• Title/Summary/Keyword: $O_2$ Sensor

Search Result 1,272, Processing Time 0.036 seconds

Measurement of Sulfur Dioxide Concentration Using Wavelength Modulation Spectroscopy With Optical Multi-Absorption Signals at 7.6 µm Wavelength Region (7.6 µm 파장 영역의 다중 광 흡수 신호 파장 변조 분광법을 이용한 이산화황 농도 측정)

  • Song, Aran;Jeong, Nakwon;Bae, Sungwoo;Hwang, Jungho;Lee, Changyeop;Kim, Daehae
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.293-303
    • /
    • 2020
  • According to the World Health Organization (WHO), air pollution is a typical health hazard, resulting in about 7 million premature deaths each year. Sulfur dioxide (SO2) is one of the major air pollutants, and the combustion process with sulfur-containing fuels generates it. Measuring SO2 generation in large combustion environments in real time and optimizing reduction facilities based on measured values are necessary to reduce the compound's presence. This paper describes the concentration measurement for SO2, a particulate matter precursor, using a wavelength modulation spectroscopy (WMS) of tunable diode laser absorption spectroscopy (TDLAS). This study employed a quantum cascade laser operating at 7.6 ㎛ as a light source. It demonstrated concentration measurement possibility using 64 multi-absorption lines between 7623.7 and 7626.0 nm. The experiments were conducted in a multi-pass cell with a total path length of 28 and 76 m at 1 atm, 296 K. The SO2 concentration was tested in two types: high concentration (1000 to 5000 ppm) and low concentration (10 ppm or less). Additionally, the effect of H2O interference in the atmosphere on the measurement of SO2 was confirmed by N2 purging the laser's path. The detection limit for SO2 was 3 ppm, and results were compared with the electronic chemical sensor and nondispersive infrared (NDIR) sensor.

Performance Estimation of Feeding System for developing coaxial grinding system of light communicative ferrule (광통신용 페룰 가공을 위한 초미세 고기능 동축가공 연삭시스템용 이송계의 특성 평가)

  • Ahn K.J.;Choe B.O.;Lee H.J.;Hwang C.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.10-14
    • /
    • 2005
  • This report deals with a feeding system of the Coaxal grinding machine, processing optical ferrule. This report also examines the applicability of using the feeding system for the Coaxial grinding machine, by mean of conducting performance estimation. The results are as follow; Repeatability of regulating wheel is $17{\mu}m$, R/W rotation accuracy is between $30\;\~\;40{\mu}m$. This means 'Rotation accuracy' is lower than the concentricity level. Backlash generation level at the feeding system of the grinding wheel is under $1{\mu}m$, thereby positioning accuracy is controlled within $2{\mu}m$ In terms of repeatability, you can find occasional error at the returning process from the starting point. This error is resulted from the measurement tolerance of the starting point sensor. We will get the repeatability level under control by $1{\mu}m$, through improving the soft-ware used and up-grading the sensor at the starting point.

  • PDF

Development of a Ring-type Wearable Healthcare Device (반지 형태의 웨어러블 헬스케어 디바이스 개발)

  • Baek, Hyun Jae;Cho, Jaegeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.892-897
    • /
    • 2018
  • Due to population aging, an increase in the number of patients with chronic illnesses, and an increase in the number of single-person households, monitoring of health status in everyday life without the need for a hospital has become very important. For this reason, researches on various health care devices have been attempted, among which wearable devices are attracting much attention. In this paper, we propose a new ring-type wearable device for next generation healthcare. On the inner side of the ring, a metal electrodes for GSR measurement and an optical sensor for measurement of pulse wave signals of two wavelengths of red and near-infrared light were mounted. In addition, it was equipped with an acceleration sensor, and information about the degree of motion could be obtained. In this paper, it is shown that a health monitoring device can be implemented in the form of a ring, and the measured signals can be used to calculate heart rate, oxygen saturation, sleep time and sleep efficiency. Through the advanced algorithm, it is expected that we can extract various health information, especially sleep related health information by using the ring device, and it is also expected that it can contribute to the implementation of wearable healthcare effectively.

Effect of Humidity and Operating Temperature of Polymer Sensor to Methanol Gas (Methanol 가스에 대한 고분자 센서의 온도와 습도 영향 고찰)

  • Lee, K.M.;Hoh, Y.S.;Jun, H.K.;Sohn, S.O.;Huh, J.S.
    • Korean Journal of Materials Research
    • /
    • v.13 no.12
    • /
    • pp.796-800
    • /
    • 2003
  • The polypyrrole prepared with pyrrole monomer, APS and DBSA was synthesized by chemical Polymerization at $V^{\circ}C$ under atmosphere conditions. After dissolving polypyrrole powder to the chloroform including DBSA, polypyrrole film was prepared on the alumina substrate with an interdigitated electrode by using the dip-coating method. This film was soaked in methanol solvent for 1 h at room temperature and heated to $70^{\circ}C$ for 4 h in $N_2$. Initial resistance was increased with the increasing humidity and decreasing temperature. The sensitivity was increased with lower humidity and decreasing temperature. The best linearity was achieved at $25^{\circ}C$ and low humidity of 0%.

Design Fabrication and Operation of the 16$\times$16 charge Coupled Area Image Sensor Using Double Polysilicon Gates (다결정 실리콘 이중전극 구조를 이용한 16$\times$16 이차원 전하결합 영상감지소자의 설계, 제작 및 동작)

  • Jeong, Ji-Chae;O, Chun-Sik;Kim, Chung-Gi
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.3
    • /
    • pp.68-76
    • /
    • 1985
  • A charge-coupled device (CCD) area image sensor has been demonstrated with an experi-mental 16$\times$16 prototype. The prototype is a vertical frame transfer charge.coupled imager using two-phase gate electrode structures. In this device, ion-implanted barriers are used for two -phase CCD, and NMOS process has been adopted. The total imaging setup consisting of optical lens, clock generators, clock drivels, staircase signal generators, and oscilloscope is easily achieved with the aid of PROM . English alphabets are displayed on the oscilloscope screen using the total imaging set-up. We measure charge transfer inefficiency and dark current for the fabricated devices.

  • PDF

Fabrication and Performance Investigation of Surface Temperature Sensor Using Fluorescent Nanoporous Thin Film I (형광 나노 포러스 박막을 이용한 표면 온도 센서의 제작 및 성능 연구 I)

  • Kim, Hyun Jung;Yoo, Jaisuk;Park, Jinil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.12
    • /
    • pp.668-673
    • /
    • 2013
  • In this study, specimens with nano-sized porous thin films were manufactured by injecting fluorescence solution into the pores. We intended to find out the difference of the fluorescence intensity in each region of the specimen through an experimental apparatus that makes a temperature field. Before conducting experiments, the optimized manufacturing conditions were determined by analysis of all parameters that influence the emission intensity, and the experiments were carried out with the specimens produced in the optimized conditions. Then, the calibration curves of the fluorescence intensity versus temperature were performed by taking the intensity distributions from the specimen in various temperature fields. The surfaces of specimens were coated with Rhodamine-B (Rh-B) fluorescent dye and measured based on the fluorescence intensity. Silica (SiO2) nanoporous structure with 1-um thickness was constructed on a cover glass, and fluorescence dye was absorbed into these porous thin films.

A Design on Collision Avoidance System of Vehicle using Fuzzy Control Algorithms (퍼지제어 알고리즘을 이용한 차량의 충돌방지 시스템 설계)

  • Choo, Yeon-Gyu;Kim, Seung-Cheo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.705-709
    • /
    • 2005
  • In this paper, we introduce fuzzy algorithm similar to human's way of thinking and designed collision detection system of vehicles. First, before the model vehicles design, we did simulation collision detection using PID and Fuzzy Controller. As a result, P.O that is Percent Overshoot when make use of PID controller happened from smallest 32% to 45%. But, In case of using fuzzy controller they produced about 10% in 7% in case use 25 rule. We designed model vehicles that introduce Auto Guided Vehicle(AGV) with confirmed result in simulation. We set Polaroid 6500 sensor on the front of model automobile because distinguish existence automobile to the head. And we composed motor drive part to run vehicles and 80C196KC processor for control movement of vehicles influenced on distance data of the front vehicles that receive from supersonic waves sensor. In case of using Fuzzy controller, last value percent error happened about maximum 15% in smallest 5%, and we confirmed that distance with front vehicles kept when state hold time is about maximum 16 seconds in smallest 10 seconds.

  • PDF

A Study on Acoustic Emission Characteristics through the Cyclic Thermal Test of Thermal Barrier Coating by Plasma Spray Process (플라즈마 용사법에 의한 열차폐 코팅의 열피로에 따른 AE신호 특성 연구)

  • Park J.H.;Lee K.H.;Ye K.H.;Kim S.T.;Jeon C.H.;Kim J.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1349-1352
    • /
    • 2005
  • This paper is to investigate a defect for thermal barrier coating layers by acoustic emission method in 4-point bending test. The two-layer thermal barrier coating is composed of $150\mu{m}\;CoNiCrAlY\;bond\;coating\;by\;vacuum\;plasma\;spray(VPS)\;process\;and\;250\mu{m}\;ZrO_2-8wt%Y_2O_3$ ceramic coating layer by air plasma spray(APS) process on Inconel-718. The specimen prepared by cyclic thermal test(500, 1000, 2000cycle) at $1050^{\circ}C$ The AE monitoring system is composed of PICO type sensor, a wide band pre-amplifier(40dB), PC and AE DSP(16/32 PAC) board. The AE event, amplitude, Cumulative energy and count of coating specimens is evaluated according to cyclic thermal test.

  • PDF

Temperature Behavior of Superconducting Fault Current Limiters during Quenches (퀜치 시 초전도 한류기의 온도)

  • Kim H.-R.;Sim J.;Hyun O.-B.
    • Progress in Superconductivity
    • /
    • v.6 no.2
    • /
    • pp.108-112
    • /
    • 2005
  • We investigated temperature behavior of superconducting fault current limiters (SFCLs) during quenches. Knowledge on temperature behavior during quenches is important to the design of SFCLs, because the temperature of SFCLs is related to their stability. SFCLs were fabricated by patterning $Au/YBa_2Cu_3O_7$ thin films grown on sapphire substrates into meander lines by photolithography. A gold film grown on the back side of the substrate was patterned into a meander line, and used as a temperature sensor. The front meander line was subjected to simulated AC fault currents, and the back line to DC current. They were immersed in liquid nitrogen during the experiment for effective cooling. Overall, temperature at the back side of SFCLs was close to that at the front side. It was closer at the beginning of faults, and at lower applied voltages. Temperature distribution at the back side was even except at the edge, as at the front side. These results tell that the whole SFCL was heated to similar degree during quenches, and that effective cooling of SFCLs at the back side is as important to the stability of SFCLs as at the front side. The results could be explained with the concept of heat transfer within the film.

  • PDF

평판형 자기장 발생기를 이용한 자성 나노 파우더 기열에 관한 연구

  • Yu, Jae-Hyeong;Lee, Jae-Seon;No, Jun-Hyeong;Jo, Tae-Hun;Yun, Myeong-Su;Park, Bong-Ju;Choe, Eun-Ha;Gwon, Gi-Cheong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.434.1-434.1
    • /
    • 2014
  • 최근 자성 나노 입자를 이용한 온열치료가 주목을 받고 있다. 자성을 띄는 나노 입자를 암 세포에 보내, 교류 자기장을 걸어주어 회전에 의한 마찰손실로 인한 열을 이용하여 암 조직만을 국소 가열하는 원리이다. 본 실험은 유도 자기장을 사용한 자성 나노 파우더의 가열을 목적으로 시행하였다. 나선형 코일위에 세라믹, 유리 등 절연체 원판 위에 자기장이 발생되도록 휴대용 평판형 자기장 발생장치를 제작하였다. 자기장 발생 장치는 평판형 나선형 코일에 특정 주파수를 가진 전원을 인가하여 자기장을 발생시킨다. 평판형 나선형 코일은 내경 40 mm, 외경 140 mm, 2 mm 동선으로 제작하였다. 제작한 자기장 발생장치를 자기장 측정 센서(Hall sensor 등)을 원판 위에 설치하여 거리별 자기장의 크기를 측정하였다. 자기장은 나선형 코일 위 원판 중심에서 최대로 발생되어 중심에서 멀어질수록 크기가 감소하였다. 자기장 발생장치 위에 자성 나노 파우더($Fe_3O_4$$CoFe_2O_4$)를 혼합한 용액 시료를 위치시키고 자기 쌍극자 모멘트와 자기장간의 상호작용을 유도한다. 이때 자성 나노 파우더별로 발생하는 열을 열전쌍(TC)이나 Optical fiber를 사용한 Thermometer로 측정하여 비교분석하였다.

  • PDF