• Title/Summary/Keyword: $\psi$-q-n pattern

Search Result 5, Processing Time 0.02 seconds

Properties and classification of air discharge by Kohonen network (기중방전의 특성분석과 Kohonen network에 의한 방전원의 패턴분류)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.704-707
    • /
    • 1999
  • Partial discharge(PD) in air insulated electric power systems is responsible for considerable power lossesfrom high voltage transmission lines. PD in air often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge and may give rise to interference in ommunication systems. PD can indicate incipient failure. Thus understanding and classification of PD in air is very important to discern source of PD. In this paper, we investigated PD in air by using statical method. We classified air discharge with corona, surface discharge and cavity discharge by source of discharge. we used the mean pulse-height phase distribution $H_{qmean}(\psi)$, the max pulse-height phase distribution $H_{qmax}(\psi)$ , the pulse count phase distribution $H_n(\psi)$ and the max pulse height vs. repetition rate $H_{q}(n)$ for analysis PD pattern. We used statistical operators, such as skewness(S+. S-1, kurtosis(K+, K-), mean phase(AP+. AP-), cross-correlation factor(CC) and asymmetry from the distribution.

  • PDF

Properties of Partial Discharge accompanying with Electrical Tree in LDPE (저밀도 폴리에틸렌에서 전기트리에 수반되는 부분방전의 특성)

  • 이광우;박영국;강성화;장동욱;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.234-238
    • /
    • 1999
  • The correlation between shape of electrical trees and partial discharge(PD) pulses in low density polyethylene(LDPE) were discussed. We observed growth feature of electrical tree by using optical microscope. On the basis of experimental results of measurements of trees occurring in the needle-plane arrangement with needle shape void and without needle shape void , statistical quantities are derived, which are relevant to PD pulse amplitude and phase. The PD quantities detected by partial discharge detector. we were analyzed q-n distribution pattern and $\psi$ -q-n distribution pattern. In this experiment, electrical trees in the needle-plane arrangement with needle shape void propagated branch type tree and in the needle-plane arrangement without needle shape void propagated bush type tree

  • PDF

Analysis PD Pattern in PET film with semiconductor particle (반도전 입자를 갖는 PET film내에서의 PD Pattern 분석)

  • Choi, Pil-Moon;Jeong, Byung-Sun;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2399-2401
    • /
    • 1999
  • This paper indicate that phase resolved partial discharge pattern are investigated on PET films with semiconductor particle. In this study, we measured phase-resolved PD pattern and statistical parameter from PET specimens according to containing semiconductor particle. Measurement system is the conventional PD detector using digital signal processing technique. The relationship of semiconductor particle in PET film was discussed through the difference of $\psi$-q-n distribution and statistical analysis.

  • PDF

Properties of PD Pulses Accompanying with Bush-type Tree in LDPE (저밀도 폴리에틸렌에서 부시형 전기트리에 수반되는 부분방전 펄스의 특성)

  • 강성화;박영국;정수현;이광우;임기조
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.12
    • /
    • pp.1055-1059
    • /
    • 1998
  • The correlation between the propagation of electrical tree and distributions of partial discharge(PD) pulses accompanying with electrical tree of bush type in low density polyethylene were discussed. We measured the growth of electrical tree by using optical microscope and PD data simultaneously. The PD data detected and analyzed were PD magnitude, repetition rate, average discharge power, average phase angle, and $\psi$-q-n distribution pattern. The average discharge power and repetition rate of PD had good linear relation with area of tree. Repetition rate and peak discharge magnitude and width of discharge phase angle increased with the tree.

  • PDF

Recognition of Partial Discharge Patterns (부분방전 패턴의 인식)

  • 이준호;이진우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.2
    • /
    • pp.8-17
    • /
    • 2000
  • In this work, two approaches were proposed for the recognition of partial discharge patterns. The first approach was neural network with backpropagation algorithm, and the second approach was angle calculation between t재 operator vectors. PD signals were detected using three electrode systems; IEC(b), needle-plane and CIGRE method II electrode system. Both of neural network and angle comparison method showed good recognition performance for the patterns similar to the trained patterns. And the number of operators to be used had a great influence on the recognition performance to the untrained patterns.

  • PDF