• 제목/요약/키워드: $CO_2$ fluxes

검색결과 163건 처리시간 0.015초

이산화탄소/프로판 혼합냉매의 수평평활관 및 마이크로 핀관에서의 증발열전달에 관한 실험적 연구 (Experimental Studies on the Evaporative Heat Transfer Characteristics of CO2/Propane Refrigerant Mixtures in Horizontal Smooth and Micro-fin Tubes)

  • 조진민;김용진;김민수
    • 대한기계학회논문집B
    • /
    • 제32권4호
    • /
    • pp.290-299
    • /
    • 2008
  • Evaporation heat transfer characteristics of $CO_2$/propane mixtures in horizontal smooth and micro-fin tubes have been investigated by experiment. The experiments were carried out for several test conditions of mass fluxes, heat fluxes, compositions of $CO_2$/propane refrigerant mixtures and tube geometries. Direct heating method was used for supplying heat to the refrigerant where the test tube was uniformly heated by electric current which was applied to the tube wall. Heat transfer coefficient data during evaporation process of $CO_2$/propane mixtures were measured for 5 m long smooth and micro-fin tubes with outer diameters of 5 mm, respectively. The tests were conducted at mass fluxes of 318 to 997 $kg/m^2s$, heat fluxes of 6 to 20 $kW/m^2$ and for several mixture compositions (100/0, 75/25, 50/50, 25/75, 100/0 by wt% of $CO_2$/propane). The differences of heat transfer characteristics between smooth and micro-fin tubes for various compositions of $CO_2$/propane refrigerant mixtures and the effect of mass flux, and heat flux on enhancement factor (EF) and penalty factor (PF) were presented.

갯벌, 논 및 산림 부지에서 지표와 대기 사이의 이산화탄소 플럭스 계절/공간 변동 분석 (Seasonal and Spatial Variations of CO2 Fluxes Between Surface and Atmosphere in Foreshore, Paddy Field and Woods Sites)

  • 강동환;권병혁;유훈선;김박사;김광호
    • 한국환경과학회지
    • /
    • 제20권8호
    • /
    • pp.963-975
    • /
    • 2011
  • For this research, they were monitored $CO_2$ flux and environmental factors ($CO_2$ concentration, soil temperature, soil moisture, soil organic carbon, soil pH, soil Eh) in foreshore, paddy field and woods sites at the winter season (January 2009) and the summer season (September 2009). Seasonal and spatial variations for monitored data were analyzed, and linear regression functions of $CO_2$ flux as environmental factors were estimated. $CO_2$ fluxes averaged between surface and atmosphere monitored in foreshore and paddy field at the winter season were shown $-8\;mgCO_2m^{-2}hr^{-1}$ and $-25\;mgCO_2m^{-2}hr^{-1}$, respectively. $CO_2$ fluxes averaged between surface and atmosphere monitored in foreshore and paddy field at the summer season were shown $47\;mgCO_2m^{-2}hr^{-1}$ and $117\;mgCO_2m^{-2}hr^{-1}$, respectively. Thus, $CO_2$ was sunk from atmosphere to surface at the winter season and it was emitted from surface to atmosphere at the summer season. $CO_2$ fluxes in woods site were emitted $145\;mgCO_2m^{-2}hr^{-1}$ at the winter season and $279\;mgCO_2m^{-2}hr^{-1}$ at the summer season.

Response of Ecosystem Carbon and Water Vapor Exchanges in Evolving Nocturnal Low-Level Jets

  • Hong, Jin-Kyu;Mathieu, Nathalie;Strachan, Ian B.;Pattey, Elizabeth;Leclerc, Monique Y.
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권3호
    • /
    • pp.222-233
    • /
    • 2012
  • The nocturnal low-level jet makes a significant impact on carbon and water exchanges and turbulent mixing processes in the atmospheric boundary layer. This study reports a case study of nocturnal surface fluxes such as $CO_2$ and water vapor in the surface layer observed at a flat and homogeneous site in the presence of low-level jets (LLJs). In particular, it documents the temporal evolution of the overlying jets and the coincident response of surface fluxes. The present study highlights several factors linking the evolution of low-level jets to surface fluxes: 1) wavelet analysis shows that turbulent fluxes have similar time scales with temporal scale of LLJ evolution; 2) turbulent mixing is enhanced during the transition period of low-level jets; and 3) $CO_2$, water vapor and heat show dissimilarity from momentum during the period. We also found that LLJ activity is related not only to turbulent motions but also to the divergence of mean flow. An examination of scalar profiles and turbulence data reveal that LLJs transport $CO_2$ and water vapor by advection in the stable boundary layer, suggesting that surface fluxes obtained from the micrometeorological method such as nocturnal boundary layer budget technique should carefully interpreted in the presence of LLJs.

Contribution of Urine and Dung Patches from Grazing Sheep to Methane and Carbon Dioxide Fluxes in an Inner Mongolian Desert Grassland

  • Jiang, Yuanyuan;Tang, Shiming;Wang, Chengjie;Zhou, Pei;Tenuta, Mario;Han, Guodong;Huang, Ding
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제25권2호
    • /
    • pp.207-212
    • /
    • 2012
  • The effects of sheep urine and dung patches on methane ($CH_4$) and carbon dioxide ($CO_2$) fluxes were investigated during the summer-autumn in 2010, to evaluate their contribution to climate change in a desert grassland in Inner Mongolia, China. Results indicate that the cumulative $CH_4$ emissions for dung patches, urine patches and control plots were -0.076, -0.084, and -0.114 g/$m^2$ and these were net $CH_4$ sinks during the measured period. The level of $CH_4$ intake from urine and dung plots decreased 25.7%, and 33.3%, respectively, compared with a control plot. $CO_2$ fluxes differed (p<0.01) in urine plots, with an average of 569.20 mg/$m^2$/h compared with control plots (357.62 mg/$m^2$/h) across all sampling days. Dung patches have cumulative $CO_2$ emissions that were 15.9% higher compared with the control during the 55-d period. Overall, sheep excrement weakened $CH_4$ intake and increased $CO_2$ emissions.

경사평활관 및 마이크로핀관에서의 이산화탄소의 증발열전달 특성과 압력강하에 관한 실험적 연구 (Studies on the Evaporative Heat Transfer Characteristics and Pressure Drop of CO2 Flowing Upward in Inclined (45°) Smooth and Micro-fin Tubes)

  • 김용진;조진민;김민수
    • 대한기계학회논문집B
    • /
    • 제32권8호
    • /
    • pp.612-620
    • /
    • 2008
  • New alternative refrigerants have been developed due to the ozone layer depletion and global warming. For this reason, carbon dioxide is believed to be a promising refrigerant for use in air conditioners and heat pumps. Evaporative heat transfer characteristics and pressure drop of $CO_2$ with outer diameter of 5 mm in inclined ($45^{\circ}$) smooth and micro-fin tubes have been investigated by the experiments with respect to several test conditions such as mass fluxes, heat fluxes, evaporation temperatures in this study. The inclined ($45^{\circ}$) smooth and micro-fin tubes with length of 1.44 m were installed to measure the evaporative heat transfer coefficients of $CO_2$ and heat was supplied to the refrigerant by direct heating method where the test tube was uniformly heated by electricity. The tests were conducted at mass fluxes from 212 to $656\;kg/m^2s$, heat fluxes from 15 to $60\;kW/m^2$ and evaporation temperatures from -10 to $20^{\circ}C$. The heat transfer coefficients of $CO_2$ are slightly increased with increasing mass flux, and the heat transfer characteristics in the inclined ($45^{\circ}$) tubes are enhanced about $5{\sim}10%$ compared with those in horizontal or vertical tubes.

이어도해양과학기지에서의 에디 공분산 방법을 이용한 플럭스 관측 (Tower-based Flux Measurement Using the Eddy Covariance Method at Ieodo Ocean Research Station)

  • 이희춘;이방용;김준;심재설
    • Ocean and Polar Research
    • /
    • 제26권2호
    • /
    • pp.145-154
    • /
    • 2004
  • Surface energy and $CO_2$ fluxes have been measured over an ocean at Ieodo Ocean Research Station of KORDI since May 2003. Eddy covariance technique, which is a direct flux measurement, is used to quantitatively understand the interaction between the ocean surface and the atmospheric boundary layer. Although fluxes were continuously measured during the period from May 2003 to February 2004, the quality control of these data yielded <20% of data retrieval. The atmospheric stability did not show any distinct dirunal patterns and remained near-neutral to stable from May to June but mostly unstable during fall and winter in 2003. Sensible heat flux showed a good correlation with the difference between the sea water temperature and the air temperature. The maximum fluxes of sensible heat and latent heat were $120Wm^{-2}$ and $350Wm^{-2}$ respectively, with an averaged Bowen ratio of 0.2. The ocean around the tower absorbed $CO_2$ from the atmosphere and the uptake rates showed seasonal variations. Based our preliminary results, the daytime $CO_2$ flux was steady with an average of $-0.1 mgCO_2m^{-2}s^{-1}$ in summer and increased in winter. The nighttime $CO_2$ uptake was greater and fluctuating, reaching up to $-0.1 mgCO_2m^{-2}s^{-1}$ but these data require further examination due to weak turbulent mixing at nighttime. The magnitude of $CO_2$ flux was positively correlated with the half hourly changes in horizontal mean wind speed. Due to the paucity of quality data, further data collection is needed for more detailed analyses and interpretation.

포항 지역 토양 CO2의 분포 및 거동 특성 연구: CO2 지중저장 부지 자연 배경 조사 및 예비 해석 (Distribution and Behavior of Soil CO2 in Pohang area: Baseline Survey and Preliminary Interpretation in a Candidate Geological CO2 Storage Site)

  • 박진영;성기성;유순영;채기탁;이세인;염병우;박권규;김정찬
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제21권1호
    • /
    • pp.49-60
    • /
    • 2016
  • Distribution and behavior of baseline soil CO2 were investigated in a candidate geologic CO2 storage site in Pohang, with measuring CO2 concentrations and carbon isotopes in the vadose zone as well as CO2 fluxes and concentrations through ground surface. This investigation aimed to assess the baseline CO2 levels and to build the CO2 monitoring system before injecting CO2. The gas in the vadose zone was collected using a peristaltic pump from the depth of 60 cm below ground surface, and stored at gas bags. Then the gas components (CO2, O2, N2, CH4) and δ13CCO2 were analyzed using GC and CRDS (cavity ringdown spectroscopy) respectively in laboratory. CO2 fluxes and CO2 concentrations through ground surface were measured using Li-COR in field. In result, the median of the CO2 concentrations in the vadose zone was about 3,000 ppm, and the δ13CCO2 were in the wide range between −36.9‰ and −10.6‰. The results imply that the fate of CO2 in the vadose zone was affected by soil property and vegetations. CO2 in sandy or loamy soils originated from the respiration of microorganisms and the decomposition of C3 plants. In gravel areas, the CO2 concentrations decreased while the δ13CCO2 increased because of the mixing with the atmospheric gas. In addition, the relation between O2 and CO2, N2, and the relation between N2/O2 and CO2 implied that the gases in the vadose zone dissolved in the infiltrating precipitation or the soil moisture. The median CO2 flux through ground surface was 2.9 g/m2/d which is lower than the reported soil CO2 fluxes in areas with temperate climates. CO2 fluxes measured in sandy and loamy soil areas were higher (median 5.2 g/m2/d) than those in gravel areas (2.6 g/m2/d). The relationships between CO2 fluxes and concentrations suggested that the transport of CO2 from the vadose zone to ground surface was dominated by diffusion in the study area. In gravel areas, the mixing with atmospheric gases was significant. Based on this study result, a soil monitoring procedure has been established for a candidate geologic CO2 storage site. Also, this study result provides ideas for innovating soil monitoring technologies.

이산화탄소의 증발열전달 특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of Evaporative Heat Transfer of Carbon Dioxide)

  • 조은석;윤석호;김민수
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.38-45
    • /
    • 2002
  • Evaporative heat transfer characteristics of carbon dioxide have been investi- gated by experiment. The experiments have been carried out for a seamless stainless steel tube of the outer diameter of 9.55 mm, the inner diameter of 7.75 mm and the length of 5.0 m. Direct heating method was used for supplying heat to the refrigerant where the test tube was uniformly heated by electric current which was applied to the tube wall. Experiments were conducted with$CO_2$of purity 99.99% at saturation temperatures of 0.0 to 10.5$^{\circ}C$, heat fluxes of 12 to 27kW/$m^2$s and mass fluxes of 212 to 530 kg/$m^2$s. The heat transfer coefficients of $CO_2$are decreased as the vapor quality increases and these phenomena are explained by dimensionless Weber and Bond numbers. The heat transfer coefficients of$CO_2$increase when the heat and mass fluxes increase, and the saturation temperature effects are minor in the test range of this study. The present experimental data are compared with six renowned correlations with root-mean-squared deviations ranging from 23.0 to 94.9% respectively.

국내 벼-보리 이모작지와 벼 단작지의 탄소수지 비교 (Comparison of Carbon Budget between Rice-barley Double Cropping and Rice Mono Cropping Field in Gimje, South Korea)

  • 심교문;민성현;김용석;정명표;최인태;강기경
    • 한국농림기상학회지
    • /
    • 제18권4호
    • /
    • pp.337-347
    • /
    • 2016
  • 본 연구에서는 전라북도 김제시 부량면 신용리의 벼단작지 및 벼-보리 이모작의 논 생태계에 설치된 플럭스 관측시스템으로부터 1년간 연속적으로 관측된 $CO_2$ 플럭스 자료 및 $CH_4$ 배출량 자료를 활용하여, 논 생태계의 탄소수지를 평가하고자 하였다. 벼 단작지 및 벼-보리 이모작 논 생태계의 $CO_2$ 플럭스는 대표적인 미기상학적 방식인 에디공분산 방법을 이용하였고, $CH_4$ 발생량은 개폐형 챔버방식의 자동화 시스템을 이용하여 측정하였다. 또한, 여러 가지 기상인자(복사, 기온 및 지온 등)도 함께 조사하였다. 관측된 $CO_2$ 플럭스자료는 보정과 결측보충의 과정을 거친 후 탄소수지 분석에 활용되었다. 2014년도의 벼 단작 및 벼-보리 이모작 논 생태계의 $CO_2$의 순생태 교환량은 각각 단위면적($m^2$)당 -436.8, -587.5g C로 분석되었고, $CH_4$ 발생량은 각각 +16.04, $+18.61g\;C\;m^{-2}$로 분석되었다. 벼 재배 기간 동안 $CH_4$ 발생량은 물 관리에 따라 큰 영향을 받는 것으로 나타났는데, 담수상태에서 $CH_4$ 발생량이 배수상태보다 더 높은 것으로 분석되었다. 본 연구는 국내에서 벼 단작과 벼-보리 이모작의 논 생태계의 $CO_2$ 플럭스와 $CH_4$ 배출량을 기반으로 탄소수지를 정량화한 1차적인 연구결과로서, 벼-보리 이모작의 논 생태계가 벼 단작의 논 생태계보다 1년에 약 $128.9g\;C\;m^{-2}$를 더 흡수하는 것으로 평가되었다.

대두 개체군에 있어서 $CO_2$$O_3$ 플럭스 (Flux of Carbon Dioxide and Deposition Velocity of Ozone over Glycine max Canopy)

  • 김원식;이호준
    • The Korean Journal of Ecology
    • /
    • 제23권1호
    • /
    • pp.39-43
    • /
    • 2000
  • 1996년 7월 하순부터 9월 하순에 걸쳐 동경농공대학 농학부 부속부중농장(동경도 부중시)의 대두(Glycine max)개체군을 대상으로 미기상학적 플럭스측정방법의 하나인 열수지법을 이용하여 CO₂ 플럭스와 O₃ 플럭스를 측정하였다. CO₂ 플럭스와 O₃ 플럭스는 엽면적지수(LAI)의 변화에 영향을 받았으며, LAI가 2.0이상일 경우 CO₂ 플럭스는 광합성유효발사량(PAR)과 정비례관계가 있었다. O₃ 플럭스는 측정 기간 중 항상 양의 수치를 나타냈으며, 평균치는 0.5 mol m/sup -2/S/sup -1/이었다. 또한 CO₂와 O₃ 침착속도사이에는 정비례관계가 있었다 (LAI>2.0).

  • PDF