• Title/Summary/Keyword: $^{18}FDG-PET$

Search Result 530, Processing Time 0.03 seconds

Metabolic Topography of Parkinsonism

  • Kim, Jae-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.2
    • /
    • pp.141-151
    • /
    • 2007
  • Parkinson's disease is one of the most frequent neurodegenerative diseases, which mainly affects the elderly. Parkinson's disease is often difficult to differentiate from atypical parkinson diorder such as progressive supranuclear palsy, multiple system atrophy, dementia with Lewy body, and corticobasal ganglionic degeneration, based on the clinical findings because of the similarity of phenotypes and lack of diagnostic markers. The accurate diagnosis of Parkinson's disease and atypical Parkinson disorders is not only important for deciding on treatment regimens and providing prognosis, but also it is critical for studies designed to investigate etiology and pathogenesis of parkinsonism and to develop new therapeutic strategies. Although degeneration of the nigrostriatal dopamine system results in marked loss of striatal dopamine content in most of the diseases causing parkinsonism, pathologic studies revealed different topographies of the neuronal cell loss in Parkisonism. Since the regional cerebral glucose metabolism is a marker of integrated local synaptic activity and as such is sensitive to both direct neuronal/synaptic damage and secondary functional disruption at synapses distant from the primary site of pathology, an assessment of the regional cerebral glucose metabolism with F-18 FDG PET is useful in the differential diagnosis of parkinsonism and evaluating the pathophysiology of parkisonism.

Usefulness of Prone Position on PET-CT in Breast Cancer (유방암 PET-CT 검사에서 Prone(복와위)자세의 유용성 평가)

  • Park, Hoon-Hee;Kim, Sei-Yung;Kim, Jung-Yul;Park, Min-Soo;Lim, Han-Snag;Jung, Suk;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho;Lee, Yung-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.44-48
    • /
    • 2008
  • Purpose: In FDG-PET/CT of breast cancer, a sensitivity was 80~96% and a specificity was 75~95% commonly. It was valuable to identify a cancer in early stage been difficult in Mammography. Most of the PET/CT scans have been examined on supine position, so, the image of breast has been acquired by reconstructed whole body scan image. However, using prone position with a compensator, a shape of breast was reassembly shown to be real by gravity. Therefore, the purpose of this study was to evaluate diagnostic value of prone position in FDG PET-CT of breast cancer. Materials and Methods: 30 female patients with doubtful or positive breast cancer were examined. The PET-CT whole body scan was acquired at 60 minutes after $^{18}F$-FDG injection on Supine position. Then, regional breast spot scan was progressed on prone position using a compensator. Each image was evaluated by physicians blinded to patient's data, and statistical analysis did through SUVs measured in PET-CT images. Results: In 27 of 30 patients, prone position was shown accurate discrimination and diagnostic value, but in another 3 patients had a lesion 1cm below, PET-CT couldn't detect it, unlike MRI. Consequently, prone position distinguished a lesion better than Supine position, because of low degree of metamorphosis by gravity. The SUVs analysis of each position was significant (p value=0.004). Conclusion: In PET-CT of breast cancer, prone position could detect micrometastasis as well as primary lesion, better than supine position. Therefore, this study proposes that any technical change considered morphological feature like prone position can offer adequate and useful diagnostic information, together with complementary quantitative analysis.

  • PDF

Asymmetry of Medial and Lateral Temporal Regional Glucose Metabolism in Temporal Lobe Epilepsy by F-18-FDG PET (측두엽 간질에서 F-18-FDG PET에 나타난 측두엽 내외측 부위별 대사의 차이)

  • Lee, Dong-Soo;Yeo, Jeong-Seok;Song, Ho-Cheon;Lee, Sang-Kun;Kim, Hyun-Jip;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.28-39
    • /
    • 1999
  • Purpose: We investigated the difference of glucose metabolism of medial and lateral temporal lobes of patients with temporal lobe epilepsy (TLE) utilizing quantitative comparison of regional metabolic activities using asymmetric index. Materials and Methods: We studied 19 pathologically proven mesial TLE and 25 lateral TLE patients. Lateral TLE patients were either normal on magnetic resonance imaging (cryptogenic: n=14) or had structural lesions (lesional: n= 11). Asymmetric index (ASI) was calculated as [(ipsilateral-contralateral)/(ipsilateral+contralateral)]${\times}200$. Results: ASI of medial and lateral lobes of mesial TLE was decreased ($-16.4{\pm}8.3$ and $-12.1{\pm}5.5$, respectively). In cryptogenic lateral TLE, ASI of lateral temporal lobe was decreased ($-11.8{\pm}4.7$), whereas that of medial temporal lobe was not decreased ($-4.6{\pm}6.3$). ASI of medial lobe of lesional lateral TLE was $-7.3{\pm}9.1$, which was significantly different from that of mesial TLE (p<0.05). Patients with lesional lateral TLE had evident metabolic defects or decrease (ASI: $-22{\pm}10.5$) in lateral temporal lobe. While we could not find the difference of metabolic activity in lateral temporal lobes between cryptogenic lateral TLE and mesial TLE patients, the difference of metabolic activity was significant in medial temporal lobes which was revealed by ASI quantitation. Conclusion: Asymmetric decrease of metabolic activity in both medial and lateral temporal lobes indicates medial temporal epilepsy. Symmetry of metabolic activity in medial temporal lobe combined with asymmetry of that in lateral temporal lobe may give hints that the epileptogenic zone is lateral.

  • PDF

Effect of MRI Media Contrast on PET/MRI (PET/MRI에 있어 MRI 조영제가 PET에 미치는 영향)

  • Kim, Jae Il;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • Purpose: Integrated PET/MRI has been developed recently has become a lot of help to the point oncologic, neological, cardiological nuclear medicine. By using this PET/MRI, a ${\mu}-map$ is created some special MRI sequence which may be divided parts of the body for attenuation correction. However, because an MRI contrast agent is necessary in order to obtain an more MRI information, we will evaluate to see an effect of SUV on PET image that corrected attenuation by MRI with contrast agent. Materials and Methods: As PET/MRI machine, Biograph mMR (Siemens, Germany) was used. For phantom test, 1mCi $^{18}F-FDG$ was injected in cylinderical uniformity phantom, and then acquire PET data about 10 minutes with VIBE-DIXON, UTE MRI sequence image for attenuation correction. T1 weighted contrast media, 4 cc DOTAREM (GUERBET, FRANCE) was injected in a same phatnom, and then PET data, MRI data were acquired by same methodes. Using this PET, non-contrast MRI and contrast MRI, it was reconstructed attenuation correction PET image, in which we evanuated the difference of SUVs. Additionally, for let a high desity of contrast media, 500 cc 2 plastic bottles were used. We injected $^{18}F-FDG$ with 5 cc DOTAREM in first bottle. At second bottle, only $^{18}F-FDG$ was injected. and then we evaluated a SUVs reconstructed by same methods. For clinical patient study, rectal caner-pancreas cancer patients were selected. we evaluated SUVs of PET image corrected attenuastion by contrast weighted MRI and non-contrast MRI. Results: For a phantom study, although VIBE DIXON MRI signal with contrast media is 433% higher than non-contrast media MRI, the signals intensity of ${\mu}-map$, attenuation corrected PET are same together. In case of high contrast media density, image distortion is appeared on ${\mu}-map$ and PET images. For clinical a patient study, VIBE DIXON MRI signal on lesion portion is increased in 495% by using DOTAREM. But there are no significant differences at ${\mu}-map$, non AC PET, AC-PET image whether using contrast media or not. In case of whole body PET/MRI study, %diff between contras and non contrast MRAC at lung, liver, renal cortex, femoral head, myocardium, bladder, muscle are -4.32%, -2.48%, -8.05%, -3.14%, 2.30%, 1.53%, 6.49% at each other. Conclusion: In integrated PET/MRI, a segmentation ${\mu}-map$ method is used for correcting attenuation of PET signal. although MRI signal for attenuation correciton change by using contrast media, ${\mu}-map$ will not change, and then MRAC PET signal will not change too. Therefore, MRI contrast media dose not affect for attenuation correction PET. As well, not only When we make a flow of PET/MRI protocol, order of PET and MRI sequence dose not matter, but It's possible to compare PET images before and after contrast agent injection.

  • PDF

Standardized Uptake Values Highly Correlate with Tumor Size and Fuhrman Grade in Patients with Clear Cell Renal Cell Carcinoma

  • Polat, Emre Can;Otunctemur, Alper;Ozbek, Emin;Besiroglu, Huseyin;Dursun, Murat;Ozer, Kutan;Horsanali, Mustafa Ozan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.18
    • /
    • pp.7821-7824
    • /
    • 2014
  • Background: We investigated the correlation between standardized uptake value (SUVmax), tumor size and Fuhrman grade in patients with renal cell carcinoma (RC). Materials and Methods: We retrospectively analyzed the data of 54 patients with clear cell renal cell carcinoma histopathologically diagnosed who underwent fluorine-18 fluoro-2 deoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) between January 2005 and March 2014. Results: Avarage tumor sizes were $5.64{\pm}1.85$, $6.85{\pm}2.24$ and $7.98{\pm}2.45$ in low, medium and high SUVmax groups, respectively. The Spearman's correlation coefficient between the tumor size and SUVmax was 0.385 (p=0.004) and between the Fuhrman grade and SUVmax was 0.578 (p<0.001). Conclusions: SUVmax appears highly correlated with tumor size and Fuhrman grade in patients with histopathologically confirmed clear cell RC. Multicenter studies are needed to provide larger series for more accurate results.

Comparative Evaluation of 18F-FDG Brain PET/CT AI Images Obtained Using Generative Adversarial Network (생성적 적대 신경망(Generative Adversarial Network)을 이용하여 획득한 18F-FDG Brain PET/CT 인공지능 영상의 비교평가)

  • Kim, Jong-Wan;Kim, Jung-Yul;Lim, Han-sang;Kim, Jae-sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.15-19
    • /
    • 2020
  • Purpose Generative Adversarial Network(GAN) is one of deep learning technologies. This is a way to create a real fake image after learning the real image. In this study, after acquiring artificial intelligence images through GAN, We were compared and evaluated with real scan time images. We want to see if these technologies are potentially useful. Materials and Methods 30 patients who underwent 18F-FDG Brain PET/CT scanning at Severance Hospital, were acquired in 15-minute List mode and reconstructed into 1,2,3,4,5 and 15minute images, respectively. 25 out of 30 patients were used as learning images for learning of GAN and 5 patients used as verification images for confirming the learning model. The program was implemented using the Python and Tensorflow frameworks. After learning using the Pix2Pix model of GAN technology, this learning model generated artificial intelligence images. The artificial intelligence image generated in this way were evaluated as Mean Square Error(MSE), Peak Signal to Noise Ratio(PSNR), and Structural Similarity Index(SSIM) with real scan time image. Results The trained model was evaluated with the verification image. As a result, The 15-minute image created by the 5-minute image rather than 1-minute after the start of the scan showed a smaller MSE, and the PSNR and SSIM increased. Conclusion Through this study, it was confirmed that AI imaging technology is applicable. In the future, if these artificial intelligence imaging technologies are applied to nuclear medicine imaging, it will be possible to acquire images even with a short scan time, which can be expected to reduce artifacts caused by patient movement and increase the efficiency of the scanning room.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

Facile Fabrication of Animal-Specific Positioning Molds For Multi-modality Molecular Imaging (다중 분자 영상을 위한 간편한 동물 특이적 자세 고정틀의 제작)

  • Park, Jeong-Chan;Oh, Ji-Eun;Woo, Seung-Tae;Kwak, Won-Jung;Lee, Jeong-Eun;Kim, Kyeong-Min;An, Gwang-Il;Choi, Tae-Hyun;Cheon, Gi-Jeong;Chang, Young-Min;Lee, Sang-Woo;Ahn, Byeong-Cheol;Lee, Jae-Tae;Yoo, Jeong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.401-409
    • /
    • 2008
  • Purpose: Recently multi-modal imaging system has become widely adopted in molecular imaging. We tried to fabricate animal-specific positioning molds for PET/MR fusion imaging using easily available molding clay and rapid foam. The animal-specific positioning molds provide immobilization and reproducible positioning of small animal. Herein, we have compared fiber-based molding clay with rapid foam in fabricating the molds of experimental animal. Materials and Methods: The round bottomed-acrylic frame, which fitted into microPET gantry, was prepared at first. The experimental mice was anesthetized and placed on the mold for positioning. Rapid foam and fiber-based clay were used to fabricate the mold. In case of both rapid foam and the clay, the experimental animal needs to be pushed down smoothly into the mold for positioning. However, after the mouse was removed, the fabricated clay needed to be dried completely at $60^{\circ}C$ in oven overnight for hardening. Four sealed pipet tips containing $[^{18}F]FDG$ solution were used as fiduciary markers. After injection of $[^{18}F]FDG$ via tail vein, microPET scanning was performed. Successively, MRI scanning was followed in the same animal. Results: Animal-specific positioning molds were fabricated using rapid foam and fiber-based molding clay for multimodality imaging. Functional and anatomical images were obtained with microPET and MRI, respectively. The fused PET/MR images were obtained using freely available AMIDE program. Conclusion: Animal-specific molds were successfully prepared using easily available rapid foam, molding clay and disposable pipet tips. Thanks to animal-specific molds, fusion images of PET and MR were co-registered with negligible misalignment.

Kikuchi Disease Manifesting as Multifocal Lymphadenopathy and Splenomegaly: Ultrasonography, CT, and 18F-FDG PET/CT Findings Mimicking Lymphoma (다발성 림프절염과 비장종대로 발현하여 림프종으로 오인된 기쿠치병의 초음파, CT, 18F-FDG PET/CT 소견)

  • Moin Ha;Bo-Kyung Je;Eung-Seok Lee;Seong Wook Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1486-1491
    • /
    • 2020
  • Kikuchi disease is a type of benign, self-limiting necrotizing lymphadenitis that occurs most commonly in young women and usually manifests as palpable cervical lymph nodes and fever. Patients with an unusual location of lymph node involvement can be misdiagnosed with malignant disease. Here, we report a case of Kikuchi disease in a 15-year-old girl presenting with persistent fever for 2 weeks. Imaging studies, including ultrasonography, CT, and 18F-fluorodeoxyglucose PET/CT, revealed splenomegaly and enlarged lymph nodes in the neck, axilla, abdomen, retroperitoneum, and inguinal region. Laparoscopic excision of the celiac lymph nodes confirmed histiocytic necrotizing lymphadenitis, also known as Kikuchi disease. Conservative treatment with corticosteroids improved the patient's condition.

Spinal Accessory Neuropathy Secondary to Diffuse Large B-Cell Lymphoma (미만성 거대 B세포 림프종으로 인한 척수더부신경병증)

  • Kim, Kunwoo;Lee, Yong-Taek;Yoon, Kyung Jae;Lee, Jung-Sang;Hwang, Jin-Tae;Do, Jong Geol
    • Clinical Pain
    • /
    • v.18 no.1
    • /
    • pp.52-57
    • /
    • 2019
  • Spinal accessory neuropathy (SAN) is commonly caused by an iatrogenic procedure, and that caused by tumors is very rare. We present a case of a 49-year-old man suffering from weakness in the right trapezius and sternocleidomastoid muscle. An electrophysiology study confirmed proximal SAN. Fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) revealed a diffuse large B-cell lymphoma compressing the right spinal accessory nerve. Ultrasonography showed definite atrophy on the trapezius and sternocleidomastoid muscles. In addition, post-chemotherapy FDG-PET/CT showed increased FDG uptake in the right upper trapezius, suggestive of denervation. This is the first report of SAN caused by direct compression by a diffuse large B-cell lymphoma, comprehensively assessed by an electrophysiology study, ultrasonography, and FDG-PET/CT.