Calculation of the Least Significant Change Value of Bone Densitometry Using a Dual-Energy X-ray Absorptiometry System

  • Han-Kyung Seo (Department of Nuclear Medicine, Jeonbuk National University Hospital) ;
  • Do-Cheol Choi (Department of Nuclear Medicine, Jeonbuk National University Hospital) ;
  • Cheol-Min Shim (Department of Nuclear Medicine, Jeonbuk National University Hospital) ;
  • Jin-Hyeong Jo (Department of Nuclear Medicine, Jeonbuk National University Hospital)
  • Received : 2023.04.21
  • Accepted : 2023.06.08
  • Published : 2023.11.30

Abstract

Purpose: The precision error of a bone density meter reflects the equipment and reproducibility of results by an examiner. Precision error values can be expressed as coefficient of variation (CV), CV%, and root mean square-SD (RMS-SD). The International Society for Clinical Densitometry (ISCD) currently recommends using RMS-SD as the precision error value. When a 95% confidence interval is applied, the least significant change (LSC) value is calculated by multiplying the precision error value by 2.77. Exceeding the LSC value reflects a significant difference in measured bone density. Therefore, the LSC value of a bone density equipment is an essential factor for accurately determining a patient's bone density. Accordingly, we aimed to calculate the LSC value of a bone density meter (Lunar iDXA, GE) and compare it with the value recommended by the ISCD. We also assessed whether the value measured by the iDXA equipment was below the LSC value recommended by ISCD. Material and Methods: The bone densities of the lumbar spine and thighs of 30 participants were measured twice, and the LSC values were calculated using the precision calculation tool provided by the ISCD (http://www.iscd.org). To check the reproducibility of the measurement, patients were asked to completely dismount from the equipment after the first measurement; the patient was then repositioned before proceeding with the second measurement. Results: The LSC values derived using the CV% values recommended by the ISCD were 5.3% for the lumbar spine and 5.0% for the thigh. The LSC values measured using our bone density equipment were 2.47% for the lumbar spine and 1.61% for the thigh. The LSC value using RMS-SD was 0.031 g/cm2 for the lumbar spine and 0.017 g/cm2 for the thigh. Conclusion: that the findings confirm that the CV% value measured using our bone density meter and the LSC value using RMS-SD were maintained very stably. This can be helpful for obtaining accurate measurements during bone density follow-up examinations.

Keywords

References

  1. Cameron JR, Sorenson J. An improved method. Science 1964;142:230-2. https://doi.org/10.1126/science.142.3589.230
  2. Yang SH. Principles of bone densitometry. Kor J Meno Med 1995;1:31-7.
  3. Cho JA, Kim SW, Kim E, Koo JR, Kim YT, Lim CH, Han KO, Jeong HY, Han IK, Min HK. Standardization for dual energy x-ray absorptiometry. Kor JM 1997;52(4):445-9
  4. Rah SK, Yoon SR, Chu SO. Comparative study of bone mineral density of women over 50 years old related with age, weight and height. J Soonchunhyang Med Coll 2000;6(2):407-415.
  5. Mazess RB. Dual-energy x-ray absorptiometry for the management of bone disease. Phys Med Rehabil Clin North Am 1995;6:507-537. https://doi.org/10.1016/S1047-9651(18)30453-4
  6. Sarafrazi N, Wambogo EA, Shepherd JA. Osteoporosis or low bone mass in older adults. 2017-2018 NCHS data brief 2021;405:1-8
  7. Hansen D, Pelizzari P, Pyenson B. Medicare cost of osteoporotic fractures-2021 updated report: The clinical and cost burden of fractures associated with osteoporosis. Miliman research report 2021.
  8. Kim DY. Clinical application of bone mineral density measurement. Kor J Nucl Med 2004;38(4):275-281.
  9. Shepherd JA, Schousboe JT, Broy SB, Engelke K, Leslie WD. Executive summary of the 2015 iscd position development conference on advanced measures from DXA and QCT: fracture prediction beyond BMD. J Clin Densitom 2015;18:274-286 https://doi.org/10.1016/j.jocd.2015.06.013
  10. Lenchick L, Kiebzak GM, Blunt BA. What is the role of serial bone mineral density measurement in patient management. J Clin Densitom 2002;5:S29-38 https://doi.org/10.1385/JCD:5:3S:S29