DOI QR코드

DOI QR Code

대형 버스의 엔진룸에서 흡음재이탈 및 전기적인 단락에 관련된 화재 사례 고찰

A Study for Fire Examples Involved with Absorbing Material Breakaway and Electric Short in Engine Room of a Large Bus

  • 이일권 (대림대학교 자동차공학과) ;
  • 국창호 (대림대학교 자동차공학과) ;
  • 함성훈 (대림대학교 자동차공학과) ;
  • 이영숙 (대림대학교 자동차공학과) ;
  • 황한섭 (수원과학대학교 기계과) ;
  • 유창배 (신성대학교 자동차계열) ;
  • 문학훈 (오산대학교 자동차과) ;
  • 이정호 (인하대학교대학원 기계공학과)
  • Lee, IL Kwon (Dept. of Automotive Engineering, Daelim University College) ;
  • Kook, Chang Ho (Dept. of Automotive Engineering, Daelim University College) ;
  • Ham, Sung Hoon (Dept. of Automotive Engineering, Daelim University College) ;
  • Lee, Young Suk (Dept. of Automotive Engineering, Daelim University College) ;
  • Hwang, Han Sub (Dept. of Mechanical Engineering, Suwon Science College) ;
  • You, Chang Bae (Dept. of Automotive Engineering, Shin Sung University) ;
  • Moon, Hak Hoon (Dept. of Automotive Engineering, Osan University) ;
  • Lee, Jeong Ho (Graduate School of Mechanical Engineering, Inha University)
  • 투고 : 2020.02.06
  • 심사 : 2020.03.19
  • 발행 : 2020.04.30

초록

이 논문은 대형버스의 화재에 관련된 고장사례를 고찰한 논문이다. 첫번째 사례는, 엔진룸 상단에 부착된 흡음재가 노후되어 떨어지면서 엔진쪽에 화재를 발생시킨 것으로 확인되었다. 두번째 사례는, 컴프레서의 부하로 인해 전기적인 단락에 의해 화재가 발생한 것으로 확인되었다. 세번째 사례는, 머플러 상단에 부착된 흡음재가 떨어져 배기매니폴드와 연결되어 있는 머플러 상단에서 점화되어 화재가 발생된 것으로 확인되었다. 네번째 사례는, 운전석 우측 크래쉬 보디부의 졍션 박스내에서 전기전인 쇼트가 발생하여 화재가 발생된 것으로 확인되었다. 따라서, 대형버스의 화재는 흡음재의 노후, 전기적인 단락에 의해 화재가 발생하였을 경우 피해가 크고 대단히 위험하므로 철저하게 관리하여 화재 발생이 없도록 하여야 한다.

This paper is a purpose to study the failure examples for a large bus vehicle fire. The first example, the researcher certified the fact that the absorbing material break away from the upper side of engine room because of weaken durability and the fire was produced in engine. The second example, it sought the fact that the fire breaks out by electric short because of over-load of compressor. The third example, it found the fact that the fire took place by heating of bellows upper part that was connected with muffler and exhaust manifold. The fourth example, it knew the fact that the fire occurred because of the electric short inside junction box of crash body part that was located to driver seat rightside. Therefore, the fire of a large bus occurring by decrepit of absorbing material and electric short have to thoroughgoingly manage the damage and dangerousness if it happens.

키워드

참고문헌

  1. Thomas M. De Santis, Charles T. Adams, Louis Molnar., et al, "Motor Vehicle Fire Investigation", SAE paper, 2008-01-0555
  2. Suzanne Smyth, Scott Dillon, "Common Cause of Bus Fires", SAE paper, 2012-01-0989
  3. Lee, I. K., Kook C. H., Suh M. W., et al., "Study for Fire Examples of LPG Leakage Including Fuel Hose, Injector and Pressure Regulator Connector in Vehicle", KIGAS, 17(3), 8-13, (2013)
  4. Lee, I. K., Kim, Y. G., et al.,"Study of Fire Examples Electrical Wire Short and Insulated Coating Melting by Heating Including Automotive Engine Room", KIGAS, 17(6), 15-19, (2013)
  5. Han, J. O., Ham, S. H., Lim, H. Y., and Lee, I. K., "A Study For Example of Fire Including with Combustible Substance and Electrical Overload in Automotive Inside Room", KIGAS, 18(3), 38-43, (2014)
  6. Lee, I. K., et al., "Fire Examples Study of Intake and and Exhaust System, Alternator Tunning and Inflow of Inflammables on Exhaust Part in a Car", KIGAS, 18(5), 47-51, (2014)
  7. Lee, I. K., Moon, H. H., et al., "Study for Examples of Fire Including Friction with Automotive Clutch, Manual Transmission and Tire System", KIGAS, 19(3), 49-53, (2015)
  8. https://ko.wikipedia.org/wiki/%EB%B2%84%EC%8A%A4
  9. Hyundai and Kia motors company, "General Technology of Commercial Vehicle", (2010)
  10. Hyundai Motor company, "Catalogue of Heavy Bus", (2016)