• Title/Summary/Keyword: $NO_x$Concentration

Search Result 628, Processing Time 0.043 seconds

The Development of Early Mouse Embryos Depend on $Ca^{2+}$ Concentration (Ca$^{2+}$ 농도에 따른 생쥐 초기배의 발생)

  • Yang, Jung-Sook;Bae, In-Ha
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.27 no.3
    • /
    • pp.275-282
    • /
    • 2000
  • Objective: This study was to determine the effect of different concentration of calcium III medium on the preimplantational development of zygotes and early 2 cell embryos. Methods: Female mice of ICR strain ($5{\sim}8$ weeks old) were superovulated and mated with fertile males. Zygotes or early 2-cell embryos were collected by flushing the oviducts $31{\sim}32$ hours after hCG injection. The embryos were cultured in various concentrations of $Ca^{2+}$ in medium or with EDTA, EGTA and $Ni^{2+}$. Result and Conclusion: Treatment of high concentraion of $Ca^{2+}$ (3.42 mM $(2X){\sim}17.l$ mM (10X)) in medium didn't develop well compared to the control. Low concentrations of $Ca^{2+}$ (0.214mM $(1/8X){\sim}0.855$ mM (1/2X) were deterimental to development beyond 2-cell stage. EDTA, $Ca^{2+}$ chelating agent was treated with ranged concentrations of EDTA (0.014 $mM{\sim}0.107$ mM) to medium contaning 1.71 mM $Ca^{2+}$ showed beneficial effect to development to blastocyst compared to the control. EGTA, extracellular $Ca^{2+}$ chelator, was treated with ranged concentrations of EGTA ($0.014{\sim}0.107$ mM) to the medium contaning 1.71 mM $Ca^{2+}$. There is no significant difference with the control. $Ni^{2+}$ (50 ${\mu}M$), T-type $Ca^{2+}$-channel blocker was treated to medium contaning low concentration of $Ca^{2+}$. It overcame 2-cell block significantly. Rate of degenerated embryos decreased and developmental rate to morula and blastocyst increased more than low $Ca^{2+}$ concentration alone. Further studies are needed for the overcoming effect of 2-cell block by $Ni^{2+}$.

  • PDF

Analysis of Photochemical Ozone Formation Regime in Busan - Comparative Study on Busan vs. Seoul Metropolitan Area(Ⅳ) (부산지역 광화학 오존 생성 regime 분석 - 수도권과 비교연구 (Ⅳ))

  • Seung-Hee Baek;Hyo-Jung Lee;Cheol-Hee Kim
    • Journal of Environmental Science International
    • /
    • v.32 no.5
    • /
    • pp.285-301
    • /
    • 2023
  • This study analyzed characteristics of ozone (O3) formation regimes in Busan over a period of recent five years (2015~2019) and compared the findings with those obtained in Seoul. We employed four observed variations: early morning commuting-hour (i.e., 06:00-09:00 LST) nitrogen dioxide (NO2), peak-hour (i.e., 12:00-16:00 LST) O3, 8-hour average O3 (MDA8 O3), and △O3 (=O3_max- O3_min) in Busan and Seoul. In addition, the NO2-O3 relation was assessed to interpret which of NOx-limited or volatile organic compound (VOC)-limited was dominant. In Busan, the annual mean O3 concentration was relatively higher than in Seoul, whereas there were fewer high-concentration days. The Pearson correlation coefficients (R) between Early morning-hour NO2 and the Peak-hour O3 was positive (but close to zero) in Busan and negative in Seoul. Likewise, the R between the Early morning-hour NO2 and the △O3 showed a relatively considerable positive correlation (R=+0.4~0.5)(R=+0.4~0.5) in Busan, while a weak positive correlation (R=+0.1~0.2) in Seoul. From this result, it can be inferred that the O3 formation regime in Busan was intrepreted to be nearly neutral or relatively closer to the NOx-limited regime than Seoul, while Seoul to the VOC-limited regime. The study findings imply that O3 control strategies should be applied differently in Busan and Seoul. The results here were inferred from surface NO2 and O3 observations, and the varification studies based on in-situ VOCs measurements would be needed.

Numerical Simulation of Environmental Pollutants at Yosu, Korea and Comparison with Measured Data

  • Lee, S. D.;A. Kondo;K. Yoshimura;K. Yamaguchi;A. Kaga
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.E2
    • /
    • pp.63-73
    • /
    • 2003
  • The atmospheric pollution distribution in the industrial area of Yosu in Korea is calculated using numerical model and the model is validated by comparing the calculations with observed data. The emission of NO$_{x}$ and SO$_{x}$ was estimated for 6 sources, and the emission amount of HC was estimated for 9 anthropogenic sources. The calculated wind speed, wind direction and temperature agreed well with the observed data at two observatories, and the calculated concentration of NO, NO$_2$, $O_3$ and SO$_2$ were also reasonable for 5 monitoring stations. The validity of the model is evaluated using 3 indexes of the EPA, and the model is found to be valid and accurate.ate.

Development of NO2/NOx Ratio Estimation Model for Urea-SCR System Application on Non-road Diesel Engine (비도로용 디젤엔진의 Urea SCR system 적용을 위한 NO2/NOx ratio 예측모델 개발에 관한 연구)

  • Kang, Seokho;Kim, Hoonmyung;Kang, Jeongho;Park, Eunyong;Kwon, Ohyun;Kim, Daeyeol
    • Journal of ILASS-Korea
    • /
    • v.25 no.4
    • /
    • pp.178-187
    • /
    • 2020
  • The current emission regulations, US Tier-4 and EU Stage-V, are only able to satisfy the regulations when all currently mass-produced emission reduction technologies such as EGR, DOC, DPF, and SCR are applied. Therefore, in this study, for the application of the Urea-SCR system to non-road diesel engines, the database was established by measuring the NO, NO2 concentration and calculating the NO2/NOx ratio based on the catalyst temperature and exhaust mass flow rate. Also, based on the measured NO2/NOx ratio data, a mathematical model was proposed to predict the NO2/NOx ratio at SCR catalyst, and the suitability of the model was verified through steady-state and transient mode. As a result of comparing the NO2/NOx ratio measured at the DOC outlet under the steady-state condition to two model values separately, the R2 was 0.9811 for the 3D map model and 0.9303 for the mathematical model. And in the case of the NO2/NOx ratio measured at the DPF outlet, the R2 was 0.9797 for the 3D map model and 0.935 for the mathematical model. It was confirmed that the R2 with the model value of the 3D Map of the mathematical model in the transient mode is 0.957, which shows high reliability.

NO REDUCTION PROPERTY OF Pt-V2O5-WO3/TiO2 CATALYST SUPPORTED ON PRD-66 CERAMIC FILTER

  • Kim, Young-Ae;Choi, Joo-Hong;Bak, Young-Cheol
    • Environmental Engineering Research
    • /
    • v.10 no.5
    • /
    • pp.239-246
    • /
    • 2005
  • The effect of Pt addition over $V_2O_5-WO_3/TiO_2$ catalyst supported on PRO-66 was investigated for NO reduction in order to develop the catalytic filter working at low temperature. Catalytic filters, $Pt-V_2O_5-WO_3/TiO_2/PRD$, were prepared by co-impregnation of Pt, V, and W precursors on $TiO_2$-coated ceramic filter named PRD (PRD-66). Titania was coated onto the pore surface of the ceramic filter using a vacuum aided-dip coating method. The Pt-loaded catalytic filter shifted the optimum working temperature from $260-320^{\circ}C$(for the catalytic filter without Pt addition) to $190-240^{\circ}C$, reducing 700 ppm NO to achieve the $N_x$ slip concentration($N_x\;=\;NO+N_2O+NO_2+NH_3$) less than 20 ppm at the face velocity of 2 cm/s. $Pt-V_2O_5-WO_3/TiO_2$ supported on PRD showed the similar catalytic activity for NO reduction with that supported on SiC filter as reported in a previous study, which implies the ceramic filter itself has no considerable interaction for the catalytic activity.

A Study on Mensurement of NO Concentrations in Laminar Non-premixed H2/N2 Flame Using LIF (레이저 유도 형광법(LIF)을 이용한 층류 비예혼합 수소/질소 화염에서의 NO 농도 측정에 관한 연구)

  • Jin, Seong Ho;Kim, Sung Wook;Park, Kyoung Suk;Kim, Gyung Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.13 no.4
    • /
    • pp.279-286
    • /
    • 2002
  • In this study, quantitative nitric oxide concentration distributions are investigated in the laminar non-premixed $H_2/N_2$ flames by laser-induced fluorescence (LIF). The measurements are taken in flames for different $N_2$ dilution ratios varying from 20~80%, and fuel flow rate is fixed as Islpm. The NO A-X (0,0) vibrational band around 226 nm is excited using a XeCl excimer-pumped dye laser. We applied same excitation line used in $CH_4$, premixed flame. Overall, NO concentration was rapidly decreased with Na addition and we could not measure the concentration any longer for $N_2$ dilution above 80%.

The Urinary Fluoride Concentration and Periodontal Condition in Postmenopausal Osteoporotic Women (골밀도가 저하된 폐경 후 성인여성의 뇨중 불소농도와 치주조직과의 관계)

  • Kim, Young-Jun
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.4
    • /
    • pp.837-846
    • /
    • 1999
  • There were few reports about the fluoride concentration in bone and osteoporotic women. This study was designed to evaluate the relationship between the urinary fluoride concentration and periodontal condition in osteoporotic old women. Twentyeight postmenopausal women(Test group) and twenty-one premenopausal women(Control group) were examined. Bone mineral density(BMD) of lumbar spine(L2-L4) was measured by dual energy X-ray absorptiometry(DEXA). The urine samples were collected at early morning and determined with the help of a fluoride-specific electrode and Tisabbufferd samples. The results were as follows. 1. The mean urinary fluoride concentration in test and control group showed statistically no difference. 2. The bone mineral density(BMD) of the spine in test group was significantly lower than control group(p<0.05). 3. The significant negative correlation was found between BMD level and age after menopause $(p<0.001,\;{\gamma}=-0.526$. 4. The urinary fluoride concentration was not correlated with age, age after menopause and bone mineral density. 5. The urinary fluoride concentration was not correlated with periodontal condition.

  • PDF

Domestic Ozone Sensitivity to Chinese Emissions Inventories: A Comparison between MICS-Asia 2010 and INTEX-B 2006 (중국 배출량 목록에 대한 국내 오존 민감도 분석: MICS-Asia 2010와 INTEX-B 2006 비교사례)

  • Kim, Soontae;Bae, Changhan;Kim, Eunhye;You, Seunghee;Bae, Minah;Lee, Jae-bum;Seo, Inseok;Lim, Yongjae;Kim, Byeong-Uk;Kim, Hyun Cheol;Woo, Jung-Hun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.5
    • /
    • pp.480-496
    • /
    • 2017
  • CMAQ (Community Multiscale Air Quality)-HDDM (High-order Direct Decoupled Method) simulations with MICS-Asia 2010 and INTEX-B 2006 emissions inventories were performed to investigate the impact of Chinese $NO_x$ and VOC emissions on 1-hr ozone concentrations over South Korea during May to July in 2014. Chinese $NO_x$ and VOC emissions in MICS-Asia 2010 were 60% higher and 100% lower than those in INTEX-B 2006 during the simulation period. It makes the ratio of Chinese VOC to $NO_x$ emissions in INTEX-B 2006 (Case 1) is 3.2 times higher than that in MICS-Asia 2010 (Case 2). When the observed period mean 1-hr ozone concentration averaged across 106 air monitoring sites in the SMA (Seoul Metropolitan Area) was 37.6 ppb, the modeled values were similar to each other; 37.3 ppb for Case 1, and 40.4 ppb for Case 2. Both cases show that daily maximum 1-hr ZOC (Zero-Out Contribution) of Chinese $NO_x$ and VOC emissions were as high as 55 ppb and 35 ppb for the episode respectively. Correlation coefficients between ZOC of Chinese $NO_x$ and VOC emissions and the SMA daily maximum 1-hr ozone were 0.49~0.69. It indicates that Chinese emissions occasionally affect the SMA daily ozone peaks. On the other hand, Case 2 predicted 7 ppb and 1 ppb higher ZOC of Chinese $NO_x$ and VOC emissions than Case 1, when simulated ozone in the SMA is over 80 ppb. It implies that upwind $NO_x$ emissions would be more important than upwind VOC emissions for the long-range transport of ozone in Northeast Asia.

Evaluation of External Carbon Source on the 2 Stage Denitrification Process by Simulation of GPS-X (GPS-X 시뮬레이션을 이용한 2단탈질 공정에서 외부탄소원 적용성 평가)

  • Chung, Chang-Wha;Shim, Yu-Seop;Kim, Tae-Hyung;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.1
    • /
    • pp.37-48
    • /
    • 2004
  • The purpose of this study was to evaluate adaptability of external carbon source using GPS-X program in pilot plant composed with 2-stage denitrification process. The result from analysis of pilot plant operation and GPS-X simulation showed that effluent concentration could be simulated similarly by modifying operation conditions, such as DO concentration, C/N ratio and other calibrated parameter. In order to satisfy the standard of the effluent water quality on T-N of 20mg/L, it required approximately 3.1 of C/N ratio and 50% of nitrogen removal efficiency when influent T-N is 36.9mg/L. To maintain the stable water quality of the receiving water, the effluent T-N concentration should be less than 10-15mg/L and the appropriate C/N ratio to remove nitrogen was 4.27-6.82. The analysis of sensitivity to kinetic coefficient and reaction constant showed that $Y_H$ and ${\mu}_{mAUT}$ were most sensitive to nitrate and ammonia nitrogen, relatively and sensitivity coefficient of their were 1.32, 1.98. It was concluded that as $Y_H$ decreased and ${\mu}_{mAUT}$ increased, the reaction rates of denitrification and nitrification increased and the removal efficiencies of $NO_3{^-}-N$ and $NH_4{^+}-N$ improved.

Comparison of Temperature and Light Intensity Effects on the Photooxidation of Toluene-NOx-Air Mixture (온도와 광도가 톨루엔-NOx-공기 혼합물의 광산화 반응에 미치는 영향의 비교)

  • Ju, Ok-Jung;Bae, Gwi-Nam;Choi, Ji-Eun;Lee, Seung-Bok;Ghim, Young-Sung;Moon, Kil-Choo;Yoon, Soon-Chang
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.3
    • /
    • pp.353-363
    • /
    • 2007
  • To differentiate temperature effect from the light intensity effect on the formation of secondary products during the photooxidation of toluene-$NO_x$-air mixtures, steady-state air temperature was changed from $20^{\circ}C\;to\;33^{\circ}C$ at the same light intensity of $0.39min^{-1}$ in an indoor smog chamber. Smog chamber consisted of 64 blacklights and a $5.8m^3$ reaction bag made of Teflon film. Air temperature was controlled by an air-conditioning system. The starting time for rapid conversion of NO to $NO_2$ was slightly delayed with decreasing air temperature. In contrast to light intensity effect, the ozone formation time and the ozone production rate were insensitive to air temperature. Although the formation time for secondary organic aerosols was not changed, the particle number concentration increased with temperature. However, the newly formed secondary organic aerosol mass at lower temperature was higher than that at higher temperature. Since light intensity significantly affected the starting time and quantity of ozone and aerosol formation, it is considered that the temperature could contribute partly the quantity of aerosol formation during the photooxidation of toluene-$NO_x$-air mixtures.