• Title/Summary/Keyword: $C_{}$ f(mean)/

Search Result 485, Processing Time 0.029 seconds

Development of Diagnostic Expert System for Rotating Machinery with Journal Bearing-Research on the Diagnosis of the Nonlinear Characteristics of Rotor System (저어널 베어링으로 지지된 회전축의 이상상태 진단을 위한 진단 전문가 시스템의 개발-로타시스템의 비선형 특성 진단을 위한 연구)

  • 유송민;김영진;박상신
    • Tribology and Lubricants
    • /
    • v.17 no.2
    • /
    • pp.153-161
    • /
    • 2001
  • The development of techniques in diagnosing the state of the system is one of the essential tools in establishing the automation and unmanned manufacturing system for the realization of CIM/FMS in the fields. In this paper, we developed various diagnostic schemes for the journal bearing supported rotor system. Up to now, vibration of the shaft, measurement of the displacement and the temperature have been used for diagnostic tools, however, the statistical features only could not differentiate the state from states. Thus, we identified the sensor data f3r the steady state in the signal processing and then applied the fuzzy c-mean technology to cope with the nonlinear characteristics of the system. This will, in return, establish a possible diagnostic system for the rotor system in the fields.

Urinary albumin excretion rate and puberty in non-diabetic children and adolescents

  • Bangstad H.J.;Jorgensen K. Dahl;Kjaersgaard P.;Mevold K.;Hanssen K.F.
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02b
    • /
    • pp.158-163
    • /
    • 1994
  • Slightly elevated urinary albumin excretion rate (microalhuminuria) is a marker of early diabectic nephropathy, but it is unclear if the established definition of microalbuminuria ($20-200{\mu}g/min$) is correct for children and adolescents. We investigated th.: albumin excretion rate, albumin/creatinine ratio and urinary albumin concentration in 150 healthy schoolchildren and adolescents to (a) obtain a reterence value for albumin excretion rate, (b) relate albumin excretion to pubertal stages and (c) evaluate albumin/creatinine ratio and morning albumin concentration as screening methods for elevated albumin excretion rate. Albumin concentration was measured by immunoturbidimetry in timed overnight urine samples. The albumin excretion showed a skewed distribution (geometric mean $3.2{\mu}g/min$, 95 percentile ($15.1{\mu}g/min$). In girls. a peak in the albumin excretion rate was found at the pubertal stage 4 (Tanner) and in boys at stage 5. Albumin/creatinine ratio of 2.5 mg/mmol as a screening level for elevated albumin excretion ($15{\mu}g/min$) showed a high positive (0.88) and negative (0.99) predictive value.

  • PDF

AraProdMatch: A Machine Learning Approach for Product Matching in E-Commerce

  • Alabdullatif, Aisha;Aloud, Monira
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.4
    • /
    • pp.214-222
    • /
    • 2021
  • Recently, the growth of e-commerce in Saudi Arabia has been exponential, bringing new remarkable challenges. A naive approach for product matching and categorization is needed to help consumers choose the right store to purchase a product. This paper presents a machine learning approach for product matching that combines deep learning techniques with standard artificial neural networks (ANNs). Existing methods focused on product matching, whereas our model compares products based on unstructured descriptions. We evaluated our electronics dataset model from three business-to-consumer (B2C) online stores by putting the match products collectively in one dataset. The performance evaluation based on k-mean classifier prediction from three real-world online stores demonstrates that the proposed algorithm outperforms the benchmarked approach by 80% on average F1-measure.

SINGULAR MINIMAL TRANSLATION GRAPHS IN EUCLIDEAN SPACES

  • Aydin, Muhittin Evren;Erdur, Ayla;Ergut, Mahmut
    • Journal of the Korean Mathematical Society
    • /
    • v.58 no.1
    • /
    • pp.109-122
    • /
    • 2021
  • In this paper, we consider the problem of finding the hypersurface Mn in the Euclidean (n + 1)-space ℝn+1 that satisfies an equation of mean curvature type, called singular minimal hypersurface equation. Such an equation physically characterizes the surfaces in the upper half-space ℝ+3 (u) with lowest gravity center, for a fixed unit vector u ∈ ℝ3. We first state that a singular minimal cylinder Mn in ℝn+1 is either a hyperplane or a α-catenary cylinder. It is also shown that this result remains true when Mn is a translation hypersurface and u is a horizantal vector. As a further application, we prove that a singular minimal translation graph in ℝ3 of the form z = f(x) + g(y + cx), c ∈ ℝ - {0}, with respect to a certain horizantal vector u is either a plane or a α-catenary cylinder.

Orbit Determination from Tracking Data of Artificial Satellite Using the Method of Differential Correction (인공위성 추적자료의 미분보정에 의한 궤도결정)

  • 이병선;조중현;박상영;최규홍;김천휘
    • Journal of Astronomy and Space Sciences
    • /
    • v.5 no.1
    • /
    • pp.31-43
    • /
    • 1988
  • The differential correction process determining osculating orbital elements as correct as possible at a given instant of time from tracking data of artificial satellite was accomplished. Preliminary orbital elements were used as an initial value of the differential correction procedure and iterated until the residual of real observation (O) and computed observation(C) was minimized. Tracking satellite was NOAA-9 or TIROS-N series. Two types of tracking data were prediction data precomputed from mean orbital elements of TBUS and real data obtained from tracking 1.70 GHz HRPT signal of NOAA-9 using 5 meter auto-track antenna in Radio Research Laboratory. Accrding to thacking data either Gause method or Herrick-Gibbs method was applied to preliminary orbit determination. In the differential correction stage we used both of the Escobal(1975)'s analytical method and numerical method using f, g series for the comparision. The results between analytical and numerical ones are nearly consistent. And the differentially corrected orbit converged to the same value in spite of the differences between preliminary orbits of each time span.

  • PDF

The luminescent characteristics of $(Y,Gd)_2O_2S$: Eu for FED (FED용 $(Y,Gd)_2O_2S$ : Eu 형광체 합성 및 발광특성에 관하여)

  • 이병호;최진일
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.3
    • /
    • pp.111-116
    • /
    • 2003
  • The red emitting phosphors for low voltage cathode luminescent, fine $(Y,Gd)_2O_2$S : Eu powders were synthesized and investigated the effect of $Gd^{3+}$as sensitizer at variety of sintering temperature. The highly intense emission line of $(Y,Gd)_2O_2$S : Eu at 627 nm is attributed in the transition from $^5D_o to ^7F_2$ energy levels. It showed the maximum value at the doping level of 5 mole% of $Gd^{3+}$at $950^{\circ}C$ of sintering temperature and then, it was degraded rapidly. The mean particle size of $(Y,Gd)_2O_2$S : Eu was obtained around 1 fm and the cathode luminescent properties of (Y,Gd)$_2$O$_2$S : Eu were better than those of $(Y,Gd)_2O_2$S : Eu.

Flexural strengths of implant-supported zirconia based bridges in posterior regions

  • Rismanchian, Mansour;Shafiei, Soufia;Nourbakhshian, Farzaneh;Davoudi, Amin
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.346-350
    • /
    • 2014
  • PURPOSE. Impact forces in implant supported FDP (fixed dental prosthesis) are higher than that of tooth supported FDPs and the compositions used in frameworks also has a paramount role for biomechanical reasons. The aim of this study was to evaluate the flexural strength of two different zirconia frameworks. MATERIALS AND METHODS. Two implant abutments with 3.8 mm and 4.5 mm platform were used as premolar and molar. They were mounted vertically in an acrylic resin block. A model with steel retainers and removable abutments was fabricated by milling machine; and 10 FDP frameworks were fabricated for each Biodenta and Cercon systems. All samples were thermo-cycled for 2000 times in $5-55^{\circ}C$ temperature and embedded in $37^{\circ}C$ artificial saliva for one week. The flexural test was done by a rod with 2 mm ending diameter which was applied to the multi-electromechanical machine. The force was inserted until observing fracture. The collected data were analyzed with SPSS software ver.15, using Weibull modulus and independent t-test with the level of significance at ${\alpha}=.05$. RESULTS. The mean load bearing capacity values were higher in Biodenta but with no significant differences (P>.05). The Biodenta frameworks showed higher load bearing capacity ($F_0=1700$) than Cercon frameworks ($F_0=1520$) but the reliability (m) was higher in Cercon (m=7.5). CONCLUSION. There was no significant difference between flexural strengths of both zirconia based framework systems; and both Biodenta and Cercon systems are capable to withstand biting force (even parafunctions) in posterior implant-supported bridges with no significant differences.

Bioequivalence and Pharmacokinetic study of Gabapentin 300mg Capsules using Liquid Chromatography-Tandem Mass Spectrometry (LC/MS/MS) in Volunteers (LC/MS/MS를 이용한 가바펜틴 300 mg 캡슐의 성인 지원자에 대한 생물학적 동등성 및 약물동태 연구)

  • Jeong, Ji-Hoon;Kwon, Jun-Tack;Yun, Hwi-Yeol;Kang, Won-Ku;Kwon, Kwang-Il
    • Korean Journal of Clinical Pharmacy
    • /
    • v.16 no.1
    • /
    • pp.63-68
    • /
    • 2006
  • Gabapentin, 1-(aminomethyl-1-cyclohexyl)acetic acid, is anew antiepileptic drug related to ${\gamma}-aminobutyric$ acid(GABA) currently being introduced in therapy worldwide. The bioavailability and pharmacokinetics of gabapentin capsules were examined in 22 volunteers who received a single oral dose in the fasting state by randomized balanced $2{\times}2$ crossover design. After dosing, blood samples were collected for a period of 24 hours and analyzed by liquid chromatography-tandem mass spectrometry (LC/MS/MS). Time course of plasma gabapentin concentration was analyzed with non-compartmental and compartmental approaches. $WinNonlin^{(R)}$, the kinetic computer program, was used for compartmental analysis. One compartment model with first-order input, first-order output with no lag time and weighting by $1/(predieted\;y)^2$ was chosen as the most appropriate pharmacokinetic model for the volunteers. The major pharmacokinetic parameters $(AUC_{0-24hr},\;AUC_{inf},\;C_{max}\;and\;T_{max})$ and other parameters $(K_a,\;K_{el},\;V_d/F\;and\;Cl/F)$ of $Gapentin^{TM}$ (test drug) and $Neurontin^{TM}$ (reference drug) were estimated by non-compartmental analysis and compartmental analysis. The 90% confidence intervals of mean difference of logarithmic transformed $AUC_{0-24hr}\;and\;C_{max}$ were $log(0.9106){\sim}log(1.l254)\;and\;log(0.8521){\sim}log(1.0505)$, respectively. It shows that the bioavailability of the test drug is equivalent with that of the reference drug. There was no statistically significant difference between the two drugs in all pharmacokinetic parameters.

  • PDF

Characteristics of Catalyst and Influence of Promoter for Hydrogen Electrode in Alkaline Fuel Cell (알칼리형 연료전지용 수소극의 촉매 특성과 조촉매의 영향)

  • Yun, Sun Ho;Lee, Hong Ki;Lee, Ju Seong
    • Applied Chemistry for Engineering
    • /
    • v.4 no.2
    • /
    • pp.373-380
    • /
    • 1993
  • The preparation method of Raney nickel catalyst and the effect of promotor for the hydrogen electrode in alkaline fuel cell were investigated with electrochemical methods. The best electrode performance was observed with the Raney nickel which was obtained at $700^{\circ}C$ of sintering temperature and 60:40 of nickel:aluminum. As titanium was added for promotor, the activity of catalyst and characteristic of electrode was improved. Especially, the electrode containing 2w/o of titanium showed the maximum mass activity of 2.4A/g and its mean particle size was $5.7{\mu}m$. The resistance and capacitance of the electrode containing 2w/o of titanium, measured with AC impedance spectroscopy, were calculated to the $0.3{\Omega}cm^2$ and $0.42F/cm^2$, respectively.

  • PDF

A Study on the Physique and Bodily Strength of the Enlisted Men of Marine Corps in Korea (일부 사형의 체격 및 체력에 관한 연구)

  • Shin, Young-Soo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.6 no.1
    • /
    • pp.87-99
    • /
    • 1973
  • The purpose of this project is offering fundamental and proper informations for the better health control and personnel management of the enlisted men of Marine corps in Korea. Survey has been done under 1,001 marine enlisted men for the purpose of understanding their condition of physique, vital capacity, and bodily strength. 1. Under the subject of physique, 7 items, body weight, chest-girth, relative body weight, relative chest-girth, Vervaeck index, and Roehrer index are listed, and under the subject of vital capacity, BTPS vital capacity and percent predicted vital capacity are listed, and under the subject of bodily strength, 7 items, grasping power, chinning-up, throwing a hanp-grenade, forward jumping, sitting-up, 100 meter sprinting, are listed. The total items are 16 and mean score of each one is as follow. 1)Physique : a. Height : $$168{\pm}0.15cm$$ b. Body weight : $$62.7{\pm}0.17kg$$ c. Chest-girth : $$91.4{\pm}0.16cm$$ d. Relative body weight : $$37.2{\pm}0.09$$ e. Relative chest-girth : $$54.3{\pm}0.10$$ f. Vervaeck index : $$91.6{\pm}0.15$$ g. Roehrer index : $$1.31{\pm}0.003$$ 2) Vital capacity : a. BTPS vital capacity : $$4470{\pm}20cc$$ b. % Predicted vital capacity : $$150{\pm}5.1%$$ 3) Bodily strength : a. Grasping power : $$41.4{\pm}0.26kg$$ b. Chinning-up : $$5.7{\pm}0.10$$ c. Throwing a hand-grenade : $$39.7{\pm}0.20m$$ d. Forward jumping : $$214{\pm}0.58cm$$ e. Sitting-up : $$19.1{\pm}0.25$$ f. Pushing-up : $$22.1{\pm}0.18$$ g. 100 meter sprinting : $$16.1{\pm}0.04sec$$. 2. Comparative analysis has been done about the conditional classes of marine enlisted men with the results of above mentioned 16 items. 7 classes according to the branches, 3 according to the ranks, 9 according to tile length of service are adopted respectively.

  • PDF