• Title/Summary/Keyword: $CO_2$ supply

Search Result 768, Processing Time 0.026 seconds

A study on the characteristics for temporary ventilation of long subsea tunnels - focused on the current situation and improvement requirements (초장대 해저터널의 공사중 환기 특성에 관한 기초연구 - 현황 및 개선필요사항 중심)

  • Jo, Hyeong-Je;Chun, Kyu-Myung;Kim, Jong-Won;Lee, Ju-Kyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.153-166
    • /
    • 2015
  • Long subsea tunnel to be built below the seabed, as compared to the general railway tunnel, is subject to many restrictions in terms of spatial limitation when vertical or inclined shafts are built for the purpose of ventilation and fire safety. So, the construction of some artificial island is required to provide ventilation. But, because of construction difficulty and cost increase, it is necessary to minimize the artificial island construction. The longer ventilation distance is, the more fresh air requirement is needed. When supply airflow becomes excessive, duct size is restricted by the limitations of structure clearance and fan pressure and power increase exponentially. Therefore, in order to build a long subsea tunnel, it is necessary to overcome these practical problems and to develop technical solution that can keep the comfortable condition of tunnel environment during construction. In this study, as on ventilation method development suitable for long subsea tunnel, through comparison of temporary ventilation capacity calculation methods during construction phase, domestic and abroad, the application of Swiss SIA 196 code is found suitable for long subsea tunnel. And, through experiment on leakage of the duct connector, we confirmed that the leakage ratio per 100 m of domestic duct connection type is between 1.5~3.0%. Based on S-class duct of SIA 196 code, ventilation distance is 10.2 km, So, ventilation distance can be longer if duct connection method is improved. So, we confirmed that the improvement of leakage ratio is key issue in the construction-phase ventilation of long subsea tunnel.

A Study on Conditions for Facilitating Forest Carbon Projects for Greenhouse Gas Reduction: A Forest Management Project Case with E xtended Rotation Age in Private Forests (온실가스 감축을 위한 산림탄소사업의 이행 가능 요건에 관한 연구: 사유림 벌기령 연장형 산림경영사업을 중심으로)

  • Park, Minyoung;YOUN, Yeo-Chang
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.3
    • /
    • pp.440-452
    • /
    • 2021
  • This study identified and evaluated conditions for continued participation of private forest owners in forest carbon offset programs. The probability of continuing forest carbon offset projects, which delays greenhouse gas emissions by extending harvesting periods, increases with increasing price of carbon offset credits, public recognition of forest value, and education level. Willingness to Accept (WTA) was estimated using a Multiple Bounded Dichotomous Choice Question, which was 17,039 KRW/tCO2 for extending age to 60 years, and 23,070 KRW/tCO2 for 100 years. The following findings aim to promote participation and supply of carbon offset programs in private forests according to the study outcomes. First, introducing policies supporting private forest owners bearing opportunity costs for avoiding greenhouse gas emissions by postponing timber harvest is needed. Second, educational programs for private forest owners whose awareness of and interests in the public value of forest is necessary. Third, although having participated from the beginning of the offset program, finding ways to lead continuous participation of forest owners who are less likely to accept WTA is also necessary.

A Study on the Smoke Removal Equipment in Plant Facilities Using Simulation (시뮬레이션을 이용한 플랜트 시설물 제연설비에 관한 연구)

  • Doo Chan Choi;Min Hyeok Yang;MIn Hyeok Ko;Su Min Oh
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.40-46
    • /
    • 2024
  • Purpose: In this study, in order to ensure the evacuation safety of plant facilities, we analyze the relationship between the height of smoke removal boundary walls, the presence or absence of smoke removal equipment, and evacuation safety. Method: Using fire and evacuation simulations, evacuation safety was analyzed through changes in the height of the smoke removal boundary wall, air supply volume and exhaust volume according to vertical dista. Result: In the case of visible drawings, if only 0.6m of boundary wall is used, the time below 5m reaches the shortest, and 1.2m of boundary width is 20% longer than when using smoke removal facilities. In the case of temperature, 1.2m is 20% longer than 0.6m when only the boundary width is used without smoke removal facilities. Conclusion: It was found that increasing the length of the smoke removal boundary wall could affect visibility, and installing a smoke removal facility would affect temperature. Therefore, it is determined that an appropriate smoke removal plan and smoke removal equipment should be installed in consideration of the process characteristics.

Environmental Capacity Assessment of Busan City (부산시 환경용량평가에 관한 연구)

  • Hwang, Kyung-Yup;Hwang, Inseong;Lee, Soon-Kyu;Jo, Seung-Wu;Oh, Kwang-Joong
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.1
    • /
    • pp.79-92
    • /
    • 2006
  • Environmental capacity assessment of Busan city was conducted to provide basis for planning on sustainable development and growth of the city. Using Onish model, assessment was carried out on amenities and service facilities for the citizens of Busan city. Ecological Footprint model was used to judge if the city exceeds the its environmental capacity and to estimate the extent of the excess if it exists. The analysis using Onish model revealed that the citizens of Busan city are generally well supported by the infrastructure and service facilities of the city. Water treatment and supply facilities have enough capabilities to support the city, whereas the relatively low rate of sanitary sewer supply (78%) suggests the need for further improvement in the wastewater area. The capacities of sanitary landfills are found sufficient enough to support the city for the next 10 years. The high value for the line length served per capita in the subway sector hints on certain inconvenience of commuters. All the air quality indicators meet the Korean and WHO standards except for $NO_2$. The ecological footprint model analysis produced EF indicators for Busan city of 3.04 ha/person and 2.54 ha/person for the years of 1993 and 2003, respectively. The decrease of the indicator from 1993 to 2003 is mainly due to the incorporation of Gijang area by Busan city in 1995, suggesting the importance of the ecologically productive area in the evaluation using this model. The analysis on the ecological deficit that is based on ecologically productive land shows that the consumption by Busan city exceeds its ecologically available production by 19,600% as of 2003. The area needed to support the consumption of Busan city in 2003 is 123 times as large as the present area of Busan city, which is substantially lower than the multiplier (742) obtained for Seoul city in 1997 but is higher than those observed for Chongju city (71 in 1999) and Ulsan city (39 in 2001).

Health Risk Factors and Ventilation Improvements in Welding Operation at Large-sized Casting Process (대형 주물공정 용접작업장의 건강 위해인자 및 환기 개선)

  • Jung, Jong Hyeon;Jung, Yu Jin;Lee, Sang Man;Lee, Jung Hee;Shon, Byung Hyun;Lim, Hyun Sul
    • Clean Technology
    • /
    • v.20 no.2
    • /
    • pp.171-178
    • /
    • 2014
  • In this study we have examined the health risk factors and analyzing data of laborers working at the welding operation at large-sized casting process. In order to improve the working environment of workplace, an effective ventilation method was proposed after performing CFD (computational fluid dynamics) modeling and measurement of pollutants. As a result of examining the health risk factors of workers, oxidized steel dust is the main pollution source in the company A, welding fume in the companies B and C, and welding fume and oxidized steel dust in the company D. The fume concentration in the workers' breathing zone was $0.05{\sim}4.37mg/m^3$, and the fume concentration in the indoor air at the welding process was $0.13{\sim}7.54mg/m^3$. From a result of CFD, a local exhaust with an exhaust duct adjacent to welding point was found to be most effective in case of the exhaust process. In case of air supply, we found that a desired location of air supply fan would be at the end of the opening. If a standardizing the ventilation system for tunnel-type semi-enclosed space at a large-sized casting process is introduced in welding work places in the future, it would be more effective to protect the health of welding workers working at the casting industry and shipbuilding industry and improve the work environment.

Study on solubilization of sewage sludge using electrolysis techniques (전기분해에 의한 하수슬러지 가용 효과 연구)

  • Lee, Ji-Sun;Chang, In-Soung;Lee, Chul-Ku;Joung, Seun-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.979-984
    • /
    • 2011
  • Although sludge production has been increased due to the number of the wastewater treatment plants expanded, needs of the techniques for the sludge reduction and disposal has been issued importantly because the sludge dumping to ocean is prohibited from 2012 by the London Dumping Convention. Therefore, the sludge solubilization using electrolysis as an alternative techniques for the sludge disposal was carried out in this study. Iridium coated titanium based insoluble electrodes were used and 20 volt was applied to the electrolysis reactor using DC power supply. Supernatants of the treated sludge was monitored: The soluble COD, TN, TP of it was increased to 151%, 22% and 6% respectively. And the sludge floc size distribution was changed, that is, the flocs ranged from 0.1 to 1.0 ${\mu}m$ were increased. All of these results indicate that the cells were lysed and the internal matters bursted out of the cell after electrolysis. As well as the reduction of the sludge production, the soluble organic matters from the cells could be used as an external carbon sources in the advanced wastewater treatment plants.

Effect of Active Master Packaging System on Preservation of Fresh Shiitake Mushrooms in Supply Chain (유통과정에서 생표고버섯에 대한 Active 마스터 포장 시스템의 적용 효과)

  • An, Duck Soon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.3
    • /
    • pp.402-408
    • /
    • 2016
  • Master packaging system consists of an inner individual package and secondary outer package. During the stages of chilled transport and distribution, the combination of primary individual package and secondary package was used to maintain a modified atmosphere for shiitake mushrooms. During the retail stage at higher temperature ($25^{\circ}C$), the primary individual package was exposed to display conditions after dismantling of the secondary packaging. The master packaging system was constructed to contain eight individual $30-{\mu}m$ thick polypropylene film bags of 500 g shiitake mushrooms inside a $40-{\mu}m$ low-density polyethylene bag. Carbon dioxide absorbent material [$Ca(OH)_2$] and/or moisture absorbent (superabsorbent polymer) were designed in their required amounts based on respiration characteristics and then applied to the outer secondary packaging in sachet form. Gas concentration of the packaging, temperature, and humidity were monitored throughout transport and storage. The quality of shiitake mushrooms was measured at the retail stage to determine the packaging effect. During the distribution stage of 108 h, $O_2$ and $CO_2$ concentrations in the master packaging system were maintained at 9~11% and 1~4% in the inner packaging, respectively, which are good for quality preservation. Compared to the control, the master packaging with $CO_2$ and/or moisture absorbents improved mushroom preservation and particularly reduced decay.

Characteristics of Catalysts System of NGOC-LNT-SCR for CNG Buses (CNG 버스용 NGOC+LNT+SCR 촉매시스템의 특성)

  • Seo, Choong-Kil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.626-631
    • /
    • 2019
  • The policy-making and technological development for the supply expansion of eco-friendly automobiles has been continuing, but the internal combustion engines still accounts for about 95%. Also, in order to meet the stricter emission regulations of internal combustion engines based on fossil fuels, the proportion of after-treatments for vehicles and (ocean going) vessels is gradually increasing. This study is a basic study for the post-Euro-VI exhaust response of CNG buses, and it is to investigate the basic characteristics according to Pd substitution transition metal effect, catalyst volume effect and space velocity. A catalysts was prepared and tested using a model gas reactor. The NGOC catalyst with 3Pd exhibited the highest catalytic activity with 22% at $300^{\circ}C$, 48% at $350^{\circ}C$ and about 75% at $500^{\circ}C$. 3Co NGOC containing 3wt% of transition metal was excellent in oxidation ability, and it was small in size of 2nm, and the degree of catalyst dispersion was improved and de-NO/CO conversion was high. The volume of the NGOC-LNT-SCR catalyst system was optimal in the combination of 1.5+0.5+0.5 with a total score of 165, considering $de-CH_4/NOx$ performance and catalyst cost. For SV $14,000h^{-1}$, the $CH_4$ reduction performance was the highest at about 20%, while the SV $56,000h^{-1}$ was the lowest at about 5%. If the space velocity is small, the flow velocity decreases and the time remaining in the catalyst volume become long, so that the harmful gas was reduced.

Feasibility Study of Methanesulfonic Acid (MSA), an Alternative Lixiviant to Improve Conventional Sulfuric Acid Leaching of NCM Black Mass (NCM Black Mass 황산침출 개선을 위한 대체침출제 메탄술폰산의 적용가능성 연구)

  • Hyewon Jung;Jeseung Lee;Ganghoon Song;Minseo Park;Junmo Ahn
    • Resources Recycling
    • /
    • v.33 no.1
    • /
    • pp.58-68
    • /
    • 2024
  • Critical minerals such as nickel, cobalt and lithium, are known as materials for cathodic active materials of lithium ion batteries. The consumption of the minerals is expected to grow with increasing the demands of electric vehicles, resulting from carbon neutrality. Especially, the demand for LIB (lithium ion battery) recycling is expected to increase to meet the supply of nickel, cobalt and lithium for LIB. The recycling of EOL (end-of-life) LIB can be achieved by leaching EOL LIB using inorganic acid such as HCl, HNO3 and H2SO4, which are regarded as hazardous materials. In the present study, the potential use of MSA (Methanesulfonic acid), as an alternative lixiviant replacing sulfuric acid was investigated. In addition, leaching behaviors of NCM black mass leaching with MSA was also investigated by studying various leaching factors such as chemical concentration, leaching time, pulp density (P/D) and temperatures. The leaching efficiency of nickel (Ni), cobalt (Co), lithium (Li), and manganese (Mn) from LIB was enhanced by increasing concentration of lixiviant and reductant, leaching time and temperature. The maximum leaching of the metals was above 99% at 80℃. In addition, MSA can replace sulfuric acid to recover Ni, Co, Li, Mn from NCM black mass.

Evaluate the Effect of the Intake Manifold Geometry on Cylinder-to-cylinder Variation Using 1D-3D Coupling Analysis (1D-3D 연동해석을 통한 흡기 매니폴드 형상이 실린더별 유동 분배에 미치는 영향 평가)

  • Park, Sangjun;Cho, Jungkeun;Song, Soonho;Cho, Jayun;Wang, Taejoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.2
    • /
    • pp.161-168
    • /
    • 2016
  • CNG engine has been used as a transportation because of higher thermal efficiency and lower CO2 and particulate matter. However its out put power is decreased due to cylinder-to-cylinder variation during the supply of air-fuel mixture to the each cylinder. It also causes noise and vibration. So in this study, 1D engine simulation model was validated by comparison with experiment data and 3D CFD simulation was conducted to steady-state flow analysis about each manifold geometry. Then, the effects of various intake manifold geometries on variation were evaluated by using 1D-3D coupling analysis at engine speed of 2100 rpm range in 12 L CNG engine. As a result, variation was improved about 4 % though 3D CFD analysis and there was a variation within 3 % using 1D-3D coupling analysis.