• Title/Summary/Keyword: ${\mu}-CT$

Search Result 259, Processing Time 0.022 seconds

Change of Image Quality within Compression of AAPM CT Performance Phantom Image Using JPEG2000 in PACS (PACS에서 JPEG2000을 이용한 AAPM CT Performance Phantom영상의 압축에 따른 화질변화)

  • Kwon, Soon-Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.217-226
    • /
    • 2012
  • This study examines image quality of medical image after compression using JPEG2000 for AAPM CT Performance Phantom in PACS. The compressed images of 15:1 showed change of 1.93% and 0.81% in the CT number of water and the slice thickness, respectively, compared to the original images. The variation of the uniformity did not give a correlation for each measured area. In noise measurements at compressions of 10:1 and 15:1, changes of 1.47% to 10.99% were observed, respectively. The noise showed incremation tendency as increasing over the compression ratio 15:1, and the noise of 81.68% was measured at a compression of 40:1. CT number, uniformity, slice thickness, spatial resolution and contrast resolution for the compressed images were slightly changed by increasing the compression ratio. However, the noise was seriously changed relatively at the compressed images. Thus the noise was a important factor to determine the compression ration. A compression ratio of 10:1 for the AAPM CT Performance Phantom image was appropriate and could be applied to diagnostic images.

A Flow Cytometrical Analysis of the Antitumor and Immunostimulatory Effects of LCT-CT, a Cold-water Extract Prepared from Rice Grasshopper Oxya japonica japonica Thunberg (벼메뚜기(Oxya japonica japonica Thunberg) 물 추출물 LCT-CT의 항암면역 활성에 관한 유세포 분석학적 연구)

  • Chung, Kyeong-Soo;Kim, Bit Na
    • YAKHAK HOEJI
    • /
    • v.58 no.3
    • /
    • pp.151-157
    • /
    • 2014
  • Water extracts of rice grasshopper (Oxya japonica japonica Thurnberg) were prepared and their antitumor and immunostimulatory activities were investigated using a flow cytometer. When LCT-CT was ip injected into ICR mice at the dose of 33.3 mg/kg before and after the implantation of $4{\times}10^5$ cells/mouse of sarcoma 180 tumor cells, it inhibited the growth of the tumor cells by 96.6%, showed lymphoblstogenic activities on the splenic lymphocytes and increased the expression of CD25 molecules on the splenic T lymphocytes. When co-cultured with the splenic lymphocytes of a BALB/c mouse, LCT-CT showed strong immunostimulatory activities at the concentration of $25{\sim}100{\mu}g/ml$ by significantly increasing lymphoblasts ratio and CD25 expression.

Microvascular Contrast Image in Portal Veins of Rat using Micro-CT (마이크로 CT를 이용한 BALB/C(흰쥐) 간문맥의 미세혈관 조영 영상)

  • Lee, Sang-Ho;Lim, Cheong-Hwan;Jung, Hong-Rayng;Han, Beom-Hee;Mo, Eun-Hee;Chai, Kyu-Yun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.259-266
    • /
    • 2010
  • The study focuses on the value of Micro CT, a high resolution X-ray imaging device, by using it on rats to observe the overall portal vein image of the liver and the microvasculature of each lobes, visualize the 4 segmental lobes and acquire 3D image of the microvasculature through the reconstruction of sectional image data. Less of the damage to liver of the 5 mice, the device was able to separate the liver into 4 segmental lobes and displayed the 4 portal vein microvasculature in 2D. By using the 3D MIP technique, observation of the whole portal vein system microvasculature in 3D image was made possible along with each of the portal vein segment's branches until the 6th branch. Measured the size of 6branch, the average was measured at 1branch : $0.51mm{\pm}0.08$, 2 branch : $0.32mm{\pm}0.12$, 3 branch : $0.23mm{\pm}0.11$, 4 branch : $0.19mm{\pm}0.08$, 5 branch : $0.13mm{\pm}0.06$, 6 branch : $70.5{\mu}m{\pm}14.1$. The 3D image and the images of the microvasculatures in the result of study proved that the Micro-CT can be considered many useful device in obtaining high resolution images.

Comparison of the Equivalent Dose of the Lens Part and the Effective Dose of the Chest in the PET/CT Radiation Workers in the Nuclear Medicine Department (핵의학과 PET/CT실 방사선작업종사자의 수정체 부위의 등가선량과 흉부의 유효선량의 측정 비교)

  • Son, Sang-Joon;Park, Jeong-Kyu;Jung, Dong-Kyung;Park, Myeong-Hwan
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.209-215
    • /
    • 2019
  • Comparison of the effective dose of the chest and the equivalent dose of the lens site in the radiation workers working at four medical institutions with the PET / CT room located in one metropolitan city and province from April 1 to June 30, 2018 Respectively. Radioactive medicine were measured at the time of dispensing and at the time of injection. In this experiment, the average dispensing time per patient was 5.7 minutes and the average injection time was 3.1 minutes. The equivalent dose at the lens site was $0.78{\mu}Sv/h$ for 1 mCi, and the effective dose for chest was $0.18{\mu}Sv/h$ per 1 mCi. The equivalent dose at the lens site during injection was $0.88{\mu}Sv/h$ per mCi and the effective dose of chest was $0.20{\mu}Sv/h$ per mCi. The daily effective dose of the chest was $0.9{\pm}0.6{\mu}Sv$ and the equivalent dose of the lens site was $3.6{\pm}1.4{\mu}Sv$ during daily dosing for 20 days. The effective dose of the chest during the day was $0.6{\pm}0.5{\mu}Sv$ and the equivalent dose of the lens was $2.2{\pm}1.0{\mu}Sv$. At the time of dispensing, the equivalent dose of the lens was $0.187{\pm}0.035mSv$, the effective dose of the chest was $0.137{\pm}0.055mSv$, the equivalent dose of the lens was $0.247{\pm}0.057mSv$, and the effective dose of the monthly chest was $0.187{\pm}0.021mSv$. As a result of the corresponding sample test, the equivalent dose and the effective dose of the chest, the effective dose of the chest, the effective dose of the chest, the effective dose of the chest, The equivalent dose of the lens and the effective dose of the chest were statistically significant (p<0.05) with a significance of 0.000. However, there was no statistically significant difference (p>0.05) between the equivalent dose and the effective dose of the chest, the equivalent dose of the lens at the time of injection, and the effective dose of the chest at 0.138 and 0.230, respectively.

Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning (3차원 안모분석을 위한 저선량 Multi-detector CT 영상의 유효선량 및 화질 평가)

  • Chung, Gi-Chung;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.15-23
    • /
    • 2010
  • Purpose : This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. Materials and Methods : 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Results : Effective doses in ${\mu}Sv$ ($E_{2007}$) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. Conclusion : From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

3D Fusion Imaging based on Spectral Computed Tomography Using K-edge Images (K-각 영상을 이용한 스펙트럼 전산화단층촬영 기반 3차원 융합진단영상화에 관한 연구)

  • Kim, Burnyoung;Lee, Seungwan;Yim, Dobin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.523-530
    • /
    • 2019
  • The purpose of this study was to obtain the K-edge images using a spectral CT system based on a photon-counting detector and implement the 3D fusion imaging using the conventional and spectral CT images. Also, we evaluated the clinical feasibility of the 3D fusion images though the quantitative analysis of image quality. A spectral CT system based on a CdTe photon-counting detector was used to obtain K-edge images. A pork phantom was manufactured with the six tubes including diluted iodine and gadolinium solutions. The K-edge images were obtained by the low-energy thresholds of 35 and 52 keV for iodine and gadolinium imaging with the X-ray spectrum, which was generated at a tube voltage of 100 kVp with a tube current of $500{\mu}A$. We implemented 3D fusion imaging by combining the iodine and gadolinium K-edge images with the conventional CT images. The results showed that the CNRs of the 3D fusion images were 6.76-14.9 times higher than those of the conventional CT images. Also, the 3D fusion images was able to provide the maps of target materials. Therefore, the technique proposed in this study can improve the quality of CT images and the diagnostic efficiency through the additional information of target materials.

A Compensated Current Acqaisition Device for CT Saturation (왜곡 전류 보상형 전류 취득 장치)

  • Ryu, Ki-Chan;Gang, Soo-Young;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.96-98
    • /
    • 2005
  • In this paper, an algorithm to compensate the distorted signals due to Current Transformer(CT) saturation is suggested, First, DWT which can be easily realized by filter banks in real-time applications is used to detect a start point and an end point of the saturation. Secondly, For enough Datas those need to use the least-square curve fitting method, the distorted current signal is compensated by the AR(autoregressive) model using the data during the previous healthy section until pick point of Saturation. Thirdly, the least-square curve fitting method is used to restore the distorted section of the secondary current. Finaly, this algorithm had a Hadware test using DSP board(TMS320C32) with Doble test device. DWT has superior detection accuracy and the proposed compensation algorithm which shows very stable features under various levels of remanent flux in the CT core is also satisfactory. And this algorithm is more correct than a previous algorithm which is only using the LSQ fitting method. Also it can be used as a MU involving the compensation function that acquires the second data from CT and PT.

  • PDF

Evaluation of auto contouring accuracy in 3D planning system (3차원 입체조형치료시 Auto Contouring tool의 유용성 평가)

  • Choi, JM;Ju, SG;Park, JY;Park, YH;Kim, JS
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.35-39
    • /
    • 2002
  • Introduction : It is essential to input patients external contour in 3D treatment plan. We would like to see changes in depth and dose when 3D RTP is operating auto contouring when windows value (Width/Level) differs in this process. Material & Methode : We have analyzed the results with 3D RTP after CT Scanning with round CT Phantom. We have compared and analyzed MU values according to depth changes to Isocenter changing external contour and inputting random Window value. We have watched change values according to dose optimization in 4 directions(LAO, LPO, RAO, RPO), We plan 100 case for exact analyzation. We have results changing window value random to each beam in 100 cans. Result : It showed change between minimum and maximum value in 4 beam is Depth 0.26mm, MU $1.2\%$ in LAO. It showed LPO-Depth 0.13mm, MU $0.9\%$, RAO-Depth 0.2mm MU $0.8\%$, RPO-Depth 0.27mm, MU $1.1\%$ Conclusion : Maximum change in depth 0.27 mm, MU error rate is $0.12\%$ according to Window change. As we can see in these results, it seems Window value change doesn't effect in treatment. However, it seems there needs to select appropriate Window value in precise treatment.

  • PDF

Characteristics of Hg, Pb, As, Se Emitted from Medium Size Waste Incinerators (중형폐기물 소각시설의 수은, 납, 비소, 셀렌 배출특성)

  • Lee Han-Kook
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.8-18
    • /
    • 2006
  • The aim of this study is to evaluate the emission characteristics of mercury, lead, arsenic, and selenium from medium size municipal solid waste incinerators(MSWIs) in Korea. The concentrations of mercury, lead, arsenic, and selenium emitted from medium size MSWI stack were $2.67\;{\mu}g/Sm^3,\;0.38\;mg/Sm^3,\;1.33\;{\mu}g/Sm^3,\;0.28\;{\mu}g/Sm^3$, respectively. The concentration levels of mercury, lead, arsenic in flue gas from medium size MSW incinerator stacks selected were nearly detected under the Korea criteria level. Removal efficiencies of mercury, lead, arsenic, and selenium in waste heat boiler(WHE) and cooling tower(CT) were $90.36\%,\;69.76\%,\;43.04\%,\;40.64\%$, respectively. In general, the removal efficiencies of mercury and lead in WHE were higher than those of arsenic and selenium in WHE. Emission gas temperature reduction from waste heat boiler(WHB) and cooling tower(CT) can control mercury and lead of medium size MSWIs. To evaluate the relationship between mercury, lead, arsenic, selenium of fly ash and those of flue gas, it was carried out to correlation analysis of each metal concentration in the fly ash and in the flue gas from medium size MSWIs. From the correlation analysis, the coefficients of mercury, lead, arsenic, and selenium were 0.61, -0.38, 0.87, 0.28, respectively. The results of correlation analysis revealed that it should be highly positive to the correlation coefficients of mercury and arsenic in the fly ash and those of the flue gas emitted from medium size MSWIs. As it were, the concentrations of mercury and arsenic of flue gas from medium size MSWIs are high unless mercury and arsenic in fly ash are properly controlled in dust collection step in medium size MSWIs. It was also concluded that mercury, lead, arsenic, and selenium from MSWIs stacks could be controlled by waste heat boiler(WHE) and dust collecting step in medium size MSWIs.

Evaluation of Hormone Deficiency in Vertebral Body: Analysis of Bone Structure and Quality (호르몬 결핍이 척추체에 미치는 영향 평가: 골의 구조학적 및 질적 요소 분석)

  • Kim, Chi-Hoon;Woo, Dae-Gon;Park, Ji-Hyung;Lee, Beob-Yi;Kim, Chi-Hyun;Kim, Han-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.5
    • /
    • pp.92-101
    • /
    • 2010
  • This study evaluated the structure and quality of osteoporotic vertebral bone. To induce osteoporosis, eight rats were ovariectomized (OVX). All rats were divided into two groups (Normal group: 4, OVX group: 4). Total lumbar vertebrae for each rat were scanned by in-vivo ${\mu}CT$ at 0, 4 and 8 weeks. Morphological characteristics (BV/TV, Tb.Th, Tb.N, Tb.Sp and SMI) were calculated by in-vivo ${\mu}CT$ image analyzer. Three dimensional finite element models were analyzed to investigate bone strength of OVX and Normal groups. Moreover, the elastic modulus was quantitatively analyzed to evaluate the quality changes of osteoporotic bone. In the OVX group, BV/TV, Tb.Th and Tb.N were significantly decreased at all the lumbar over time (p<0.05). We also investigated a contrary tendency in Tb.Sp and SMI, compared to the above results in each group. A degree of alteration of mechanical characteristics in OVX group was decreased over measuring time (p<0.05). Bone quality presented by distribution of elastic modulus was improved in the Normal group more than OVX group. The findings of the present study indicated that both bone structure and quality of whole lumbar could be tracked and detected by analyzing the morphological and biomechanical characteristics of bones, based on a nondestructive method.