• Title/Summary/Keyword: ${99m}^Tc$

Search Result 1,347, Processing Time 0.024 seconds

Clinical Evaluation of Patients with Unilateral Non-functioning Kidney on $^{99m}Tc-DMSA$ scan ($^{99m}Tc-DMSA$ 스캔에서 일측성으로 동위원소 섭취가 안되는 환아들에 대한 임상적 고찰)

  • Bae Hyun-Chul;Kim Hyun-Young;Kim Pyung-Kil;Han Sang-Won
    • Childhood Kidney Diseases
    • /
    • v.1 no.1
    • /
    • pp.31-37
    • /
    • 1997
  • The DMSA scan is a useful radiologic study in diagnosis of morphologic and functional diseases of kidney. We evaluated the distribution of sex and age, clinical manifestations, diagnosis, combined diseases, treatment and prognosis of the 61 patients with non-functioning kidney(no isotope uptake or uptake below 5% in DMSA scan) who admitted in our hospital from 1980 to 1995. The proportion of patients under 1 year old age was 46%. Sex ratio was 1.4:1 with male predominance. Most diagnosis of non-functioning kidneys were congenital such as multicystic dysplastic kidney, hydronephrosis due to ureteropelvic junction obstruction, renal agenesis and renal hypoplasia. In order of frequency thirty one percent of them were previously detected on antenatal ultrasonogram. Treatment consisted of operation in 47.5%, mostly nephrectomy and 32.8% of patients were followed up at OPD base without definite treatment. The most common combined diseases was hydronephrosis, in 4patients who had both kidneys inveloved progressed to chronic renal failure, but the prognosis in most cases were good. It is important to evaluate renal diseases in perinatal periods, and we believe that highly sensitive diagnostic study contribute to early treatment plan and thus to good prognosis.

  • PDF

The Variation of Scan Time According to Patient's Breast Size and Body Mass Index in Breast Sentinel lymphangiography (유방암의 감시림프절 검사에서 유방크기와 체질량지수에 따른 검사시간 변화)

  • Lee, Da-Young;Nam-Koong, Hyuk;Cho, Seok-Won;Oh, Shin-Hyun;Im, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.62-67
    • /
    • 2012
  • Purpose : At this time, the sentinel lymph node mapping using radioisotope and blue dye is preceded for breast cancer patient's sentinel lymph node biopsy. But all patients were applied the same protocol without consideration of physical specific character like the breast sizes and body mass indexes. The purpose of this study is search the optimized scan time in breast sentinel lymphangiography by observing how much the body mass index and breast size influence speed of lymphatic flow. Materials and Methods : The Object of this study was 100 breast cancer patients(Female, 100 persons, average age $50.34{\pm}10.26$ years old)at Severance hospital from October 2011 to December 2011. They were scanned breast sentinel lymphangiography before operation. This study was performed on Forte dual heads gamma camera (Philips Medical Systems, Nederland B.V.). All patients were intra-dermal injected $^{99m}Tc$-Phytate 18.5 MBq, 0.5 ml. For 80 patients, we have scanned without limitation of scan time until the lymphatic flow from the lymph node since injection. We measured how long the lymphatic flow time between departures from injects site and arrival to lymph node using stopwatch. After we calculated patient's Body mass Index and classified as 4 groups. And we measured patient's breast size and classified 3 groups. The modified breast lymphangiography that changing scan time according to comparison study's result was performed on 20 patients and was estimated. Results : The mean scan time as breast size was A group 2.48 minutes, B group 7.69 minutes, C group 10.43 minutes. The mean scan time as body mass index was under weight 1.35 minutes, normal weight 2.56 minutes, slightly over 5.62 minutes, over weighted 5.62 minutes. The success rate of modified breast lymphangiography was 85%. Conclusion : As the Body mass index became higher and breast size became bigger, the total scan time is increased. Based on the obtained information, we designed modified breast lymphangiography protocol. At the cases applying that protocol, most of sentinel lymph nodes were visualized as lymphatic pool. In conclusion, we found that the more success rate in modified protocol considering physical individuality than study carrying out in the same protocol.

  • PDF

Traffic Forecasting Model Selection of Artificial Neural Network Using Akaike's Information Criterion (AIC(AKaike's Information Criterion)을 이용한 교통량 예측 모형)

  • Kang, Weon-Eui;Baik, Nam-Cheol;Yoon, Hye-Kyung
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.7 s.78
    • /
    • pp.155-159
    • /
    • 2004
  • Recently, there are many trials about Artificial neural networks : ANNs structure and studying method of researches for forecasting traffic volume. ANNs have a powerful capabilities of recognizing pattern with a flexible non-linear model. However, ANNs have some overfitting problems in dealing with a lot of parameters because of its non-linear problems. This research deals with the application of a variety of model selection criterion for cancellation of the overfitting problems. Especially, this aims at analyzing which the selecting model cancels the overfitting problems and guarantees the transferability from time measure. Results in this study are as follow. First, the model which is selecting in sample does not guarantees the best capabilities of out-of-sample. So to speak, the best model in sample is no relationship with the capabilities of out-of-sample like many existing researches. Second, in stability of model selecting criterion, AIC3, AICC, BIC are available but AIC4 has a large variation comparing with the best model. In time-series analysis and forecasting, we need more quantitable data analysis and another time-series analysis because uncertainty of a model can have an effect on correlation between in-sample and out-of-sample.

A Low-Dose High-Resolution SPECT System with CdTe for Small-Animal Imaging Applications: A GATE Simulation Study (GATE 시뮬레이션을 통한 고해상도 저선량용 소동물 영상화를 위한 CdTe 검출기 기반의 SPECT 기기 연구)

  • Park, Su-Jin;Yu, A Ram;Kim, Yeseul;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.162-170
    • /
    • 2013
  • Dedicated single-photon emission computed tomography (SPECT) systems based on pixelated semiconductors are being developed for studying small animal models of human disease. To clarify the possibility of using a SPECT system with CdTe for a high resolution low-dose small animal imaging, we compared the quality of reconstructed images from pixelated CdTe detector to those from a small SPECT system with NaI(Tl). The CdTe detector was $44.8{\times}44.8$ mm and the pixels were $0.35{\times}0.35{\times}5$ mm. The intrinsic resolution of the detector was 0.35 mm, which is equal to the pixel size. GATE simulations were performed to assess the image quality of both SPECT systems. The spatial resolutions and sensitivities for both systems were evaluated using a 10 MBq $^{99m}Tc$ point source. The quantitative comparison with different injected dose was performed using a voxelized MOBY phantom, and the absorbed doses for each organ were evaluated. The spatial resolution of the SPECT with NaI(Tl) was about 1.54 mm FWHM, while that of the SPECT with a CdTe detector was about 1.32 mm FWHM at 30 mm. The sensitivity of NaI(Tl) based SPECT was 83 cps/MBq, while that of the CdTe detector based SPECT was 116 cps/MBq at 30 mm. The image statistics were evaluated by calculating the CNR of the image from both systems. When the injected activity for the striatum in the mouse brain was 160 Bq/voxel, the CNR of CdTe based SPECT was 2.30 while that of NaI(Tl) based SPECT was 1.85. The CNR of SPECT with CdTe was overall higher than that of the NaI(Tl) based SPECT. In addition, the absorbed dose was higher from SPECT with CdTe than those from NaI(Tl) based SPECT to acquire the same quantitative values. Our simulation results indicated that the SPECT with CdTe detector showed overall high performance compared to the SPECT with NaI(Tl). Even though the validation study is needed, the SPECT system with CdTe detector appeared to be feasible for high resolution low-dose small animal imaging.

Development of Automated Region of Interest for the Evaluation of Renal Scintigraphy : Study on the Inter-operator Variability (신장 핵의학 영상의 정량적 분석을 위한 관심영역 자동설정 기능 개발 및 사용자별 분석결과의 변화도 감소효과 분석)

  • 이형구;송주영;서태석;최보영;신경섭
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.41-50
    • /
    • 2001
  • The quantification analysis of renal scintigraphy is strongly affected by the location, shape and size of region of interest(ROI). When ROIs are drawn manually, these ROIs are not reproducible due to the operators' subjective point of view, and may lead to inconsistent results even if the same data were analyzed. In this study, the effect of the ROI variation on the analysis of renal scintigraphy when the ROIs are drawn manually was investigated, and in order to obtain more consistent results, methods for automated ROI definition were developed and the results from the application of the developed methods were analyzed. Relative renal function, glomerular filtration rate and mean transit time were selected as clinical parameters for the analysis of the effect of ROI and the analysis tools were designed with the programming language of IDL5.2. To obtain renal scintigraphy, $^{99m}$Tc-DTPA was injected to the 11 adults of normal condition and to study the inter-operator variability, 9 researchers executed the analyses. The calculation of threshold using the gradient value of pixels and border tracing technique were used to define renal ROI and then the background ROI and aorta ROI were defined automatically considering anatomical information and pixel value. The automatic methods to define renal ROI were classified to 4 groups according to the exclusion of operator's subjectiveness. These automatic methods reduced the inter-operator variability remarkably in comparison with manual method and proved the effective tool to obtain reasonable and consistent results in analyzing the renal scintigraphy quantitatively.

  • PDF

Effect of ST 36-ST 41 Electro-acupuncture on Regional Cerebral Blood Flow in Normal Volunteers Evaluated by $^{99m}Tc$-ECD SPECT (족삼리-해계 전침치료가 정상인의 국소 뇌혈류에 미치는 영향 -Brain SPECT와 SPM을 이용하여-)

  • Moon, Sang-Kwan;Min, In-Kyu;Park, Sung-Uk;Jung, Woo-Sang;Park, Jung-Mee;Ko, Chang-Nam;Cho, Ki-Ho;Bae, Hyung-Sup;Kim, Young-Suk;Kim, Deok-Yoon
    • The Journal of Korean Medicine
    • /
    • v.31 no.1
    • /
    • pp.130-137
    • /
    • 2010
  • Objectives: So far it has been reported that acupuncture increases cerebral blood supply and stimulates the functional activity of brain nerve cells. Previous studies have demonstrated that frequently used electro-acupuncture (EA) therapies for stroke increased regional cerebral blood flow (rCBF) in normal volunteers. Though ST 36-ST 41 EA is another prevailing therapy for stroke, there had been no report about its effect on rCBF. This study was to evaluate the effect of ST 36-ST 41 EA on rCBF in normal volunteers using single photon emission computed tomography (SPECT) and statistical parametric mapping (SPM). Methods: In the resting state, $^{99m}Tc$-ECD brain SPECT scans were performed on 10 normal volunteers (5 males, 5 female, mean age $23.6{\pm}0.5$ years). On the other study day, 7 days after the resting examination, 15 minutesEA were applied at ST 36 and ST 41 on the right side of the subjects. Immediately after ST36-ST41 EA, the second SPECT images were obtained in the same manner as the resting state. Significant increases and decreases of rCBF after EA were estimated by comparing their SPECT images with those of the resting state using paired t statistics at every voxel, which were analyzed by SPM with a threshold of p = 0.01, uncorrected (extent threshold: k=100 voxels). Results: EA applied at the right ST36-ST41 significantly increased rCBF in the right inferior parietal lobule (Brodmann area [BA] 40), right retrosubicular area (BA 48), left inferior parietal lobule (BA 40), left middle temporal gyrus (BA 21), left fusiform gyrus (BA 37), left inferior parietal lobule (BA 39), left inferior temporal gyrus (BA 20), and left somatosensory association cortex (BA 7). However, right ST36-ST41 EA significantly decreased rCBF in the right parahippocampal gyrus (BA 35), right cerebellum, left frontopolar area (BA 10), left orbitofrontal area (BA 11), left dorsolateral prefrontal cortex (BA 9), and left dorsal anterior cingulate cortex (BA 32). Conclusions: These results demonstrate that rightST36-ST41 EA increased rCBF prominently in both inferior parietal lobule (BA 40) and right retrosubicular area (BA 48), which suggest that there be correlation between specific EA and corresponding rCBF.

A Study on Scenario to establish Coastal Inundation Prediction Map due to Storm Surge (폭풍해일에 의한 해안침수예상도 작성 시나리오 연구)

  • Moon, Seung-Rok;Kang, Tae-Soon;Nam, Soo-Yong;Hwang, Joon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.5
    • /
    • pp.492-501
    • /
    • 2007
  • Coastal disasters have become one of the most important issues in every coastal country. In Korea, coastal disasters such as storm surge, sea level rise and extreme weather have placed many coastal regions in danger of being exposed or damaged during subsequent storms and gradual shoreline retreat. A storm surge is an onshore gush of water associated with a tow pressure weather system, typically in typhoon season. However, it is very difficult to predict storm surge height and inundation due to the irregularity of the course and intensity of a typhoon. To provide a new scheme of typhoon damage prediction model, the scenario which changes the central pressure, the maximum wind radius, the track and the proceeding speed by corresponding previous typhoon database, was composed. The virtual typhoon scenario database was constructed with individual scenario simulation and evaluation, in which it extracted the result from the scenario database of information of the hereafter typhoon and information due to climate change. This virtual typhoon scenario database will apply damage prediction information about a typhoon. This study performed construction and analysis of the simulation system with the storm surge/coastal inundation model at Masan coastal areas, and applied method for predicting using the scenario of the storm surge.

Absolute Renal $^{99m}Tc-DMSA$ Uptake and Renal Scan in Children with Vesicoureteral Reflux (방광요관역류를 가진 소아의 DMSA 스캔과 절대 신섭취율의 평가)

  • Bae, Sang-Kyun;Lee, Dong-Soo;Yang, Hyung-In;Choi, Chang-Woon;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Choi, Yong;Kim, Gwang-Myung;Choi, Hwang;Yeon, Kyung-Mo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.327-332
    • /
    • 1992
  • $^{99m}Tc-dimercaptosuccinic$ acid (DMSA) 주사후 일정시간에 측정한 절대적 신섭취량은 기능이 살아있는 신피질량과 관계있다. 소아의 신기능은 출생후 계속 성숙되어 생후 약 $1\sim2$년에 성인의 기능에 도달하는데 DMSA섭취도 성인과는 다른 양상을 보일 것으로 기대되며 신질환에서 절대적 신섭취율의 평가는 연령을 고려해야 할 것이다. 저자들은 DMSA 스캔을 시행한 소아 환자를 대상으로 스캔상 피질 결손이 없으며 양측신의 섭취율이 비슷하고 혈중 크레아티닌치가 정상인 경우를 대조군으로 하여 연령별 DMSA의 절대적 신섭취율을 구하였고 방광요관역류를 가진 환아를 대상으로 DMSA스캔을 시행하고 신섭취율을 조사하였다. 1) 대조군은 모두 65명으로 좌우측 신섭취율의 유의한 차이는 없었으며 연령에 따라 2세경에 플라토에 도달하였는데 한쪽 신장의 평균섭취율은 3개월 미만이 $14.5{\pm}3.1%$ ID, 3개월에서 6개월 미만이 $17.2{\pm}2.1%$ID, 6개월에서 1년 미만이 $18.4{\pm}1.3%$ID, 1년에서 1년6개월 미만이 $19.3{\pm}1.1%$ID, 1년 6개월에서 2년 미만이 $21.9{\pm}2.0%$ID, 2세이상 15세이하가 $20.1{\pm}0.6%$ID였으며 전체 평균섭취율은 $19.4{\pm}0.5%$ID (injected dose, $mean{\pm}S.E.$)였다. 2) 방광요관역류를 가진 환아는 55명 (일측성 56명, 양측성 29명)으로 109신장을 대상으로 하였다. 방광요관역류의 정도와 피질결손의 수와는 대체로 비례관계가 있었으나 방광요관역류가 없으면서 피질결손이 있는 경우가 25신장중 2예 (8%)였으며, 방광요관역류가 있는 84신장중 27예 (32.1%), 이중에서 방광요관역류가 3도 이상인 62신장중 13예 (21%)에서는 피질결손이 없었다. 3) 이환신의 DMSA 섭취율을 연령에 따른 대조군의 섭취율에 대한 비(섭취율비)로 나타내면 한쪽에 역류가 있을 때 이환신의 경우 $0.55{\pm}0.06$, 정상신의 경우 $1.34{\pm}0.05$이었으며, 양쪽에 역류가 있을 때는 평균 $0.82{\pm}0.08$ $(mean{\pm}S.E.)$ 이었다. 4) 피질결손이 있는 신장의 절대 DMSA 신섭취율은 감소되어 있었고 상대측 신장의 섭취율은 피질 결손이 있더라도 대상적인 증가의 경향을 보였다. 이상의 결과로 소아에서 DMSA 절대적 신섭취율의 연령에 따른 변화를 알 수 있었으며 방광요관역류의 정도와 피질결손의 정도가 반드시 비례하지만은 않아서 시간경과에 따른 추후 검사가 필요하리라 생각된다. 또한 방광요관역류가 있는 환아에서 DMSA 섭취율로 신기능을 평가할 때, 특히 영유아에서 연령에 따른 고려가 있어야 할 것으로 보인다.

  • PDF

Clinical Significance of Myocardial Uptake on F-18 FDG PET/CT Performed in Oncologic Patients (종양 환자의 F-18 FDG PET/CT에서 관찰된 심근 섭취의 임상적 의미)

  • Cho, Ho-Jin;Cho, Arthur;Lee, Jong-Doo;Kang, Won-Jun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.519-525
    • /
    • 2009
  • Purpose: F-18 fluorodeoxyglucose (FDG) uptake of myocardium is influenced by various factors. Increased glycolysis, and subsequent increased F-18 FDG uptake has been reported in ischemic cardiomyopathy. However, clinical significance of incidentally found myocardial F-18 FDG uptake has not been clarified. We retrospectively reviewed the degree and pattern of myocardial uptake in patients without history of ischemic heart disease who underwent torso F-18 FDG PET/CT for evaluation of neoplastic disease. Materials and Methods: From January 2005 to June 2009, 77 patients who underwent F-18 FDG PET/CT and Tc-99m sestamibi stress/rest SPECT within 3 months were enrolled. Results: Of 77 patients, 55 (71.4%) showed increased F-18 FDG uptake in the myocardium. In this population, 40 showed uniform uptake pattern, while 15 showed focal uptake. In patients with uniform uptake, 17 showed decreased uptake in the septum without perfusion defect on myocardial SPECT. Remaining 23 patients showed uniform uptake, with 1 reversible perfusion defect and 1 fixed perfusion defect. In 15 patients with focal uptake, 9 showed increased F-18 FDG uptake in the base, and only 1 of them showed reversible perfusion defect on myocardial SPECT. In the remaining 6 focal uptake group, 4 had reversible perfusion defect in the corresponding wall, and 1 had apical hypertrophy. Conclusion: We demonstrated that septal defect pattern and basal uptake pattern in the myocardium may represent normal variants. Focal myocardial uptake other than normal variants on oncologic torso F-18 FDG PET/CT with routine fasting protocol may suggest ischemic heart disease, thus further evaluation is warranted.

The Evaluation of Reconstructed Images in 3D OSEM According to Iteration and Subset Number (3D OSEM 재구성 법에서 반복연산(Iteration) 횟수와 부분집합(Subset) 개수 변경에 따른 영상의 질 평가)

  • Kim, Dong-Seok;Kim, Seong-Hwan;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.17-24
    • /
    • 2011
  • Purpose: Presently in the nuclear medicine field, the high-speed image reconstruction algorithm like the OSEM algorithm is widely used as the alternative of the filtered back projection method due to the rapid development and application of the digital computer. There is no to relate and if it applies the optimal parameter be clearly determined. In this research, the quality change of the Jaszczak phantom experiment and brain SPECT patient data according to the iteration times and subset number change try to be been put through and analyzed in 3D OSEM reconstruction method of applying 3D beam modeling. Materials and Methods: Patient data from August, 2010 studied and analyzed against 5 patients implementing the brain SPECT until september, 2010 in the nuclear medicine department of ASAN medical center. The phantom image used the mixed Jaszczak phantom equally and obtained the water and 99mTc (500 MBq) in the dual head gamma camera Symbia T2 of Siemens. When reconstructing each image altogether with patient data and phantom data, we changed iteration number as 1, 4, 8, 12, 24 and 30 times and subset number as 2, 4, 8, 16 and 32 times. We reconstructed in reconstructed each image, the variation coefficient for guessing about noise of images and image contrast, FWHM were produced and compared. Results: In patients and phantom experiment data, a contrast and spatial resolution of an image showed the tendency to increase linearly altogether according to the increment of the iteration times and subset number but the variation coefficient did not show the tendency to be improved according to the increase of two parameters. In the comparison according to the scan time, the image contrast and FWHM showed altogether the result of being linearly improved according to the iteration times and subset number increase in projection per 10, 20 and 30 second image but the variation coefficient did not show the tendency to be improved. Conclusion: The linear relationship of the image contrast improved in 3D OSEM reconstruction method image of applying 3D beam modeling through this experiment like the existing 1D and 2D OSEM reconfiguration method according to the iteration times and subset number increase could be confirmed. However, this is simple phantom experiment and the result of obtaining by the some patients limited range and the various variables can be existed. So for generalizing this based on this results of this experiment, there is the excessiveness and the evaluation about 3D OSEM reconfiguration method should be additionally made through experiments after this.

  • PDF