• Title/Summary/Keyword: $Co_2$ Emission

Search Result 2,501, Processing Time 0.031 seconds

Development of Emission Factors for Greenhouse Gas (CO2) from Bituminous coal Fired Power Plants (에너지사용시설의 온실가스 배출 특성 연구 -유연탄 화력발전소의 이산화탄소를 중심으로-)

  • Jeon Eui Chan;Sal Jae Whan;Lee Seong Ho;Jeong Jae Hak;Kim Ki Hyun;Bae Wi Sup
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.1
    • /
    • pp.107-116
    • /
    • 2006
  • The main purpose of this study is to develop the greenhouse gas emission factor for power plant using bituminous coal. The power plant is a major source of greenhouse gases among the sectors of fossil fuel combustion, thus information of its emission factors is very essential to the establishment of control strategies for the greenhouse gas emissions. These emission factors derived in this study were compared with those of U. S. EPA, AGO and CCL. The $CO_{2}$ concentrations in the flue gas were measured using NDIR analyser and the GC-FID with a methanizer. The amount of carbon (C) and hydrogen (H) in fuel was measured using an elemental analyzer. Calorific values of fuel were also measured using a calorimeter. Caloric value of bituminous coal used in the power plants were 5,957 (as received basis), 6,591 (air-dried basis) and 6,960 kcal/kg (dry basis). Our estimates of carbon emission factors were lower than those of IPCC. The CO2 emission factors for the power plants using bituminous coal were estimated to be 0.791 Mg/MWh (by carbon contents and caloric value of the fuel) and 0.771 Mg/MWh (by $CO_{2}$ concentration of the flue gas). The $CO_{2}$ emission factors estimated in this study were $3.4\sim 5.4\%$ and $4.4\sim 6.7\%$ lower than those of CCL (2003) and U. S. EPA (2002).

Efficiency at Energy Industry : A Comparison of Energy Consumption Efficiency among Asian Pacific Countries

  • Kim, Tae-Ho
    • International Journal of Quality Innovation
    • /
    • v.9 no.3
    • /
    • pp.113-121
    • /
    • 2008
  • This paper proposes a scheme to estimate the technical efficiency of energy consumption and production and shadow prices of $CO_2$ emission in country-level at Asia Pacific countries by Data Envelopment Analysis (DEA). The result of technical efficiency estimation shows that there exists an heterogeneity and a substantial opportunity for improvement in technical efficiency at energy consumption and production across countries, specially in the $CO_2$ emission, which implies that more pollutant are spread in air. Each country will have the different willingness to pay for the additional $CO_2$ emission right and this result enables us to predict the competition in international $CO_2$ emission right market.

Low NOx MILD Combustion for Sawdust Fuel (폐목 톱밥 연료의 저NOx MILD연소)

  • Shim, Sung-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.153-156
    • /
    • 2008
  • MILD combustion has been successfully applied to gaseous fuels and few commercial systems are now in operation. Extending MILD combustion applicability to solid fuel of sawdust is the focus of the present work. The MILD combustion furnace at the University of Adelaide in Australia was used in this study. A measurement of $O_2$ and CO emissions have been carried out in parallel with consideration of NOx emission and compared in each modes of conventional natural gas combustion, natural gas MILD combustion, NOx emission in natural gas MILD combustion mode can be reduced to 20% in comparison with conventional combustion. Emission in cases of air carrying sawdust combustion and $CO_2$ carrying sawdust combustion were also compared. Air and $CO_2$ were sued as a carry gas for the sawdust. It was found that MILD conditions are possible for sawdust particles of less than $355{\mu}m$ without additional air pre-heating. It was also found that when using $CO_2$ as the carry gas the flame inside the furnace was not visible anymore and that NOx emission dropped to less than two folds.

  • PDF

Probability-Based LCCO2 Evaluation for Undergroung Structture with Repairing Timings Exposed to Carbonation (탄산화에 노출된 지하구조물의 보수횟수에 따른 LCCO2 평가)

  • Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.3
    • /
    • pp.239-246
    • /
    • 2017
  • RC(Reinforced Concrete) structures can keep their performance during intended service life through initial service life and extension of the life through repairs. In the deterministic repairing method, cost and the related $CO_2$ emission increase with step-shaped escalation, however continuous results can be obtained through probabilistic repairing technique, and this is capable of reducing $CO_2$ emission through $CO_2$ absorption. In the work, repairing timing and $CO_2$ emission/absorption are evaluated based on the different methods like deterministic and probabilistic manner. The probabilistic technique considering $CO_2$ absorption with carbonation progress is evaluated to be very effective to reduction of $CO_2$ emission through extension of initial and additional service life due to repairs. When the variations of the service life from initial construction and repair material can be determined, the proposed technique can contribute to reduction of cost and $CO_2$ with decreasing repairing number.

Estimation of GHG emission and potential reduction on the campus by LEAP Model (LEAP 모델을 이용한 대학의 온실가스 배출량 및 감축잠재량 분석)

  • Woo, Jeong-Ho;Choi, Kyoung-Sik
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.3
    • /
    • pp.409-415
    • /
    • 2012
  • Post-kyoto regime has been discussing with the GHG reduction commitment. GHG energy target management system also has been applied for the domestic measures in the country. Universities are major emission sources for GHG. It is very important for campus to built the GHG inventory system and estimate the potential GHG emission reduction. In general, GHG inventory on the campus was taken by the IPCC guidance with the classification of scope 1, 2, and 3. Electricity was the highest portion of GHG emission on the campus as 5,053.90 $tonsCO_2eq/yr$ in 2009. Manufacturing sector was the second high emission and meant GHG in laboratory. Potential GHG reduction was planned by several assumptions such as installation of occupancy sensor, exchanging LED lamp and photovoltaic power generation. These reduction scenarios was simulated by LEAP model. In 2020, outlook of GHG emission was estimated by 17,435.98 tons of $CO_2$ without any plans of reduction. If the reduction scenarios was applied in 2020, GHG emission would be 16,507.60 tons of $CO_2$ as 5.3% potential reduction.

CO2 Emission and Productivity of Fossil-fueled Power Plants: A Luenberger Indicator Approach (CO2 배출량을 감안한 화력발전소의 생산성 변화 분석: Luenberger지수 접근법)

  • Kwon, Oh-Sang
    • Environmental and Resource Economics Review
    • /
    • v.19 no.4
    • /
    • pp.733-752
    • /
    • 2010
  • This study applies the Luenberger indicator approach to estimate productivity of the Korean fossil-fueled power plants. A panel data set of 25 power plants was used. The method incorporates $CO_2$ emission as an undesirable output and shows that ignoring $CO_2$ emission overestimates the productivity change. There are two sources of overestimation. First, the usual method estimates productivity change ignoring the increase in $CO_2$ emission that occurred during the study period. Second, the productivity change estimated by the usual method that does not incorporate $CO_2$ emission is very sensitively affected by the change in operation rate. The paper decomposes the productivity change into the efficiency change and the technical change. The results show that the two sources contribute to the productivity change almost equally. It is also shown that the size and the pattern of productivity change are dependent on the plants' fuel types. Non-LNG power plants which saved their energy consumption and thereby reduced their $CO_2$ emission have achieved relatively high rate of productivity improvement.

  • PDF

Combustion Emission Characteristics on the Effect of Secondary Air Injection in Model Gas Turbine Combustor (모형 가스터빈 연소기의 2차공기 주입에 따른 연소배출특성)

  • 김규성;임경달;이도형
    • Journal of Ocean Engineering and Technology
    • /
    • v.14 no.3
    • /
    • pp.84-89
    • /
    • 2000
  • The purpose of this study is to investigate the combustion emission characteristics by the effect of secondary air injection and variation of the excess air ratio in combustion field of model gas turbine combustor. For this purpose, mean temperature, CO, $CO_2$, $O_2$ and HC concentrations were measured by changing excess air ratio and secondary air injection. As a result of this study, mean temperature was decreased and CO, HC emission increased by increasing the excess air ratio of secondary air. Therefore, this results showed the secondary air injection effected strongly on the flame structure and combustion emission characteristics.

  • PDF

The distribution of the molecular hydrogen in the Milky way

  • Jo, Young-Soo;Seon, Kwang-Il;Min, Kyoung-wook
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.40.1-40.1
    • /
    • 2016
  • We present the far-ultraviolet fluorescent molecular hydrogen ($H_2$) emission map observed with FIMS/SPEAR for ~76% of the sky. The fluorescent $H_2$ emission is found to be saturated by strong dust extinction at the optically thick, Galactic plane region. However, the extinction-corrected intensity of fluorescent $H_2$ emission is found to have strong linear correlations with the well-known tracers of the cold interstellar medium, such as the E(B-V) color excess, neutral hydrogen column density N(HI), $H{\alpha}$ emission, and CO $J=1{\rightarrow}0$ emission. The all-sky molecular hydrogen column density map is also obtained using a photodissociation region model. We also derive the gas-to-dust ratio, hydrogen molecular fraction ($f_{H2}$), and $CO-to-H_2$ conversion factor ($X_{CO}$) of the diffuse interstellar medium. The gas-to-dust ratio is consistent with the standard value $5.8{\times}10^{21}atoms\;cm^{-2}mag^{-1}$, and the $X_{CO}$ tends to increase with E(B-V), but converges to the Galactic mean value $1.8{\times}10^{20}cm^{-2}K^{-1}km^{-1}s$ at optically thick regions with E(B-V)>2.0.

  • PDF

Computational Study of the Mild Combustion and Pollutant Emission Characteristics in Wall-confined Jet (벽면으로 둘러싸인 제트 유동장에서의 마일드연소 및 오염물질 배출특성에 관한 전산해석 연구)

  • Song, Keum Mi;Oh, Chang Bo
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.263-266
    • /
    • 2012
  • The characteristics of mild combustion and pollutant emission were investigated computationally with supplied air stream temperature and dilution rate in jet flame. The air was diluted with main combustion products. As dilution rate increased at fixed air temperature, the temperature distribution of burner inside was uniformed and the maximum mole fraction of CO and NO was decreased. In addition, emission indices for NO, CO, and $CO_2$ were compared with air temperature and dilution rate.

  • PDF

Development of Classification Method for Anthracite and CO2 Emission Factor to Improve the Quality of National GHG Inventory (국가 온실가스 인벤토리 품질 향상을 위한 무연탄 분류 방법 및 배출계수 개발)

  • Kim, Seungjin;Lee, Jeongwoo;Lee, Seehyung;Sa, Jae-Hwan;Choi, Bong-Suk;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.4 no.1
    • /
    • pp.27-39
    • /
    • 2013
  • In this study, the anthracite coal being used as fuel in Korea were classified into different types. These types include the domestically produced anthracite, imported anthracite used as raw material, and imported anthracite used as fuel. Each of the calorific values and greenhouse gas emission factors were calculated. The calculation of greenhouse gas emission factors resulted in the domestically produced anthracite as $111,477{\pm}4,508kg\;CO_2/TJ$, the imported anthracite used as raw material as $108,358{\pm}4,033kg\;CO_2/TJ$, and anthracite used as fuel was displayed as $103,927{\pm}8,367kg\;CO_2/TJ$. Additionally, the amount of greenhouse gas emission based on these calculated emission factors was displayed as $6,216,942ton\;CO_2$, which resulted as 12.7% lower than the green house gas emission amount which was calculated without distinguishing anthracite coal in details. Therefore, collecting activity data through a detailed classification of anthracites facilitate a more accurate calculation of greenhouse gas emission amount compared to collecting activity data through combination. Furthermore, since the anthracite coal used domestically possesses characteristics differing from the anthracite coal proposed by the IPCC, anthracite coal should be classified for each purpose and calculated for the improvement of the national greenhouse gas inventory.