• Title/Summary/Keyword: $CO_2$ supply

Search Result 768, Processing Time 0.041 seconds

Evaluation of the Common-management Foodservice System of the Elementary Schools in Kyungbook Region (경상북도 지역 국민학교 공동관리 급식 실태 및 영양사 직무만족도 평가)

  • 이혜상
    • Korean journal of food and cookery science
    • /
    • v.11 no.4
    • /
    • pp.370-378
    • /
    • 1995
  • This study is to seek methods for optimum management of foodservice system for elementary schools in Korea through surveying and analyzing the current status of the "common-management foodservice system" and certain important factors relating to its operations. For the survey of the current status of the "common-management foodservice system", questionnaires are prepared as against schools adopting "common-management system"("Common Schools") as well as schools adopting "conventional management system" ("Conventional Schools") in Kyungsangbookdo ("Kyungbook") area. The survey items are composed of general items, items concerning tasks of dietitians, items concerning purchasing activities and items concerning level of recognition and job-satisfaction of the dietitians. Total 46 dietitians from Common Schools and 65 dietitians from Conventional Schools in Kyungbook region responded the questionnaires. The results of this study are as follows: 1. Information Concerning Dietitians Average age of the dietitians: 26.6 yrs Ratio of two years or less of experiences as school dietitian: Dietitians from Common Schools: 59.1% Dietitians from Conventional Schools: 50.8% 2. Types of the Foodservice In both schools, rural type are prevalent; however, between urban types and islands types, the ratio of urban types are larger than the ratio of islands types in Conventional Schools, and the opposite is true in Common Schools. 3. Decision of Suppliers The ratio of dietitian's participaion in the decision making reaches only 38.3%, indicating the possibility of problems in quality control and hygienic aspects of the food supply. 4. Factor Analysis of the Foodservice Duties Food supply and general affairs administration work was carried out very well (4.2), while personnel management and operational improvement work (2.8), nutritional education work (2.3), and information related work were poorly carried out. No significant differences were found between the two types of the foodservice management systems. 5. Job Satisfaction scores of Dietitians Dietitians were more satisfied with the works (50.0), supervision (50.5) and co-workers (46.9) than pay (18.0) and promotion (22.3).

  • PDF

Effects of Operation Conditions on the Performance of Type II LiBr-H2O Absorption Heat Pump (제 2종 LiBr-H2O 흡수식 히트펌프의 운전 변수에 따른 성능 특성 수치 해석)

  • Yoon, Jun Seong;Kwon, Oh Kyung;Cha, Dong An;Bae, Kyung Jin;Kim, In Gwan;Kim, Min Soo;Park, Chan Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.7-14
    • /
    • 2017
  • This study carried out a numerical analysis of the effects of hot waste water supply on the performance of a Type II absorption heat pump. There are two types of hot waste water supply, regular series flow and reverse series flow. Also it investigated the interaction between each type of flow and heat exchange solutions. As the effectiveness of heat exchange solutions increase, the steam generation and (COP) increase as well. If the effectiveness of a heat exchange solution is lower than 0.566, the steam generation rate of the reverse flow is lower than that of the regular series flow. A high effectiveness of heat exchange solution is therefore required to make a larger amount of steam in reverse series flow than with ordinary series flow. The COP difference between the two types of flow decreases with the increasing effectiveness of the heat exchange solution. Thus, a reverse flow type absorption heat pump can match the high steam generation rate and COP of the ordinary flow type when a highly effective heat exchange solution is applied.

Geochemical Studies of $CO_2$-rich Mineral Water in the Kangwon Province (강원도지역 탄산약수의 지화학적 연구)

  • 고용권;김천수;최현수;박맹언;배대석
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.7 no.2
    • /
    • pp.73-88
    • /
    • 2000
  • The geochemistry of the $CO_2$-rich waters ($Pco_2\leq$about 1 atm) in NE part of the Kangwon province was investigated. The $CO_2$-rich waters can be divided to three types based on chemical compositions: Na-$HCO_3$, Ca-Na-$HCO_3$and Ca-$HCO_3$types. The water chemistry indicates that these type waters were evolved through reaction with host rocks by supply of deep-seated $CO_2$during deep circulation, and their geochemical environments in depth might have been different each other. The dissolution process of plagioclase is important in water/granite interactions and its solubility change according to reaction temperature played an important role in the determination of chemical compositions. The higher reaction temperature coincides with the lower different in solubility between albite and anorthite. It means that calcium is mainly released to the water in the lower temperature, whereas sodium in the higher temperature due to high Na/Ca ratio in plagioclase. The application of various chemical geothermometries on the $CO_2$-rich waters shows that the calculated reservoir temperature of Na-$HCO_3$type (about 15$0^{\circ}C$) is higher than those of Ca-$HCO_3$type. Therefore, we now interpret the recognized chemical difference was mainly due to the difference of reaction temperature. Considering normal thermal gradient, we can understand that the Na-$HCO_3$type was evolved from deeper crustal depth than the Ca-$HCO_3$type.

  • PDF

Hydrogen Supply to PEMFC for Unmanned Aero Vehicles Using Hydrolysis Reaction of NaBH4 (NaBH4 가수분해 반응에 의한 무인항공기용 PEMFC 수소공급)

  • Jung, Hyeon-Seong;Jo, Byung-Joo;Lee, Jung-Hoon;Lee, Han-Jong;Na, Il-Chai;Chu, Cheun-Ho;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.54 no.1
    • /
    • pp.11-15
    • /
    • 2016
  • Proton Exchange Membrane Fuel Cells (PEMFC) instead of batteries is appropriate for long time flight of unmanned aero vehicles (UAV). In this work, $NaBH_4$ hydrolysis system supplying hydrogen to PEMFC was studied. In order to decrease weight of $NaBH_4$ hydrolysis system, enhancement of hydrogen yield, recovery of condensing water and maintenance of stable hydrogen yield were studied. The hydrogen yield of 3.4% was increased by controlling of hydrogen pressure in hydrolysis reactor. Condensing water formed during air cooling of hydrogen was recovered into storage tank of $NaBH_4$ solution. In this process the condensing water dissolved $NaBH_4$ powder and then addition of $NaBH_4$ solution decreased system weight of 14%. $NaBH_4$ hydrolysis system was stably operated with hydrogen yield of 96% by 2.0g Co-P-B catalyst for 10 hours at 2.0L/min hydrogen evolution rate.

A numerical study on the performance of the smoke exhaust system according to the smoke exhaust method in emergency station for railway tunnel (철도터널 구난역의 제연방식에 따른 제연성능에 관한 수치 해석적 연구)

  • Ryu, Ji-Oh;Kim, Jin-Su;Seo, Jong-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.6
    • /
    • pp.845-856
    • /
    • 2017
  • In the long railway tunnel, in order to secure safety in case of fire, it is required a emergency station. However, there is no standard or research results on smoke exhaust method and exhaust flow rate in emergency station, so it is necessary to study the smoke exhaust system for emergency station. In this study, we are created a numerical analysis model for emergency station where the evacuation cross passage connected to the service tunnel or the relative tunnel was installed at regular intervals (40 m intervals). And the fire analysis are carried out by varying the fire intensity (15, 30MW), the smoke exhaust method (only air supply, forced air supply and exhaust, forced air exhaust only), and the air flow rate (7, 14, $40m^3/s$). From the results of fire analysis, temperature and CO concentration are analyzed and ASET based on the limit temperature are compared at various condition. As a result, in the case with fire intensity of 15 MW, it is shown that a sufficiently safe evacuation environment can be ensured by applying forced air supply and exhaust method or forced air exhaust only method when the air flow rate is $7m^3/s$ above. In case of fire intensity of 30 MW, it is impossible to maintain the safety evacuation environment for more than 900 seconds when the exhaust air volume is below $14m^3/s$. And when the air flow rate is $40m^3/s$, the exhaust port is disposed at the side portion of the upper duct, which is most advantageous for securing the temperature-based safety.

A study on phase change characteristics of $Ge_2Sb_2Te_5$ thin films for phase change random access memory (상변화 메모리를 위한 $Ge_2Sb_2Te_5$ 박막의 상변화 특성 연구)

  • Beak, Seung-Cheol;Song, Ki-Ho;Han, Kwang-Min;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.70-70
    • /
    • 2009
  • Si 도핑한 $Ge_2Sb_2Te_5$ 박막은 비정질상에서의 열적 안정성증가, fcc에서 hex상으로의 상전이 억제, 활성화 에너지 증가 등의 특성을 보인다. 본 연구에서는 Si 도핑에 의한 $Ge_2Sb_2Te_5$ 박막의 전기적 그리고 구조적인 특성에 관한 실험을 진행하였다. 실험에 사용된 Si 도핑 $Ge_2Sb_2Te_5$ 박막은 Si 기판 위에 radio frequency power supply를 사용해 Si과 $Ge_2Sb_2Te_5$ 타겟을 co-sputtering하여 증착하였다. Si의 sputtering 파워를 달리하여 실리콘의 농도를 다르게 증착 하였고 X-ray photoelectron spectroscopy (XPS)를 사용하여 박막의 Si 농도를 측정하였다. 증착된 박막은 질소 분위기 하에서 $5\;^{\circ}C$/min으로 열처리 하여 여러 온도와 Si 농도에서의 박막의 특성을 측정하였다. 열처리 전, 후의 박막은 X-ray diffraction (XRD) 분석을 통하여 각각의 온도에서의 구조적 특성을 분석하였다. 열처리 온도에 따르는 필름의 전기적 특성 파악을 위해서 four-point probe를 이용하여 박막의 면저항을 측정하였고 그 값은 3 회 이상 측정하여 평균값을 사용하였다. Nano-pulse scanner를 사용하여 다양한 파워범위와 펄스폭 범위에서의 박막의 상변화에 따른 반사도 차이를 측정하여 각 조성에서의 비정질-결정질상 변화속도를 분석하였다.

  • PDF

Study on Hydrogen Production and CO Oxidation Reaction using Plasma Reforming System with PEMFC (고분자 전해질 연료전지용 플라즈마 개질 시스템에서 수소 생산 및 CO 산화반응에 관한 연구)

  • Hong, Suck Joo;Lim, Mun Sup;Chun, Young Nam
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.656-662
    • /
    • 2007
  • Fuel reformer using plasma and shift reactor for CO oxidation were designed and manufactured as $H_2$ supply device to operate a polymer electrolyte membrane fuel cell (PEMFC). $H_2$ selectivity was increased by non-thermal plasma reformer using GlidArc discharge with Ni catalyst simultaneously. Shift reactor was consisted of steam generator, low temperature shifter, high temperature shifter and preferential oxidation reactor. Parametric screening studies of fuel reformer were conducted, in which there were the variations of the catalyst temperature, gas component ratio, total gas ratio and input power. and parametric screening studies of shift reactor were conducted, in which there were the variations of the air flow rate, stema flow rate and temperature. When the $O_2/C$ ratio was 0.64, total gas flow rate was 14.2 l/min, catalytic reactor temperature was $672^{\circ}C$ and input power 1.1 kJ/L, the production of $H_2$ was maximized 41.1%. And $CH_4$ conversion rate, $H_2$ yield and reformer energy density were 88.7%, 54% and 35.2% respectively. When the $O_2/C$ ratio was 0.3 in the PrOx reactor, steam flow ratio was 2.8 in the HTS, and temperature were 475, 314, 260, $235^{\circ}C$ in the HTS, LTS, PrOx, the conversion of CO was optimized conditions of shift reactor using simulated reformate gas. Preheat time of the reactor using plasma was 30 min, component of reformed gas from shift reactor were $H_2$ 38%, CO<10 ppm, $N_2$ 36%, $CO_2$ 21% and $CH_4$ 4%.

Fabrication of wide-bandgap β-Cu(In,Ga)3Se5 thin films and their application to solar cells

  • Kim, Ji Hye;Shin, Young Min;Kim, Seung Tae;Kwon, HyukSang;Ahn, Byung Tae
    • Current Photovoltaic Research
    • /
    • v.1 no.1
    • /
    • pp.38-43
    • /
    • 2013
  • $Cu(In,Ga)_3Se_5$ is a candidate material for the top cell of $Cu(In,Ga)Se_2$ tandem cells. This phase is often found at the surface of the $Cu(In,Ga)Se_2$ film during $Cu(In,Ga)Se_2$ cell fabrication, and plays a positive role in $Cu(In,Ga)Se_2$ cell performance. However, the exact properties of the $Cu(In,Ga)_3Se_5$ film have not been extensively studied yet. In this work, $Cu(In,Ga)_3Se_5$ films were fabricated on Mo-coated soda-lime glass substrates by a three-stage co-evaporation process. The Cu content in the film was controlled by varying the deposition time of each stage. X-ray diffraction and Raman spectroscopy analyses showed that, even though the stoichiometric Cu/(In+Ga) ratio is 0.25, $Cu(In,Ga)_3Se_5$ is easily formed in a wide range of Cu content as long as the Cu/(In+Ga) ratio is held below 0.5. The optical band gap of $Cu_{0.3}(In_{0.65}Ga_{0.35})_3Se_5$ composition was found to be 1.35eV. As the Cu/(In+Ga) ratio was decreased further below 0.5, the grain size became smaller and the band gap increased. Unlike the $Cu(In,Ga)Se_2$ solar cell, an external supply of Na with $Na_2S$ deposition further increased the cell efficiency of the $Cu(In,Ga)_3Se_5$ solar cell, indicating that more Na is necessary, in addition to the Na supply from the soda lime glass, to suppress deep level defects in the $Cu(In,Ga)_3Se_5$ film. The cell efficiency of $CdS/Cu(In,Ga)_3Se_5$ was improved from 8.8 to 11.2% by incorporating Na with $Na_2S$ deposition on the CIGS film. The fill factor was significantly improved by the Na incorporation, due to a decrease of deep-level defects.

Experimental Study on the Unsteady Flow Characteristics of Propellant in the Satellite (인공위성에 사용되는 추진연료의 비정상 유동특성에 관한 실험적 연구)

  • 최진철;윤효철;강신재
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.2
    • /
    • pp.39-45
    • /
    • 2000
  • A Thruster valve operates to supply fuel into thruster chamber. Very quick on-off operation of thruster valve results in unsteady flow of fuel in the propellant supplying system. Then fuel kinetic force, elastic material of propellant line, compressibility of fuel cause the flow field to pulsate. The pressure oscillation arising from resonance would damage the weak part of the thruster valve and other propellant supplying equipment. Pressure drop and fuel flowrate through propellant suppling system were measured, and pressure oscillation were triggered at the thruster valve inlet.

  • PDF

Main Bodies and Competition Structure of Distribution in Environment-friendly Agricultural Products (친환경농산물 시장의 유통주체와 경쟁구조)

  • Jeong, Eun-Mee
    • Korean Journal of Organic Agriculture
    • /
    • v.15 no.2
    • /
    • pp.151-169
    • /
    • 2007
  • By the environment-friendly(hereafter EF) agricultural policy and toward the safety food of consumers, there is much glowing supply and demand fur EF agricultural products, in Korea. But, in general, EF agricultural products are blown as unique, unreasonable and high price system. This study aims to make clare the main bodies and competition structure in EF agricultural products and the different from the agricultural products. The mail results of this study are summarized as follows. Firstly, farmers and consumers directly participate in the distribution, and the major distributors participate in the market of EF agricultural products after the certification system is got ready. Because EF agricultural products is not dealt and the price system is not built up in agricultural wholesale market. Secondly, the distribution route of EF agricultural products is organized the unified organization by the main bodies such as farmers, consumers co-op, and special distributors. In any step of distribution, the main body of distribution surely deals with the contracted farmers, consumers co-op, and special distributors. Accordingly, it is said that EF agricultural products has the competition structure between the distribution route organized the unified organization rather than between main bodies in the each steps of distribution.

  • PDF