• Title/Summary/Keyword: $CO_2$ 모니터링

Search Result 363, Processing Time 0.027 seconds

Implement of Analysis system with Indoor Environment Monitoring Based on IoT (사물인터넷 기반 실내 환경 모니터링 분석 시스템 구현)

  • Nam, Jae-hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1687-1692
    • /
    • 2019
  • In the era of the fourth industrial revolution, advanced technologies such as the Internet of Things(IoT) and big data are emerging. However, the level of application of IoT to indoor environment is very weak. Therefore, it is necessary to develop a system for analyzing air pollutants or indoor air quality through real-time monitoring using the IoT. This paper implements a system that measures indoor environmental values using Arduino and various sensors, and stores the information obtained from various sensors into a database of server. The information stored in the server was built as a database and utilized in the ventilation system or air cleaner installed in the home or company's room. In the proposed system, it is possible to check the immediate indoor environmental condition through the LED status display of the monitoring sensor module while reducing the cost of the sensor used to implement IoT technology.

The Relationship between Arterial and End-tidal Partial Pressures of CO$_{2}$ in Halothane-anesthetized Heavy Breed Horses with respect to Operative Positions and the Modes of Ventilation (Halothane으로 마취된 거대말에서 수술자세와 호흡방법에 따른)

  • 안경아;권오경;산권명부;권구청;산안칙부
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.238-243
    • /
    • 1997
  • 체중이 700-750kg 인 4마리의 중종마에 70분동안 마취를 실시하여 동맥혈의 이 산화탄소 분압과 호기말 가스내의 이산화탄소 분압 사이의 관계를 관찰하였다. 마취도중 자발 호흡, 인공호흡 1(흡기시간 2.0초), 인공호흡 2(흡기시간 2.5초)를 각각 30분,20분,20분씩 실시하였으며 매 10분마다 동맥혈가스분석과 호기말 가스내 이산화탄소분압 측정을 실시하 였다. 동시에 혈압, 심전도, 체온측정을 실시하여 마취된 환축의 상태를 관찰하였다. 2주후에 자세를 달리하여(앙와에서 측와로) 같은 방법으로 재 실험하였다. 호기말 이산화탄소분압은 동맥혈에서보다 평균 10 mmHg 정도 낮은 양상을 보였으나 높은 상관관계를 보였으며 자세에 따른 유의적 차이는 업었다(앙와자세; r=0.949, 측와자세; r=0.920, P<0.01). 이러한 결과를 토 대로 조직에 창상을 줄 수 있는 동맥혈 가스분석 대신 비침습적방법인 호기말 가스내 이산화 탄소 분압을 측정하는 것이 환축의 모니터링에 효과적으로 사용 가능하다는 것을 알 수 있었다.

  • PDF

Development of Device Measuring Real-time Air Flow in Greenhouse (온실 공기유동 계측 시스템 개발)

  • Noh, Jae Seung;Kwon, Jinkyoung;Kim, Yu Yong
    • Journal of Bio-Environment Control
    • /
    • v.27 no.1
    • /
    • pp.20-26
    • /
    • 2018
  • This study was conducted to develop a device for measuring the air flow by space variation through monitoring program, which acquires data by each point from each environmental sensor located in the greenhouse. The distribution of environmental factors(air temperature, humidity, wind speed, etc.) in the greenhouse is arranged at 12 points according to the spatial variation and a large number of measurement points (36 points in total) on the X, Y and Z axes were selected. Considering data loss and various greenhouse conditions, a bit rate was at 125kbit/s at low speed, so that the number of sensors can be expanded to 90 within greenhouse with dimensions of 100m by 100m. Those system programmed using MATLAB and LabVIEW was conducted to measure distributions of the air flow along the greenhouse in real time. It was also visualized interpolated the spatial distribution in the greenhouse. In order to verify the accuracy of CFD modeling and to improve the accuracy, it will compare the environmental variation such as air temperature, humidity, wind speed and $CO_2$ concentration in the greenhouse.

A Study on the Design of Data Collection System for Growing Environment of Crops (작물 근권부 생장 환경 Data 수집 시스템 설계에 관한 연구)

  • Lee, Ki-Young;Jeong, Jin-Hyoung;Kim, Su-Hwan;Lim, Chang-Mok;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.6
    • /
    • pp.764-771
    • /
    • 2018
  • Domestic and foreign agricultural environments nowadays are undergoing various changes such as aging of agricultural population, increase of earned population, rapid climate change, diversification of agricultural product distribution structure, depletion of water resources and limited cultivation area. In order to respond to various environmental changes in recent agriculture, practical use of Smart Greenhouse to easily record, store and manage crop production information such as crop growing information, growth environment and agriculture work log, Interest is growing. In this paper, we propose a system that collects the situation information necessary for growth such as temperature, humidity, solar radiation, CO2 concentration, and monitor the collected data, which can be measured in the rhizosphere of the crop. We have developed a system that collects data such as temperature, humidity, radiation, and growth environment data, which are measured by data obtained from the rhizosphere measuring section of a growing crop and measured by a sensor, and transmitted to a wireless communication gateway of 400 MHz. We developed the integrated SW that can monitor the rhythm environment data and visualize the data by using cloud based data. We can monitor by graph format and data format for visualization of data. The existing smart farm managed crops and facilities using only the data within the farm, and this study suggested the most efficient growth environment by collecting and analyzing the weather and growth environment of the farms nationwide.

Development of Radiation Dosimeter using Commercial p-MOSFET (상용 p-MOSFET을 이용한 방사선 선량계 개발)

  • Lee, Nam-Ho;Choi, Young-Su;Lee, Yong-B.;Youk, Geun-Uck
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.95-101
    • /
    • 1999
  • When a metal oxide field effect transistor (MOSFET) is exposed to ionizing radiation, electron/hole pairs are generated in its oxide layer. The slow moving holes of them are trapped in the oxide layer of p-MOSFET and appear as extra charges that change the characteristics of the transistor. The radiation-induced charges directly impact the threshold (turn-on) voltage of the transistor. This paper describes the use of the radiation-induced threshold voltage change as an accumulated radiation dose monitoring sensor. Two kinds of commercial p-type MOSFETS were tested in a Co-60 gamma irradiation facility to see their capabilities as a radiation dosimeter. We found that the transistors showed good linearity in their threshold voltage shift characteristics with radiation dose. The results demonstrate the potential use of commercial p-MOSFETS as inexpensive radiation sensors for the first time.

  • PDF

Design and Implementation of a Wearable $SpO_2$ Module based WSN (무선센서네트워크 기반의 손목 착용형 $SpO_2$ 모듈 설계 및 구현)

  • Jung, Sang-Joong;Seo, Yong-Su;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.495-498
    • /
    • 2008
  • This paper describes design of a real-time, wearable reflectance pulse oximetry which is based Wireless Sensor Network. For the purpose of continuously monitoring vital signs of a human, wearable reflectance pulse oximetry is built into a wrist type that can be obtained $SpO_2$ value of patient unobtrusively. This designed $SpO_2$ module is based on a low-power 8 bit ATmega128L microcontroller operating in 3V. Low power operating $SpO_2$ module was integrated to wireless sensor node for user's health monitoring. This paper is focused on the successful integration of all these components into wearable reflectance pulse oximetry and evaluates its ability to measure patient' $SpO_2$ value. Information from this sensor was wirelessly transmitted to a base-station for storage and display purposes.

  • PDF

Monitoring of viruses in cultured walleye pollock Gadus chalcogrammmus (양성 중인 명태(Gadus chalcogrammus)의 바이러스 모니터링)

  • Nam, U-Hwa;Jeon, Chan-Hyeok;Seo, Hyun-Joon;Choi, Da-Young;Seo, Joo-young;Kwon, O-Nam;Kim, Wi-Sik;Kim, Jeong-Ho
    • Journal of fish pathology
    • /
    • v.30 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • This study was conducted to monitor the prevalence of viral hemorrhagic septicemia virus (VHSV), nervous necrosis virus (NNV) and marine birnavirus (MABV) in cultured walleye pollock Gadus chalcogrammus by RT-PCR. All of the viruses tested were not detected by one-step PCR in 62 spleen sample sets, except for NNV in one brain sample set (1/55). By two-step PCR, VHSV was detected in 51.6%(32/62) and NNV was detected in 1.6%(1/62) spleen sample set, but MABV was not detected. In the brain sample sets, the detection rate of NNV was 3.6%(2/55). VHSV and NNV were detected for the first time in cultured walleye pollock in this study. However, the titers of viruses in these sample sets are thought to be very low, because most of the positive sample sets were detected by two-step PCR and none of the fish showed any clinical symptoms of each virus. Continuous monitoring, subsequent virus isolation and validation of carrier fish will be necessary.

Monitoring of the Carbon Emission and Energy Consumption of CVD and Etcher for Semiconductor Manufacturing (반도체 제조용 CVD 및 Etcher 장비의 탄소배출량과 에너지 소비량 모니터링)

  • Ko, Dong Guk;Bae, Sung Woo;Kim, Kwang Sun;Im, Ik-Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.3
    • /
    • pp.19-22
    • /
    • 2013
  • The purpose of this study is to develop a system that can monitor the amounts of energy consumption during CVD and etching process for semiconductor manufacturing. Specifically, this system is designed to measure the $CO_2$ emission amounts quantitatively by measuring the flow rate of gas used and amount of power consumed during the processes. The processes of CVD equipment can be classified generally into processing step and cleaning step and all the two steps were monitored. In CVD and etcher equipments, various gases including Ar and $O_2$ are used, but Ar, $O_2$ and He were monitored with the use of the LCI data of Korea Environmental Industry & Technology Institute and carbon emission coefficients of EcoInvent. As a result, it was found that the carbon emission amounts of CVD equipment for Ar, $O_2$ and He were $0.030kgCO_2/min$, $4.580{\times}10^{-3}kgCO_2/min$ and $6.817{\times}10^{-4}kgCO_2/min$, respectively and those of etcher equipment for Ar and $O_2$ are $5.111{\times}10^{-3}kgCO_2/min$ and $7.172kgCO_2/min$, respectively.

The Study on Design of lead monoxide based radiation detector for Checking the Position of a Radioactive Source in an NDT (비파괴검사 분야에서 방사선원의 위치 확인을 위한 산화납 기반 방사선 검출기 설계에 관한 연구)

  • Ahn, Ki-Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.183-188
    • /
    • 2017
  • In recent years, the automatic remote control controller of the gamma ray irradiator malfunctions, and radiation workers are continuously exposed to radiation exposure accidents. In the non-destructive testing field, much time and resources are invested in establishing a radioactive source monitoring system in order to prevent potential incidents of radiation. In this study, the gamma-ray response properties of the lead monoxide-based radiation detector were estimated through monte carlo simulation as a previous study for the development of a radioactive source location monitoring system that can be applied universally to various non-destructive testing equipment. As a result of the study, the optimized thickness of the radiation detector varies according to the gamma-ray energy emitted from the radioactive source, and the optimized thickness gradually increases with increasing energy. In conclusion, the optimized thickness of the lead monoxide-based radiation detector was $200{\mu}m$ for the Ir-192, $150{\mu}m$ for the Se-75 and $300{\mu}m$ for the Co-60. Based on these results, the appropriate thickness of lead monoxide-based radiation detector considering secondary-electron equilibrium was evaluated to be $300{\mu}m$ for general application. These results can be used as a basic data for determining the appropriate thickness required in the radiation detector when developing a radiation source location monitoring system for universal application to various non-destructive testing equipment in the future.

Development of a Wireless Gamma-ray Probe for Diagnosing and Evaluation of its Effectiveness (진단용 무선 감마선 프로브 개발 및 유용성 평가)

  • Park, Hyemin;Joo, Koansik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.173-181
    • /
    • 2015
  • We developed a wireless gamma-ray probe based on radiation photon counting method to diagnose and detect remaining lesions after surgery, and its effectiveness was evaluated using calibration sources and a phantom. The probe was designed and miniaturized using a semi-conductor-based radiation sensor, and a Bluetooth remote communication module was used to implement the wireless diagnosis and detection system. Moreover, a remote monitoring system was implemented to monitor affected areas during diagnosis and surgery. To assess the effectiveness of the developed probe in this study, calibration sources $^{57}Co$, $^{133}Ba$, $^{22}Na$ and $^{137}Cs$ and a chicken breast phantom were used. Furthermore, the probe's detection response to gamma ray was confirmed through evaluation. Its clinical applicability was verified by assessing the response linearity and detection direction according to gamma-ray intensity, as well as the detection efficiency according to the depth of the gamma source in the phantom.