• Title/Summary/Keyword: ${\gamma}$-Ray radiation

Search Result 886, Processing Time 0.025 seconds

Selection and Agronomic Traits of Radiation-induced Variants in Rice (방사선 이용 벼 돌연변이 계통 선발 및 농경 형질조사)

  • Lee, In-Sok;Kim, Dong-Sub;Lee, Sang-Jae;Song, Hi-Sub;Lim, Yong-Pyo;Lee, Young-Il
    • Journal of Plant Biotechnology
    • /
    • v.30 no.1
    • /
    • pp.19-25
    • /
    • 2003
  • Radiation technique in agriculture was initiated to develop mutant rice. Seeds of Daechungbyeo rice were irradiated with 250 Gy gamma ray for the purpose of inducing and selecting rice variants. Some quantitative traits of the variants in M$_{8}$ generation were evaluated and RAPD analysis was carried out. Variants showed a wider range of agronomic characteristics in both a positive and a negative direction compared with their original variety. The new mutants were characterized by an increased or decreased in plant height, lodging resistance and shorter panicle. RAPD analysis showed that polymorphic bands were presented in most of the primers. In comparison with the original variety, variants were classified into four groups through UPGMA analysis. Among mutants no. 91, 139, 140 and 141 was ranked as salt tolerance and the proline content of these mutants was more increased than that of original variety. The lines of 139, 140 and 141 had the highest genetic distance as compared to original variety in the dendrogram. It is expected that such variants will be useful not only for studying molecular genetics but also for breeding research and genetic analysis.s.

Dose- Response Curves of Mouse Jejunal Crypt Cells by Multifractionated Irradiation (다분할조사에 의한 마우스공장소낭선 세포의 선량반응곡선)

  • Hong, Seong-Eon;Ahn, Chi-Yul
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.89-97
    • /
    • 1986
  • Using as assay for jejunal crypt stem cell survival, dose-response curves for the reproductive capacity of crypt stem cells of mouse jejunum exposed to multifractionated gamma-ray irradiation (single, 2, 3, 4, 5, 8, 10, 12, and 16 fractions) were analyzed and single-dose survival curve of these cells was constructed. The following conclusion were drawn: 1) Survival curves for higher numbers of dose fractions were displaced to higher dose, and characterized by increasingly shallower slopes. 2) The single-dose survival curve had broad shoulder, Dq=460 cGy, remaining near-exponential over initial dose range 0 to 300 cGy, with initial slope 1Do=474 cGy. 3) At fractionated dose En the range of 180 to 450 cGy, the average recovered dose per fraction interval was approximately $50\%$ of the dose per fraction. 4) The value of $\alpha/\beta$ ratio by using of linear regression analysis for the reciprocal dose plots was 8.3 Gy which lied in the range of 6-14 Gy for early-reacting tissues. 5) The linear-quadratic model for dose-response formula offers valid approximations for at 1 doses to be used in radiotherapy, only two parameters to be determined, and considerable convenience in practical applications.

  • PDF

Dosimetric Study Using Patient-Specific Three-Dimensional-Printed Head Phantom with Polymer Gel in Radiation Therapy

  • Choi, Yona;Chun, Kook Jin;Kim, Eun San;Jang, Young Jae;Park, Ji-Ae;Kim, Kum Bae;Kim, Geun Hee;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.99-106
    • /
    • 2021
  • Purpose: In this study, we aimed to manufacture a patient-specific gel phantom combining three-dimensional (3D) printing and polymer gel and evaluate the radiation dose and dose profile using gel dosimetry. Methods: The patient-specific head phantom was manufactured based on the patient's computed tomography (CT) scan data to create an anatomically replicated phantom; this was then produced using a ColorJet 3D printer. A 3D polymer gel dosimeter called RTgel-100 is contained inside the 3D printing head phantom, and irradiation was performed using a 6 MV LINAC (Varian Clinac) X-ray beam, a linear accelerator for treatment. The irradiated phantom was scanned using magnetic resonance imaging (Siemens) with a magnetic field of 3 Tesla (3T) of the Korea Institute of Nuclear Medicine, and then compared the irradiated head phantom with the dose calculated by the patient's treatment planning system (TPS). Results: The comparison between the Hounsfield unit (HU) values of the CT image of the patient and those of the phantom revealed that they were almost similar. The electron density value of the patient's bone and brain was 996±167 HU and 58±15 HU, respectively, and that of the head phantom bone and brain material was 986±25 HU and 45±17 HU, respectively. The comparison of the data of TPS and 3D gel revealed that the difference in gamma index was 2%/2 mm and the passing rate was within 95%. Conclusions: 3D printing allows us to manufacture variable density phantoms for patient-specific dosimetric quality assurance (DQA), develop a customized body phantom of the patient in the future, and perform a patient-specific dosimetry with film, ion chamber, gel, and so on.

Radiological hazard assessment of soil from Kasik oil refinery, Nineveh, Iraq

  • M.I. Sayyed;Zainab Mowafaq Maria;Zakariya Adel Hussein;Laith Ahmed Najam;Berivan F. Namq;Taha Yaseen Wais;Mostafa Yuness Abdelfatah Mostafa;Howaida Mansour
    • Nuclear Engineering and Technology
    • /
    • v.56 no.11
    • /
    • pp.4782-4790
    • /
    • 2024
  • This study explored soil samples in a depth about 10-15 cm, 20 Soil samples were collected systematically from various locations to ensure a comprehensive assessment of the site within Kasik oil refinery, Nineveh Governorate, Iraq, whereby the determination of three natural radionuclides' specific activities was carried out via A p-type coaxial HPGe γ-ray spectrometer, manufactured by CANBERRA, USA. Natural radioactivity in soil is a significant factor for assessing environmental radiation exposure and potential health risks. The 226Ra, 232Th, and 40K radionuclides' mean specific activities in the soil samples were in the 13.10-33.43 Bq/kg, 10.58-22.76 Bq/kg, and 104.90-442.16 Bq/kg ranges, respectively, with overall means of 21.44 Bq/kg, 15.96 Bq/kg, and 255.50 Bq/kg, which are within the worldwide mean levels. The mean radium-equivalent activity (Raeq) was 63.94 Bq/kg, and thus below the 370 Bq/kg international limit. All of the samples' representative level index (Iγ) and internal and external hazard indices (Hin and Hex) were below the limit of unity, indicating low radiation hazards. The absorbed dose rate resulting from the three primordial radionuclides was in the 19.92-41.46 nGy/h range (mean: 30.20 nGy/h), with an annual effective dose of 0.04 mSv/y. The mean excess lifetime risk of cancer was found to be 0.15 × 10-3, and thus under the 0.29 × 10-3 world average. The study's results indicate that the natural radionuclides' measured specific activities in the soil samples are below the world recommended values, suggesting that the investigated area is safe in terms of radiological health risks.

ELECTROCHEMICAL STUDY ON THE CORROSION BEHAVIOUR OF DENTAL AMALGAM IN ARTIFICIAL SALIVA (인공타액에서 아말감의 부식거동에 관한 전기화학적 연구)

  • Kim, Yeoung-Nam;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.221-235
    • /
    • 1988
  • The purpose of this study was to observe characteristic properties through the polarization curves and EMPA images from 4 different types of amalgam obtained by using the potentiostats (EG & G PARC) & EPMA (Jeol JSM-35), to investigate the degree of corrosion of each phase of amalgam on the oxidation peak, and to identify corrosion products from the corroded amalgam by use of X-ray diffractometer(Rigaku). After each amlgam alloy and Hg were triturated as the direction of the manufacturer by means of the mechanical amalgamator(Shofu), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10mm in height and was condensed by means of routine manner. The specimen was removed from the mold and stored at room temperature for about 7 days. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to compare the corrosion behaviours of the amalgams in 0.9% saline solution(pH6.8~7.0) and artificial saliva (pH6.8~7.0) at $37^{\circ}C$. The open circuit potential was determined after 30 minutes' immersion of specimen in electrolyte and the potential scan was begun at the potential of 100mV cathodic from the corrosion potential. The scan rate was 1mV/sec and the surface area of amalgam exposed to the solution was 0.64$cm^2$ for each specimen. All the potentials reported are with respect to a saturated calomel electrode (SCE). EPMA images on the determined oxidation peaks of each amalgam in artificial saliva were observed. X-ray diffraction patterns of each sample were recorded before and after polarization in artificial saliva (Aristaloy, Caulk Spherical, Dispersalloy and Tytin: at +770mV, +585mV, +8.10m V and +680m V respectively) by use of a recording diffractometer. Nickel filtered Cu $K_{{\alpha}_1}$ radiation was used and sample was scanned at $4^{\circ}(2{\theta})/min.$ from $25^{\circ}$ to $80^{\circ}$. The following results were obtained. 1. Oxidation peak potential in artificial saliva shifted to more anodic direction than that in saline solution. 2. The corrosion potential of high copper amalgam was more anodic than the potential of low copper amalgam. 3. The current density was lower in artificial saliva than in saline solution. 4. One of the corrosion products, AgCl was identified by X-ray diffraction analysis. 5. ${\gamma}_2$ phase was the most susceptible to corrosion and e phase was stable in low copper amalgam and ${\eta}$' phase and Ag-Cu eutectic were susceptible to corrosion in high copper amalgam.

  • PDF

Effect of Gamma Irradiation on the Germination and Growth of Astragalus membranaceus (황기 발아 및 생장에 미치는 감마선 조사 효과)

  • Kim, Dong-Hwi;Park, Hee-Woon;Park, Chun-Geun;Sung, Jung-Sook;Seong, Nak-Sul
    • Korean Journal of Medicinal Crop Science
    • /
    • v.16 no.4
    • /
    • pp.238-241
    • /
    • 2008
  • Astragalus membranaceus have used as a medicinal herb and food in Korea. It is limited its harvest by diseases, pests and climate, therefore the main objective of Astragalus membranaceus breeding is the development of varities with the resistance for them. We used mutation breeding to obtain the genetic resources with the resistance for them. Pocheon, the local variety of Astragalus membranaceus, was treated with different levels Y-ray of $100{\sim}600$ Gy. There were investigated the sensitivity on germination and survival rate, plant height and the other characters. Germination rate from 4th day after sowing was significantly decreased above the 300 Gy as compared to the control. Compared to control, the decrements of survival rate were 32, 43, 63, 72, 84 and 89% for 100, 200, 300, 400, 500 and 600 Gy, respectively. The sensitive characters to Y-ray were plant height, number of branches per plant and survival rate, and the insensitive characters were number of leaves, length of leaf, and width of leaf. Plant height, number of branches per plant and survival rate seemed to be appropriate characters to decide the radiosensitivity, and radiation doses of $200{\sim}300$ Gy ($LD_{50}$) were recommend for mutation breeding.

A Convenient System for Film Dosimetry Using NIH-image Software

  • Kurooka, Masahiko;Koyama, Syuji;Obata, Yasunori;Homma, Mitsuhiko;Imai, Kuniharu;Tabushi, Katsuyoshi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.260-262
    • /
    • 2002
  • An accurate measurement of dose distribution is indispensable to perform radiation therapy planning. A measurement technique using a radiographic film, which is called a film dosimetry, is widely used because it is easy to obtain a dose distribution with a good special resolution. In this study, we tried to develop an analyzing system for the film dosimetry using usual office automation equipments such as a personal computer and an image scanner. A film was sandwiched between two solid water phantom blocks (30 ${\times}$ 30 ${\times}$ 15cm). The film was exposed with Cobalt-60 ${\gamma}$-ray whose beam axis was parallel to the film surface. The density distribution on the exposed film was stored in a personal computer through an image scanner (8bits) and the film density was shown as the digital value with NIH-image software. Isodose curves were obtained from the relationship between the digital value and the absorbed dose calculated from percentage depth dose and absorbed dose at the reference point. The isodose curves were also obtained using an Isodose plotter, for reference. The measurements were carried out for 31cGy (exposure time: 120seconds) and 80cGy (exposure time: 300seconds) at the reference point. While the isodose curves obtained with our system were drawn up to 60% dose range for the case of 80cGy, the isodose curves could be drawn up to 80% dose range for the case of 31cGy. Furthermore, the isodose curves almost agreed with that obtained with the isodose plotter in low dose range. However, further improvement of our system is necessary in high dose range.

  • PDF

RTD Analysis using Radioisotope Tracer on the Water Flow Characteristics in a Flocculator of Wastewater Treatment Facility (방사성동위원소 추적자를 이용한 폐수처리시설의 응집조에서 유입수의 체류시간분포 분석)

  • Kim, Jin-Seop;Jung, Sung-Hee;Kim, Jong-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • Using In-113m emitting gamma ray of 0.392MeV at radioisotope tracer the RTD (residence time distribution) of water in the flocculator of wastewater treatment facility was measured. The result was analyzed mathematically using K-RTD program constructed on the basis of CFSTR (constant flow stirred tank reactor) model. The mean residence time and the tank number are the main parameters which describe the flow behavior of the system. Those parameters were obtained in the fitting profess of the simulated curves to the experimental results. It was suggested to construct a modified numerical model to describe the bypass flow which was observed in the experiment.

Transmission Dose Measurement of Gamma-ray Using Tungsten Shield (텅스텐 차폐체의 감마선 투과선량 측정)

  • Han, Sang-Hyun;Koo, Bon-Yeoul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.124-129
    • /
    • 2018
  • This study was conducted to investigate the penetration dose and shielding rates of tungsten shields used in apron material by changing the type of source used in the nuclear medicine department, thickness of shielding material and distance between the source and detector. For the experiment, the source, shield, and detector were arranged in a straight line and measured with an inspector at a height of 100 cm. The highest shielding effect of tungsten was measured for $^{201}Tl$, while $^{123}I$ showed a higher shielding effect than $^{99m}Tc$. For the sources used in the experiment, the penetration dose decreased with distance and the shielding rate was measured with thicker thickness. However, the shielding rate of $^{13}1I$ and $^{18}F$ sources was found to be lower than when there was no shielding at 0.25 mmPb shield. Therefore, even if the radiation shielding effect of tungsten is high, considering the characteristics according to the type of source and the thickness of the shielding material, it may be helpful to reduce the exposure.

Preparation of Fibrous Adsorbent Modified with Iminodiacetic Acid and Its Co2+, Fe2+, and Pb2+ Adsorption Characteristics (이미노디아세트산을 함유한 섬유상 흡착제 제조 및 코발트, 철, 납 이온 흡착특성)

  • Yang, Hyun-Soo;Choi, Jun-Kyu;Nho, Young Chang
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.477-485
    • /
    • 1999
  • The grafting of 2,3-epoxypropylmethacrylate (GMA) onto polypropylene fabric was carried out by the $\gamma$-ray preirradiation grafting technique. Subsequently, the GMA-grafted polypropylene fabric was reacted with iminodiacetic acid (IDA) in different mixed solvents to prepare the fibrous metal adsorbent. The grafting extent was found to be dependent on the reaction time, temperature, preirradiation dose and dose rate. The effects of various mixed solvents on the IDA amination onto GMA-grafted polypropylene fabric were investigated. Compared with other mixed solvents, the extent of amination was highest in the dimethylsulfoxide (DMSO)/water, but the reaction did not occur in the water. The adsorption characteristics of various metal ions by the prepared adsorbent were examined when it was immersed in the 100 ppm metal ion solution. The amount of adsorption followed the order:$Pb^{2+}>Co^{2+}>Fe^{2+}$.

  • PDF