초록

The odor substances generated in a feed manufactory operating for the commercialization of animal-vegetable materials were analyzed and the odor reduction efficiency by a chemical scrubber was evaluated. The major causative substances in the feed manufactory comprised about 45.4% of ketone compounds and about 13.3% of aldehyde compounds. On the other hand, the removal efficiencies of diacetyl and acetoin as ketone compounds were 77.3% and 78.1%, respectively, by a chemical scrubber. Additionally, the removal efficiencies of acetaldehyde, butyraldehyde, valeraldehyde, 2-furancarboxaldehyde, and nonanal were 86.0%, 78.9%, 67.4%, 52.8%, and 71.9%, respectively. These rates were higher than the odor generation substance contribution rate as a result of treating the exhaust gas generated from the feed manufactory by the chemical scrubber using 5% of C3. It was also found that xylene, methylcyclopentane, benzene, ethylbenzene, 1,3,5-trimethylbenzene, and decane were almost not removed.

키워드

과제정보

연구 과제 주관 기관 : 인천대학교

참고문헌

  1. Ahn, H. Y., Kim, J. S., Song, J. H., 2016. Application of a wet-type non-thermal plasma for the removal of odorous compounds emitted from a vacuum evaporator in the treatment of acid metal-plating wastewater. Journal of Odor and Indoor Environment 15(1), 30-37. (in Korean with English abstract) https://doi.org/10.15250/joie.2016.15.1.30
  2. Cho, Y. J., Kim, Y. R., Choi, Y. J., 2015. Design status and improvement methods of packed bed scrubbers as an odor removal device in Siheung and Ansan smarthubs. Journal of Odor and Indoor Environment 14(4), 341-350. (in Korean with English abstract) https://doi.org/10.15250/joie.2015.14.4.341
  3. Choi, K. I., Lee, D. H., Choi, D. H., 2004. PCDDs/DFs at the inlets and outlets of wet scrubber in medium-sized waste incinerators. Journal of Korea Society of Waste Management 21(5), 447-455. (in Korean with English abstract)
  4. Jung. H. S., Won, Y. S., Sirega, D. M., Mission, S. K., Lim, J. H., 2017., Removal of hydrogen sulfide by using sodium carbonate impregnated activated carbon fiber. Clean Technology 23(1), 113-117. (in Korean with English abstract) https://doi.org/10.7464/ksct.2017.23.1.113
  5. Jung, S. C., Lee, S. H., 2012. Practical usage of lowtemperature metal catalyst for the destruction of volatile organic compounds (VOCs). Korean Society of Environmental Engineers 34(6), 397-405. (in Korean with English abstract) https://doi.org/10.4491/KSEE.2012.34.6.397
  6. Kim, D. J., Seo, S. G., Kim, S. C., 2005. Removal of odorcontaining sulfur compound, methyl mercaptan using modified activated carbon with various acidic chemicals. Journal of Korean Society for Atmospheric Environment 21(2), 155-160. (in Korean with English abstract)
  7. Ko, B. C., Park, Y. H., Kim, D. I., Lee, M. G., Kam, S. K., 2013. Odor removal characteristics of biofilters in domestic sewage treatment facilities analyzing composite odor and odor quotient. Journal of the Environmental Sciences 22(1), 109-117. (in Korean with English abstract) https://doi.org/10.5322/JES.2013.22.1.109
  8. Kwon, S. W., Hong, J. K., 2013. An experimental study on the deodorization performance of exhaust filter unit in a laboratory animal breeding facility. Korean Journal of Air-Conditioning and Refrigeration Engineering 25(4), 194-200. (in Korean with English abstract) https://doi.org/10.6110/KJACR.2013.25.4.194
  9. Lee, S. C., Kim, D. J., 2012. Odorous gas removal in biofilter with powdered activated carbon and zeolite coated polyurethane foam. Clean Technology 18(2), 209-215. (in Korean with English abstract) https://doi.org/10.7464/ksct.2012.18.2.209
  10. Lim, K. H., 2018. Treatment of malodorous waste air by a biofilter process equipped with a humidifier composed of fluidized aerobic and anoxic reactor. Korean Chemical Engineering Research 56(1), 85-95. (in Korean with English abstract) https://doi.org/10.9713/kcer.2018.56.1.85
  11. Lim, S. I., Kim, N. J., Kim, S. M., Lee, S. H., Kim, S. U., Chang, W. S., Park, D. W., Kimmarry, L. H., Kim, J. H., 2009. Development of VOCs treatment technology using high efficiency hybrid system with multi-scrone. Korean Society of Environmental Engineers 31(7), 491-498. (in Korean with English abstract)
  12. Park, J. O., Cho, G. J., Kwak, J., 2009. Study on characteristics of odors released from animal feed factory. The Annual Report of Busan Metropolitan City Institute of Health and Environment 19(1), 199-206. (in Korean with English abstract)
  13. Park, Y. G., Kim, J. I., 2011. Efficiency characteristics by mixed absorbents for the removal of odor compounds in the wet scrubber. Applied Chemistry for Engineering 22(1), 48-55. (in Korean with English abstract)
  14. Shin, J. Y., Seo, S. C., Kim, D. K., 2016. An up-flow botanical bioreactor for odor removal. Journal of Odor and Indoor Environment 15(4), 345-351. (in Korean with English abstract) https://doi.org/10.15250/joie.2016.15.4.345
  15. Song, J. H., 2007. Biofilter technology for odor control. Korean Society of Odor Research and Engineering 6(4), 246-253. (in Korean with English abstract)
  16. Yu, M. S., Yang, S. B., Kim, Y, M., Jin, H. S., 2015. Evaluation of removal efficiency of single odor component using ion cluster. in proceedings of the Korean Environmental Sciences Society Conference 24, The Korean Environmental Sciences Society, Suanbo, 117.

피인용 문헌

  1. A study on the efficiency of pollution control using the scrubber with a spiral filter and a cyclone system for decreasing particulate matter and odor inducing compounds vol.18, pp.2, 2019, https://doi.org/10.15250/joie.2019.18.2.112
  2. On the method of odor management with the civil complaint patterns for the improvement of urban environment vol.19, pp.2, 2018, https://doi.org/10.15250/joie.2020.19.2.120