Abstract
Excore Nuclear Flux Monitoring System in Nuclear Power Plant monitors continuous reactor power up to maximum 200%. The monitoring method, however, has to be different depending on the reactor power level. Because the logarithmic pulse signals must be counted and processed exactly due to large uncertainty if their levels are low, on the other hand, they must be processed through statistical methodolgies if theirs are high to get exact monitoring values, in point of thermal degradation view. Therefore, we developed thermal degradation input signal selection circuit to transfer low level reactor power monitoring circuit to high level reactor power circuit at rated value in this paper. We proved their validities through testing them using real data used in nuclear power plant and analyzed their results. And, These methods will be used to measure the neutron level of excore nuclear flux monitoring system in nuclear power plant.
원전에서 각종 전자카드는 시간에 경과함에 따라 열화가 되므로 이에 대한 대책이 필요하다. 이 열화 카드들 중에서 노외중성자감시시스템의 카드들은 방사선원의 레벨에서 발생되는 중성자속을 총 원자로출력의 200%까지 연속적으로 감시하게 되는데, 원자로출력이 낮을 때의 경우와 높을 때의 경우의 출력감시신호처리 방법이 달라야 한다. 원자로 출력이 낮을 때는 대수적으로 발생되는 펄스신호를 선형적으로 계수하여 신호처처리를 해야 되지만, 원자로 출력이 커지게 되면 통계이론에 의한 방법으로 처리해야 정확한 값을 얻을 수 있기 때문이다. 이때 전자카드가 열화되는 것이 문제가 된다. 따라서, 본 연구에서는 저출력일 때와 고출력일 때의 신호처리 방법을 달리하여 일정한 기준에 의한 원자로의 출력레벨에서 이를 저출력에서 고출력으로 전환하기 위한 열화 입력선택회로를 개발하였다. 개발된 선택회로의 신뢰성을 확인하기 위하여 원전에서 사용되는 실제의 데이터값을 적용하여 테스트하였으며, 그 결과를 분석하여 선택회로의 정당성을 입증하였다.