• Title/Summary/Keyword: $F_0$ value

Search Result 1,915, Processing Time 0.029 seconds

Simple and Quantitative Analysis Method for Total Carbohydrate Concentration in Oligosaccharides by using TLC (TLC를 이용한 올리고당 각 성분 총 당량의 빠르고 정량적인 분석)

  • 이진하;이형우;이형기;조동련;선우창신;박기덕;최정식;김도원;김도만
    • KSBB Journal
    • /
    • v.19 no.4
    • /
    • pp.269-273
    • /
    • 2004
  • A simple, fast and reproducible quantitative analysis method for sugar concentration composed in oligosaccharide mixture was developed. Two glass TLC plates were prepared per sample. After dipping one plate into the copper bicinchoninate reagent and the other plate into 5% sulfuric acid solution, both plates were baked in microwave oven until sugar spots were developed or the surface temperature of TLC plate becomes 60 to 70 $^{\circ}C$. The corrective factor values [F value =(the value of total sugar concentration converted as glucose unit/the value of reducing sugar concentration converted as glucose unit)/(polymerization degree of sugar)] of different molecular weight sugars were determined. Within the concentration of 0.25∼1.0 $\mu\textrm{g}$ in each sample loaded, the fructose-F (corrective factor value of fructose) was 0.45, yet for the higher concentration (2.5∼7.5 $\mu\textrm{g}$) fructose-F was 1.0. In case of glucose, in the range of 0.5∼7.5 $\mu\textrm{g}$, glucose-F was same as fructose-F, 1.0. However, as the molecular weight of sugar was increased, the F values were decreased in both maltodextrin and isomaltodextrin oligosaccharides in 0.5∼7.5 $\mu\textrm{g}$ of each sample loaded. Interestingly, F values were equal for the same molecular weight sugars, although the structures were different from each other. Using F value of each sugar, we could determine and compare the exact total sugar concentration of different molecular weight maltooligosaccharide and isomaltooligosaccharide. We also could determine if the unknown sugar was a reducing or non-reducing compound by using optimized TLC with microwave oven method.

Evaluation for Applications of Displacement Criterion by the Critical Strain of Uniaxial Compression in Rock Mass Tunnel (일축압축 한계변형률에 의한 암반터널 변위기준 적용성 평가)

  • Kim, Young-Su;Kim, Dae-Man
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6C
    • /
    • pp.321-329
    • /
    • 2009
  • Laboratory compressive test was conducted on 6 different types of rock in order to investigate the characteristic of critical strain under uniaxial and triaxial stress condition. The results of uniaxial compressive test mostly ranged within 1~100MPa, the critical strain was also located between 0.1~1.0%. Therefore the results distributed within the upper and lower boundary proposed by Sakurai (1982). And the failure/critical strain ratio (${\varepsilon}_f/{\varepsilon}_0$) showed between 1.0~1.8 value depending on the uniaxial compressive strength. The results of critical strain by triaxial compressive test showed below 0.8% value for all test, the M value calculated from uniaxial and triaxial compressive test results ranged 1.0~8.0 for most of rock specimens. It is concluded that failure strain (${\varepsilon}_{f3}$) of rock mass, which is in triaxial stress condition is larger than the results of uniaxial stress condition (${\varepsilon}_{f1}$) by 1.0~8.0 times and value showed 1.0~1.8 larger value than critical strain (${\varepsilon}_{01}$). Therefore it is a conservative way for rock tunnel to use critical strain (${\varepsilon}_{01}$) calculated from a uniaxial compressive strength on tunnel displacement monitoring.

Prevalence of JAK2 V617F, CALR, and MPL W515L Gene Mutations in Patients with Essential Thrombocythemia in Kurdistan Region of Iraq

  • Saeed, Bestoon Muhammad;Getta, Hisham Arif;Khoshnaw, Najmaddin;Abdulqader, Goran;Abdulqader, Aveen M. Raouf;Mohammed, Ali Ibrahim
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.1
    • /
    • pp.41-48
    • /
    • 2021
  • Essential thrombocythemia (ET) is a clonal bone marrow stem cell disorder, primarily involving the megakaryocytic lineage. The WHO 2016 guidelines include the molecular detection of JAK2, MPL, and CALR mutations as a major diagnostic criterion for ET. This study aimed to determine the frequency of JAK2 V617F, MPL W515L, and CALR mutations in Iraqi Kurdish patients afflicted with ET, and to analyze their clinical and hematological features. A total of 73 Iraqi Kurdish patients with ET were enrolled as subjects, and analysis was achieved utilizing real-time PCR. The frequency of JAK2 V617F, CALR, and MPL W515L mutations was determined to be 50.7%, 22%, and 16.4%, respectively. No statistically significant difference was obtained when considering the age and gender among different genotypes. The JAK2 V617F mutated patients had significantly higher white blood cell counts and hemoglobin levels than the CALR-positive patients (P-value=0.000, 0.007, respectively), MPL W515L-positive patients (P-value=0.000, 0.000, respectively), and triple negative patients (P-value=0.000, 0.000, respectively). Also, the JAK2 V617F mutated patients showed higher platelet count as compared to the MPL W515L-positive patients (P-value=0.02) and triple negative patients (P-value=0.04). Furthermore, significantly lower white blood cell count and hemoglobin levels were associated with CALR positivity (P-value=0.000, 0.01, respectively), MPL W515L-positivity (P-value=0.001, 0.000, respectively), and triple negativity (P-value=0.000, 0.000, respectively), as compared to patients with combined mutations. In conclusion, apart from a relatively high frequency of MPL W515L mutation, our data is comparable to earlier reports, and highlights the importance of genotyping the JAK2 V617F, MPL W515L, and CALR mutations for accurate diagnosis of patients with ET.

3D-QSAR (CoMFA, CoMSIA) study of PPAR-$\gamma$ agonists.

  • Lee, Hye-Sun;Chae, Chong-Hak;Yoo, Sung-Eun;Yi, Kyu-Yang;Park, Kyung-Lae
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.181.3-181.3
    • /
    • 2003
  • Comparative molecular field analysis (CoMFA) and comparative molecular similarity indices analysis (CoMSIA) were performed on 60 PPAR-g agonists. Partial Least Squars (PLS) analysis produced good predicted models with $q^2$ value of 0.62 (SDEP=0.33, F value=93.22, $r^2$=0.92) and 0.56 (SDEP=0.47 F value=27.65, $r^2$=0.86), respectivly. The key spatial properties were detected by careful analysis of the isocontour maps.

  • PDF

The Attenuation Structure of the South Korea: A review

  • Chung, T. W.;Noh, M. H.;Matsumoto, S.
    • Journal of the Korean Geophysical Society
    • /
    • v.9 no.3
    • /
    • pp.199-207
    • /
    • 2006
  • Fukuoka earthquake on March 20, 2005 showed the potential hazard of large events out of S. Korea. From the viewpoint of seismic hazard, seismic amplitude decrease Q-1 is very important. Related to the crustal cracks induced by the earthquakes, the value of Q-1- high Q-1 regions are more attenuating than low Q-1 regions - shows a correlation with seismic activity; relatively higher values of Q-1 have been observed in seismically active areas than in stable areas. For the southeastern and central S. Korea, we first simultaneously estimated QP-1 and QS-1 by applying the extended coda-normalization method to KIGAM and KNUE network data. Estimated QP-1 and QS-1 values are 0.009 f-1.05 and 0.004 f-0.70 for southeastern S. Korea and 0.003 f -0.54 and 0.003 f -0.42 for central S. Korea, respectively. These values agree with those of seismically inactive regions such as shield. The low QLg-1 value, 0.0018f -0.54 was also obtained by the coda normalization method. In addition, we studied QLg-1 by applying the source pair/receiver pair (SPRP) method to both domestic and far-regional events. The obtained QLg-1 for all Fc is less than 0.002, which is reasonable value for a seismically inactive region.

  • PDF

POSITIVE PSEUDO-SYMMETRIC SOLUTIONS FOR THREE-POINT BOUNDARY VALUE PROBLEMS WITH DEPENDENCE ON THE FIRST ORDER DERIVATIVE

  • Guo, Yanping;Han, Xiaohu;Wei, Wenying
    • Journal of applied mathematics & informatics
    • /
    • v.28 no.5_6
    • /
    • pp.1323-1329
    • /
    • 2010
  • In this paper, a new fixed point theorem in cone is applied to obtain the existence of at least one positive pseudo-symmetric solution for the second order three-point boundary value problem {x" + f(t, x, x')=0, t $\in$ (0, 1), x(0)=0, x(1)=x($\eta$), where f is nonnegative continuous function; ${\eta}\;{\in}$ (0, 1) and f(t, u, v) = f(1+$\eta$-t, u, -v).

Prediction of Fatigue Life in 2024-73 Aluminum Using X-ray half-value breadth

  • Kim, Soon-Ho;Cho, Seok-Swoo;Park, Jung-Hyeon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.3 no.2
    • /
    • pp.78-86
    • /
    • 2002
  • In general, X-ray diffraction method detects the changes of crystal lattice under material surface using the angle of diffraction 2$\theta$. This technique which deals with in the presented paper can be applied to a behavior on the slipped band or the micro crack cause to material degradation. The relation between half-value breadth and cycle numbers shows three stages, which consist of rapid decrease in the initial cycle, slight decrease in the middle cycle, and then rapid decrease in the final cycle. The ratio of half-value breadth has a constant value on B/B$\_$0/ - N diagram under the loading condition except early part of fatigue life. The ratio of half-value breadth B/B$\_$0/ - log N$\_$f/ with respect to number of cycle to failure N$\_$f/ has linear behavior on B/B$\_$0/ - log N$\_$f/ diagram. Therefore, the evaluation of fatigue life by the average gradient has much less mean error than the estimation of fatigue life by log B/B$\_$0/ - log N/N$\_$f/ relation.

Hematological Reference Values in the Healthy Adults (건강성인의 혈구 참고치 산정)

  • Kim, Young-Jin;Hyun, Myung-Soo;Lee, Hyun-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.1
    • /
    • pp.154-165
    • /
    • 1991
  • To establish the hematological reference values in the healthy adults visited our hospitals, following examination were done on 2823 persons by Coulter Counter Model S-plus II ; white blood cell count: (WBC), red blood cell count(RBC), hemoglobin(Hb), hematocrit(Hct), mean corpuscular volume (MCV), mean corpuscular hemoglobin(MCH), mean corpuscular hemoglobin concentration(MCHC), red cell distribution width(RDW), platelet, plateletcrit, mean platelet volume(MPV) and platelet distribution width(PDW). The following results are obtained. 1) Male, mean value of WBC ; $6,800{\pm}2,680(2SD)/{\mu}l$ Female, mean value of WBC ; $5,950{\pm}2,380(2SD)/{\mu}l$ 2) Male, mean value of RBC ; $428{\pm}60(2SD){\times}10^4/{\mu}l$ Female, mean value of WBC ; $415{\pm}56(2SD){\times}10^4/{\mu}l$ 3) Male, mean value of Hb ; $15.4{\pm}1.8(2SD)g/dL$ Female, mean value of Hb ; $13.0{\pm}1.6(2SD)g/dL$ 4) Male, mean value of Hct ; $45.3{\pm}5.0(2SD)%$ Female, mean value of Hct ; $38.2{\pm}4.6(2SD)%$ 5) Male, mean value of MCV ; $93.8{\pm}5.8(2SD)fL$ Female, mean value of MCV ; $92.2{\pm}7.4(2SD)fL$ 6) Male, mean value of MCH ; $31.8{\pm}2.2(250)pg$ Female, mean value of MCH ; $31.4{\pm}2.8(2SD)pg$ 7) Male, mean value of MCHC ; $34.0{\pm}1.2(2SD)%$ Female, mean value of MCHC ; $33.9{\pm}1.2(2SD)%$ 8) Male, mean value of RDW ; $12.7{\pm}1.0(2SD)%$ Female, mean value of RDW ; $12.6{\pm}1.4(2SD)%$ 9) Male, mean value of Platelet ; $242.9{\pm}87.8(2SD){\times}10^3/{\mu}l$ Female, mean value of Platelet ; $242.2{\pm}89.0(2SD){\times}10^3/{\mu}l$ 10) Male, mean value of Plateletcrit ; $0.201{\pm}0.076(2SD)%$ Female, mean value of Plateletcrit ; $0.204{\pm}0.076(2SD)%$ 11) Male, mean value of MPV ; $8.20{\pm}1.70(2SD)fl$ Female, mean value of MPV ; $8.36{\pm}1.82(2SD)fl$ 12) Male, mean value of PDW ; $16.1{\pm}0.8(2SD)%$ Female, mean value of PDW ; $16.0{\pm}0.8(2SD)%$.

  • PDF

Quality differences of retorted Samgyetangs as affected by F0-value levels (레토르트 삼계탕의 F0값 수준에 따른 품질 차이)

  • Lee, Jin Ho;Song, Gi Chang;Lee, Keun Taik
    • Food Science and Preservation
    • /
    • v.23 no.6
    • /
    • pp.848-858
    • /
    • 2016
  • This study was conducted to determine the $F_0$-values of a retort machine at different locations and to evaluate the effects of these $F_0$-values on various quality characteristics of retorted Samgyetang samples. Samples were divided into three groups based on $F_0$-values-T1, 10~20; T2, 20~30; T3, >30. Mineral content in Samgyetang broth and breast meat mostly increased with increasing $F_0$-values. In general, the free amino acid values, hardness, and springiness, except for bone springiness, of Samgyetang decreased significantly at higher $F_0$-values. Protein content of meat and broth of the treated samples were significantly lower than that of the control. An increase in the digestion rate of meat and porridge, as well as the turbidity of the broth was observed in most of the treated samples with increasing $F_0$-values. With increasing $F_0$-values, the $L^*$ and $b^*$ values of meat and the $b^*$ values of broth tended to increase, while the $a^*$ value of broth increased significantly. Electronic nose analysis revealed different flavor patterns for samples treated at different $F_0$-values. For sensory traits, samples treated with higher $F_0$-values tended to receive lower evaluations. Particularly, the color and texture of T3 samples were lower than those of T1 and T2 samples. In conclusion, to improve the quality of Samgyetang, the efficiency and optimization of retort machines as well as the standardization of sterilization techniques are needed.

Determination of PCDD/F in Working Clothes of a Municipal Waste Incineration (생활폐기물 소각장 작업복 샘플의 다이옥신 분석)

  • 박순자;신정화;신정숙;정명희;안윤경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.2
    • /
    • pp.354-363
    • /
    • 2004
  • PCDD/F (Polychlorinated dibenzo-p-dioxins and dibenzofurans) in both of treated fabric and untreated fabric for working clothes of a municipal waste incineration were determinated. The treated fabric for working clothes was developed for less exposure of PCDD/F in municipal waste incinerations. The total concentrations of PCDD/F in some parts such as surface, middle layer, inside for treated and untreated fabric were investigated. The I-TEQ value of surface was 0.23370ng TEQ/g for treated fabric, 0.15355ng $.$ TEQ/g for non-treated fabric. On the other hand, the value of middle layer was 0.00077ng $.$ TEQ/g, 0.00177ng $.$ TEQ/g, respectively. The surface of the treated fabric containing high levels PCDD/F was caused by absorption of them. Therefore, PCDD/F of the treated fabric in middle layer was less I-TEQ value than that of the untreated fabric. The treated fabric makes effect on preventing PCDD/F from permeating into human body.