• Title/Summary/Keyword: ${99m}^Tc$

Search Result 1,347, Processing Time 0.03 seconds

Comparison of Inhalation Scan and Perfusion Scan for the Prediction of Postoperative Pulmonary Function (수술후 폐기능 변화의 예측에 대한 연무 흡입스캔과 관류스캔의 비교)

  • Cheon, Young-Kug;Kwak, Young-Im;Yun, Jong-Gil;Zo, Jae-Ill;Shim, Young-Mog;Lim, Sang-Moo;Hong, Sung-Woon;Lee, Choon-Taek
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.2
    • /
    • pp.111-119
    • /
    • 1994
  • Background: Because of the common etiologic factor, such as smoking, lung cancer and chronic obstructive pulmonary disease are often present in the same patient. The preoperative prediction of remaining pulmonary function after the resectional surgery is very important to prevent serious complication and postoperative respiratory failure. $^{99m}Tc$-MAA perfusion scan has been used for the prediction of postoperative pulmonary function, but it may be inaccurate in case of large V/Q mismatching. We compared $^{99m}Tc$-DTPA radioaerosol inhalation scan with $^{99m}Tc$-MAA perfusion scan in predicting postoperative lung function. Method: Preoperative inhalation scan and/or perfusion scan were performed and pulmonary function test were performed preoperatively and 2 month after operation. We predicted the postoperative pulmonary functions using the following equations. Postpneurnonectomy $FEV_1$=Preop $FEV_1x%$ of total function of lung to remain Postlobectomy $FEV_1$=Preop $FEV_1{\times}$(% of total 1-function of affected lung${\times}$$\frac{Number\;of\;segments\;to\;be\;resected}{Number\;of\;segments\;of\;affected\;lung})$ Results: 1) The inhalation scan showed good correlations between measured and predicted $FEV_1$, FVC and $FEF_{25-75%}$. (correlation coefficiency; 0.94, 0.91, 0.87 respectively). 2) The perfusion scan also showed good correlations between measured and predicted $FEV_1$, FVC and $FEF_{25-75%}$. (correlation coefficiency; 0.86, 0.72, 0.87 respectively). 3) Among three parameters, $FEV_1$ showed the best correlations in the prediction by lung scans. 4) Comparison between inhalation scan and perfusion scan in predicting pulmonary function did not show any significant differneces except FVC. Conclusion: The inhalation scan and perfusion scan are very useful in the prediction of postoperative lung function and don't make a difference in the prediction of pulmonary function a1though the former showed a better correlation in FVC.

  • PDF

Evaluation of Therapeutic Effects of Cognitive-Behavioral Therapy in Patients with Panic Disorder using Serial $^{99m}Tc-ECD$ Brain Perfusion (공황장애 환자에서 $^{99m}Tc-ECD$ 뇌관류 SPECT를 이용한 인지행동치료 효과 평가)

  • Kim, Jung-Hee;Song, Ho-Chun;Yang, Jong-Chul;Lee, Byeong-Il;Heo, Young-Jun;Bom, Hee-Seung;Park, Tae-Jin;Min, Jung-Joon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.302-308
    • /
    • 2006
  • Purpose: Although several neuroanatomical models of panic disorder have been proposed, little is known regarding the neurological mechanisms underlying cognitive-behavioral therapy (CBT) in patients with panic disorder. This study was performed to identify the brain structures that show changes of regnioal cerebral blood flow (rCBF) after CBT in patients with panic disorder. Materials and Methods: Seven patients who were diagnosed as panic disorder by DSM-IV were treated with CBT for 8 weeks and twelve healthy volunteers joined in this study. Serial $^{99m}Tc-ECD$ brain perfusion SPECT images were acquisited and PDSS-SR (Self-Report version of Panic Disorder Severity Scale) and ACQ (Agoraphobic Cognitive Question) scores were measured just before and after CBT in all patients. Data were analyzed using SPM2. Results: Subjective symptoms were improved, and PDSS-SR and ACQ scores were significantly reduced ($14.9{\pm}3.9\;vs.\;7.0{\pm}1.8$, p<0.05; $30.3{\pm}8.5\;vs.\;21.6{\pm}3.4$, p<0.05, respectively) after CBT in panic patients. Before CBT, a significant increase of rCBF was found in the cingulate gylus, thalamus, midbrain, both medial frontal and temporal lobes of the panic patients compared to the normal volunteers. After CBT, we observed a significant rCBF decrease in the left parahippocamus, right insula and cingulate gyrus, both frontal and temporal lobes, and a significant rCBF increase in both the occipital lobes, left insula, both frontal and left parietal lobes. Conclusion: These data suggested that CBT is effective for panic disorder and diminish the activity of the brain areas associated with fear in panic disorder.

Detection of Osteomyelitis Using a Tc-99m Labeled Antigranulocyte Antibody Immunoscintigraphy (Tc-99m 표지 항과립구항체 면역신티그라피를 이용한 골수염의 진단)

  • Kang, Won-Jun;Chung, June-Key;Yeo, Jeong-Seok;Hong, Mee-Kyoung;Jeong, Jae-Min;Lee, Dong-Soo;Lee, Sang-Hoon;Choi, In-Ho;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.344-353
    • /
    • 1998
  • Purpose: The purpose of this study was to evaluate the diagnostic accuracy of Tc-99m labeled antigranulocyte antibody immunoscintigrapy in the diagnosis of osteomyelitis and compare with the results of triphasic bone scan. Materials and Methods: The study population was 39 patients (22 male, 17 female) who had uncertain diagnoses of osteomyelitis. Fifteen patients had history of orthopedic surgery, and 5 had previous fracture. One milligram of monoclonal antibody against NCA-95 was labeled with 370 MBq of Tc-99m, injected intravenously, and 4 hour images were obtained. Triphasic bone scan images were obtained in 30 patients. The final diagnosis was confirmed by bacteriologic culture, biopsy or long term clinical follow up. Results: Twenty one patients were confirmed to have osteomyelitis (1 acute, 20 chronic). Eighteen patients were without osteomyelitis. Antigranulocyte antibody immunoscintigraphy had a sensitivity of 71% (15/21), and a specificity of 89% (16/18), while the sensitivity and specificity of triphasic bone scan was 93% (13/14) and 38% (6/16), respectively. Antigranulocyte antibody scan showed higher specificity of 100% (11/11) in comparison with 33% (3/9) of triphasic bone scan in patients with history of orthopedic surgery or fracture. Conclusion: Antigranulocyte antibody immunoscintigraphy is more specific than that of triphasic bone scan and may be helpful in patients with history of surgery or fracture. However, sensitivity is lower than triphasic bone scan in the detection of chronic osteomyelitis.

  • PDF

[ $^{99m}Tc-DISIDA$ ] Scintigraphic Diagnosis Of Extrahepatic Hepatocellular Carcinoma Metastasis : Comparison with Primary Hepatocellular Carcinoma ($^{99m}Tc-DISIDA$ 신티그래피를 이용한 간세포암 간외 전이의 진단 : 원발 간세포암과의 비교)

  • Chung, Soo-Kyo;Kim, Sung-Hoon;Baik, Joon-Hyun;Kim, Young-Joo;Chun, Kyung-Ah;Park, Seog-Hee;Bahk, Yong-Whee;Shin, Kyung-Sub
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.484-491
    • /
    • 1995
  • It is well known that hepatobiliary agent are taken up by metastatic hepatocellular carcinoma(HCC) as well as primary HCC. But the reported cases of the extrahepatic metastasis of HCC diagnosed by hepatobiliary scintigraphy are for the most part hematogenous ones. The relation of the uptake pattern of hepatobiliary agent in the primary and metastatic HCC is also still remains unknown. So we undertook this study to evaluate the relation of the hepatobiliary scintigraphic patterns of primary and metastatic HCC with different metastatic routes. Nine patients with primary HCC and twelve cases of metastatic HCC including four lung metastases, one bone metastasis, one right atrial metastasis, one peritoneal wall metastasis, and five lymph node metastases were studied with $^{99m}Tc-DISIDA$ scintigraphy. The images were taken on 10, 30 minutes, 1, 2, 4-6 hours. The overall detection rates of hematogenous metastases(lung and bone) is 60%(3 of 5), direct metastasis(right atrium and peritoneal wall), 100%(2 of 2) and lymphatic metastases, 0%(0 of 5). In four of five metastatic cases demonstrated with hepatobiliary scintigraphy, biliary agent is also taken up by primary HCC lesions. And the appearing time of the radioactivity in the direct metastatic HCC lesioin is same as that of primary HCC and in the cases of hematogenous metastasis, earlier than that of primary HCC. Hepatobiliary scintigraphy is more useful in the diagnosis of the metastatic HCC than primary HCC, in the cases of hematogenous and direct metastasis.

  • PDF

Perfusion Impairment in Infantile Autism on Brain SPECT Using Tc-99m ECD : Comparison with MR Findings (유아 자폐증 환아에서의 Tc-99m ECD를 이용한 뇌 단일 광전자 방출 전산화 단층 촬영술상의 관류 저하: 자기 공명 영상과의 비교 분석)

  • Ryu, Young-Hoon;Lee, Jong-Doo;Yoon, Pyeong-Ho;Kim, Dong-Ik;Oh, Young-Taik;Lee, Sun-Ah;Lee, Ho-Bun;Shin, Yee-Jin;Lee, Byung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.320-329
    • /
    • 1997
  • Neuroanatomic substrate of autism has been the subjects of continuing investigation. Because previous studies had not demonstrated consistent and specific neuroimaging findings in autism and most studies comprised adults and school-aged children, we performed a retrospective review in search of common functional and anatomical abnormalities with brain SPECT using Tc-99m ECD and correlative MRI The patient population was composed of 18 children aged 28 to 89 months(mean age : 55 months) who met the diagnostic criteria of autism as defined in the DSM-IV and CARS. Brain SPECT was performed after intravenous injection of 185-370MBq of Tc-99m ECD using brain dedicated annular crystal gamma camera. MRI was performed in all patients including T1, T2 axial and T1 sagittal sequences. SPECT data were visually assessed. Thirteen patients had abnormal SPECT scan revealing focal areas of decreased perfusion. Decreased perfusion of cerebellar vermis(12/18), cerebellar hemisphere(11/18), thalami(13/18), basal ganglia(4/18), posterior parietal(7/18), and temporal(4/18) area were noted on brain SPECT. Whereas, only 3 patients had abnormal MR findings which were subtle volume loss of parieto-occipital white matter in 3 and mild thinning of posterior body of corpus callosum in 2 and slightly decreased volume of cerebellar vermis in 1. Comparison of the numbers of abnormal findings revealed that regional cerebral blood flow (rCBF) abnormalities seen on SPECT were more numerous than anatomical abnormalities seen on MRI. In conclusion, extensive perfusion impairment involving cerebellum, thalami and parietal lobe were found in this study. SPECT may be more sensitive in reflecting pathophysiology of autism than MRI. However, further studies are mandatory to determine the significance of thalamic and parietal perfusion impairment in autism.

  • PDF

Predictive Factors of Renal Scarring in Children with Acute Urinary Tract Infection (급성 요로감염 환아의 신장 반흔 예측요인)

  • Baik, Jun-Hyun;Park, Young-Ha;Hwang, Sung-Su;Jeon, Jung-Su;Kim, Sung-Hoon;Lee, Seong-Yong;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.245-253
    • /
    • 2003
  • Puorpose: The purpose of this study was to evaluate the usefulness of $^{99m}Tc$ DMSA scintigraphy on the dignosis of a renal scar in children with urinary tract infections. Materials and Methods: Eighty three patients were included in this study, who were diagnosed as the urinary tract infection on the basis of symptom, urinalysis and urine culture. $^{99m}Tc$ DMSA scintigraphy and voiding cystoureterography were peformed within 7days before the treatment in all patients. We classified the scintigraphic findings as follow s : 1 ; a large hypoactive upper or lower pole. 2 ; a small hypoactive area. 3 ; single defect resulting in localized deformity of the outlines. 4 ; deformed outlines in a small or normal sized kidney. 5 ; multiple defects. 6 ; diffuse hypoactive kidney without regional impairment. Follow-up scintigraphy was done at least 6 months after the initial study. When the abnormality on the initial scintigraphy was not completely resolved on the follow-up scan, the lesion was defined as containing a scar. Results: One hundred and fifteen renal units of 166 units(69.3%) showed abnormal findings on the DMSA scintigraphy. 65 units(56.5%) was diagnosed as containing renal scars on follow-up scintigraphies. Incidences of renal scar among renal units showing pattern 3, 4 and 5 on the initial scan was 75%, 78% and 78%, respectively. Whereas many of renal units showing 1, 2 and 6 pattern were recovered(65%, 76%, 50%). Sensitivity, specificity and accuracy of pattern-based DMSA scintigraphic findings on the diagnosis of renal scar was 76.9%, 85.1% and 81.9%, respectively. VUR was significantly associated with the renal scar when the initial DMSA shows unrecoverable findings(pattern 3, 4, 5). Odds ratio of the renal scar in a kidney showing unrecoverable initial scintigraphic findings was 19.1. Odds ratio in a kidney with mild or moderate-to-severe VUR was 3.5 and 14.4 respectively. Conclusion: In the urinary tract infection, renal scar was significantly developed in a kidney showing unrecoverable findings on the initial DMSA scan and VUR on voiding cystoureterography.

The Study for Breast Lymphoscintigraphy of Sentinal Lymph Node in breast cancer (유방암환자 전초림프절의 유방 림프신티그라피에 관한 연구)

  • Kim, Hwa-Gon;Kim, Chang-Soo;Kim, Myung-Jun
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2006
  • In the past, most patient of breast cancer suffered side effects due to the useless removement of Axillary Lymph Node, but there is no need to remove it because of the result in this study. The purpose of this study is to save surgery time and side effects after surgical operation for patients with breast cancer by making decisions of operation range for metastasis in first Stenosis Lymph Node using the $^{99m}Tc-Tincolloid$ Scintigraphy and the Micro Probe for radioisotope. As a result of this study, 15 among 20 patients became objects of this study could reduced side effects for operation because there were no axillary lymph node operations. However there is no standard for method of this treatment. It should be standardize where inject point is, how much $^{99m}Tc-Tincolloid$ should be injected(radioactivity value), and the need of massage and Lymph Scintigraphy. Nevertheless I think that this result of study is useful to reduce suffering and side effects from breast cancer and also we should try to do that continuously. The objects for this study were 20 patients diagnosed as breast cancer by Ultrasonography, Mammography & Biopsy. The average of patient age was 45.4 years and its range was between 31 and 71 years. In case of clinical period there were 9 patients of Period I and II patients of Period III. The equipment for this study were $^{99m}Tc-Tincolloid$ describing the Stenosis Lymph Node as a tracer, Micro Probe : Neoprobe 2000(the rest is Gamma Probe) tracing the location, and MS-II Gamma Camera : SIEMENS(the rest is MS-II Gamma Camera) describing the images. There were 3 methods for this study, after selecting one of those methods all 20 patients were performed Stenosis Lymph Node diagnosis & Gamma Probe in operation room. The result was that I imaged all the 20 patients, and seek the Stenosis Lymph Node by using Gamma Probe. Metastasis in Stenosis Lymph Node was 5 and Metastasis in Axillary Lymph Node was 3 between Metastasis in Stenosis Lymph Node cases. Finally 15 patients were also proved that Axillary Lymph Node was Positive and that means there was no Metastasis in Axillary Lymph Node.

  • PDF

Evaluation of Error Factors in Quantitative Analysis of Lymphoscintigraphy (Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가)

  • Yeon, Joon-Ho;Kim, Soo-Yung;Choi, Sung-Ook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.76-82
    • /
    • 2011
  • Purpose: Lymphoscintigraphy is absolutely being used standard examination in lymphatic diagnosis, evaluation after treatment, and it is useful for lymphedema to plan therapy. In case of lymphoscintigraphy of lower-extremity lymphedema, it had an effect on results if patients had not pose same position on the examination of 1 min, 1 hour and 2 hours after injection. So we'll study the methods to improve confidence with minimized quantitative analysis errors by influence factors. Materials and Methods: Being used the Infinia of GE Co. we injected $^{99m}Tc$-phytate 37 MBq (1.0 mCi) 4 sylinges into 40 people's feet hypodermically from June to August 2010 in Samsung Medical Center. After we acquired images of fixed and unfixed condition, we confirmed the count values change by attenuation of soft tissue and bone according to different feet position. And we estimated 5 times increasing 2 cm of distance between $^{99m}Tc$ point source and detector each time to check counts difference according to distance change by different feet position. Finally, we compared 1 and 6 min lymphoscintigraphy images with same position to check the effect of quantitative analysis results owing to difference of amounts of movement of the $^{99m}Tc$-phytate in the lymphatic duct. Results: Percentage difference regarding error values showed minimum 2.7% and maximum 25.8% when comparing fixed and unfixed feet position of lymphoscintigraphy examination at 1 min after injection. And count values according to distance were 173,661 (2 cm), 172,095 (4 cm), 170,996 (6 cm), 167,677 (8 cm), 169,208 counts (10 cm) which distance was increased interval of 2 cm and basal value was mean 176,587 counts, and percentage difference values were not over 2.5% such as 1.27, 1.79, 2.04, 2.42, 2.35%. Also, Assessment results about amounts of movement in lymphatic duct within 6 min until scanning after injection showed minimum 0.15%, and maximum 2.3% which were amounts of movement. We can recognize that error values represent over 20% due to only attenuation of soft tissue and bone except for distance difference (2.42%) and amounts of movement in lymphatic duct (2.3%). Conclusion: It was show that if same patients posed different feet position on the examination of 1 min, 1 hour and 2 hours after injection in the lymphoscintigraphy which is evaluating lymphatic flow of patients with lymphedema and analyzing amount of intake by lymphatic system, maximum error value represented 25.8% due to attenuation of soft tissue and bone, and PASW (Predictive Analytics Software) showed that fixed and unfixed feet position was different each other. And difference of distance between detector and feet and change of count values by difference of examination beginning time after injection influence on quantitative analysis results partially. Therefore, we'll make an effort to fix feet position and make the most of fixing board in lymphoscintigraphy with quantitative analysis.

  • PDF

Detection and Measurement of Nuclear Medicine Workers' Internal Radioactive Contamination (핵의학과 종사자의 방사성동위원소 체내오염 측정)

  • Jeong, Gyu-Hwan;Kim, Yong-Jae;Jang, Jeong-Chan;Lee, Jai-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.123-131
    • /
    • 2009
  • Purpose: We tested a sample of nuclear medicine workers at Korean healthcare institutions for internal contamination with radioactive isotopes, measuring concentrations and evaluating doses of individual exposure. Materials and Methods: The detection and measurement was performed on urine samples collected from 25 nuclear medicine workers at three large hospitals located in Seoul. Urine samples were collected once a week, 100~200 mL samples were gathered up to 6~10 times weekly. A high-purity germanium detector was used to measure gamma radiations in urine samples for the presence of radioactive isotopes. Based on the detection results, we estimated the amounts of intake and committed effective doses using IMBA software. In cases where committed effective doses could not be adequately evaluated with IMBA software, we estimated individual committed effective doses for radionuclides with a very short half life such as $^{99m}Tc$ and $^{123}I$, using the methods recommended by International Atomic Energy Agency. Results: Radionuclides detected through the analysis of urine samples included $^{99m}Tc$, $^{123}I$, $^{131}I$ and $^{201}Tl$, as well as $^{18}F$, a nuclide used in Positron Emission Tomography examinations. The committed effective doses, calculated based on the radionuclide concentrations in urine samples, ranged from 0 to 5 mSv, but were, in the majority of cases, less than 1 mSv. The committed effective dose exceeded 1 mSv in three of the samples, and all three were workers directly handling radioactive sources. No nurses were found to have a committed effective dose in excess of 1 mSv. Conclusions: To improve the accuracy of results, it may be necessary to conduct a long-term study, performed over a time span wide enough to allow the clear determination of the influence of seasonal factors. A larger sample should also help increase the reliability of results. However, as most Korean nuclear medicine workers are currently not necessary to monitored routinely for internal contamination with radionuclides. Notwithstanding, a continuous effort is recommended to reduce any unnecessary exposure to radioactive substances, even if in inconsequential amounts, by regularly surveying workplace environments and frequently monitoring atmospheric concentrations of radionuclides.

  • PDF

A Static Scintigraphy for Imaging Aspiration Using Semi-Solid Food (반고형식을 이용한 정적 흡인 영상법)

  • Yoon, Min-Ki;Hwang, Kyung-Hoon;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.327-331
    • /
    • 2006
  • Purpose: Aspiration scintigraphy is a procedure of nuclear imaging to evaluate aspiration and of quantifying the amount of aspirate. The ultimate goal of our study is to define the correlation between aspiration and aspiration pneumonia by aspiration scintigraphy and this is a preliminary report of its trial. Materials and methods: Ten patients with positive findings by videofluoroscopy were selected. The patients ingested semi-solid food containing Tc-99m tin colloid 92.5 MBq (2.5 mCi) and images were acquired immediately after the ingestion and 3 hrs later. A fraction of aspiration to the ingested was calculated using an equation with a decay correction. Results: Five patients were interpreted positive by aspiration scintigraphy. Four patients were positive at initial images and the fractions of aspiration were 0.11%, 0.11%, 0.81%, and 0.11%. The one patient who was shown aspirated at both images had initial 5.82% and delayed 2.26%. Conclusion: Aspiration scintigraphy enables us to localize the aspiration at any desired time of the test and to quantify its amount. Follow-up studies are warranted.