• Title/Summary/Keyword: ${\gamma}$-set

Search Result 291, Processing Time 0.026 seconds

Usefulness of Flow Composite Image in Raynaud Scan ($^{201}Tl$) ($^{201}Tl$을 이용한 레이노 검사에서 동적 Composite 영상의 유용성)

  • Kim, Dae-Yeon;Shin, Gyoo-Seol;Oh, Eun-Jung;Kim, Gun-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.101-104
    • /
    • 2010
  • Purpose: Raynaud scan is divided to flow, blood pool and local-delay image. Usually, we evaluate comparison through blood pool and local-delay image. We will evaluate about usability when comparative observe blood image and local-delay image in Raynaud scan that used $^{201}Tl$ as making flow image to one sheet of images. Materials and Methods: We have selected 29 Raynaud phenomenon patients aged 14~68 years who visited department of vascular surgery between Feb. 2008 and Aug. 2009. An intravenous injection $^{201}Tl$ of 111 MBq (3 mCi) to opposite side diagonal line limbs above an internal auditing department. Equipment used Philips gamma camera forte A-Z, and collimator used LEHR. Matrix size set up to each $64{\times}64$, $128{\times}128$, $256{\times}256$ and zoom factor used to full field. Protocol of dynamic is 2 second to 155 frames. Blood pool and delay count to 300 second. We set up ROI by a foundation to data acquired in PEGASYS processing program. Each results were analyzed with the SPSS 12.0 statistical software. Results: Each averages of count ratio (Rt / Lt) to have been given at composite image, a blood pool image, delay images analyzed at Raynaud phenomenon patients is $1.25{\pm}0.39$, $1.20{\pm}0.33$, $1.11{\pm}0.17$. The sample analysis results of blood pool image and delay image contented itself with p<0.029. Also, there don't have been each difference, and blood pool image, delay image regarding composite image was able to know. Conclusion: We were able to give help for comparison to evaluate a blood pool image and a local delay image at the Raynaud scan which used $^{201}Tl$ while making a flow image to one sheet image. Identification to be visual too was possible. If you are proceeded a researcher that there was further depth, you are more appropriate for, and you may get useful information.

  • PDF

Comparison of Activity Capacity Change and GFR Value Change According to Matrix Size during 99mTc-DTPA Renal Dynamic Scan (99mTc-DTPA 신장 동적 검사(Renal Dynamic Scan) 시 동위원소 용량 변화와 Matrix Size 변경에 따른 사구체 여과율(Glomerular Filtration Rate, GFR) 수치 변화 비교)

  • Kim, Hyeon;Do, Yong-Ho;Kim, Jae-Il;Choi, Hyeon-Jun;Woo, Jae-Ryong;Bak, Chan-Rok;Ha, Tae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • Purpose Glomerular Filtration Rate(GFR) is an important indicator for evaluating renal function and monitoring the progress of renal disease. Currently, the method of measuring GFR in clinical trials by using serum creatinine value and 99mTc-DTPA(diethylenetriamine pentaacetic acid) renal dynamic scan is still useful. After the Gates method of formula was announced, when 99mTc-DTPA Renal dynamic scan is taken, it is applied the GFR is measured using a gamma camera. The purpose of this paper is to measure the GFR by applying the Gates method of formula. It is according to effect activity and matrix size that is related in the GFR. Materials and Methods Data from 5 adult patients (patient age = 62 ± 5, 3 males, 2 females) who had been examined 99mTc-DTPA Renal dynamic scan were analyzed. A dynamic image was obtained for 21 minutes after instantaneous injection of 99mTc-DTPA 15 mCi into the patient's vein. To evaluate the glomerular filtration rate according to changes in activity and matrix size, total counts were measured after setting regions of interest in both kidneys and tissues in 2-3 minutes. The distance from detector to the table was maintained at 30cm, and the capacity of the pre-syringe (PR) was set to 15, 20, 25, 30 mCi, and each the capacity of post-syringe (PO) was 1, 5, 10, 15 mCi is set to evaluate the activity change. And then, each matrix size was changed to 32 × 32, 64 × 64, 128 × 128, 256 × 256, 512 × 512, and 1024 × 1024 to compare and to evaluate the values. Results As the activity increased in matrix size, the difference in GFR gradually decreased from 52.95% at the maximum to 16.67% at the minimum. The GFR value according to the change of matrix size was similar to 2.4%, 0.2%, 0.2% of difference when changing from 128 to 256, 256 to 512, and 512 to 1024, but 54.3% of difference when changing from 32 to 64 and 39.43% of difference when changing from 64 to 128. Finally, based on the presently used protocol, 256 × 256, PR 15 mCi and PO 1 mCi, the GFR value was the largest difference with 82% in PR 15 mCi and PO 1 mCi. conditions, and at the least difference is 0.2% in the conditions of PR 30 mCi and PO 15 mCi. Conclusion Through this paper, it was confirmed that when measuring the GFR using the gate method in the 99mTc-DTPA renal dynamic scan. The GFR was affected by activity and matrix size changes. Therefore, it is considered that when taking the 99mTc-DTPA renal dynamic scan, is should be careful by applying appropriate parameters when calculating GFR in the every hospital.

Study on Radioactive Material Management Plan and Environmental Analysis of Water (I) Study of Radioactive Substances in Water Management and Analysis to Eat of the US Environmental Protection Agency (Envirionmental Protection Agency) (물 환경의 방사성 물질 관리 방안과 분석법에 관한 연구 (I) 미국환경보호청(Envirionmental Protection Agency)의 먹는 물 방사성물질 관리와 분석법에 관한 고찰)

  • Her, Jae;Kim, Jung-Min;Min, Hye-Lim;Han, Seong-Gyu;Lim, Hyun-Jong;Jo, Han-Byeol;Noh, Young-Hoon;Lee, Ho-Sun;Park, Min-Suk
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.163-170
    • /
    • 2015
  • The interest of the people in the radioactive contamination of the water has increased significantly and the study about analysis and management of radioactive materials are being actively conducted. And monitoring spots have been expanded to the range of public water as well as drinking water by publishing the rule of drinking water quality standards and examination in the Environmental Enforcement Ordinance No. 553 of Korea. In this study, US EPA was investigated as the foreign advanced cases and the way that is appropriate for the Korea was sought by analyzing investigate radionuclide, interval and management. As a result, in the selection part of investigate radionuclide, geological survey, status of nuclear power plants and the presence of the use of artificial radionuclides of the Korea should be investigated and additionally after the selection of a few radionuclides, the systems should be extended to cover all possible radionuclides by considering radioactive pollution levels in humans may be exposed due to the annual drinking water. In the part of the investigate interval, the concept(MCL, DL) should be set up for preventing concentration detection of above MCL and it needs to the maintenance and management. For example, when the concentration is more than MCL, it should be investigated on a quarterly and when the concentration is lower than MCL, it should be investigated to each different interval and management. And the US EPA divided the management area and make the roadmap for managing drinking water. The each classified area has been organized to match the state budget and labor force and the individual data have been managed effectively by HPGe, the NaI, TLD and so on.

Preliminary Investigations of the Dosimetric Properties of a Normoxic Polymethacrylic Acid Gel Dosimeter Using a Respiration-Motion Simulator (호흡모의움직임장치를 이용한 정상산소 폴리메타크릴산 겔 선량계의 선량특성)

  • Park, Chae Hee;Cho, Yu Ra;Cho, Kwang Hwan;Park, Ji Ae;Kim, Kyeong Min;Kim, Kum Bae;Jung, Hai Jo;Ji, Young Hoon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.138-144
    • /
    • 2012
  • Dose distribution throughout the clinical organ range of motion was analyzed using a respiratory-motion simulator that was equipped with a polymer gel dosimeter and EBT2 film. The normoxic polymer gel dosimeter was synthesized from gelatin, MAA, HQ, THPC and HPLC. The gel dosimeter and EBT2 film were irradiated with Co-60 gamma rays that were moved along the x-axis and y-axis in ${\pm}1.5cm$ steps at five-second intervals. The field size was $5{\times}5cm^2$. The SSD was 80 cm and set to 10 Gy at a depth of 2 cm. The PDD at a depth of 50 mm was 75.2% in the ion chamber, 82.3% in the static state and 86.1% in the dynamic state in the gel dosimeter. The penumbra for the dynamic state target, which was measured using the gel dosimeter, averaged 10.89 mm, this is a 40.5% increase over the penumbra of the static state target of 7.74 mm. In addition, when measuring with gel dosimetry, the value for the penumbra is 36.6% smaller in the static state and 29.4% smaller in the dynamic state compared to measuring with film. The aim of this study was to investigate the dosimetric properties of a normoxic polymethacrylic acid gel dosimeter in static and dynamic states and to evaluate the potentiality as a relative dosimeter for dynamic therapeutic radiation.

Production of Nitric Oxide in Raw 264.7 Macrophages treated with Ganoderan, the ${\beta}-Glucan$ of Ganoderma lucidum (영지의 균사체성 ${\beta}-glucan$에 의한 Raw 264.7 대식세포의 Nitric Oxide생성)

  • Han, Man-Deuk;Lee, Eun-Sook;Kim, Young-Kweon;Lee, June-Woo;Jeong, Hoon;Yoon, Kyung-Ha
    • The Korean Journal of Mycology
    • /
    • v.26 no.2 s.85
    • /
    • pp.246-255
    • /
    • 1998
  • Ganoderan (GAN), an immunomodulating ${\beta}-glucan$ of G. lucidum, induces potent antitumor immunity in tumor-bearing mice. This study was set up to elucidate the ability of macrophage activation of GANs. GAN-treated Raw 264.7 macrophages showed enhanced production of nitric oxide (NO). The ability of GANs to produce NO was based on differences in chemical composition of GANs obtained from the mycelium on various carbon sources and mycelial fractionation. The highest NO production was observed in CW-AS-WS polysaccharide which was extracted from the mycelial wall. GAN-treated Raw 264.7 cells gave a 2-to 5-fold (24 hr) formation of NO levels compared with those treated with medium only. Partial removal of the protein in the extracellular GAN by TCA treatment did appreciably reduce its capacity to secrete NO. The mixture effect of GAN and LPS increased the nitric oxide secretion from RAW 264.7. The cell proliferation of GAN-treated Raw 264.7 cell tines inhibited as compared with its control. Of the culture supernatant of macrophage activated by GAN, the percentage of cytotoxicity against mouse leukemia L1210 cells was slightly dependent on the amount of NO in the culture supernatants of the activated-macrophages. These results indicate that the ${\beta}-glucan-related$ polysaccharides of the higher fungus activate macrophage and release nitric oxide. It also suggests that murine macrophages possess certain receptors for ${\beta}-anomeric$ glucans and play a critical role of ${\beta}-glucan-related$ tumor killing mechanism.

  • PDF

Effect of GB 34-GB 39 Electro-acupuncture on Regional Cerebral Blood Flow in Stroke Patients and Normal Volunteers Evaluated by $^{99m}Tc-ECD$ SPECT (양릉천-현종 전침치료가 뇌경색환자 및 정상인의 뇌혈류에 미치는 영향 - SPECT와 SPM을 이용한 연구 -)

  • Han, Jin-An;Jeong, Dong-Won;Bae, Hyung-Sup;Park, Sung-Uk;Jung, Woo-Sang;Park, Jung-Mee;Ko, Chang-Nam;Cho, Ki-Ho;Kim, Young-Suk;Kim, Deok-Yoon;Moon, Sang-Kwan
    • The Journal of Korean Medicine
    • /
    • v.27 no.3 s.67
    • /
    • pp.187-200
    • /
    • 2006
  • Objectives: Acupuncture has been applied in Asia for thousands of years, especially to rehabilitation after stroke. It has been reported that acupuncture increased cerebral blood supply and stimulated the functional activity of brain nerve cells shown by using brain imaging techniques. This study was to evaluate the effect of GB 34-GB 39 electro-acupuncture (EA) on regional cerebral blood flow (rCBF) in stroke patients and normal volunteers using single photon emission computed tomography (SPECT). Methods: The study procedure was divided into two parts: patients and volunteers studies. For the patients study, ten ischemic stroke patients (3 males, 7 females, mean age $68.5{\pm}8.9$ years old) were selected. Baseline brain SPECT was done with triple head gamma camera (MultiSPECT3, Siemens, USA) after intravenous administration of 1,110 MBq of $^{99m}Tc-ECD$. Fifteen-minute EA at GB 34 and GB 39 were applied on the affected limb. The same dose of $^{99m}Tc-ECD$ was injected during the EA, and the second set of SPECT images wasobtained. Using the computer software (ICON 7.1, Siemens, USA), 3 SPECT slices (upper, middle, lower) surrounding the brain lesion were selected and each slice was divided into 10-16 brain regions. Asymmetry indexes (AI) were analyzed in each brain region. We regarded over 10% changes of AI between before and after EA as significance. For the volunteers study, 10 healthy human volunteers (5 males, 5 females, mean age $28.1{\pm}6$ years old) were selected. In the resting state, $^{99m}Tc-ECD$ brain SPECT scans were performed. On the 7th day after the resting examination, 15 minute EA was applied at GB 34 and GB 39 on the right side of the subjects. Immediately after EA, the second SPECT images were obtained inthe same manner as the resting state. Significant increases and decreases of rCBF after EA were estimated by comparing their SPECT images with those of the resting state using paired t statistics at every voxel, which were analyzed by statistical parametric mapping with a threshold of p = 0.01, uncorrected (extent threshold: k=100 voxels). Results: In stroke patients, six of the eight (75%) had significantly increased perfusion in post-acupuncture scans compared to their baseline state. In normal volunteers, GB 34-GB GB EA increased rCBF in both hemispheres including right ventral posterior cingulate (Brodmann area (BA) 23), left superior temporal, anterior transverse temporal (BA 22, 41), left parastriate, peristriate (BA 18, 19), right occipitotemporal, angular (BA 37, 39), left rostral postcentral, caudal postcentral and preparietal (BA 2, 3, 5). However GB 34-GB 39 EA decreased rCBF in the right hemisphere including triangular and middle frontal lobes. Conclusions: The results demonstrated that OB 34-GB 39 EA increased cerebral perfusion in ischemic stroke patients and increased rCBF grossly in temporal lobes of normal volunteers. It is also suggested that there may be a correlation between the GB meridian and the territory of the middle cerebral artery.

  • PDF

Establishment of Reference Intervals of Osteocalcin according to Age in Women for Health Promotion Center (건강검진이 의뢰된 여성의 연령에 따른 Osteocalcin의 참고범위 설정)

  • Kang, Ji-Soon;Yoo, Byoung-Joo;Oh, Jung-Eun;Kim, Geon-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.104-111
    • /
    • 2009
  • Purpose: Osteocalcin is also known as the bone gamma-carboxyglutamic acid (Gla) protein (BGP), is noncollagenous bone protein synthesized by osteoblasts. Serum concentrations of Osteocalcin have been used as a biochemical marker of bone turnover. The reference intervals of Osteocalcin is categorized by kit corporation according to the age. However, each laboratory should establish its own reference intervals. In this study, the variation in the serum Osteocalcin level were used to find actual standard age-specific Osteocalcin reference intervals. Materials and Methods: We have selected 864 healthy females aged 20~80 years who visited a health promotion center between Aug. 2007 and Sep. 2008. The Osteocalcin IRMA Kit (OSTEO-RIACT, CIS Bio international, Gif-sur-Yvette, France) was used for the quantification. Each results were analyzed with the SPSS 12.0 statistical software. Results: The analyzed reference intervals of Osteocalcin by using Hoffmann method are from 8.8~39.4 ng/mL to 6.3~28.8 ng/mL for the case of the age from 20 to 30, from 7.7~31.9 ng/mL to 5.9~17.4 ng/mL for the case of the age from 31 to 40, and from 8.0~36.0 ng/mL to 5.5~20.1 ng/mL for the case of the age from 41 to 50, and from 8.0~50.5 ng/mL to 6.7~27.0 ng/mL for the case of the age from 51 to 60, and from 12.9~55.9 ng/mL to 7.5~27.5 ng/mL for the case of the age from 61 to 80. Reference intervals of Osteocalcin were not in agreement with those recommended by the manufacturers. Conclusions: Osteocalcin is used as an indication of metabolic bone diseases. So in our study we wanted to provide reference intervals of Osteocalcin that can be useful to a clinical decisions. Also, previous reference intervals should not be re-used and new intervals should be set by continuous analyzing.

  • PDF

Comparison of Collimator Choice on Image Quality of I-131 in SPECT/CT (I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가)

  • Kim, Jung Yul;Kim, Joo Yeon;Nam-Koong, Hyuk;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.33-42
    • /
    • 2014
  • Purpose: I-131 scan using High Energy (HE) collimator is generally used. While, Medium Energy (ME) collimator is not suggested to use in result of an excessive septal penetration effects, it is used to improve the sensitivities of count rate on lower dose of I-131. This research aims to evaluate I-131 SPECT/CT image quality using by HE and ME collimator and also find out the possibility of ME collimator clinical application. Materials and Methods: ME and HE collimator are substituted as Siemens symbia T16 SPECT/CT, using I-131 point source and NEMA NU-2 IQ phantom. Single Energy Window (SEW) and Triple Energy Windows (TEW) are applied for image acquisition and images with CTAC and Scatter correction application or not, applied different number of iteration and sub set are reconstructed by IR method, flash 3D. By analysis of acquired image, the comparison on sensitivities, contrast, noise and aspect ratio of two collimators are able to be evaluated. Results: ME Collimator is ahead of HE collimator in terms of sensitivity (ME collimator: 188.18 cps/MBq, HE collimator: 46.31 cps/MBq). For contrast, reconstruction image used by HE collimator with TEW, 16 subset 8 iteration applied CTAC is shown the highest contrast (TCQI=190.64). In same condition, ME collimator has lower contrast than HE collimator (TCQI=66.05). The lowest aspect ratio for ME collimator and HE collimator are 1.065 with SEW, CTAC (+) and 1.024 with TEW, CTAC (+) respectively. Conclusion: Selecting a proper collimator is important factor for image quality. This research finding tells that HE collimator, which is generally used for I-131 scan emitted high energy ${\gamma}$-ray is the most recommendable collimator for image quality. However, ME collimator is also applicable in condition of lower dose, lower sensitive if utilizing energy window, matrix size, IR parameter, CTAC and scatter correction appropriately.

  • PDF

A Study for Analysis of Image Quality Based on the CZT and NaI Detector according to Physical Change in Monte Carlo Simulation (CZT와 NaI 검출기 물질 기반 물리적 변화에 따른 영상의 질 분석에 관한 연구: 몬테카를로 시뮬레이션)

  • Ko, Hye-Rim;Yoo, Yu-Ri;Park, Chan-Rok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.741-748
    • /
    • 2021
  • In this study, we evaluated image quality by changing collimator length and detector thickness using the Geant4 Application for Tomographic Emission (GATE) simulation tool. The gamma camera based on the Cadimium Zinc Telluride (CZT) and NaI detectors is modeled. In addition the images were acquired by setting 1, 2, 3, 4, 5, and 6 cm collimator length and 1, 3, 5, and 7 mm detector thickness using point source and phantom, which is designed by each diameter (4.45, 3.80, 3.15, 2.55 mm) with 447, 382, 317, and 256 Bq. The sensitivity (cps/MBq) for point source, and signal to noise ratio (SNR) and profile for phantom at the 4.45 mm by drwan the region of interests were used for quantitative analysis. Based on the results, the sensitivity according to collimator length is 2.3 ~ 48.6 cps/MBq for CZT detector, and 1.8 ~ 43.9 cps/MBq for NaI detector. The SNR using phantom is 3.6~9.8 for CZT detector, and 2.9~9.5 for NaI detector. As the collimator length is increased, the image resolution is also improved according to profile results based on the CZT and NaI detector. In addition, the senistivity for detector thickness is 0.04 ~ 0.12 cps/MBq for CZT detector, and 0.03 ~ 0.11 cps/MBq. The SNR using phnatom is 7.3~9.8 count for CZT detector, and 5.9~9.5 for NaI detector. As the detector thickness is increased, the image resolution is decreased according to profile results based on the CZT and NaI detector due to scatter ray. In conclusion, we need to set the geometric material such as detector and collimator to acuquire suitable image quality in nuclear medicine.

Long-Term Trend Analysis in Nuclear Medicine Examinations (핵의학 영상 검사의 중장기 추세 분석 - 서울 소재 일개 상급 종합병원을 중심으로 -)

  • Jung, Woo-Young;Shim, Dong-Oh;Choi, Jae-Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.15-28
    • /
    • 2019
  • Purpose Nuclear medicine was initially introduced in Korea in 1969 and widely applied to treat hyperthyroidism with $^{131}I$. Also, gamma camera was adopted in 1969 in the first place and its application has been growing continually in many ways. We analyzed long-term trend in nuclear medicine examinations for the last 2 decades. The purpose of this paper is to make predictions and to set both plans and directions on the development of nuclear medicine. Materials and Methods We analyzed the performance of nuclear medicine examinations and therapies performed in Asan Medical Center from 1998 to 2017. Results Results from the last 20 years regarding Bone scan, Renal scan, MUGA scan and $^{18}F$-FPCIT, Bone Mineral Density were on a increase. And Myocardium perfusion SPECT, Thyroid scan, Lung scan were on a decrease while $^{18}F-FDG$ PET maintained on a steady course. Until 2010 there was a positive performance with the therapy but after the excessive medical care in thyroid examination performance is at status quo. Key events such as a medical strike(2000), Middle-East Respiratory Syndrome (2015) influenced the overall performance of the therapy. Conclusion In order to promote a long-term growth in nuclear medicine examination and therapy, it is inevitable to respond to the changes in current medical environment. Furthermore, it is strongly suggested to put efforts to maintain and develop new examinations and clinical indicators.