• Title/Summary/Keyword: ${\delta}$-connected

Search Result 118, Processing Time 0.033 seconds

Modeling and Control of a Grid Connected VSI using a Delta Connected LCL Filter ($\Delta$-결선 LCL 필터를 사용하는 삼상 계통 연계 인버터의 모델링과 제어)

  • Lee, Sang-In;Lee, Kui-Jun;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • There are two ways to connect an LCL filter in a grid-connected VSI. A wye connected LCL filter is general way, and the other is a delta connected LCL filter. While a model of a system with a wye connected LCL filter is calculated, a model of a system with a delta connected LCL filter is not formulated. Thus, we propose a mathematical model of a system with a delta connected LCL filter. Also, a comparative study of capacitor current harmonics of a delta connected LCL filter and a wye connected LCL filter is included. Experimental results exhibit that it is advantageous to control grid currents for a system with a delta connected LCL filter.

[ $G_{\delta}$ ]-CONNECTEDNESS AND $G_{\delta}$-DISCONNECTEDNESS IN FUZZY BITOPOLOGICAL SPACES

  • Roja, E.;Uma, M.K.;Balasubramanian, G.
    • East Asian mathematical journal
    • /
    • v.23 no.2
    • /
    • pp.159-174
    • /
    • 2007
  • In this paper, the concepts of pairwise fuzzy $G_{\delta}$-connected spaces and pairwise fuzzy $G_{\delta}$-extremally disconnected spaces are introduced. The concept of pairwise fuzzy $G_{\delta}$-basically disconnected spaces is defined. Characterizations of the above spaces are given besides giving several examples. Interrelations among the spaces introduced are discussed and some relevant counter examples are given.

  • PDF

Optimal Heating Load Identification using a DRNN (DRNN을 이용한 최적 난방부하 식별)

  • Chung, Kee-Chull;Yang, Hai-Won
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1231-1238
    • /
    • 1999
  • This paper presents an approach for the optimal heating load Identification using Diagonal Recurrent Neural Networks(DRNN). In this paper, the DRNN captures the dynamic nature of a system and since it is not fully connected, training is much faster than a fully connected recurrent neural network. The architecture of DRNN is a modified model of the fully connected recurrent neural network with one hidden layer. The hidden layer is comprised of self-recurrent neurons, each feeding its output only into itself. In this study, A dynamic backpropagation (DBP) with delta-bar-delta learning method is used to train an optimal heating load identifier. Delta-bar-delta learning method is an empirical method to adapt the learning rate gradually during the training period in order to improve accuracy in a short time. The simulation results based on experimental data show that the proposed model is superior to the other methods in most cases, in regard of not only learning speed but also identification accuracy.

  • PDF

Current Limit Strategy of Voltage Controller of Delta-Connected H-Bridge STATCOM under Unbalanced Voltage Drop

  • Son, Gum Tae;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.550-558
    • /
    • 2018
  • This paper presents the current limit strategy of voltage controller of delta-connected H-bridge static synchronous compensator (STATCOM) under an unbalanced voltage fault event. When phase to ground fault happens, the feasibility to heighten the magnitude of sagging phase voltage is considered by using symmetric transformation method in delta-structure STATCOM. And the efficiency to cover the maximum physical current limit of switching device is considered by using vector analysis method that calculate the zero sequence current for balancing the cluster energy in delta connected H-bridge STATCOM. The result is simple and obvious. Only positive sequence current has to be used to support the unbalanced voltage sag. Although the relationship between combination of the negative sequence voltage with current and zero sequence current is nonlinear, the more negative sequence current is supplying, the larger zero sequence current is required. From the full-model STATCOM system simulation, zero sequence current demand is identified according to a ratio of positive and negative sequence compensating current. When only positive sequence current support voltage sag, the least zero sequence current is needed.

Control of Open-Loop PWM Delta-Connected Motor-Drive Systems under One Phase Failure Condition

  • Sayed-Ahmed, Ahmed;Demerdash, Nabeel A.O.
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.824-836
    • /
    • 2011
  • A new fault-tolerant control topology for open-loop motor-drive systems with Delta-connected stator windings is introduced in this paper. This new control topology enables the operation of a three-phase induction machine as a two-phase machine fed by a three-phase inverter upon a failure in one of the motor phases. This topology utilizes the "open-Delta" configuration to independently control the current in each of the two remaining healthy phases. This new control technique leads to the alleviation of any torque pulsations resulting from the consequences of the asymmetrical conditions associated with this class of faults.

Circuital Characteristics of Ideal Three-phase Transformer Connections (이상적인 3상 변압기 결선의 회로 특성)

  • Park, In-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.9-12
    • /
    • 2008
  • Mathematical singularities of circuit equations with three-phase ideal transformer connections are studied. Three-wired wye-wye connections, delta-delta connections, and primary four-wired wye-delta connections are singular. The matrices of their circuit equations have zeros in their eigenvalues. Three-wired wye-delta connections, wye-wye-delta connections, and primary four-wired wye-wye connections are not singular. The physical meaning of their singularities is that they are sensitive and prone to be ill-conditioned. Equivalent shunt admittances representing ion losses and magnetizing inductances make the singular matrices non-singular in wye-connected circuits. And, equivalent series impedances representing copper losses and leakage inductances make the singular matrices non-singular in delta-connected circuits. The tableau analysis is used for the study.

  • PDF

A Three-Phase Four-Wire DSTATCOM for Power Quality Improvement

  • Singh, Bhim;Jayaprakash, P.;Kothari, D.P.
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.259-267
    • /
    • 2008
  • Power quality improvement in a three-phase four-wire system is achieved using a new topology of DSTATCOM (distribution static compensator) consisting of a star/delta transformer with a tertiary winding and a three-leg VSC (voltage source converter). This new topology of DSTATCOM is proposed for power factor correction or voltage regulation along with harmonic elimination, load balancing and neutral current compensation. A tertiary winding is introduced in each phase for a delta connected secondary in addition to the star-star windings and this delta connected winding is responsible for neutral current compensation. The dynamic performance of the proposed DSTATCOM system is demonstrated using MATLAB with its Simulink and Power System Blockset (PSB) toolboxes under varying loads. The capacitor supported DC bus of the DSTATCOM is regulated to the reference voltage under varying loads.

Enhanced RBF Network by Using Auto- Turning Method of Learning Rate, Momentum and ART2

  • Kim, Kwang-baek;Moon, Jung-wook
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.11a
    • /
    • pp.84-87
    • /
    • 2003
  • This paper proposes the enhanced REF network, which arbitrates learning rate and momentum dynamically by using the fuzzy system, to arbitrate the connected weight effectively between the middle layer of REF network and the output layer of REF network. ART2 is applied to as the learning structure between the input layer and the middle layer and the proposed auto-turning method of arbitrating the learning rate as the method of arbitrating the connected weight between the middle layer and the output layer. The enhancement of proposed method in terms of learning speed and convergence is verified as a result of comparing it with the conventional delta-bar-delta algorithm and the REF network on the basis of the ART2 to evaluate the efficiency of learning of the proposed method.

  • PDF

CONNECTEDNESS IN IDEAL PROXIMITY SPACES

  • Singh, Beenu;Singh, Davinder
    • Honam Mathematical Journal
    • /
    • v.43 no.1
    • /
    • pp.123-129
    • /
    • 2021
  • Two new concepts, namely, ��∗-connectedness and ��∗-component are introduced by using ideal in proximity spaces. A relation of ��∗-connectedness with different types of connectedness that are considered in literature before is studied. It is shown that ��∗-connectedness is a contractive property.

Analytic Model of Four-switch Inverter-fed Driving System for Wye or Delta-connected Motor with Current Ripple Reduction Scheme

  • Lee, Dong-Myung;Jung, Jin-Woo;Heo, Seo Weon;Kim, Tae Heoung
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.109-116
    • /
    • 2016
  • This paper proposes an analytic model for four-switch inverter (FSI)-driven wye (Y) or delta (Δ)-connected motors with a current ripple reduction algorithm. FSIs employ four switches in controlling three-phase load instead of using six switches. They have split dc-link stage, and due to this inherent structure there exists the voltage difference between upper and lower capacitors, which results in distortion of the inverter output voltage. To study characteristics of FSIs, this paper presents an advanced simulation models of FSI-driven control system for 3-phase motor that can has a wire connection either Y or Δ. In addition, this paper introduces a current ripple reduction scheme that mitigates degradation of control performance due to the voltage difference between the dc-link capacitors. The validity of the proposed method and the analytic model is verified by simulations and experiments carried out with 1-HP induction machine with Y or Δ-connection