• 제목/요약/키워드: $SF_6/CO_2$

검색결과 100건 처리시간 0.027초

SF6/N2 혼합기체의 DC 플라즈마 특성 분석 (The Analysis of DC Plasmas Characteristics on SFSF6 and N2 Mixture Gases)

  • 소순열
    • 전기학회논문지
    • /
    • 제63권10호
    • /
    • pp.1485-1490
    • /
    • 2014
  • $SF_6$ gas has been used for power transformers or gas insulated switchgears, because it has the superior insulation property and the stable structure chemically. It has been, however, one of global warming gases and required to reduce the its amount. Some papers have reported that its amount could be reduced by mixing with other gases, such as $N_2$, $CF_4$, $CO_2$ and $C_4F_8$ and their mixture gases would cause the synergy effect. In this paper, we investigated the characteristics of DC plasmas on $SF_6$ mixture gases with $N_2$ at atmospheric pressure. $N_2$ gas is one of cheap gases and has been reported to show the synergy effect with mixing $SF_6$ gas, even though $N_2$ plasmas have electron-positive characteristics. 38 kinds of $SF_6/N_2$ plasma particles, which consisted of an electron, two positive ions, five negative ions, 30 excitation and vibration particles, were considered in a one dimensional fluid simulation model with capacitively coupled plasma chamber. The results showed that the joule heating of $SF_6/N_2$ plasmas was mainly caused by positive ions, on the other hand electrons acted on holding the $SF_6/N_2$ plasmas stably. The joule heating was strongly generated near the electrodes, which caused the increase of neutral gas temperature within the chamber. The more $N_2$ mixed-ratio increased, the less joule heating was. And the power consumptions by electron and positive ions increased with the increase of $N_2$ mixed-ratio.

7.2kV급 로타리아크 소호방식을 이용한 $SF_6$가스 전자접촉기의 차단특성 (Interrupting Performance of 7.2kV $SF_6$ Gas Electromagnetic Contactor Using Rotary Arc Principle)

  • 장기찬;정진교;신영준;김진기;김귀식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.77-79
    • /
    • 1996
  • The model interrupters of $SF_6$ gas electromagnetic contactor whose ratings are 7.2kV, 4.0kA have been designed and manufactured on the basis of theoretical and computational analysis for its development. The eddy current analysis, the magnetic field analysis and the calculation of the rotational force on arcs have been conducted using FLUX2D package. The short circuit current interrupting tests have been conducted for the model interrupters using the simplified synthetic testing facility in KERI. The results show that the model interrupters have sufficient interrupting capability and the new design concept is prefer for good interrupting performance.

  • PDF

7.2kV급 로타리아크 소호방식을 이용한 $SF_6$가스 전자접촉기 개발연구 (Development of 7.2kV $SF_6$ Gas Electromagnetic Contactor Using Rotary Arc Method)

  • 장기찬;정진교;신영준;김귀식;김진기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.330-332
    • /
    • 1997
  • In this paper, a development of the 7.2kV class $SF_6$ gas electromagnetic contactor which is used a rotary-arc principle in interrupting method is presented. A prototype contactor is made. In the interrupting small current permanent-magnet is used and in the interrupting high current the coil through which arc current itself flows is used. Successfully the prototype contactor carrys out the making, the braking and short time test.

  • PDF

$SF_6$가스 회수 공정들의 특성 연구 (Characteristics of $SF_6$ Gas Recycling Processes)

  • 조훈;우대식;최유미;한명완
    • 청정기술
    • /
    • 제17권4호
    • /
    • pp.329-335
    • /
    • 2011
  • $SF_6$가스는 지구 온난화 가스로 알려져 있다. $SF_6$가스의 지구온난화 기능은 이산화탄소에 비하여 22,000배 이다. $SF_6$가스 회수기술은 환경 및 경제적 측면에서 주요한 기술이다. 본 연구에서는 $SF_6$가스를 현장에서 용이하게 회수할 수 있는 여러 공정들로서 액화공정, 결정화 공정, 증류 공정에 대하여 연구하였다. 이들 공정들을 Aspen plus를 이용하여 공정 모사 및 최적화를 행하였다. 제품의 규격과 회수율을 만족하면서 에너지 소모량을 최소화하도록 최적화 문제를 구성하였다. 이 최적화 결과들을 바탕으로 공정성능들을 비교하였다. 각 공정변수들이 공정 성능에 미치는 영향을 조사하였고, 제품의 순도와 회수율의 변화에 따른 최적 조업조건의 변화를 살펴보았다.

0.7wt% CaO 첨가 AZ91D Eco-Mg 다이캐스팅 부품의 미세조직 및 기계적 특성 (Microstructures and Mechanical Properties of Diecast 0.7wt% CaO added Eco-Mg Parts)

  • 서정호;임현규;김세광
    • 한국주조공학회지
    • /
    • 제30권6호
    • /
    • pp.224-230
    • /
    • 2010
  • To prevent oxidation of Mg melt, $SF_6$ gas has been generally used for Mg alloys during melting and casting as a cover gas. The use of $SF_6$ gas, however, will be restricted owing to its crucial impact on global warming. Non-$SF_6$ process during melting and casting in diecasting industry has been proved with Eco-Mg alloys by a simple addition of small amount of CaO into Mg alloys. This paper shows non-$SF_6$ diecasting procedures for 0.7wt% CaO added AZ91D Eco-Mg alloys. Cold-chamber diecasting was performed under $CO_2$ atmosphere without $SF_6$ gas. An increment of mechanical properties, especially strength and ductility of Eco-Mg alloys is, in part, due to high-quality melt, refined grain size and $Al_2Ca$ second phase strengthening. Microstructures and mechanical properties of 0.7wt% CaO added AZ91D Eco-Mg alloys are evaluated in comparison with those of conventional AZ91D Mg alloy.

25.8kV $SF_6$가스절연 스위치기어(GIS)를 대체한 친환경 고체절연 스위치기어(SIS) 개발 (Development of the replaced Eco-friendly SIS with GIS for 25.8kV class)

  • 마지훈;정맹뢰;유련;원성연;이석원;김영근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1219_1220
    • /
    • 2009
  • In recent years, the companies of electric power equipment for MV, HV class trend to develop that the eco-friendly insulated(solid, eco-gas, air etc.) switchgear replace with existent SF6 gas insulated switchgear by environmental problems such as global warming and soon. This paper introduces the Solid Insulated Switchgear(SIS) which is the epoxy of eco-friendly insulation material. The characteristic of SIS to introduce in this paper is as following. 1) Eco-friendly. (SF6 gas free) 2) The structure of flexible system. (Expansion) 3) The optimum design. (The Analysis of electrical & mechanical) 4) An Interface treatment between epoxy and insert. (Molding technology) This paper described about some technology for development of SIS.

  • PDF

SF6/CO2혼합기체 중에서 뇌임펄스코로나방전의 특성 (Characteristics of lightning Impulse Corona Discharges in SF6/CO2 Mixtures)

  • 이복희;백영환;오성균;안창환
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.85-90
    • /
    • 2006
  • 본 논문은 불평등 전계의 $SF_6/CO_2$혼합기체 중에서 전구방전특성에 대한 실험결과를 제시한다. 임펄스 전구방전 진전을 코로나 전류와 방전광 이미지의 측정으로 조사하였다. 정 부극성의 전구방전 진전메커니즘은 기본적으로 같았으며, 초기스트리머코로나는 침전극의 끝단에서 발단되어 계단상으로 진전하는 리더에 의해 시험갭을 교락시킨다. 정극성에서 리더펄스의 휴지시간은 부극성에서보다 매우 짧았다. 또한 부극성에서 초기스트리머코로나와 절연파괴사이의 시간간격은 정극성에서보다 매우 길게 나타났다. 정극성에서 방전채널경로는 임의적으로 나타났으며, 부극성에서 리더 채널은 정극성에서 보다 굵고 밝게 나타났다.

Analysis on Temperature Distribution and Current-Carrying Capacity of GIL Filled with Fluoronitriles-CO2 Gas Mixture

  • Chen, Geng;Tu, Youping;Wang, Cong;Cheng, Yi;Jiang, Han;Zhou, Hongyang;Jin, Hua
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2402-2411
    • /
    • 2018
  • Fluoronitriles-$CO_2$ gas mixtures are promising alternatives to $SF_6$ in environmentally-friendly gas-insulated transmission lines (GILs). Insulating gas heat transfer characteristics are of major significance for the current-carrying capacity design and operational state monitoring of GILs. In this paper, a three-dimensional calculation model was established for a GIL using the thermal-fluid coupled finite element method. The calculated results showed close agreement with experimentally measured data. The temperature distribution of a GIL filled with the Fluoronitriles-$CO_2$ mixture was obtained and compared with those of GILs filled with $CO_2$ and $SF_6$. Furthermore, the effects of the mixture ratio of the component gases and the gas pressure on the temperature rise and current-carrying capacity of the GIL were analyzed. Results indicated that the heat transfer performance of the Fluoronitriles-$CO_2$ gas mixture was better than that of $CO_2$ but worse than that of $SF_6$. When compared with $SF_6$, use of the Fluoronitriles-$CO_2$ gas mixture caused a reduction in the GIL's current-carrying capacity. In addition, increasing the Fluoronitriles gas component ratio or increasing the pressure of the insulating gas mixture could improve the heat dissipation and current-carrying capacity of the GIL. These research results can be used to design environmentally-friendly GILs containing Fluoronitriles-$CO_2$ gas mixtures.

불평등전장에서 $SF_6/CO_2$ 혼합기체의 뇌임펄스 전구방전특성 (Characteristics of lightning impulse preliminary breakdown discharge under non-uniform electric field in $SF_6/CO_2$ mixtures)

  • 이복희;오성균;백영환;안창환;전덕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2140-2142
    • /
    • 2005
  • This paper presents the experimental results on the preliminary breakdown characteristics under a highly non-uniform electric field in $SF_6/CO_2$ gas mixtures. The impulse preliminary breakdown developments are investigated by the measurements of corona current and light emission images. As a result, the preliminary breakdown development mechanisms for both positive and negative polarities are same. The first streamer corona is initiated at the tip of needle electrode, and the leaders develop with a stepwise propagation and bridge the test gap. The pause time of leader pulses in the positive polarity is significantly shorter than that in the negative polarity. Also, the time interval between the first streamer corona onset and breakdown in the negative polarity was much longer than that in the positive polarity The discharge channel paths in the positive polarity were zigzag. On the other hands, the leader channel in the negative polarity was thicker than that in the positive polarity.

  • PDF

Comparative Characterization of Growth and Recombinant Protein Production among Three Insect Cell Lines with Four Kinds of Serum Free media

  • Kwon, Mi-Sun;Takashi Dojima;Park, Enoch Y.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제8권2호
    • /
    • pp.142-146
    • /
    • 2003
  • Three insect cell lines, Sf9, Sf21 and Tn5Bl-4, and four different kinds of serum free media (SFM), Sf 900 II, EX-CELL 420, EX-CELL 405 and Express Five, were used to compare the nutrient consumption, byproduct formation, production of recombinant protein and protease activity in suspension cultures. The Sf 900 II SFM was a ppropriate for the cell growth and protein production of the Sf9 and Sf21 cell lines. When the Tn5Bl-4 cell line was grown in the Express Five SFM, the specific growth rate was 1.6 fold higher than those of either the Sf9 or Sf21 cell lines. The glucose and glutamine consumption rates per cells, were 4 and 2.3 times higher than those of the Sf9 cell line, respectively. The overall yield coefficients of the lactate and ammoniumion were 2.8 and 1.5 times higher compared to those of the Sf9 cell line. respectively. The maximum specific ${\beta}$-galactosidase production rate was 4.5 fold that of the Sf9 cell line, a 3 times higher protease activity per cell.