• Title/Summary/Keyword: $CO_2$ supply

Search Result 764, Processing Time 0.026 seconds

Changes of Physico-chemical Characteristic on Swine Manure Using Different Suction Strength in Composting System (돈분 퇴비화 시 공기 흡입 강도에 따른 이화학적 특성변화)

  • Lee, Dong-Jun;Kim, Jung Kon;Jeong, Kwang-Hwa;Kawg, Jung-Hoon;Ravindran, B.;Lee, Ji-Woong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.2
    • /
    • pp.59-67
    • /
    • 2017
  • The aim of this experiment was to investigate the effect of air suction rate (SR) during the composting process of swine manure mixed with sawdust used as a bulking agent. In the 25 L composting reactors, the suction rate (SR) was at four different treatment levels (100%, 200%, 300%, 400%), and were fixed on the based on constant aeration rate into the composting mixtures. The temperature reached to thermophilic phase within 2 days and it was maintained up to the $5^{th}$ day of the composting process in all reactors and then gradually decreased to room temperature at the end of the composting process. The moisture content (MC, %) of the initial mixtures was 64.27%, and it was reduced to 38.4, 33.08, 14.59 and 11.93 in the different suction rate of 100%, 200%, 300%, 400%, respectively in the end process. During the composting, the level of pH was increased from 6.83 to 8.67 and it gradually decreased to 7.56 in 100% and 200%(SR). At the same time, the pH values were reduced only up to 8.19 at 300%, and 8.08 at 400%(SR), showing that suction strengths of 100% and 200% were the better option for composting than those of 300% and 400%. The total Kjeldahl nitrogen (TKN) of initial composts mixtures was 2.3% and were changed in 3.3, 3.1, 2.5, and 2.3% at the end of the composting period from the 100%-400% (SR) variations respectively. These results also indicated that 100% and 200% (SR) were more affected by the dry mass loss as $CO_2$ and water evaporation. The initial value of C/N ratio was 25.17 and were significantly reduced to 11.88, 11.97, 14.31, and 14.72 at the end of the experiment, respectively from the 100%-400% (SR) variations. These results suggest that the suction rate (SR) of 100% and 200% relative to constant air supply would be the optimal conditions to produce high-quality compost.

Fate of inorganic nitrogen by addition of silica materials on the fresh soil condition (규산자재(珪酸資材)의 첨가(添加)에 따른 답토양중(沓土壤中) 무기태질소(無機態窒素)의 동태(動態))

  • Lee, Sang Kyu;Yu, Jin Chang;Kohno, Michiyoshi
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.8 no.2
    • /
    • pp.61-68
    • /
    • 1975
  • A laboratory study was conducted to determine the effect of nitrogen mineralization in accordance with addition of calcium silicate and wollastonite on the fresh soil condition. Results are summarized as follows. 1. Nitrogen mineralization due to application of silica materials was rapidly occured in Saweon sand soil than in Honam clay soil. Also wollastonite application more stimulated the nitrogen mineralization than calcium silicate. 2. Silica material application enhanced loss of applied nitrogen by denitrification due to accelerate the nitrification in Suweon sand soil. This tendency was more severe in calcium silicate applicated treatment than in wallasnonite applicated. 3. From these results, nitrogen should be applicated with organic matter to improve the supply of nitrogen nutrient to plant when silica materials were applied.

  • PDF

The Influence of Fermentation Conditions on the Formation of Acid and Alcohol by Some Yeast Strains (몇가지 효모(酵母)의 산(酸) 및 알콜생성(生成)에 미치는 발효조건(醱酵條件)의 영향(影響))

  • Park, Yoon-joong;Sohn, Cheon-bae
    • Korean Journal of Agricultural Science
    • /
    • v.4 no.2
    • /
    • pp.173-177
    • /
    • 1977
  • These experiments were conducted to investigate the formation of organic acid and ethanol during fermentation by three yeast strains. One of these was industrial strain (No.7) from Japan, and the others were wild types (No. 47, No. 239) isolated from Takju-mash and Strawbery, respectively. Conditions of fermentation were varied by differing the supply of oxygen (air), and by using different fermentation media The results obtained were as follows: 1) All the yeast strains produced higher amount of total organic acid and ethanol under the conditions which were aerobic, i.e. the flasks were opened during fermentation, than in case of using the flasks with fermentation bung. 2) Organic acid and ethanol were produced rapidly in the mash medium than in the semi-synthetic medium, i.e. total amount of organic acid and ethanol was maximized in a short time in the mash medium. 3) On the mash medium, the highest amount of organic acid was obtained by the strain No. 239, the next by No. 7 and the lowest by No. 47. Ethanol was produced on this medium with decreacing order of No. 47, No. 239, and No. 7. 4) The strain No. 239 was proved to be a powerful organic acid producer, yielding higher amount of organic acid especially under the aerobic conditions. 5) Above results suggests that the strain No. 239 could be of useful in alcoholic drink industry, due to its powerful ethanol-producing characteristic accompaning with high yielding of organic acids.

  • PDF

Design Guidlines of Geothermal Heat Pump System Using Standing Column Well (수주지열정(SCW)을 이용한 천부지열 냉난방시스템 설계지침)

  • Hahn, Jeong-Sang;Han, Hyuk-Sang;Hahn, Chan;Kim, Hyong-Soo;Jeon, Jae-Soo
    • Economic and Environmental Geology
    • /
    • v.39 no.5 s.180
    • /
    • pp.607-613
    • /
    • 2006
  • For the reasonable use of low grade-shallow geothermal energy by Standing Column Well(SCW) system, the basic requirements are depth-wise increase of earth temperature like $2^{\circ}C$ per every 100m depth, sufficient amount of groundwater production being about 10 to 30% of the design flow rate of GSHP with good water quality and moderate temperature, and non-collapsing of borehole wall during reinjection of circulating water into the SCW. A closed loop type-vertical ground heat exchanger(GHEX) with $100{\sim}150m$ deep can supply geothermal energy of 2 to 3 RT but a SCW with $400{\sim}500m$ deep can provide $30{\sim}40RT$ being equivalent to 10 to 15 numbers of GHEX as well requires smaller space. Being considered as an alternative of vertical GHEX, many numbers of SCW have been widely constructed in whole country without any account for site specific hydrogeologic and geothermal characteristics. When those are designed and constructed under the base of insufficient knowledges of hydrgeothermal properties of the relevant specific site as our current situations, a bad reputation will be created and it will hamper a rational utilization of geothermal energy using SCW in the near future. This paper is prepared for providing a guideline of SCW design comportable to our hydrogeothermal system.

Spatial distributions of phytoplankton community in the coastal waters of South Sea, Korea during the early summer of 2018 (2018년 이른 여름 남해 연안해역 식물플랑크톤 군집의 공간분포 특성)

  • Yoon, Yang Ho;Park, Jong Sick;Kim, Byoung Sub
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.2
    • /
    • pp.164-176
    • /
    • 2019
  • For this study, we carried out a field survey on the analysis for the spatial distributions of phytoplankton community in the eleven areas of the Korean South Sea during the early summer of 2018. The results from the study showed that the phytoplankton community consisted of 56 genera and 105 species showing by diatoms with 52.4%, dinoflagellates with 40.0% and other phytoflagellates with 7.6%. The cell density of the phytoplankton ranged from 5.5 to 593.2 cells mL-1. The species number and cell density of the phytoplankton were high in the eastern waters of the South Sea and low in the western one. The phytoplankton community showed the characteristics of being dominated by the diatoms except in the Geumpo of Namhae, Ocheon-dong of Yeosu and Oenarodo of Goheung. The dominant species of the phytoplankton community were the centric diatoms, Skeletonema costatum-like species (ls), except for the Ocheon-dong and Chungdo of Wando. However, the Ocheon-dong was dominated by toxic dinoflagellate, Gymnodinium catenatum by 41.1% dominance. On the other hand, Keumpo and Oenarodo was by dinoflagellate, Tripos fusus more than 12% dominance in the surface layer. The spatial distribution of the phytoplankton community in the coastal waters of the Korean South Sea in the early summer were determined by the supply of nutrients through precipitation.

Development of Mobile Application for Ship Officers' Job Stress Measurement and Management (해기사 직무스트레스 측정 및 관리 모바일 애플리케이션 개발)

  • Yang, Dong-Bok;Kim, Joo-Sung;Kim, Deug-Bong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.2
    • /
    • pp.266-274
    • /
    • 2021
  • Ship officers are subject to excessive job stress, which has negative physical and psychological impacts and may adversely affect the smooth supply and demand of human resources. In this study, a mobile web application was developed as a tool for systematic job stress measurement and management of officers and verified through quality evaluation. Requirement analysis was performed by ship officers and staff in charge of human resources of shipping companies, and the results were reflected in the application configuration step. The application was designed according to the waterfall model, which is a traditional software development method, and functions were implemented using JSP and Spring Framework. Performance evaluation on the user interface, confirmed that proper input and output results were implemented, and the respondent results and the database were configured in the administrator interface. The results of evaluation questionnaires for quality evaluation of the interface based on ISO/IEC 9126-2 metric were significant 4.60 for the user interface and 4.65 for the administrator interface in a 5-point scale. In the future, it is necessary to conduct follow-up research on the development of data analysis system through utilization of the collected big-data sets.

Water Physiology of Panax ginseng. 1. Habitat observation. cultural experience, weather factors and characteristics of root and leaf (인삼의 수분생리 1. 자생지관찰.재배 경험.기상요인과 근 및 엽의 특성)

  • Park, Hoon
    • Journal of Ginseng Research
    • /
    • v.4 no.2
    • /
    • pp.197-221
    • /
    • 1980
  • Habitat observation, cultural experience of old and present plantation, weather factors in relation to crop stand and water physiology of root and leaf were reviewed. According to habitat observation ginseng plants love water but plate wit talus well grow at drained place with high moisture content in air and soil while ginseng plants were not found in dry or wet place. According to cultivation experience ginseng plants require abundant water in nursery and main field but most old planters believe that ginseng plaints are draught-loving thus require little water. The experience that rain especially in summer i.e unfavorable might be due to mechanical damage of leaves arid leaf disease infection, or severe leaf fall which is caused by high air temperature and coinsided with rain. According to crop stand observation in relation to weather factors abunsant water increased each root weight but decreased total yield indicating tile increase of missing root rate. Rain in summer was unfavorable too. Though rain in June was favorable for high yield general experience that cloudy day and rain were unfavorable might be due to low light intensity under shade. Present leading planters also do loot consider the importance of water in main field. Water content is higher in top than in root and highest in central portion of root and in stem of top. For seedling the heavier the weight of root is tile higher the water content while it reveries from two years old. Water potential of intact root appeared to be -2.89 bar suggesting high sensitivity to water environment. Under water stress water content severly decreased only in leaf. Water content of leaf appeared to be 78% for optimum, below 72% for functional damage and 68% for perm anent wilting. Transpiration or curs Principally through stomata in lower side of leaf thus contribution of upper side transpiration decreased with the increase of intensity. Transpiration is greater in the leaves grown under high light intensity. Thus water content is lower with high light inte nsity under field condition indicating that light is probable cause of water stress in field. Transpiration reached maximum at 10K1ut The decrease of transpiration at higher temperature seems to be due to the decrease of stomata aperture caused by water stress. Severe decrease of photosynthesis under water stress seems to be principally due to functional damage which is not caused by high temperature and Partly due to poor CO2 supply. Water potential of leaf appeared to be -16.8 bar suggesting weakness in draught tolerance. Ginseng leaves absorb water under high humidity. Water free space of leaf disc is %mailer than that of soybean leaf and water uptake appears to be more than two steps.

  • PDF

Analysis of Research for the Actual State and Management of Automated Horticultural Facilities (경북지역 현대화 원예시설의 관리실태 조사분석)

  • 정현교;이기명;박규식
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.174-186
    • /
    • 1996
  • This study was carried out in order to understand the plan, design, constructing and actual condition of management of modernized horticultural facilities in Kyungpook Province which had been constructed from 1992 to 1995 funded by Government support. The aim of this study is to provide reference data for success of the forth project. It was performed by making up a question about driving of project and management condition of equipment after constructing. The results obtained from this study are as follows: 1. 73.5% of facilities horticulture farmhouse recognized that the prospect of greenhouse is bright, but 92.5% of the farmhouse also recognised that they need technical consultation on protected horticulture farming. Therefore, technical educations would must be enhanced about foundation of greenhouse and cultivation technique. 2. The holding times of explanatory meetings, cause of understanding to farmhouse, were one or two times in greenhouse construction, and 62.5% of the farmhouse expressed the insufficiency at the explanation and educational data. For this reason, it was judged that the construction contract had been delayed more than 5 months in 49.3% of the farmhouse after the decision of project budget. 3. In constructing after a contract, the rates of construction delay is 53.4% and defect occurrence is 41.1%. The biggest reasons of construction delay was insufficiency of worker and materials supply. Each percentage is 29.1%. And the reason of defect occurrence is badness of machinery equipment(62.9% ). 4. In management of greenhouse, a pipe-constructed plastic film greenhouse changes plastic film every one and three years because of sticking dust on plastic film. It was needed to about in cleaning technique of coverings. Because that used 3-5 years only half of the expected life span. 5. The order of broken rating in the subsidiary equipment is like this lollop ventilator (42.8%), a general control system(33.3%) especially, in the case of a general control system, the rate of all family can control is 52.7%. so, it is time to develop easy control equipment which every one could use as soon as possible. 6. When choose heat generator as decide capacity, the most priority is the mount of heat generator the percent is 45.5% heat generator and as decide model, the private purchase's percent is 77.3%. It is higher than a public bidding heat generator the percent is 22.7% heat generator when it compare with a public bidding. In the case of $CO_2$ generator, using rate is only 19.0%. The using rate is very low, so it needs education how to use depends on the way of the subsidiary equipment. 7. In the case of seedlings, it is asked to use factory-processed seedling effectively. because it's difficult to get security of labors(58.8%), hoped crops (55.9%) access same crops(29.4%) much more and changing of crops depends on market situation. that is the main reason the lack of knowhow.

  • PDF

National Policy and Status on Management of Spent Nuclear Fuel (사용후 핵연료 관리 정책과 국제 동향)

  • Park Won-Jae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.3
    • /
    • pp.285-299
    • /
    • 2006
  • At the end of 2005, 443 nuclear reactors were operating in 32 countries worldwide. They had provided about 3,000 TWh, which was just over 16 percent of global electricity supply. With the generating capacity of 368 GWe in 2004, the spent fuel generation rate worldwide, now becomes at about 11,000 tHM/y. Projections indicate that cumulative amounts to be generated by the year 2020, the time when most of the existing NPP will be closed to the end of their licensed lifetime, may be close to 445,000 tHM. In this regard, spent fuel management is a common issue in all countries with nuclear reactors. Whatever their national policy and/or strategy is selected for the backend of the nuclear fuel cycle, the management of spent fuel will contribute an impending and imminent issues to be resolved in the foreseeable future. The 2nd Review Meeting of the Contracting Parties to the Joint Convention was held in Vienna from 15 to 24 May 2006. The meeting gave an opportunity to exchange information on the national policy and strategy of spent fuel management of the Contracting Parties, to discuss their situations, prospects and the major factors influencing the national policies in this field and to identify the most important directions that national efforts and international co-operation in this area should be taken. In this paper, an overview of national and global trends of spent fuel management is discussed. In addition, some directions are identified and recent activities of each Member States in the subject area are summarized.

  • PDF

Optimal Design Method of 1-Port Surge Protective Device Based on Zinc Oxide Varistor (선화아연바리스터 기반의 1-포트 서지보호장치의 최적 설계 기법)

  • Jeong, Tae-Hoon;Kim, Young-Sung;Park, Geun-Bo;Lee, Seung-IL
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.93-102
    • /
    • 2018
  • This paper reports a Surge Protective Device (SPD) that is used to protect an automatic metering interface (AMI) power supplies of communication equipment on a low-voltage distribution system from a lightning current. The surge protective device (SPD) can be classified as one-port SPDs and two-port SPDs with decoupling elements depending on the connection type. The protection of internal systems against the lightning current may require a systematic approach consisting of coordinated SPDs. To deal with this, the definition of a lightning protection zone (LPZ) was studied and interpreted through a theoretical review. Because the lightning current resulting from a lightning surge is considerably high, there is limited protection from one SPD; therefore, coordinated cascaded MOV-based SPDs are installed to solve this problem. Regarding the power grid mentioned in this paper, a class II SPD for the low-voltage distribution system installed on the border of LPZ1 and LPZ2, which establish a protection coordination with the Arrester (LA, SA) that corresponds to the LPZO installed on the MOF stage connected to one system were designed to protect various communication (control) equipment, including the automatic meter reading system inside the branch-type electric supply panel of a building, not the incoming side of one system. In addition, performance-related tests were done by a comparison with the existing method through testing, and the optimal design was achieved for the 1-port SPD that uses a series connection and can bleed load current without any decoupling element.