• 제목/요약/키워드: $CO_2$ LASER

검색결과 988건 처리시간 0.022초

A comparative evaluation of $CO_2$ and erbium-doped yttrium aluminium garnet laser therapy in the management of dentin hypersensitivity and assessment of mineral content

  • Belal, Mahmoud Helmy;Yassin, Abdulaziz
    • Journal of Periodontal and Implant Science
    • /
    • 제44권5호
    • /
    • pp.227-234
    • /
    • 2014
  • Purpose: Dentin hypersensitivity is a potential threat to oral health. Laser irradiation may provide reliable and reproducible treatment but remains controversial. The present study aimed to evaluate the effects of $CO_2$ or erbium-doped yttrium aluminium garnet (Er:YAG) laser therapy, and to assess mineral content. Methods: Eighteen human single-rooted teeth affected with advanced periodontitis were obtained. Buccal and lingual surfaces were planed to form 36 specimens. Ethylenediaminetetraacetic acid gel (24%) was applied to remove the smear layer and simulate hypersensitive teeth. The experimental groups were: group 1, control (no irradiation); group 2, $CO_2$ laser (repetitive pulsed mode, 2 W, $2.7J/cm^2$); and group 3, Er:YAG laser (slight contact mode, 40 mJ/pulse and 10 Hz). To evaluate dentinal tubule occlusion, six specimens per group (2-mm thickness) were prepared and observed using scanning electron microscopy (SEM) for calculation of the occlusion percentage. To evaluate the mineral content, six specimens per group (0.6-mm thickness) were used, and then the levels of Ca, K, Mg, Na, and P were measured by inductively coupled plasma-atomic emission spectrometry. In addition, the surface temperature of the specimens during laser irradiation was analyzed by a thermograph. Results: The SEM photomicrographs indicated melted areas around exposed dentinal tubules and a significantly greater percentage of tubular occlusion in the $CO_2$ and Er:YAG laser groups than the control, and in the Er:YAG group than the $CO_2$ laser group. In addition, no significant differences were noted among the experimental groups for the mineral elements analyzed. The $CO_2$ laser group showed an evident thermal effect compared to the Er:YAG group. Conclusions: $CO_2$ and Er:YAG laser are effective in treating dentin hypersensitivity and reducing its symptoms. However, the Er:YAG laser has a more significant effect; thus, it may constitute a useful conditioning item. Furthermore, neither $CO_2$ nor Er:YAG lasers affected the compositional structure of the mineral content.

CO2 레이저 보조가공에 의한 세라믹재료의 가공성에 관한 기초 연구 (The Basic Study on Machinability of Ceramics in CO2 Laser Assisted Machining)

  • 김종도;이수진;박서정
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권2호
    • /
    • pp.322-329
    • /
    • 2009
  • Machinability of LAM(Laser Assisted Machining) has been studied for ceramics such as $Al_2O_3$, $Si_3_N4$ and $ZrO_2$ by $CO_2$ laser. It was possible to remove ceramics by PCBN tool because material became softening and deterioration by local laser beam irradiation. The advantage of LAM is the ability to produce larger material removal rates and tool life. But, for cutting of $Al_2O_3$ and $ZrO_2$, stage of laser power control was needed owing to thermal shock with high temperature of workpiece by laser power. And when $Si_3N_4$ was machined by LAM, $N_2$ gas spouted from surface of one cause of high temperature. Characteristics of LAM were analyzed using pyrometer, dynamometer, SEM and EDS to measure temperature of workpiece surface, cutting force, variation of machining surface and structure of lattice respectively. As the result of this study, it was found that machinability of LAM for ceramics in $CO_2$ laser and mechanism of LAM was different according to the kind of ceramics because of properties of materials.

비집속빔을 이용한 $CO_2$ 레이저 빔 조사강화 ($CO_2$ Laser Irradiation Strengthening by Defocused Beam)

  • 서정;이제훈;강희신;김정오;이문용;오상진;이규현
    • 한국레이저가공학회지
    • /
    • 제6권2호
    • /
    • pp.1-7
    • /
    • 2003
  • Defocused CO$_2$ laser beam irradiation strengthening of 60kgf/$\textrm{mm}^2$ grade steel sheet was investigated to obtain the tensile strength similar to that of fully penetrated one by the focused beam. The melted line width by the defocused beam was 3∼4 times larger compared to that of the focused beam. However, the increase of tensile strength with 1 line irradiation by the defocused beam was similar to that of 2~3 lines by the focused beam. The increase(37.6%) of bending strength with 1 line by the defocused beam was higher than the increase(12.9%) of tensile strength. Also, the effect of cooling gas to strengthening was observed.

  • PDF

레이저를 이용한 회절격자 제작 및 효율 향상 연구 (Fabrication and improvement of diffraction grating with femtosecond and $CO_2$ laser)

  • 최훈국;손익부;노영철;김진태
    • 한국레이저가공학회지
    • /
    • 제15권2호
    • /
    • pp.6-10
    • /
    • 2012
  • We fabricated the diffraction grating on the surface of fused silica glass using a femtosecond laser. The grooves of diffraction grating has a lot of micro crack and debris result in reduced diffraction efficiency. So, we polished the diffraction grating with $CO_2$ laser beam. With different scan number of $CO_2$ laser beam, we observed the image of diffraction grating and measured the diffraction efficiency.

  • PDF

Comparison of complete surgical excision and minimally invasive excision using CO2 laser for removal of epidermal cysts on the face

  • Kim, Keun Tae;Sun, Hook;Chung, Eui Han
    • 대한두개안면성형외과학회지
    • /
    • 제20권2호
    • /
    • pp.84-88
    • /
    • 2019
  • Background: Epidermal cysts are benign, slow growing cysts that often develop on the head, neck, chest, and back of adults. The most common method of surgical excision involves the use of a scalpel and often leaves a scar proportional to the size of the cyst. Therefore, minimally invasive techniques are required. Among these techniques, the $CO_2$ laser-based technique is minimally invasive and has lower complication rate, shorter recovery times, and lesser scarring. This paper aimed to compare the results and postoperative complications associated with a $CO_2$ laser-based excision against conventional surgical excision for epidermal cysts. Methods: We surveyed 120 patients, aged 16 to 65 years, with epidermal cysts on the face measuring 0.5 to 2.2 cm in diameter. Twelve months later, we compared the scar length, recurrence rate, patient satisfaction, and complications between patients treated with $CO_2$ laser excision versus surgical excision. Results: The mean scar length (12 months postoperative) after $CO_2$ laser excision was $0.30{\pm}0.15cm$, and that following surgical excision was $1.23{\pm}0.43cm$ (p= 0.001). The procedure time (time from incision after local anesthesia to the end of repair) was $16.15{\pm}5.96minutes$ for $CO_2$ laser excision versus $22.38{\pm}6.05minutes$ for surgical excision (p= 0.001). The recurrence rates in the surgical excision group and $CO_2$ laser excision group were 3.3% and 8.3%, respectively; this difference was not statistically significant (p= 0.648). Conclusion: The cosmetic outcome of $CO_2$ laser excision is excellent. For epidermal cysts measuring 2.2 cm or smaller, $CO_2$ laser excision is recommended, especially when aesthetic outcome is considered important.

Co/Co+Ni 성분의 분말 소결 금속과 탄소강의 레이저 용접성에 대한 고찰 ($CO_2$ Laser Weldability Between Sintered Co, Co+Ni alloy and Carbon Steel)

  • 박종원;이창희
    • 한국레이저가공학회지
    • /
    • 제3권2호
    • /
    • pp.13-24
    • /
    • 2000
  • The weldability of dissimilar materials between sintered materials which are consisted of Co, Co+Ni and carbon steel has been investigated using CO$_2$ laser. Autogeneous CO$_2$ laser welding were run along the butt between two alloys using sets of parameters variation-power and travel speed. In order to study weldability, mechanical tests (bending strength test, microhardness test) and metallurgical analyses (microstructure, phase transformation, fracture mode) were carried out. From the results obtained, it was found that the porosity which exists in a weld metal greatly affects the soundness of the weld. The optimum energy input to have a proper strength over than the requirement by a specification, found to be around 0.3-0.35kJ/m. There are two kinds of fracture mode in the weld metal, depending upon alloy combination, brittle fracture in the case of Co-carbon steel and a ductile fracture in the case of Co+Ni-carbon steel. In general, Co+Ni sintered material showed a better weld properties as compared to the Co sintered material.

  • PDF

${\CO_2}$ 레이저에 의한 선택적 소결법 (Selective Laser Sintering by ${\CO_2}$ Laser)

  • 전병철;김재도
    • 한국정밀공학회지
    • /
    • 제15권7호
    • /
    • pp.18-25
    • /
    • 1998
  • A prototyping process based on the technique of selective ${\CO_2}$ laser sintering has been carried out using bronze powder. The integration of a ${\CO_2}$ laser and a working table to create the opto-mechanical system has been constructed for making the multi-layer sintering. Three dimensional rapid prototyping process which has used the 40W ${\CO_2}$ laser and bronze powder has been investigated experimentally The optimal scanning method has been found to minimize the deflection and distortion by using the thermal strain method which the laser scans in the x and v directions repeatedly. The method of spreading powder has been improved by using the rubber knife of which the flexibility causes less wave of spreading powder.

  • PDF

Negative branch의 불안정 공진기를 갖는 슬랩형 도파관 $CO_2$ 레이저 (The Slab Waveguide $CO_2$ Laser with Unstable Resonator of Negative Branch)

  • 김규식;우삼용;이영우;최종운
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권12호
    • /
    • pp.586-591
    • /
    • 2003
  • We have developed the radio frequency excited slab waveguide $CO_2$ laser, The dimension of active area is $2{\times}40{\times}400$ mm to get a laser gain. Two pieces of concave mirror are used to make the unstable resonator of negative branch. The radio frequency is 123 MHz and RF input power is from 100 to 900 W. The laser gas is set to a pressure of 10 ∼ 60 torr and the mixing ration is $CO_2$:$N_2$:He=1:1:3. The laser output power of 50.9 W was obtained with laser power to RF power efficiency of 6.5 %.

$CO_2$ 레이저 용접시 비드패턴에 따른 용접강도 특성 (The characteristic of strength weld according to patterns of weld bead on $CO_2$ laser welding)

  • 김태일;송영채;이문용;남기우
    • 한국레이저가공학회지
    • /
    • 제11권1호
    • /
    • pp.32-35
    • /
    • 2008
  • In the remote welding system using $CO_2$ laser, laser beam can be rapidly transferred to a workpiece by moving mirrors of scanner system. So, it makes reducing the cycle time of welding process. We can also use and apply various patterns of weld beads by linear controlled mirrors. But most of the domestic car makers have usually applied use stitch-shaped weld bead. In that case, we don't have the merit of remote welding system efficiently. Therefore, in this paper, we investigated the characteristic of weld strength according to patterns of weld bead on $CO_2$ laser welding. And we also studied the relationship between shape of weld bead and value of tensile load.

  • PDF