Experiment for Duct Development to Cool Components in Vehicle Engine Room

차량 엔진룸내 부품 냉각용 덕트 개발을 위한 실험

  • Lee, Suk Young (Department of Mechanical Engineering, Inha Technical College)
  • 이석영 (인하공업전문대학 기계과)
  • Received : 2018.11.06
  • Accepted : 2018.12.05
  • Published : 2018.12.31

Abstract

In order to improve the durability of components in the vehicle engine room, an experiment to improve the air cooling effect of components by installing a cooling duct using intake air aiming at four components, such as generator, battery, ECU and power steel oil, Respectively, experimental results show that the overall component temperature has been reduced, and the reduced temperature difference is in the order of generator, ECU, power steel oil and battery. In order to improve the temperature difference due to these components, it is necessary to optimize the design through the flow analysis in the duct in the future.

자동차 엔진룸내 부품의 내구성 향상을 위하여 냉각 가능성을 판단하고자 발전기, 배터리, ECU 및 파워스틸 오일 등 4가지 부품을 목표로 흡입공기를 사용한 냉각용 덕트를 설치하여 부품에 대한 공랭효과를 향상시키기 위한 실험을 수행하였다. 실험 결과, 전반적으로 부품 온도가 저감되었으며 감소된 온도 차이는 발전기, ECU, 파워스틸 오일 및 배터리 순으로 크게 나타났다. 이러한 부품에 따른 온도 차이를 개선하기 위해서는 차후에 덕트 내부에 대한 유동해석을 통한 최적화 설계가 필요하다고 판단된다.

Keywords

OGJGBN_2018_v27n4_98_f0001.png 이미지

Fig. 1 Experimental apparatus

OGJGBN_2018_v27n4_98_f0002.png 이미지

Fig. 2. Components for cooling in engine room

OGJGBN_2018_v27n4_98_f0003.png 이미지

Fig. 3. Duct for cooling the components in engine room

OGJGBN_2018_v27n4_98_f0004.png 이미지

Fig. 4. Air supply device and chassis dynamo system

OGJGBN_2018_v27n4_98_f0005.png 이미지

Fig. 5. Temperature sensor for measuring temperature of components

OGJGBN_2018_v27n4_98_f0006.png 이미지

Fig. 6. Experiment through driving using chassis dynamo system

OGJGBN_2018_v27n4_98_f0007.png 이미지

Fig. 7. Component temperature measured by no cooling experiment

OGJGBN_2018_v27n4_98_f0008.png 이미지

Fig. 8. Component temperature measured by cooling experiment

OGJGBN_2018_v27n4_98_f0009.png 이미지

Fig. 9. Reduced component temperature measured by experiment

Table 1. Specifications of cooling duct

OGJGBN_2018_v27n4_98_t0001.png 이미지

Table 2. Engine specifications

OGJGBN_2018_v27n4_98_t0002.png 이미지

Table 3. Component temperature measured by experiment

OGJGBN_2018_v27n4_98_t0003.png 이미지

Table 4. Reduced component temperature measured by experiment

OGJGBN_2018_v27n4_98_t0004.png 이미지

References

  1. Song, B. K., Oh, S. M., Kang, J. J. and Kim, S. J., 2012, An experimental study on the temperature of electronic components in OBC based on the cooling water and the ambient temperature, Transactions of KSAE, Vol. 11, pp. 2493-2497
  2. Oh, K. T., Kim, J. H., Lee, S. W., Kim, Y. S., Ha, J. W. and Kang, W. K., 2007, Automobile underhood thermal and flow simulation using CFD, Journal of Computational Fluids Engineering, Vol 12, pp. 22-27
  3. Lee, Y. L., 2008, A study of the improvement of thermal performance of a junction box of a passenger car", Transactions of KSAE, Vol. 16, No. 2, pp.136-142
  4. Lee, T. E., Suh, J. S., Jeong, S. H. and Park, Y. S., 2009, A study on thermal and fluid characteristics inside engine room of auxiliary power unit for tracked vehicle, Journal of the Korean Society for Precision Engineering, Vol. 26, No. 12, pp. 85-93
  5. Katoh, N., 1991, Numerical simulation on the three dimensional flow and heat transfer in the engine compartment," SAE 910306, USA.
  6. Lyu, M. S., Lee, E. J. and Ku, Y. G., 1996, The numerical study of the effect of car front opening area on the mean flow in engine room, Transactions of KSAE, Vol. 4, No. 2, pp. 158-165