DOI QR코드

DOI QR Code

Evaluation of Moment Transfer Efficiency According to the Connection Length of the Column Flange and the Beam Web of the H-beam Column Connection

H형강 보-기둥 접합부의 보 웨브 단부접합길이에 따른 모멘트전달효율 평가

  • Received : 2022.10.24
  • Accepted : 2022.11.22
  • Published : 2022.12.31

Abstract

In this study, in order to compare the seismic performance of steel structure beam-column connection details and non-scallop connection details mainly used in Korea, a full-scale static cyclic loading test and FEM analysis were conducted through the same modeling as the experiment. For quantitative numerical comparison, the strain concentration ratio and moment transfer efficiency used in previous studies were cited. As the welding area of the beam web decreased, the deformation rate of the beam flange increased, and the plastic deformation capacity according to the rotation angle decreased or brittle fracture occurred. Comparing the analysis results with the experimental results, the possibility of brittle fracture tended to increase when the web welding ratio for the total cross-sectional area of H-shaped fell below 60%.

본 연구는 국내에서 주로 사용되는 강구조 보-기둥 접합상세와 논스캘럽접합상세의 내진성능을 비교하기 위해 실대형 정적반복실험과 실험과 동일한 모델링 통한 FEM해석을 진행하였다. 정량적인 수치비교를 위해 이전연구에서 사용된 변형률집중지수와 모멘트전달효율을을 인용하였다. 보 웨브의 용접면적 감소에 따라 플랜지 부분의 변형률이 증가되어 회전각에 따른 소성변형능력이 감소되거나 취성파단이 일어나는 현상을 보였다. 해석결과와 실험결과 비교시 H형 전체단면적에 대한 웨브 용접비가 60%이하로 떨어질 경우 취성파단이 일어날 가능성이 높아지는 경향이 나타났다.

Keywords

Acknowledgement

이 연구는 2022년도 산업통상자원부 및 산업기술평가관리원(KEIT) 연구비 지원에 의한 연구임('20017750').

References

  1. Kim, Y.J., OH, S.H., and MOON, T.S. (2004), Analytical study on relationship between moment transfer efficiency of a beam web and strain concentration at steel moment connections, Journal of Korean Society of Steel Construction, KSSC, 16(5), 695-703. (in Korean).
  2. Kim, Y.J., and OH, S.H. (2006), Evaluation of moment transfer efficiency of a beam web at RHS column-to-beam connections, Earthquake Engineering Society of Korea, EESK, 10(4), 67-76. (in Korean).
  3. Kim, S.H, Kim, Y.J, OH, S.H., and MOON, T.S. (2004), Analytical study on relationship of moment transfer efficiency and strain concentration of steel beam to column connections, Architectural Institute of Korea, 24(1), 107-110. (in Korean).
  4. KSSC. (2018), KS New grade steel structure design, Korean Society of Steel Construction. (in Korean).
  5. OH, S.H., Kim, Y.H., Kim, Y.J., Ryu, H.,S., and Park, H.Y. (2020), An analytical study on the deep H-shaped beam-to-column connections with double slit damper type energy absorption system, Journal of Korean Society of Steel Construction, KSSC, 32(1), 11-22. (in Korean). https://doi.org/10.7781/kjoss.2020.32.1.011
  6. KSSC. (2022), 3rd revision of the detailed quidelines for standard joining of building steel structures.
  7. KATS, KSCI. (2018), KS D 3503 Rolled steels for general structure.
  8. KATS, KSCI. (2017), KS D 0801 Test pieces for tensile test for metallic materials.
  9. Korea Construction Standards Center. (2019), KDS 41.
  10. OH, S.H., and Park, H.Y. (2014), A study on deformation capacity of high strength steel beam-to-column connections according to welding detail at beam end, Journal of Korean Society of Steel Construction, 26(4), 335-348. (in Korean). https://doi.org/10.7781/KJOSS.2014.26.4.335
  11. Korea Construction Standards Center. (2019), KDS41.
  12. SIMULA, ABAQUS 6.11 abaqus/CAE User's Maual Construction, 26(5), 229-239. (in Korean).
  13. Park H.Y. (2017), Seismic Performance of Damage Controlled Structural System with Energy Absorption Devices at Beam End, Ph.D. Dissertation, University of Pusan, Korea (in Korean).
  14. KATS, KSCI. (2019), KS B 1010 Set of high strength hexagon bolt, hexagon nut and plain washers for friction grip joints.