values. From these values discussed in terms of solvent structure variation of transition state and mechanism. From these results, it was found that the reaction is followed with $S_E2$ mechaenism and weakened $S_E2$ mechanism nature by increasing pressure.

  • PDF

Kinetic Analysis by High Pressure and High Vacuum Apparatus for the Nucleophilic Substitution Reaction (고압 및 고진공장치를 이용한 친핵성치환반응에 대한 속도론적 분석)

  • Kim, Se-Kyong
    • Analytical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.375-380
    • /
    • 2004
  • Kinetics have been studied by high vacuum and high pressure apparatus under various temperatures and pressures for the nucleophilic substitution reaction. Rate constants, activated parameters and Hammett ${\rho}$-values are determined. The values of ${\Delta}V^{\ddag}$, ${\Delta}{\beta}^{\ddag}$ and ${\Delta}S^{\ddag}$ are all negative. The Hammett ${\rho}$-values are negative for the nucleophile (${\rho}x$) over the pressure range studied. Consequently the rate constant increases as the pressure increases, and some decrease in vacuum. So these reactions proceed in typical $S_N2$ reaction mechanism.

Nucleophile Effects for the Reactions of Nucleophilic Substitution by Pressure and Temperature (친핵성치환반응에서 압력과 온도변화에 따른 친핵체 효과)

  • Kim, Se-Kyong;Choi, Sung-Yong;Ko, Young-Shin
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.5
    • /
    • pp.461-466
    • /
    • 2004
  • Kinetics for the nucleophiles have been studied under high vacuum and high pressures in various temperatures. Pseudo-first order rate constants, second order rate constants, thermodynamic parameters and Hammett ${\rho}$-values are determined. The values of ${\Delta}V^{\neq},\;{\Delta}{\beta}^{\neq}\;and\;{\Delta}S^{\neq}$are all negative. The Hammett r-values are negative for the nucleophile (${\rho}$x) over the pressure range studied. The results of kinetic studies for pressure and nucleophilet show that these reactions proceed in typical $S_N2$ reaction mechanism and change of mechanism.

Modified Theory of Significant Liquid Structure (H. Eyring의 액체구조 이론에 대한 새로운 고찰)

  • Chang, Sei-Hun;Park, Hyung-Suk;Paik, Woon-Kie;Park, Sung-Hye;John, Mu-Shik;Ahn, Woon-Sun
    • Journal of the Korean Chemical Society
    • /
    • v.8 no.1
    • /
    • pp.33-38
    • /
    • 1964
  • 최근에 H.Eyring과 그의 공동연구자들은 "Significant liquid theory"를 제안하여 여러가지 액체에 대하여 잘 적용됨을 보여주고 있다$^{(3)-(12)}$. 그들은 고체와 액체 내부의 고체상 분자는 하나의 연속된 상을 이룬다고 보고 고체의 몰부피 $V_s$는 같다고 보았으나 Einstein특성온도 ${\theta}$나 승화열 $E_s$ 등은 서로 다른 값을 취하지 않으면 않되었을 뿐더러 가장 안정한 분자주위에 모여 올수 있는 자리수 n가 12보다 크게 되는 등의 실제적으로 생각하기 어려운 결과를 내놓았다. 그러나 우리는 고체상의 분자의 액체내부의 고체상분자와는 일반적으로 서로 다른 상태를 이루고 있으리라는 생각을 하여 액체가 존재하는 가장 낮은 온도 즉 삼중점을 액체의 기저상태로 보고 이점에서 parameter들을 정하였다. 이와같이 하여 정한 $V_s$는 고체의 경우보다 약간 크고 ${\theta}$$E_s$는 약간 작은 값이 나타나게 되었고 n도 12보다 작은 값이 나왔다. 이것은 실제적으로 매우 타당한 결과이며 또 이들을 써서 여러가지 열역학적인 양을 계산한 결과는 우리가 취급한 모든 물질들에 대해여 실측치와 좋은 일치를 보여주고 있다.

  • PDF