• Title/Summary/Keyword: ${\mu}$-approach

Search Result 453, Processing Time 0.024 seconds

A Study on Laser Induced Fluorescence and Coagulation in Particle Transport Mode (입자 이동 방식에서 Laser Induced Fluorescence와 뭉침에 관한 연구)

  • Kim, Ki-Jun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.340-346
    • /
    • 2006
  • The influences of fluorescence, scattering, and flocculation in turbid material by light scattering were interpreted for the scattered fluorescence intensity and wavelength, it has been studied the molecular properties by the spectroscopy of laser induced fluorescence (LIF). The effects of optical properties in scattering media have been found by the optical $parameters({\mu}_s,\;{\mu}_a,\;{\mu}_t)$. Flocculation is an important step in many solid-liquid separation processes and is widely used. When two particles approach each other, interactions of several colloid particles can come into play which may have major effect on the flocculation and LIF process, The value of scattering coefficient ${\mu}_s$ is large by means of the increasing particles of scatterer it has been found that the slope decays exponentially as a function of distance from laser source to detector. It may also aid in designing the best model for oil chemistry, biopharmaceutical products, laser medicine and application of medical engineering on LIF and coagulation in particle transport mode.

Simultaneous Measurement of Strain and Temperature by use of Fiber Bragg Grating Written in an Erbium: Ytterbium-Doped Fiber (단일 광섬유 격자와 Erbium과 Ytterbium 첨가된 광섬유를 이용한 스트레인 및 온도의 동시 측정)

  • Jung, Jae-Hoon
    • Journal of IKEEE
    • /
    • v.8 no.1 s.14
    • /
    • pp.117-120
    • /
    • 2004
  • We demonstrate a fiber-optic sensor scheme, capable of the simultaneous measurement of strain and temperature using a single fiber Bragg grating written in an erbium: ytterbium-doped fiber. This novel and compact fiber grating based sensor scheme can be used for synchronous measurement of strain and temperature over ranges of $1100\;{\mu}{\varepsilon}$ and $50-180\;^{\circ}C$ with rms errors of $55.8\;{\mu}{\varepsilon}$ and $3^{\circ}C$, respectively. The simple and low-cost sensor approach has a considerable potential, particularly for wide-range strain sensing applications in which high resolution is not required.

  • PDF

PIV measurement of oscillatory flow in a micro-channel as a bronchiole model

  • LEE Won-je;KAWAHASHI Massaki;HIRAHARA Hiroyuki
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.125-134
    • /
    • 2004
  • The improvement of artificial respiration method has brought about the decrease in mortality of pulmonary diseases patients. Various respiratory curative methods, inclusive of HFOV (High Frequency Oscillatory Ventilation), have been developed for more effectual and less harmful management of acute respiratory failure. However, the mechanism of gas transfer and diffusion in a bronchiole has not yet been clarified in detail. As a first approach to the problem, we measured oscillatory flows in a Y-shaped micro-channels as bronchiole model by micro Particle Image Velocimetry(micro PIV). In order to establish the fundamental technique of PIV measurements on oscillatory air flow in a micro-channel, we used about 500-nm-diameter incense smoke particles, a diode laser, a high speed camera including an objective lens, and a HFOV, which is effective technique for medical care of pulmonary disease patients, especially, infants. The bronchiole model size is that parent tube is $500\{mu}m$ width and $500\{mu}m$ depth, and daughter tubes are $450\{mu}m$ width and $500\{mu}m$ depth. From this study made on the phenomenon of fluid in micro size bronchus branch of a lung, we succeeded to get time series velocity distribution in a micro scale bronchial mode. The experimental results of velocity distribution changing with time obtained by micro PIV can give fundamental knowledge on oscillatory airflow in micro-channel.

  • PDF

Real-coded Micro-Genetic Algorithm for Nonlinear Constrained Engineering Designs

  • Kim Yunyoung;Kim Byeong-Il;Shin Sung-Chul
    • Journal of Ship and Ocean Technology
    • /
    • v.9 no.4
    • /
    • pp.35-46
    • /
    • 2005
  • The performance of optimisation methods, based on penalty functions, is highly problem- dependent and many methods require additional tuning of some variables. This additional tuning is the influences of penalty coefficient, which depend strongly on the degree of constraint violation. Moreover, Binary-coded Genetic Algorithm (BGA) meets certain difficulties when dealing with continuous and/or discrete search spaces with large dimensions. With the above reasons, Real-coded Micro-Genetic Algorithm (R$\mu$GA) is proposed to find the global optimum of continuous and/or discrete nonlinear constrained engineering problems without handling any of penalty functions. R$\mu$GA can help in avoiding the premature convergence and search for global solution-spaces, because of its wide spread applicability, global perspective and inherent parallelism. The proposed R$\mu$GA approach has been demonstrated by solving three different engineering design problems. From the simulation results, it has been concluded that R$\mu$GA is an effective global optimisation tool for solving continuous and/or discrete nonlinear constrained real­world optimisation problems.

Studies on the Wave Propagation and Fluctuation in Randomly Ditribution Media of L-Aspartic Acid (L-Aspartic Acid의 무질서하게 분포된 매질에서 파동전개와 변동에 관한 연구)

  • Kim, Ki-Jun;Lee, Joo-Youb
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.122-128
    • /
    • 2012
  • The influences of fluorescence, scattering, and flocculation in turbid material by light scattering of L-aspartic acid, preservative and emulsifier were interpreted for the scattered fluorescence intensity and wavelength. They have been studied the molecular properties by the spectroscopy of laser induced fluorescence (LIF) and flocculation. The effects of optical properties in scattering media have been found by the optical parameters(${\mu}_s$, ${\mu}_a$, ${\mu}_t$). Flocculation is an important step in many solid-liquid separation processes and is widely used. When two particles approach each other, interactions of several colloid particles can come into play which may have major effect on the flocculation and LIF process. The values of scattering coefficient ${\mu}_s$ are large by means of the increasing scattering of scatterer, The values have been found that the slope decays exponentially as a function of concentration from laser source to detector by our experimental result. It may also aid in designing the best model for oil chemistry, bio-pharmaceutical products, laser medicine and application of medical engineering on LIF and coagulation in particle transport mode.

Outcomes and Use of Therapeutic Drug Monitoring in Multidrug-Resistant Tuberculosis Patients Treated in Virginia, 2009-2014

  • Heysell, Scott K.;Moore, Jane L.;Peloquin, Charles A.;Ashkin, David;Houpt, Eric R.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.2
    • /
    • pp.78-84
    • /
    • 2015
  • Background: Reports of therapeutic drug monitoring (TDM) for second-line medications to treat multidrug-resistant tuberculosis (MDR-TB) remain limited. Methods: A retrospective cohort from the Virginia state tuberculosis (TB) registry, 2009-2014, was analyzed for TDM usage in MDR-TB. Drug concentrations, measured at time of estimated peak ($C_{max}$), were compared to expected ranges. Results: Of 10 patients with MDR-TB, 8 (80%) had TDM for at least one drug (maximum 6 drugs). Second-line drugs tested were cycloserine in seven patients (mean $C_{2hr}$, $16.6{\pm}10.2{\mu}g/mL$; 4 [57%] below expected range); moxifloxacin in five (mean $C_{2hr}$, $3.2{\pm}1.5{\mu}g/mL$; 1 [20%] below); capreomycin in five (mean $C_{2hr}$, $21.5{\pm}14.0{\mu}g/mL$; 3 [60%] below); para-aminosalicylic acid in five (mean $C_{6hr}$, $65.0{\pm}29.1{\mu}g/mL$; all within or above); linezolid in three (mean $C_{2hr}$, $11.4{\pm}4.1{\mu}g/mL$, 1 [33%] below); amikacin in two (mean $C_{2hr}$, $35.3{\pm}3.7{\mu}g/mL$; 1 [50%] below); ethionamide in one ($C_{2hr}$, $1.49{\mu}g/mL$, within expected). Two patients died: a 38-year-old woman with human immunodeficiency virus/acquired immune deficiency syndrome and TB meningitis without TDM, and a 76-year-old man with fluoroquinolone-resistant (pre-extensively drug-resistant) pulmonary TB and low linezolid and capreomycin concentrations. Conclusion: Individual pharmacokinetic variability was common. A more standardized approach to TDM for MDR-TB may limit over-testing and maximize therapeutic gain.

A novel approach in voltage transient technique for the measurement of electron mobility and mobility-lifetime product in CdZnTe detectors

  • Yucel, H.;Birgul, O.;Uyar, E.;Cubukcu, S.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.731-737
    • /
    • 2019
  • In this study, a new measurement method based on voltage transients in CdZnTe detectors response to low energy photon irradiations is applied to measure the electron mobility (${\mu}_e$) and electron mobility-lifetime product $({\mu}{\tau})_e$ in a CdZnTe detector. In the proposed method, the pulse rise times are derived from low energy photon response to 59.5 keV($^{241}Am$), 88 keV($^{109}Cd$) and 122 keV($^{57}Co$) ${\gamma}-rays$ for the irradiation of the cathode surface at each detector for different bias voltages. The electron $({\mu}{\tau})_e$ product was then determined by measuring the variation in the photopeak amplitude as a function of bias voltage at a given photon energy using a pulse-height analyzer. The $({\mu}{\tau})_e$ values were found to be $(9.6{\pm}1.4){\times}10^{-3}cm^2V^{-1}$ for $1000mm^3$, $(8.4{\pm}1.6){\times}10^{-3}cm^2V^{-1}$ for $1687.5mm^3$ and $(7.6{\pm}1.1){\times}10^{-3}cm^2V^{-1}$ for $2250mm^3$ CdZnTe detectors. Those results were then compared with the literature $({\mu}{\tau})_e$ values for CdZnTe detectors. The present results indicate that, the electron mobility ${\mu}_e$ and electron $({\mu}{\tau})_e$ values in CdZnTe detectors can be measured easily by applying voltage transients response to low energy photons, utilizing a fast signal acquisition and data reduction and evaluation.

An Alternative Approach to the Traditional Mixotrophic Cultures of Haematococcus pluvialis Flotow (Chlorophyceae)

  • Goksan, Tolga;Ak, lknur;Gokpinar, Sevket
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.9
    • /
    • pp.1276-1282
    • /
    • 2010
  • In traditional mixotrophic cultures of microalgae, all the inorganic nutrients and organic carbon sources are supplied in the medium before inoculation. In this study, however, an alternative approach was adopted in Haematococcus pluvialis Flotow, a microalga capable of growing mixotrophically on sodium acetate (Na-Ac). First, the cells were grown under 75 ${\mu}Mol$ photons $m^{-2}s^{-1}$ phototrophically without Na-Ac until the stationary phase and then exposed to five different light regimes by the addition of Na-Ac (e.g., dark, 20, 40, 75, and 150 ${\mu}Mol$ photons $m^{-2}s^{-1}$). Dry weight (DW), pigments, and especially cell number in alternative mixotrophy (AM) were higher than traditional mixotrophy (TM). Cell number in AM almost doubled up from 21.7 to $42.9{\times}10^4$ cells/ml during 5-day exposure to Na-Ac, whereas the increase was only 1.2-fold in TM. Maximum cell density was reached in 75 ${\mu}Mol$ photons $m^{-2}s^{-1}$ among the light intensities tested. We propose that Na-Ac in TM of H. pluvialis can not be utilized as efficiently as in AM. With this respect, AM has several advantages against TM such as a much higher cell density in a batch culture period and minimized risk of contamination owing to the shorter exposure of cells to organic carbon sources. In consequence, this method may be used for other strains of the species, and even for the other microalgal species able to grow mixotrophically.

Changes of Surface Electromyography on Frontalis Muscle during Electro-Acupuncture Stimulation of Abdomen or Legs - A Pilot Study for Clinical Approach to Autonomic Nervous System Changes - (복부 및 사지 부위의 전기침 자극이 전두근에서 측정한 SEMG 변화에 미치는 영향 - 자율신경계의 변화에 대한 임상적 접근을 위한 사전 연구 -)

  • Je, Jun-Tae;Choi, San-Ho;Shin, Sun-Ho;Lim, Jin-Young;Lee, Sang-Kwan
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.1
    • /
    • pp.14-25
    • /
    • 2012
  • Objectives : To observe physiological changes during clinical acupuncture treatment. Methods : We recruited 40 healthy volunteers who had experienced an acupuncture treatment at least once within the past three years. The experimental group was divided into four groups according to the needling site and frequency of electrical stimulation. Sites consisted of abdomen and legs. Frequencies consisted of 100 Hz and 2 Hz. The procedures of experimental treatment consisted of seven phases, Resting I phase (Resting I), Needle insertion phase (Insertion), Maintenance of needle insertion I phase (Maintain I), Electrical stimulation phase (ES), Maintenance of needle insertion II phase (Maintain II), Needle removal phase (Removal) and Resting II phase (Resting II). We measured the surface electromygraphy (SEMG) through an electrode on the frontalis muscle during all phases consecutively. Results : When SEMGs of all seven phases were analyzed, they significantly increased or decreased according to phases. SEMGs of Insertion, Maintain I, ES and Maintain II phase significantly increased more than RestingI in abdomen and legs groups. SEMGs of the abdomen group were measured as being $4.78{\pm}0.74{\mu}V$ on Resting I, $16.48{\pm}3.97{\mu}V$ on Insertion, $46.31{\pm}10.56{\mu}V$ on Maintain I, $45.88{\pm}9.72{\mu}V$ on ES, $45.56{\pm}9.69{\mu}V$ on Maintain II, $18.76{\pm}3.05{\mu}V$ on Removal, and $3.75{\pm}0.65{\mu}V$ on Resting II. SEMGs of the legs group were measured as being $3.34{\pm}0.35{\mu}V$ on Resting I, $12.11{\pm}1.76{\mu}V$ on Insertion, $36.74{\pm}6.99{\mu}V$ on Maintain I, $33.57{\pm}6.30{\mu}V$ on ES, $32.66{\pm}6.03{\mu}V$ on Maintain II, $14.08{\pm}2.15{\mu}V$ on Removal, and $2.88{\pm}0.32{\mu}V$ on Resting II. Conclusions : SEMG changed differently according to processes of acupuncture. Electrical stimulation showed different change of SEMG. Thus, acupuncture treatment may change the status of the autonomic nervous system.

Effects of Serotonin, Ecdysone and HCG on Ovarian Maturation of the Fleshy Prawn, Fenneropenaeus chinensis (대하(Fenneropenaeus chinensis)의 난소 성숙에 대한 Serotonin, Ecdysone 그리고 HCG의 효과)

  • Lee, Jae-Yong;Kim, Dae-Jung;Kim, Dae-Hyun;Kim, Myung-Hee;Kim, Byung-Ki;Lee, Bok-Kyu;Han, Chang-Hee
    • Development and Reproduction
    • /
    • v.13 no.4
    • /
    • pp.341-351
    • /
    • 2009
  • The effects of serotonin (5-hydroxytryptamine, 5-HT), ecdysone (20-hydroxyecdysone, 20-E) and HCG (human chorionic gonadotropin) on the ovarian maturation of the fleshy shrimp, Fenneropenaeus chinensis were investigated. Adult female fleshy shrimps were injected with 5-HT ($5{\mu}g$/g body weight (BW) or $20{\mu}g$/g BW), 20-E ($5{\mu}g$/g BW, $10{\mu}g$/g BW or $20{\mu}g$/g BW) or HCG (5 IU/g BW or 10 IU/g BW) three times at 5-day intervals and were sacrificed 10 days after the last injection. The effects were compared against an intact control group and sham control group which received the injection of sterile saline solution as a vehicle. 20-E and HCG showed no effectiveness on ovarian maturation in fleshy shrimps. However flesh shrimp given 5-HT of $20{\mu}g$/g BW showed significant increase in gonadosomatic index (GSI) in early spring. The results suggest that treatment of 5-HT of $20{\mu}g$/g BW or more is useful approach for the nursery production of the fleshy shrimp, Fenneropenaeus chinensis aquaculture.

  • PDF