References
- Centers for diease control & prevention, (2015). Infection diseases surveillance yearbook.
- Ministry of health and welfare of Korea. (2015) Hospital which MERS patients were founded 2015.
- Melikov AK, Bolashikov Z, Georgiev E. Novel ventilation strategy for reducing the risk of airborne cross infection in hospital rooms. In: Proceedings of indoor air 2011 [Austin, USA].
- Hua Qian, Yuguo Li, Peter V. Nielsen, Xinhua Huang, Spatial distribution of infection risk of SARS transmission in a hospital ward, Building and Environment, Volume 44, Issue 8, August 2009, Pages 1651-1658 https://doi.org/10.1016/j.buildenv.2008.11.002
- G. Cao, H. Awbi, R. Yao, Y. Fan, K. Siren, R. Kosonen, J. Zhang, A review of the performance of different ventilation and airflow distribution systems in buildings, Build. Environ. 73 (2013) p.171-186. https://doi.org/10.1016/j.buildenv.2013.12.009
- S.L. Sinha, R.C. Arora, S. Roy, Numerical simulation of two dimensional room air flow with and without buoyancy, Energy Build., 32 (2000), pp. pp.121-129 https://doi.org/10.1016/S0378-7788(99)00047-X
- J.A. Khan, C.E. Feigley, E. Lee, M.R. Ahmed, S. Tamanna, Effects of inlet and exhaust locations and emitted gas density on indoor air contaminant concentrations, Build. Environ., 41 (7) (2006), pp. pp.851-863 https://doi.org/10.1016/j.buildenv.2005.04.002
- W. Wu, Z. Lin, An experimental study of the influence of a walking occupant on three air distribution methods, Build. Environ., 85 (2015), pp. 211-219 https://doi.org/10.1016/j.buildenv.2014.12.009
- C.Y. Shaw, J.S. Zhang, M.N. Said, F. Vaculik, R.J. Magee, Effect of air diffuser layout on the ventilation conditions of a workstation, Part 1: air distribution patterns, Part 2: air change efficiency and ventilation efficiency, ASHRAE Trans., 99 (2) (1993), pp. pp.125-143
- W.J. Fisk, D. Faulkner, D. Sullivan, F. Bauman, Air change effectiveness and pollutant removal efficiency during adverse mixing conditions, Indoor Air, 7 (1997), pp. 55-63 https://doi.org/10.1111/j.1600-0668.1997.t01-3-00007.x
- Hideyuki Amai, Atila Novoselac, Experimental study on air change effectiveness in mixing ventilation, Building and Environment, Volume 109, 15 November 2016, Pages 101-111 https://doi.org/10.1016/j.buildenv.2016.09.015
- Leung, M., Chan, A.H.S., Control and Management of Hospital Indoor Air Quality, Medical Science Monitor, 12(3), SR17-23
- ANSI/ASHRAE Standard 129e1997, Measuring Air-change Effectiveness, American Society of Heating, Refrigerating and AirConditioning Engineers, Inc., Atlanta, GA, 2002.
- A.N. WON, Hae-Eun SONG, Young-Kwon YANG, Jin-Chul PARK, Jung-Ha HWANG, Calculation of Appropriate Minimum Size of Isolation Rooms based on Questionnaire Survey of Experts and Analysis on Conditions of Isolation Room Use, Journal of Physics(scopus), 2017 (doi:10.1088/1742-6596/870/1/012025)
- Publication of the Ministry of Health and Welfare (on standard patient room size), 2016.
- Song, A.Won, S.Kim, C.Lee, J.Hwang, Analysis of indoor airflow in the respiratory disease ward department of a general hospital, Korean Institute of Architectural Sustainable Environment and Building System, Vol.12 No.1, 2018.02
- S. Liu, A. Novoselac, Air diffusion performance index (ADPI) of diffusers for heating mode, Build. Environ. 87 (2015) 215-223. https://doi.org/10.1016/j.buildenv.2015.01.021